A verified and validated moving domain CFD solver with applications to cardiovascular flows
Authors:
Henrik A. Kjeldsberg,
Joakim Sundnes,
Kristian Valen-Sendstad
Abstract:
Computational fluid dynamics (CFD) in combination with patient-specific medical images has been used to correlate flow phenotypes with disease initiation, progression and outcome, in search of a prospective clinical tool. A large number of CFD software packages are available, but are typically based on rigid domains and low-order finite volume methods, and are often implemented in massive low-leve…
▽ More
Computational fluid dynamics (CFD) in combination with patient-specific medical images has been used to correlate flow phenotypes with disease initiation, progression and outcome, in search of a prospective clinical tool. A large number of CFD software packages are available, but are typically based on rigid domains and low-order finite volume methods, and are often implemented in massive low-level C++ libraries. Furthermore, only a handful of solvers have been appropriately verified and validated for their intended use. Our goal was to develop, verify and validate an open-source CFD solver for moving domains, with applications to cardiovascular flows. The solver is an extension of the CFD solver Oasis, which is based on the finite element method and implemented using the FEniCS open source framework. The new solver, named OasisMove, extends Oasis by expressing the Navier-Stokes equations in the arbitrary Lagrangian-Eulerian formulation, which is suitable for handling moving domains. For code verification we used the method of manufactured solutions for a moving 2D vortex problem, and for validation we compared our results against existing high-resolution simulations and laboratory experiments for two moving domain problems of varying complexity. Verification results showed that the $L_2$ error followed the theoretical convergence rates. The temporal accuracy was second-order, while the spatial accuracy was second- and third-order using P1/P1 and P2/P1 finite elements, respectively. Validation results showed good agreement with existing benchmark results, by reproducing lift and drag coefficients with less than 1% error, and demonstrating the solver's ability to capture vortex patterns in transitional and turbulent-like flow regimes. In conclusion, we have shown that OasisMove is an open-source, accurate and reliable solver for cardiovascular flows in moving domains.
△ Less
Submitted 24 May, 2023;
originally announced May 2023.
On The Importance of Fundamental Computational Fluid Dynamics Towards a Robust and Reliable Model of Left Atrial Flows: Is There More Than Meets the Eye?
Authors:
Ehsan Khalili,
C'ecile Daversin-Catty,
Andy L. Olivares,
Jordi Mill,
Oscar Camara,
Kristian Valen-Sendstad
Abstract:
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) ve…
▽ More
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively. CFD simulations on 12 patient-specific left atrial geometries, obtained from computed tomography scans, were performed by using a second-order accurate and space/time centered solver. The convergence studies showed an average variability of around 30\% and 55\% for time averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP), even between intermediate spatial and temporal resolutions, in the left atrium (LA) and left atrial appendage (LAA), respectively. The comparison between HR and NR simulations showed good correlation in the LA for WSS, RRT, and ECAP (R^2 > 0.9), but not for OSI (R^2 = 0.63). However, there were poor correlations in the LAA especially for OSI, RRT, and ECAP (R^2 = 0.55, 0.63, and 0.61, respectively), except for WSS (R^2 = 0.81). The errors are comparable to differences previously reported with disease correlations. To robustly predict atrial hemodynamics and stresses, numerical resolutions of 10M elements and 10k time-steps per cycle seem necessary (i.e., one order of magnitude higher than normally used in both space and time). In conclusion, attention to fundamental numerical aspects is essential towards establishing a plausible, robust, and reliable model of LA flows.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.