-
The energy dependence of cluster size and its physical processes in the proton measurement with TimePix3 silicon detector
Authors:
Naoki Itoh,
Hugo Allaire,
Tokihiro Ikeda,
Shunsaku Nagasawa,
Shinji Okada,
Tadayuki Takahashi,
Aiko Takamine,
Yuichi Toyama,
Yuusuke Uchida,
Hideki Ueno
Abstract:
We investigated the energy dependence of the number of triggered pixels, or cluster size, when charged particles are detected using the TimePix3 detector with a silicon sensor. We measured protons in the range of 1.5~3.3 MeV from a Pelletron accelerator at RIKEN using a TimePix3 detector with a 500 um-thick silicon sensor. We determined from the experimental results a cluster size comprised betwee…
▽ More
We investigated the energy dependence of the number of triggered pixels, or cluster size, when charged particles are detected using the TimePix3 detector with a silicon sensor. We measured protons in the range of 1.5~3.3 MeV from a Pelletron accelerator at RIKEN using a TimePix3 detector with a 500 um-thick silicon sensor. We determined from the experimental results a cluster size comprised between 30 and 80 pixels. To understand the physical process that produces large cluster images and its energy dependence, we simulated the charge carrier drifts in the sensor, assuming the incidence of a proton in the detector. The cluster sizes estimated in the simulation were smaller than those observed in the experiment, and remained constant across the entire energy range, when thermal diffusion and charge carriers self-repulsion were considered as the factors of the cluster image formation. In addition, we discovered that the size of the cluster image and its energy dependence observed in the experiment could be well explained when considering that the TimePix3 detector is sensitive to the transient induced charges, allowing even pixels that do not collect the charge carriers to trigger. We conclude that the cluster size measurement is a promising method for evaluating the energy deposited by a charged particle in the TimePix3 detector.
△ Less
Submitted 19 January, 2025;
originally announced January 2025.
-
Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
Authors:
S. Go,
Y. Tsuzuki,
H. Yoneda,
Y. Ichikawa,
T. Ikeda,
N. Imai,
K. Imamura,
M. Niikura,
D. Nishimura,
R. Mizuno,
S. Takeda,
H. Ueno,
S. Watanabe,
T. Y. Saito,
S. Shimoura,
S. Sugawara,
A. Takamine,
T. Takahashi
Abstract:
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdT…
▽ More
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdTe) Compton camera can be a state-of-the-art gamma-ray polarimeter for nuclear spectroscopy with the high position sensitivity and the detection efficiency. We demonstrated the capability to operate this detector as a reliable gamma-ray polarimeter by using polarized 847-keV gamma rays produced by the $^{56}\rm{Fe}({\it p},{\it p'}γ)$ reaction. By combining the experimental data and simulated calculations, the modulation curve for the gamma ray was successfully obtained. A remarkably high polarization sensitivity was achieved, compatible with a reasonable detection efficiency. Based on the obtained results, a possible future gamma-ray polarimetery is discussed.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
The 17 April 2021 widespread solar energetic particle event
Authors:
N. Dresing,
L. Rodríguez-García,
I. C. Jebaraj,
A. Warmuth,
S. Wallace,
L. Balmaceda,
T. Podladchikova,
R. D. Strauss,
A. Kouloumvakos,
C. Palmroos,
V. Krupar,
J. Gieseler,
Z. Xu,
J. G. Mitchell,
C. M. S. Cohen,
G. A. de Nolfo,
E. Palmerio,
F. Carcaboso,
E. K. J. Kilpua,
D. Trotta,
U. Auster,
E. Asvestari,
D. da Silva,
W. Dröge,
T. Getachew
, et al. (24 additional authors not shown)
Abstract:
Context. A solar eruption on 17 April 2021 produced a widespread Solar Energetic Particle (SEP) event that was observed by five longitudinally well-separated observers in the inner heliosphere at heliocentric distances of 0.42 to 1 au: BepiColombo, Parker Solar Probe, Solar Orbiter, STEREO A, and near-Earth spacecraft. The event produced relativistic electrons and protons. It was associated with a…
▽ More
Context. A solar eruption on 17 April 2021 produced a widespread Solar Energetic Particle (SEP) event that was observed by five longitudinally well-separated observers in the inner heliosphere at heliocentric distances of 0.42 to 1 au: BepiColombo, Parker Solar Probe, Solar Orbiter, STEREO A, and near-Earth spacecraft. The event produced relativistic electrons and protons. It was associated with a long-lasting solar hard X-ray flare and a medium fast Coronal Mass Ejection (CME) with a speed of 880 km/s driving a shock, an EUV wave as well as long-lasting radio burst activity showing four distinct type III burst. Methods. A multi-spacecraft analysis of remote-sensing and in-situ observations is applied to attribute the SEP observations at the different locations to the various potential source regions at the Sun. An ENLIL simulation is used to characterize the interplanetary state and its role for the energetic particle transport. The magnetic connection between each spacecraft and the Sun is determined. Based on a reconstruction of the coronal shock front we determine the times when the shock establishes magnetic connections with the different observers. Radio observations are used to characterize the directivity of the four main injection episodes, which are then employed in a 2D SEP transport simulation. Results. Timing analysis of the inferred SEP solar injection suggests different source processes being important for the electron and the proton event. Comparison among the characteristics and timing of the potential particle sources, such as the CME-driven shock or the flare, suggests a stronger shock contribution for the proton event and a more likely flare-related source of the electron event. Conclusions. We find that in this event an important ingredient for the wide SEP spread was the wide longitudinal range of about 110 degrees covered by distinct SEP injections.
△ Less
Submitted 20 March, 2023;
originally announced March 2023.
-
Development of co-located ${}^{129}$Xe and ${}^{131}$Xe nuclear spin masers with external feedback scheme
Authors:
T. Sato,
Y. Ichikawa,
S. Kojima,
C. Funayama,
S. Tanaka,
T. Inoue,
A. Uchiyama,
A. Gladkov,
A. Takamine,
Y. Sakamoto,
Y. Ohtomo,
C. Hirao,
M. Chikamori,
E. Hikota,
T. Suzuki,
M. Tsuchiya,
T. Furukawa,
A. Yoshimi,
C. P. Bidinosti,
T. Ino,
H. Ueno,
Y. Matsuo,
T. Fukuyama,
N. Yoshinaga,
Y. Sakemi
, et al. (1 additional authors not shown)
Abstract:
We report on the operation of co-located ${}^{129}$Xe and ${}^{131}$Xe nuclear spin masers with an external feedback scheme, and discuss the use of ${}^{131}$Xe as a comagnetometer in measurements of the ${}^{129}$Xe spin precession frequency. By applying a correction based on the observed change in the ${}^{131}$Xe frequency, the frequency instability due to magnetic field and cell temperature dr…
▽ More
We report on the operation of co-located ${}^{129}$Xe and ${}^{131}$Xe nuclear spin masers with an external feedback scheme, and discuss the use of ${}^{131}$Xe as a comagnetometer in measurements of the ${}^{129}$Xe spin precession frequency. By applying a correction based on the observed change in the ${}^{131}$Xe frequency, the frequency instability due to magnetic field and cell temperature drifts are eliminated by two orders of magnitude. The frequency precision of 6.2 $μ$Hz is obtained for a 10$^4$ s averaging time, suggesting the possibility of future improvement to $\approx$ 1 nHz by improving the signal-to-noise ratio of the observation.
△ Less
Submitted 19 March, 2018;
originally announced March 2018.
-
DHCAL with Minimal Absorber: Measurements with Positrons
Authors:
The CALICE Collaboration,
B. Freund,
C. Neubüser,
J. Repond,
J. Schlereth,
L. Xia,
A. Dotti,
C. Grefe,
V. Ivantchenko,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg,
A. Irles,
F. Krivan,
K. Krüger
, et al. (78 additional authors not shown)
Abstract:
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on…
▽ More
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Hybrid ECAL: Optimization and Related Developments
Authors:
T. Suehara,
H. Hirai,
H. Sumida,
H. Ueno,
Y. Sudo,
T. Yoshioka,
K. Kawagoe
Abstract:
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high granularity and robust measurement of electromagnetic shower, and scintillator-tungsten ECAL, which gives affordable cost with similar performance to silicon. Opt…
▽ More
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high granularity and robust measurement of electromagnetic shower, and scintillator-tungsten ECAL, which gives affordable cost with similar performance to silicon. Optimization and a data acquisition trial in a test bench for the hybrid ECAL are described in this article.
△ Less
Submitted 30 March, 2015;
originally announced March 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
A study of silicon sensor for ILD ECAL
Authors:
Tatsuhiko Tomita,
Shion Chen,
Daniel Jeans,
Yoshio Kamiya,
Kiyotomo Kawagoe,
Sachio Komamiya,
Chihiro Kozakai,
Yohei Miyazaki,
Taikan Suehara,
Yuji Sudo,
Hiraku Ueno,
Tamaki Yoshioka
Abstract:
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability to separate nearby particles within jets. PFA requires calorimeters with high granularity. The ILD Electromagnetic Calorimeter (ECAL) is a sampling calorimeter…
▽ More
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability to separate nearby particles within jets. PFA requires calorimeters with high granularity. The ILD Electromagnetic Calorimeter (ECAL) is a sampling calorimeter with thirty tungsten absorber layers. The total thickness of this ECAL is about 24 X$_0$, and it has between 10 and 100 million channels to make high granularity. Silicon sensors are a candidate technology for the sensitive layers of this ECAL. Present prototypes of these sensors have 256 5.5$\times$5.5 mm$^2$ pixels in an area of 9$\times$9 cm$^2$.We have measured various properties of these prototype sensors: the leakage current, capacitance, and full depletion voltage. We have also examined the response to an infrared laser to understand the sensor's response at its edge and between pixel readout pads, as well the effect of different guard ring designs. In this paper, we show results from these measurements and discuss future works.
△ Less
Submitted 31 March, 2014;
originally announced March 2014.
-
Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope
Authors:
H. Kubo,
R. Paoletti,
Y. Awane,
A. Bamba,
M. Barcelo,
J. A. Barrio,
O. Blanch,
J. Boix,
C. Delgado,
D. Fink,
D. Gascon,
S. Gunji,
R. Hagiwara,
Y. Hanabata,
K. Hatanaka,
M. Hayashida,
M. Ikeno,
S. Kabuki,
H. Katagiri,
J. Kataoka,
Y. Konno,
S. Koyama,
T. Kishimoto,
J. Kushida,
G. Martinez
, et al. (29 additional authors not shown)
Abstract:
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact,…
▽ More
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.
△ Less
Submitted 12 July, 2013;
originally announced July 2013.
-
Recovery of state-specific potential of molecular motor from single-molecule trajectory
Authors:
Shoichi Toyabe,
Hiroshi Ueno,
Eiro Muneyuki
Abstract:
We have developed a novel method to evaluate the potential profile of a molecular motor at each chemical state from only the probe's trajectory and applied it to a rotary molecular motor F$_1$-ATPase. By using this method, we could also obtain the information regarding the mechanochemical coupling and energetics. We demonstrate that the position-dependent transition of the chemical states is the k…
▽ More
We have developed a novel method to evaluate the potential profile of a molecular motor at each chemical state from only the probe's trajectory and applied it to a rotary molecular motor F$_1$-ATPase. By using this method, we could also obtain the information regarding the mechanochemical coupling and energetics. We demonstrate that the position-dependent transition of the chemical states is the key feature for the highly efficient free-energy transduction by F$_1$-ATPase.
△ Less
Submitted 1 December, 2011;
originally announced December 2011.