-
VORTEX: Physics-Driven Data Augmentations Using Consistency Training for Robust Accelerated MRI Reconstruction
Authors:
Arjun D Desai,
Beliz Gunel,
Batu M Ozturkler,
Harris Beg,
Shreyas Vasanawala,
Brian A Hargreaves,
Christopher RĂ©,
John M Pauly,
Akshay S Chaudhari
Abstract:
Deep neural networks have enabled improved image quality and fast inference times for various inverse problems, including accelerated magnetic resonance imaging (MRI) reconstruction. However, such models require a large number of fully-sampled ground truth datasets, which are difficult to curate, and are sensitive to distribution drifts. In this work, we propose applying physics-driven data augmen…
▽ More
Deep neural networks have enabled improved image quality and fast inference times for various inverse problems, including accelerated magnetic resonance imaging (MRI) reconstruction. However, such models require a large number of fully-sampled ground truth datasets, which are difficult to curate, and are sensitive to distribution drifts. In this work, we propose applying physics-driven data augmentations for consistency training that leverage our domain knowledge of the forward MRI data acquisition process and MRI physics to achieve improved label efficiency and robustness to clinically-relevant distribution drifts. Our approach, termed VORTEX, (1) demonstrates strong improvements over supervised baselines with and without data augmentation in robustness to signal-to-noise ratio change and motion corruption in data-limited regimes; (2) considerably outperforms state-of-the-art purely image-based data augmentation techniques and self-supervised reconstruction methods on both in-distribution and out-of-distribution data; and (3) enables composing heterogeneous image-based and physics-driven data augmentations. Our code is available at https://github.com/ad12/meddlr.
△ Less
Submitted 17 June, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Quantitative Parametric Mapping of Tissues Properties from Standard Magnetic Resonance Imaging Enabled by Deep Learning
Authors:
Yan Wu,
Yajun Ma,
Youngwook Kee,
Nataliya Kovalchuk,
Dante Capaldi,
Hongyi Ren,
Steven Hancock,
Eric Chang,
Marcus Alley,
John Pauly,
Jiang Du,
Shreyas Vasanawala,
Lei Xing
Abstract:
Magnetic resonance imaging (MRI) offers superior soft tissue contrast and is widely used in biomedicine. However, conventional MRI is not quantitative, which presents a bottleneck in image analysis and digital healthcare. Typically, additional scans are required to disentangle the effect of multiple parameters of MR and extract quantitative tissue properties. Here we investigate a data-driven stra…
▽ More
Magnetic resonance imaging (MRI) offers superior soft tissue contrast and is widely used in biomedicine. However, conventional MRI is not quantitative, which presents a bottleneck in image analysis and digital healthcare. Typically, additional scans are required to disentangle the effect of multiple parameters of MR and extract quantitative tissue properties. Here we investigate a data-driven strategy Q^2 MRI (Qualitative and Quantitative MRI) to derive quantitative parametric maps from standard MR images without additional data acquisition. By taking advantage of the interdependency between various MRI parametric maps buried in training data, the proposed deep learning strategy enables accurate prediction of tissue relaxation properties as well as other biophysical and biochemical characteristics from a single or a few images with conventional T_1/T_2 weighting. Superior performance has been achieved in quantitative MR imaging of the knee and liver. Q^2 MRI promises to provide a powerful tool for a variety of biomedical applications and facilitate the next generation of digital medicine.
△ Less
Submitted 10 August, 2021;
originally announced August 2021.
-
SLfRank: Shinnar-Le-Roux Pulse Design with Reduced Energy and Accurate Phase Profiles using Rank Factorization
Authors:
Frank Ong,
Zheng Zhong,
Congyu Liao,
Michael Lustig,
Shreyas Vasanawala,
John Pauly
Abstract:
The Shinnar-Le-Roux (SLR) algorithm is widely used to design frequency selective pulses with large flip angles. We improve its design process to generate pulses with lower energy (by as much as 26%) and more accurate phase profiles.
Concretely, the SLR algorithm consists of two steps: (1) an invertible transform between frequency selective pulses and polynomial pairs that represent Cayley-Klein…
▽ More
The Shinnar-Le-Roux (SLR) algorithm is widely used to design frequency selective pulses with large flip angles. We improve its design process to generate pulses with lower energy (by as much as 26%) and more accurate phase profiles.
Concretely, the SLR algorithm consists of two steps: (1) an invertible transform between frequency selective pulses and polynomial pairs that represent Cayley-Klein (CK) parameters and (2) the design of the CK polynomial pair to match the desired magnetization profiles. Because the CK polynomial pair is bi-linearly coupled, the original algorithm sequentially solves for each polynomial instead of jointly. This results in sub-optimal pulses.
Instead, we leverage a convex relaxation technique, commonly used for low rank matrix recovery, to address the bi-linearity. Our numerical experiments show that the resulting pulses are almost always globally optimal in practice. For slice excitation, the proposed algorithm results in more accurate linear phase profiles. And in general the improved pulses have lower energy than the original SLR pulses.
△ Less
Submitted 19 October, 2022; v1 submitted 13 March, 2021;
originally announced March 2021.
-
Spectral Decomposition in Deep Networks for Segmentation of Dynamic Medical Images
Authors:
Edgar A. Rios Piedra,
Morteza Mardani,
Frank Ong,
Ukash Nakarmi,
Joseph Y. Cheng,
Shreyas Vasanawala
Abstract:
Dynamic contrast-enhanced magnetic resonance imaging (DCE- MRI) is a widely used multi-phase technique routinely used in clinical practice. DCE and similar datasets of dynamic medical data tend to contain redundant information on the spatial and temporal components that may not be relevant for detection of the object of interest and result in unnecessarily complex computer models with long trainin…
▽ More
Dynamic contrast-enhanced magnetic resonance imaging (DCE- MRI) is a widely used multi-phase technique routinely used in clinical practice. DCE and similar datasets of dynamic medical data tend to contain redundant information on the spatial and temporal components that may not be relevant for detection of the object of interest and result in unnecessarily complex computer models with long training times that may also under-perform at test time due to the abundance of noisy heterogeneous data. This work attempts to increase the training efficacy and performance of deep networks by determining redundant information in the spatial and spectral components and show that the performance of segmentation accuracy can be maintained and potentially improved. Reported experiments include the evaluation of training/testing efficacy on a heterogeneous dataset composed of abdominal images of pediatric DCE patients, showing that drastic data reduction (higher than 80%) can preserve the dynamic information and performance of the segmentation model, while effectively suppressing noise and unwanted portion of the images.
△ Less
Submitted 29 September, 2020;
originally announced October 2020.
-
Analysis of Deep Complex-Valued Convolutional Neural Networks for MRI Reconstruction
Authors:
Elizabeth K. Cole,
Joseph Y. Cheng,
John M. Pauly,
Shreyas S. Vasanawala
Abstract:
Many real-world signal sources are complex-valued, having real and imaginary components. However, the vast majority of existing deep learning platforms and network architectures do not support the use of complex-valued data. MRI data is inherently complex-valued, so existing approaches discard the richer algebraic structure of the complex data. In this work, we investigate end-to-end complex-value…
▽ More
Many real-world signal sources are complex-valued, having real and imaginary components. However, the vast majority of existing deep learning platforms and network architectures do not support the use of complex-valued data. MRI data is inherently complex-valued, so existing approaches discard the richer algebraic structure of the complex data. In this work, we investigate end-to-end complex-valued convolutional neural networks - specifically, for image reconstruction in lieu of two-channel real-valued networks. We apply this to magnetic resonance imaging reconstruction for the purpose of accelerating scan times and determine the performance of various promising complex-valued activation functions. We find that complex-valued CNNs with complex-valued convolutions provide superior reconstructions compared to real-valued convolutions with the same number of trainable parameters, over a variety of network architectures and datasets.
△ Less
Submitted 11 May, 2020; v1 submitted 3 April, 2020;
originally announced April 2020.
-
Extreme MRI: Large-Scale Volumetric Dynamic Imaging from Continuous Non-Gated Acquisitions
Authors:
Frank Ong,
Xucheng Zhu,
Joseph Y. Cheng,
Kevin M. Johnson,
Peder E. Z. Larson,
Shreyas S. Vasanawala,
Michael Lustig
Abstract:
Purpose: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast enhanced (DCE) imaging.
Theory and Methods: The problem considered here requires recovering hundred-gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over severa…
▽ More
Purpose: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast enhanced (DCE) imaging.
Theory and Methods: The problem considered here requires recovering hundred-gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (1) A compressed representation using multi-scale low rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (2) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory resolved reconstruction for pulmonary imaging.
Results: The proposed technique shows transient dynamics that are not seen in gating based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features.
Conclusion: We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.
△ Less
Submitted 5 February, 2020; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Compressed Sensing: From Research to Clinical Practice with Data-Driven Learning
Authors:
Joseph Y. Cheng,
Feiyu Chen,
Christopher Sandino,
Morteza Mardani,
John M. Pauly,
Shreyas S. Vasanawala
Abstract:
Compressed sensing in MRI enables high subsampling factors while maintaining diagnostic image quality. This technique enables shortened scan durations and/or improved image resolution. Further, compressed sensing can increase the diagnostic information and value from each scan performed. Overall, compressed sensing has significant clinical impact in improving the diagnostic quality and patient exp…
▽ More
Compressed sensing in MRI enables high subsampling factors while maintaining diagnostic image quality. This technique enables shortened scan durations and/or improved image resolution. Further, compressed sensing can increase the diagnostic information and value from each scan performed. Overall, compressed sensing has significant clinical impact in improving the diagnostic quality and patient experience for imaging exams. However, a number of challenges exist when moving compressed sensing from research to the clinic. These challenges include hand-crafted image priors, sensitive tuning parameters, and long reconstruction times. Data-driven learning provides a solution to address these challenges. As a result, compressed sensing can have greater clinical impact. In this tutorial, we will review the compressed sensing formulation and outline steps needed to transform this formulation to a deep learning framework. Supplementary open source code in python will be used to demonstrate this approach with open databases. Further, we will discuss considerations in applying data-driven compressed sensing in the clinical setting.
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Deep Residual Network for Off-Resonance Artifact Correction with Application to Pediatric Body Magnetic Resonance Angiography with 3D Cones
Authors:
David Y Zeng,
Jamil Shaikh,
Dwight G Nishimura,
Shreyas S Vasanawala,
Joseph Y Cheng
Abstract:
Purpose: Off-resonance artifact correction by deep-learning, to facilitate rapid pediatric body imaging with a scan time efficient 3D cones trajectory. Methods: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of 30 pediatric magnetic resonance angiography exams. Each exam acquired a short-readout scan (1.18 ms +- 0.38) an…
▽ More
Purpose: Off-resonance artifact correction by deep-learning, to facilitate rapid pediatric body imaging with a scan time efficient 3D cones trajectory. Methods: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of 30 pediatric magnetic resonance angiography exams. Each exam acquired a short-readout scan (1.18 ms +- 0.38) and a long-readout scan (3.35 ms +- 0.74) at 3T. Short-readout scans, with longer scan times but negligible off-resonance blurring, were used as reference images and augmented with additional off-resonance for supervised training examples. Long-readout scans, with greater off-resonance artifacts but shorter scan time, were corrected by autofocus and Off-ResNet and compared to short-readout scans by normalized root-mean-square error (NRMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Scans were also compared by scoring on eight anatomical features by two radiologists, using analysis of variance with post-hoc Tukey's test. Reader agreement was determined with intraclass correlation. Results: Long-readout scans were on average 59.3% shorter than short-readout scans. Images from Off-ResNet had superior NRMSE, SSIM, and PSNR compared to uncorrected images across +-1kHz off-resonance (P<0.01). The proposed method had superior NRMSE over -677Hz to +1kHz and superior SSIM and PSNR over +-1kHz compared to autofocus (P<0.01). Radiologic scoring demonstrated that long-readout scans corrected with Off-ResNet were non-inferior to short-readout scans (P<0.01). Conclusion: The proposed method can correct off-resonance artifacts from rapid long-readout 3D cones scans to a non-inferior image quality compared to diagnostically standard short-readout scans.
△ Less
Submitted 28 September, 2018;
originally announced October 2018.
-
Clinically Deployed Distributed Magnetic Resonance Imaging Reconstruction: Application to Pediatric Knee Imaging
Authors:
Michael J. Anderson,
Jonathan I. Tamir,
Javier S. Turek,
Marcus T. Alley,
Theodore L. Willke,
Shreyas S. Vasanawala,
Michael Lustig
Abstract:
Magnetic resonance imaging is capable of producing volumetric images without ionizing radiation. Nonetheless, long acquisitions lead to prohibitively long exams. Compressed sensing (CS) can enable faster scanning via sub-sampling with reduced artifacts. However, CS requires significantly higher reconstruction computation, limiting current clinical applications to 2D/3D or limited-resolution dynami…
▽ More
Magnetic resonance imaging is capable of producing volumetric images without ionizing radiation. Nonetheless, long acquisitions lead to prohibitively long exams. Compressed sensing (CS) can enable faster scanning via sub-sampling with reduced artifacts. However, CS requires significantly higher reconstruction computation, limiting current clinical applications to 2D/3D or limited-resolution dynamic imaging. Here we analyze the practical limitations to T2 Shuffling, a four-dimensional CS-based acquisition, which provides sharp 3D-isotropic-resolution and multi-contrast images in a single scan. Our improvements to the pipeline on a single machine provide a 3x overall reconstruction speedup, which allowed us to add algorithmic changes improving image quality. Using four machines, we achieved additional 2.1x improvement through distributed parallelization. Our solution reduced the reconstruction time in the hospital to 90 seconds on a 4-node cluster, enabling its use clinically. To understand the implications of scaling this application, we simulated running our reconstructions with a multiple scanner setup typical in hospitals.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Highly Scalable Image Reconstruction using Deep Neural Networks with Bandpass Filtering
Authors:
Joseph Y. Cheng,
Feiyu Chen,
Marcus T. Alley,
John M. Pauly,
Shreyas S. Vasanawala
Abstract:
To increase the flexibility and scalability of deep neural networks for image reconstruction, a framework is proposed based on bandpass filtering. For many applications, sensing measurements are performed indirectly. For example, in magnetic resonance imaging, data are sampled in the frequency domain. The introduction of bandpass filtering enables leveraging known imaging physics while ensuring th…
▽ More
To increase the flexibility and scalability of deep neural networks for image reconstruction, a framework is proposed based on bandpass filtering. For many applications, sensing measurements are performed indirectly. For example, in magnetic resonance imaging, data are sampled in the frequency domain. The introduction of bandpass filtering enables leveraging known imaging physics while ensuring that the final reconstruction is consistent with actual measurements to maintain reconstruction accuracy. We demonstrate this flexible architecture for reconstructing subsampled datasets of MRI scans. The resulting high subsampling rates increase the speed of MRI acquisitions and enable the visualization rapid hemodynamics.
△ Less
Submitted 26 November, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
Development and Clinical Implementation of Next Generation Very Light Weight and Extremely Flexible Receiver Arrays for Pediatric MRI
Authors:
Shreyas S. Vasanawala,
Robert Stormont,
Scott Lindsay,
Thomas Grafendorfer,
Joseph Y. Cheng,
John M. Pauly,
Greig Scott,
Jorge X. Guzman,
Victor Taracila,
Dan Chirayath,
Fraser Robb
Abstract:
We develop a novel next generation light-weight highly flexible pediatric coil array, combine it with a high-density pediatric posterior array or conventional posterior phased array, and determine feasibility of pediatric clinical use. A highly flexible 16 element MRI receiver coil was constructed with low-profile noise controlling preamplifiers that minimized reactive and resistive coupling. Elem…
▽ More
We develop a novel next generation light-weight highly flexible pediatric coil array, combine it with a high-density pediatric posterior array or conventional posterior phased array, and determine feasibility of pediatric clinical use. A highly flexible 16 element MRI receiver coil was constructed with low-profile noise controlling preamplifiers that minimized reactive and resistive coupling. Element decoupling was assessed in flat and highly flexed states. With IRB approval and informed consent and assent, 24 consecutive subjects undergoing torso or extremity MRI were prospectively recruited. Care team members were surveyed on preference for the coil versus conventional coils and diagnostic acceptability of the images was recorded. Confidence interval of proportion of diagnostic exams was calculated. The array without cable weighed 480 grams, demonstrated good flexibility while maintaining element decoupling. The coil was preferred by all nurses and anesthesiologists involved in the care of the patients. Technologists preferred the coil in 96 percent of cases, and 23 of 24 exams were diagnostically adequate with 85 percent confidence interval of 90-100 percent. Light-weight highly flexible coil arrays can be constructed that maintain element decoupling. Pediatric clinical image quality is likely to be diagnostic, with acceptance by members of the care team.
△ Less
Submitted 29 April, 2017;
originally announced May 2017.