-
The High Voltage Splitter board for the JUNO SPMT system
Authors:
Pablo Walker,
Juan Pedro Ochoa-Ricoux,
Angel Abusleme,
Agustin Campeny,
Mathieu Bongrand,
Clément Bordereau,
José Busto,
Anatael Cabrera,
Stéphane Callier,
Steven Calvez,
Cédric Cerna,
Thomas Chabot,
Po-An Chen,
Guoming Chen,
Ziliang Chu,
Gérard Claverie,
Christophe De La Taille,
Charles-Edouard Demonchy,
Selma Conforti Di Lorenzo,
Frédéric Druillole,
Lei Fan,
Amélie Fournier,
Yang Han,
Miao He,
Patrick Hellmuth
, et al. (52 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control.
△ Less
Submitted 8 May, 2025;
originally announced May 2025.
-
The Stochastic Light Confinement of LiquidO
Authors:
LiquidO Collaboration,
J. Apilluelo,
L. Asquith,
E. F. Bannister,
N. P. Barradas,
J. L. Beney,
M. Berberan e Santos,
X. de la Bernardie,
T. J. C. Bezerra,
M. Bongrand,
C. Bourgeois,
D. Breton,
C. Buck,
J. Busto,
K. Burns,
A. Cabrera,
A. Cadiou,
E. Calvo,
E. Chauveau,
B. J. Cattermole,
M. Chen,
P. Chimenti,
D. F. Cowen,
S. Dusini,
A. Earle
, et al. (72 additional authors not shown)
Abstract:
Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. Liquid…
▽ More
Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. LiquidO is a new technique pioneering the use of opaque media to stochastically confine light around each energy deposition while collecting it with an array of fibres that thread the medium. This approach preserves topological event information otherwise lost in the conventional approach, enabling real-time imaging down to the MeV scale. Our article demonstrates LiquidO's imaging principle with a ten-litre prototype, revealing successful light confinement of 90% of the detected light within a 5 cm radius sphere, using a custom opaque scintillator with a scattering length on the order of a few millimetres. These high-resolution imaging capabilities unlock opportunities in fundamental physics research and applications beyond. The absolute amount of light detected is also studied, including possible data-driven extrapolations to LiquidO-based detectors beyond prototyping limitations. Additionally, LiquidO's timing capabilities are explored through its ability to distinguish Cherenkov light from a slow scintillator.
△ Less
Submitted 12 March, 2025; v1 submitted 4 March, 2025;
originally announced March 2025.
-
Simulation of the Background from $^{13}$C$(α, n)^{16}$O Reaction in the JUNO Scintillator
Authors:
JUNO Collaboration,
Thomas Adam,
Kai Adamowicz,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Fengpeng An,
Costas Andreopoulos,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Beretta,
Antonio Bergnoli,
Nikita Bessonov,
Daniel Bick,
Lukas Bieger,
Svetlana Biktemerova
, et al. (608 additional authors not shown)
Abstract:
Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($α, n$)…
▽ More
Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($α, n$) reactions. In organic liquid scintillator detectors, $α$ particles emitted from intrinsic contaminants such as $^{238}$U, $^{232}$Th, and $^{210}$Pb/$^{210}$Po, can be captured on $^{13}$C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ($α, n$) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $^{13}$C$(α, n)^{16}$O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.
△ Less
Submitted 2 May, 2025; v1 submitted 2 March, 2025;
originally announced March 2025.
-
COCOA: a compact Compton camera for astrophysical observation of MeV-scale gamma rays
Authors:
LiquidO Collaboration,
S. R. Soleti,
J. J. Gómez-Cadenas,
J. Apilluelo,
L. Asquith,
E. F. Bannister,
N. P. Barradas,
C. L. Baylis,
J. L. Beney,
M. Berberan e Santos,
X. de la Bernardie,
T. J. C. Bezerra,
M. Bongrand,
C. Bourgeois,
D. Breton,
J. Busto,
K. Burns,
A. Cabrera,
A. Cadiou,
E. Calvo,
M. de Carlos Generowicz,
E. Chauveau,
B. J. Cattermole,
M. Chen,
P. Chimenti
, et al. (67 additional authors not shown)
Abstract:
COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable…
▽ More
COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.
△ Less
Submitted 12 May, 2025; v1 submitted 28 February, 2025;
originally announced February 2025.
-
Prediction of Energy Resolution in the JUNO Experiment
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Kai Adamowicz,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta,
Antonio Bergnoli,
Daniel Bick
, et al. (629 additional authors not shown)
Abstract:
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components o…
▽ More
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of study reveal an energy resolution of 2.95\% at 1~MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors.
△ Less
Submitted 9 January, 2025; v1 submitted 28 May, 2024;
originally announced May 2024.
-
Multi-Calorimetry in Light-based Neutrino Detectors
Authors:
Anatael Cabrera,
Yang Han,
Steven Calvez,
Emmanuel Chauveau,
Hanyi Chen,
Hervé de Kerret,
Stefano Dusini,
Marco Grassi,
Leonard Imbert,
Jiajun Li,
Roberto Carlos Mandujano,
Diana Navas-Nicolás,
Hiroshi Nunokawa,
Michel Obolensky,
Juan Pedro Ochoa-Ricoux,
Guillaume Pronost,
Benoit Viaud,
Frédéric Yermia
Abstract:
Neutrino detectors are among the largest photon detection instruments, built to capture scarce photons upon energy deposition. Many discoveries in neutrino physics, including the neutrino itself, are inseparable from the advances in photon detection technology, particularly in photo-sensors and readout electronics, to yield ever higher precision and richer detection information. The measurement of…
▽ More
Neutrino detectors are among the largest photon detection instruments, built to capture scarce photons upon energy deposition. Many discoveries in neutrino physics, including the neutrino itself, are inseparable from the advances in photon detection technology, particularly in photo-sensors and readout electronics, to yield ever higher precision and richer detection information. The measurement of the energy of neutrinos, referred to as calorimetry, can be achieved in two distinct approaches: photon-counting, where single-photon can be counted digitally, and photon-integration, where multi-photons are aggregated and estimated via analogue signals. The energy is pursued today to reach permille level systematics control precision in ever-vast volumes, exemplified by experiments like JUNO. The unprecedented precision brings to the foreground the systematics due to calorimetric response entanglements in energy, position and time that were negligible in the past, thus driving further innovation in calorimetry. This publication describes a novel articulation that detectors can be endowed with multiple photon detection systems. This multi-calorimetry approach opens the notion of dual-calorimetry detector, consisting of both photon-counting and photon-integration systems, as a cost-effective evolution from the single calorimetry setups used over several decades for most experiments so far. The dual-calorimetry design exploits unique response synergies between photon-counting and photon-integration systems, including correlations and cancellations in calorimetric responses, to maximise the mitigation of response entanglements, thereby yielding permille-level high-precision calorimetry.
△ Less
Submitted 6 December, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos
Authors:
LiquidO Consortium,
:,
A. Cabrera,
M. Chen,
F. Mantovani,
A. Serafini,
V. Strati,
J. Apilluelo,
L. Asquith,
J. L. Beney,
T. J. C. Bezerra,
M. Bongrand,
C. Bourgeois,
D. Breton,
M. Briere,
J. Busto,
A. Cadiou,
E. Calvo,
V. Chaumat,
E. Chauveau,
B. J. Cattermole,
P. Chimenti,
C. Delafosse,
H. de Kerret,
S. Dusini
, et al. (55 additional authors not shown)
Abstract:
The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity…
▽ More
The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity dominated by potassium (40K) and the decay chains of uranium (238U) and thorium (232Th). This radiogenic energy output is critical to planetary dynamics and must be accurately measured for a complete understanding of the overall heat budget and thermal history of the Earth. Detecting geoneutrinos remains the only direct probe to do so and constitutes a challenging objective in modern neutrino physics. In particular, the intriguing potassium geoneutrinos have never been observed and thus far have been considered impractical to measure. We propose here a novel approach for potassium geoneutrino detection using the unique antimatter signature of antineutrinos to reduce the otherwise overwhelming backgrounds to observing this rarest signal. The proposed detection framework relies on the innovative LiquidO detection technique to enable positron (e+) identification and antineutrino interactions with ideal isotope targets identified here for the first time. We also provide the complete experimental methodology to yield the first potassium geoneutrino discovery.
△ Less
Submitted 23 August, 2023; v1 submitted 8 August, 2023;
originally announced August 2023.
-
The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Mass production and characterization of 3-inch PMTs for the JUNO experiment
Authors:
Chuanya Cao,
Jilei Xu,
Miao He,
Angel Abusleme,
Mathieu Bongrand,
Clément Bordereau,
Dominique Breton,
Anatael Cabrera,
Agustin Campeny,
Cédric Cerna,
Haoqiang Chen,
Po-An Chen,
Gérard Claverie,
Selma Conforti Di Lorenzo,
Christophe De La Taille,
Frédéric Druillole,
Amélie Fournier,
Marco Grassi,
Xiaofei Gu,
Michael Haacke,
Yang Han,
Patrick Hellmuth,
Yuekun Heng,
Rafael Herrera,
Yee Hsiung
, et al. (42 additional authors not shown)
Abstract:
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was perf…
▽ More
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.
△ Less
Submitted 26 February, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Search for Signatures of Sterile Neutrinos with Double Chooz
Authors:
The Double Chooz Collaboration,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
J. C. Barriere,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
H. Furuta,
I. Gil-Botella,
A. Givaudan,
H. Gomez
, et al. (70 additional authors not shown)
Abstract:
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappe…
▽ More
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range $5 \cdot 10^{-3} $ eV$^2 \lesssim Δm^2_{41} \lesssim 3\cdot 10^{-1} $ eV$^2$ for mixing angles down to $\sin^2 2θ_{14} \gtrsim 0.02$. No significant disappearance additionally to the conventional disappearance related to $θ_{13} $ is observed and correspondingly exclusion bounds on the sterile mixing parameter $θ_{14} $ as function of $ Δm^2_{41} $ are obtained.
△ Less
Submitted 19 July, 2021; v1 submitted 11 September, 2020;
originally announced September 2020.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Reactor Rate Modulation oscillation analysis with two detectors in Double Chooz
Authors:
Double Chooz Collaboration,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
H. Furuta,
I. Gil-Botella,
L. F. G. Gonzalez,
M. C. Goodman,
T. Hara,
D. Hellwig
, et al. (62 additional authors not shown)
Abstract:
A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data colle…
▽ More
A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the \nue interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and $^{9}$Li decays. The background-model-independent determination of the mixing angle yields sin$^2(2θ_{13})=0.094\pm0.017$, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on $θ_{13}$ to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86\%, reducing the 1.43\% uncertainty associated to the expectation.
△ Less
Submitted 3 December, 2020; v1 submitted 27 July, 2020;
originally announced July 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
SoLid: A short baseline reactor neutrino experiment
Authors:
SoLid Collaboration,
Y. Abreu,
Y. Amhis,
L. Arnold,
G. Barber,
W. Beaumont,
S. Binet,
I. Bolognino,
M. Bongrand,
J. Borg,
D. Boursette,
V. Buridon,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupe,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
T. Durkin,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves
, et al. (37 additional authors not shown)
Abstract:
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino en…
▽ More
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration.
△ Less
Submitted 15 December, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
Combined sensitivity to the neutrino mass ordering with JUNO, the IceCube Upgrade, and PINGU
Authors:
IceCube-Gen2 Collaboration,
:,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
T. C. Arlen,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
I. Bartos,
S. W. Barwick,
B. Bastian
, et al. (421 additional authors not shown)
Abstract:
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscill…
▽ More
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscillation experiments JUNO and the IceCube Upgrade, which employ two very distinct and complementary routes towards the neutrino mass ordering. The approach pursued by the $20\,\mathrm{kt}$ medium-baseline reactor neutrino experiment JUNO consists of a careful investigation of the energy spectrum of oscillated $\barν_e$ produced by ten nuclear reactor cores. The IceCube Upgrade, on the other hand, which consists of seven additional densely instrumented strings deployed in the center of IceCube DeepCore, will observe large numbers of atmospheric neutrinos that have undergone oscillations affected by Earth matter. In a joint fit with both approaches, tension occurs between their preferred mass-squared differences $ Δm_{31}^{2}=m_{3}^{2}-m_{1}^{2} $ within the wrong mass ordering. In the case of JUNO and the IceCube Upgrade, this allows to exclude the wrong ordering at $>5σ$ on a timescale of 3--7 years --- even under circumstances that are unfavorable to the experiments' individual sensitivities. For PINGU, a 26-string detector array designed as a potential low-energy extension to IceCube, the inverted ordering could be excluded within 1.5 years (3 years for the normal ordering) in a joint analysis.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Neutrino Physics with an Opaque Detector
Authors:
A. Cabrera,
A. Abusleme,
J. dos Anjos,
T. J. C. Bezerra,
M. Bongrand,
C. Bourgeois,
D. Breton,
C. Buck,
J. Busto,
E. Calvo,
E. Chauveau,
M. Chen,
P. Chimenti,
F. Dal Corso,
G. De Conto,
S. Dusini,
G. Fiorentini,
C. Frigerio Martins,
A. Givaudan,
P. Govoni,
B. Gramlich,
M. Grassi,
Y. Han,
J. Hartnell,
C. Hugon
, et al. (37 additional authors not shown)
Abstract:
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the convention…
▽ More
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.
△ Less
Submitted 6 January, 2022; v1 submitted 7 August, 2019;
originally announced August 2019.
-
Commissioning and Operation of the Readout System for the SoLid Neutrino Detector
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order…
▽ More
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.
△ Less
Submitted 31 August, 2019; v1 submitted 13 December, 2018;
originally announced December 2018.
-
Development of a Quality Assurance Process for the SoLid Experiment
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sh…
▽ More
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overlineν_e$ target for the inverse beta decay of ($\overlineν_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overlineν_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.
△ Less
Submitted 20 December, 2018; v1 submitted 13 November, 2018;
originally announced November 2018.
-
Optimisation of the scintillation light collection and uniformity for the SoLid experiment
Authors:
Y. Abreu,
Y. Amhis,
W. Beaumont,
M. Bongrand,
D. Boursette,
B. C. Castle,
K. Clark,
B. Coupé,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva,
L. N. Kalousis,
M. Labare,
G. Lehaut,
S. Manley
, et al. (26 additional authors not shown)
Abstract:
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires hi…
▽ More
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and $^6$LiF:ZnS(Ag) screens. A precision test bench based on a $^{207}$Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1~MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the $^6$LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52$\pm$2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.
△ Less
Submitted 7 September, 2018; v1 submitted 6 June, 2018;
originally announced June 2018.
-
Yields and production rates of cosmogenic $^9$Li and $^8$He measured with the Double Chooz near and far detectors
Authors:
H. de Kerret,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
J. C. Barriere,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
D. Franco,
H. Furuta,
I. Gil-Botella,
A. Givaudan
, et al. (73 additional authors not shown)
Abstract:
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresp…
▽ More
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresponding to a mean muon energy of $32.1\pm2.0\,\mathrm{GeV}$ ($63.7\pm5.5\,\mathrm{GeV}$). Comparing the data to a detailed simulation of the $^9$Li and $^8$He decays, the contribution of the $^8$He radioisotope at both detectors is found to be compatible with zero. The observed $^9$Li yields in the near and far detectors are $5.51\pm0.51$ and $7.90\pm0.51$, respectively, in units of $10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2} }$. The shallow overburdens of the near and far detectors give a unique insight when combined with measurements by KamLAND and Borexino to give the first multi--experiment, data driven relationship between the $^9$Li yield and the mean muon energy according to the power law $Y = Y_0( <E_μ >/ 1\,\mathrm{GeV})^{\overlineα}$, giving $\overlineα=0.72\pm0.06$ and $Y_0=(0.43\pm0.11)\times 10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2}}$. This relationship gives future liquid scintillator based experiments the ability to predict their cosmogenic $^9$Li background rates.
△ Less
Submitted 10 October, 2018; v1 submitted 22 February, 2018;
originally announced February 2018.
-
Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz
Authors:
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. I. Crespo-Anadón,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
M. Fallot,
D. Franco,
H. Furuta,
I. Gil-Botella
, et al. (72 additional authors not shown)
Abstract:
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implemen…
▽ More
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implementations, this method uses the Fourier power spectra of the scintillation pulse shapes to obtain event-wise information. A classification variable built from spectral information was able to achieve an unprecedented performance, despite the lack of optimization at the detector design level. Several examples of event classification are provided, ranging from differentiation between the detector volumes and an efficient rejection of instrumental light noise, to some sensitivity to the particle type, such as stopping muons, ortho-positronium formation, alpha particles as well as electrons and positrons. In combination with other techniques the method is expected to allow for a versatile and more efficient background rejection in the future, especially if detector optimization is taken into account at the design level.
△ Less
Submitted 18 January, 2018; v1 submitted 11 October, 2017;
originally announced October 2017.
-
On the potential of multivariate techniques for the determination of multidimensional efficiencies
Authors:
Benoit Viaud
Abstract:
Differential measurements of particle collisions or decays can provide stringent constraints on physics beyond the Standard Model of particle physics. In particular, the distributions of the kinematical and angular variables that characterise heavy me- son multibody decays are non trivial and can sign the underlying interaction physics. In the era of high luminosity opened by the advent of the Lar…
▽ More
Differential measurements of particle collisions or decays can provide stringent constraints on physics beyond the Standard Model of particle physics. In particular, the distributions of the kinematical and angular variables that characterise heavy me- son multibody decays are non trivial and can sign the underlying interaction physics. In the era of high luminosity opened by the advent of the Large Hadron Collider and of Flavor Factories, differential measurements are less and less dominated by statistical precision and require a precise determination of efficiencies that depend simultaneously on several variables and do not factorise in these variables. This docu- ment is a reflection on the potential of multivariate techniques for the determination of such multidimensional efficiencies. We carried out two case studies that show that multilayer perceptron neural networks can determine and correct for the distortions introduced by reconstruction and selection criteria in the multidimensional phase space of the decays $B^{0}\rightarrow K^{*0}(\rightarrow K^{+}π^{-}) μ^{+}μ^{-}$ and $D^{0}\rightarrow K^{-}π^{+}π^{+}π^{-}$, at the price of a minimal analysis effort. We conclude that this method can already be used for measurements which statistical precision does not yet reach the percent level and that with more sophisticated machine learning methods, the aforementioned potential is very promising.
△ Less
Submitted 11 February, 2016;
originally announced February 2016.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
Combined phase space characterization at the PEP-II IP using single-beam and luminous-region measurements
Authors:
A. Bevan,
W. Kozanecki,
B. Viaud,
Y. Cai,
A. Fisher,
C. O'Grady,
J. Thompson,
M. Weaver
Abstract:
We present a novel method to characterize the e+/- phase space at the IP of the SLAC B-factory, that combines single-beam measurements with a detailed mapping of luminous-region observables. Transverse spot sizes are determined in the two rings with synchrotron-light monitors and extrapolated to the IP using measured lattice functions. The specific luminosity, which is proportional to the invers…
▽ More
We present a novel method to characterize the e+/- phase space at the IP of the SLAC B-factory, that combines single-beam measurements with a detailed mapping of luminous-region observables. Transverse spot sizes are determined in the two rings with synchrotron-light monitors and extrapolated to the IP using measured lattice functions. The specific luminosity, which is proportional to the inverse product of the overlap IP beam sizes, is continuously monitored using radiative-Bhabha events. The spatial variation of the luminosity and of the transverse-boost distribution of the colliding e+/-, are measured using e+ e- --> mu+ mu- events reconstructed in the BaBar detector. The combination of these measurements provide constraints on the emittances, horizontal and vertical spot sizes, angular divergences and beta functions of both beams at the IP during physics data-taking. Preliminary results of this combined spot-size analysis are confronted with independent measurements of IP beta-functions and overlap IP beam sizes at low beam current.
△ Less
Submitted 10 July, 2006;
originally announced July 2006.