-
Stable beam operation of approximately 1 mA beam under highly efficient energy recovery conditions at compact energy-recovery linac
Authors:
Hiroshi Sakai,
Dai Arakawa,
Takaaki Furuya,
Kaiichi Haga,
Masayuki Hagiwara,
Kentaro Harada,
Yosuke Honda,
Teruya Honma,
Eiji Kako,
Ryukou Kato,
Yuuji Kojima,
Taro Konomi,
Hiroshi Matsumura,
Taichi Miura,
Takako Miura,
Shinya Nagahashi,
Hirotaka Nakai,
Norio Nakamura,
Kota Nakanishi,
Kazuyuki Nigorikawa,
Takashi Nogami,
Takashi Obina,
Feng Qiu,
Hidenori Sagehashi,
Shogo Sakanaka
, et al. (15 additional authors not shown)
Abstract:
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the desi…
▽ More
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the design of ideal beam transport optics, we have successfully established approximately 1 mA stable CW operation with a small beam emittance and extremely small beam loss. This study presents the details of our key technologies and experimental results for achieving 100% energy recovery operation with extremely small beam loss during a stable, approximately 1 mA CW beam operation.
△ Less
Submitted 24 August, 2024;
originally announced August 2024.
-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Unsupervised Learning Architecture for Classifying the Transient Noise of Interferometric Gravitational-wave Detectors
Authors:
Yusuke Sakai,
Yousuke Itoh,
Piljong Jung,
Keiko Kokeyama,
Chihiro Kozakai,
Katsuko T. Nakahira,
Shoichi Oshino,
Yutaka Shikano,
Hirotaka Takahashi,
Takashi Uchiyama,
Gen Ueshima,
Tatsuki Washimi,
Takahiro Yamamoto,
Takaaki Yokozawa
Abstract:
In the data obtained by laser interferometric gravitational wave detectors, transient noise with non-stationary and non-Gaussian features occurs at a high rate. This often results in problems such as detector instability and the hiding and/or imitation of gravitational-wave signals. This transient noise has various characteristics in the time--frequency representation, which is considered to be as…
▽ More
In the data obtained by laser interferometric gravitational wave detectors, transient noise with non-stationary and non-Gaussian features occurs at a high rate. This often results in problems such as detector instability and the hiding and/or imitation of gravitational-wave signals. This transient noise has various characteristics in the time--frequency representation, which is considered to be associated with environmental and instrumental origins. Classification of transient noise can offer clues for exploring its origin and improving the performance of the detector. One approach for accomplishing this is supervised learning. However, in general, supervised learning requires annotation of the training data, and there are issues with ensuring objectivity in the classification and its corresponding new classes. By contrast, unsupervised learning can reduce the annotation work for the training data and ensure objectivity in the classification and its corresponding new classes. In this study, we propose an unsupervised learning architecture for the classification of transient noise that combines a variational autoencoder and invariant information clustering. To evaluate the effectiveness of the proposed architecture, we used the dataset (time--frequency two-dimensional spectrogram images and labels) of the Laser Interferometer Gravitational-wave Observatory (LIGO) first observation run prepared by the Gravity Spy project. The classes provided by our proposed unsupervised learning architecture were consistent with the labels annotated by the Gravity Spy project, which manifests the potential for the existence of unrevealed classes.
△ Less
Submitted 15 June, 2022; v1 submitted 19 November, 2021;
originally announced November 2021.
-
Construction and Commissioning of Mid-Infrared SASE FEL at cERL
Authors:
Yosuke Honda,
Masahiro Adachi,
Shu Eguchi,
Masafumi Fukuda,
Ryoichi Hajima,
Nao Higashi,
Masayuki Kakehata,
Ryukou Kato,
Takako Miura,
Tsukasa Miyajima,
Shinya Nagahashi,
Norio Nakamura,
Kazuyuki Nigorikawa,
Takashi Nogami,
Takashi Obina,
Hidenori Sagehashi,
Hiroshi Sakai,
Tadatake Sato,
Miho Shimada,
Tatsuro Shioya,
Ryota Takai,
Olga Tanaka,
Yasunori Tanimoto,
Kimichika Tsuchiya,
Takashi Uchiyama
, et al. (4 additional authors not shown)
Abstract:
The mid-infrared range is an important spectrum range where materials exhibit a characteristic response corresponding to their molecular structure. A free-electron laser (FEL) is a promising candidate for a high-power light source with wavelength tunability to investigate the nonlinear response of materials. Although the self-amplification spontaneous emission (SASE) scheme is not usually adopted…
▽ More
The mid-infrared range is an important spectrum range where materials exhibit a characteristic response corresponding to their molecular structure. A free-electron laser (FEL) is a promising candidate for a high-power light source with wavelength tunability to investigate the nonlinear response of materials. Although the self-amplification spontaneous emission (SASE) scheme is not usually adopted in the mid-infrared wavelength range, it may have advantages such as layout simplicity, the possibility of producing a single pulse, and scalability to a short-wavelength facility. To demonstrate the operation of a mid-infrared SASE FEL system in an energy recovery linac (ERL) layout, we constructed an SASE FEL setup in cERL, a test facility of the superconducting linac with the ERL configuration. Despite the adverse circumstance of space charge effects due to the given boundary condition of the facility, we successfully established the beam condition at the undulators, and observed FEL emission at a wavelength of 20 $μ$m. The results show that the layout of cERL has the potential for serving as a mid-infrared light source.
△ Less
Submitted 24 June, 2021;
originally announced June 2021.
-
Investigation of crackling noise in the vibration isolation systems of the KAGRA gravitational wave detector
Authors:
Yuhang Zhao,
Shin Kirii,
Yingtao Liu,
Takashi Uchiyama,
Ryutaro Takahashi,
Seiji Kawamura
Abstract:
Gravitational wave detectors, such as KAGRA, require complex mirror suspension systems to reach high sensitivity. One particular concern in these suspensions is the presence of crackling noise, where motion of the steel crystal structure disturbs material defects, causing impulse force release and exciting mirror motion. Crackling in the Geometric Anti Spring filters (GAS) in KAGRA's suspension sy…
▽ More
Gravitational wave detectors, such as KAGRA, require complex mirror suspension systems to reach high sensitivity. One particular concern in these suspensions is the presence of crackling noise, where motion of the steel crystal structure disturbs material defects, causing impulse force release and exciting mirror motion. Crackling in the Geometric Anti Spring filters (GAS) in KAGRA's suspension system could introduce noise in the gravitational wave detection band. We investigate crackling noise in a miniature GAS with a low-frequency cyclical stress. We developed a scaling law between miniature and KAGRA GAS. Applying experimental results to the scaling law allows us to estimate the upper limit of crackling noise in KAGRA. It is found that crackling noise should be below the target sensitivity for gravitational waves above 60 Hz.
△ Less
Submitted 2 September, 2021; v1 submitted 1 September, 2020;
originally announced September 2020.
-
Demonstration of a dual-pass differential Fabry-Perot interferometer for future interferometric space gravitational wave antennas
Authors:
Koji Nagano,
Hiroki Takeda,
Yuta Michimura,
Takashi Uchiyama,
Masaki Ando
Abstract:
A dual-pass differential Fabry-Perot interferometer (DPDFPI) is one candidate of the interferometer configurations utilized in future Fabry-Perot type space gravitational wave antennas, such as Deci-hertz Interferometer Gravitational Wave Observatory. In this paper, the working principle of the DPDFPI has been investigated and necessity to adjust the absolute length of the cavity for the operation…
▽ More
A dual-pass differential Fabry-Perot interferometer (DPDFPI) is one candidate of the interferometer configurations utilized in future Fabry-Perot type space gravitational wave antennas, such as Deci-hertz Interferometer Gravitational Wave Observatory. In this paper, the working principle of the DPDFPI has been investigated and necessity to adjust the absolute length of the cavity for the operation of the DPDFPI has been found. In addition, using the 55-cm-long prototype, the operation of the DPDFPI has been demonstrated for the first time and it has been confirmed that the adjustment of the absolute arm length reduces the cavity detuning as expected. This work provides the proof of concept of the DPDFPI for application to the future Fabry-Perot type space gravitational wave antennas.
△ Less
Submitted 27 August, 2020;
originally announced August 2020.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
High-efficiency broadband THz emission via diffraction-radiation cavity
Authors:
Yosuke Honda,
Miho Shimada,
Alexander Aryshev,
Ryukou Kato,
Tsukasa Miyajima,
Takashi Obina,
Ryota Takai,
Takashi Uchiyama,
Naoto Yamamoto
Abstract:
Accelerator-based terahertz (THz) radiation has been expected to realize a high-power broadband source. Employing a low-emittance and short-bunch electron beam at a high repetition rate, a scheme of coherent diffraction-radiation in an optical cavity layout is proposed. The scheme's stimulated radiation process between bunches can greatly enhance the efficiency of the radiation emission. We perfor…
▽ More
Accelerator-based terahertz (THz) radiation has been expected to realize a high-power broadband source. Employing a low-emittance and short-bunch electron beam at a high repetition rate, a scheme of coherent diffraction-radiation in an optical cavity layout is proposed. The scheme's stimulated radiation process between bunches can greatly enhance the efficiency of the radiation emission. We performed an experiment with a superconducting linac constructed as an energy recovery linac (ERL) test facility. The electron beam passes through small holes in the cavity mirrors without being destroyed. A sharp THz resonance signal, which indicates broadband stimulated radiation correlated with beam deceleration, was observed while scanning the round-trip length of the cavity. This observation proves the efficient beam-to-radiation energy conversion due to the stimulated radiation process.
△ Less
Submitted 20 February, 2019;
originally announced February 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient damping performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the damping performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Stimulated excitation of an optical cavity by a multi-bunch electron beam via coherent diffraction radiation process
Authors:
Yosuke Honda,
Miho Shimada,
Alexander Aryshev,
Ryukou Kato,
Tsukasa Miyajima,
Takashi Obina,
Ryota Takai,
Takashi Uchiyama,
Naoto Yamamoto
Abstract:
With a low emittance and short-bunch electron beam at a high repetition rate realized by a superconducting linac, stimulated excitation of an optical cavity at the terahertz spectrum range has been shown. The electron beam passed through small holes in the cavity mirrors without being destroyed. A sharp resonance structure which indicated wide-band stimulated emission via coherent diffraction radi…
▽ More
With a low emittance and short-bunch electron beam at a high repetition rate realized by a superconducting linac, stimulated excitation of an optical cavity at the terahertz spectrum range has been shown. The electron beam passed through small holes in the cavity mirrors without being destroyed. A sharp resonance structure which indicated wide-band stimulated emission via coherent diffraction radiation was observed while scanning the round-trip length of the cavity.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
The status of KAGRA underground cryogenic gravitational wave telescope
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
M. A. Barton,
K. Cannon,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
Y. Fujii,
M. -K. Fujimoto,
T. Furuhata,
S. Haino,
K. Hasegawa,
K. Hashino,
K. Hayama,
S. Hirobayashi
, et al. (126 additional authors not shown)
Abstract:
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial ph…
▽ More
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope
Authors:
Yuta Michimura,
Tomofumi Shimoda,
Takahiro Miyamoto,
Ayaka Shoda,
Koki Okutomi,
Yoshinori Fujii,
Hiroki Tanaka,
Mark A. Barton,
Ryutaro Takahashi,
Yoichi Aso,
Tomotada Akutsu,
Masaki Ando,
Yutaro Enomoto,
Raffaele Flaminio,
Kazuhiro Hayama,
Eiichi Hirose,
Yuki Inoue,
Takaaki Kajita,
Masahiro Kamiizumi,
Seiji Kawamura,
Keiko Kokeyama,
Kentaro Komori,
Rahul Kumar,
Osamu Miyakawa,
Koji Nagano
, et al. (14 additional authors not shown)
Abstract:
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and vari…
▽ More
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.
△ Less
Submitted 21 June, 2019; v1 submitted 8 September, 2017;
originally announced September 2017.
-
A Study of Cooling Time Reduction of Interferometric Cryogenic Gravitational Wave Detectors Using a High-Emissivity Coating
Authors:
Y. Sakakibara,
N. Kimura,
T. Suzuki,
K. Yamamoto,
D. Chen,
S. Koike,
C. Tokoku,
T. Uchiyama,
M. Ohashi,
K. Kuroda
Abstract:
In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity co…
▽ More
In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity coating (e.g. a diamond-like carbon (DLC) coating) can reduce the cooling time effectively by enhancing radiation heat transfer. Here, we have experimentally verified the effect of the DLC coating on the reduction of the cooling time.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector
Authors:
Takashi Uchiyama,
Shinji Miyoki,
Souichi Telada,
Kazuhiro Yamamoto,
Masatake Ohashi,
Kazuhiro Agatsuma,
Koji Arai,
Masa-Katsu Fujimoto,
Tomiyoshi Haruyama,
Seiji Kawamura,
Osamu Miyakawa,
Naoko Ohishi,
Takanori Saito,
Takakazu Shintomi,
Toshikazu Suzuki,
Ryutaro Takahashi,
Daisuke Tatsumi
Abstract:
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's…
▽ More
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}/\sqrt{\textrm{Hz}}$ at 165\,Hz.
△ Less
Submitted 16 February, 2012;
originally announced February 2012.
-
Effect of energy deposited by cosmic-ray particles on interferometric gravitational wave detectors
Authors:
Kazuhiro Yamamoto,
Hideaki Hayakawa,
Atsushi Okada,
Takashi Uchiyama,
Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Nobuyuki Kanda,
Daisuke Tatsumi,
Yoshiki Tsunesada
Abstract:
We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravi…
▽ More
We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravitational wave detectors. The power spectral density of vibrations caused by low-energy secondary muons is 100-times smaller than the goal sensitivity of future second-generation interferometer projects, such as LCGT and Advanced LIGO. The arrival frequency of high-energy cosmic-ray muons that generate enough large showers inside mirrors of LCGT and Advanced LIGO is one per a millennium. We also discuss the probability of exotic-particle detection with interferometers.
△ Less
Submitted 3 August, 2008; v1 submitted 15 May, 2008;
originally announced May 2008.
-
Parametric instabilities in the LCGT arm cavity
Authors:
K Yamamoto,
T Uchiyama,
S Miyoki,
M Ohashi,
K Kuroda,
K Numata
Abstract:
We evaluated the parametric instabilities of LCGT (Japanese interferometric gravitational wave detector project) arm cavity. The number of unstable modes of LCGT is 10-times smaller than that of Advanced LIGO (U.S.A.). Since the strength of the instabilities of LCGT depends on the mirror curvature more weakly than that of Advanced LIGO, the requirement of the mirror curvature accuracy is easier…
▽ More
We evaluated the parametric instabilities of LCGT (Japanese interferometric gravitational wave detector project) arm cavity. The number of unstable modes of LCGT is 10-times smaller than that of Advanced LIGO (U.S.A.). Since the strength of the instabilities of LCGT depends on the mirror curvature more weakly than that of Advanced LIGO, the requirement of the mirror curvature accuracy is easier to be achieved. The difference in the parametric instabilities between LCGT and Advanced LIGO is because of the thermal noise reduction methods (LCGT, cooling sapphire mirrors; Advanced LIGO, fused silica mirrors with larger laser beams), which are the main strategies of the projects. Elastic Q reduction by the barrel surface (0.2 mm thickness Ta$_2$O$_5$) coating is effective to suppress instabilities in the LCGT arm cavity. Therefore, the cryogenic interferometer is a smart solution for the parametric instabilities in addition to thermal noise and thermal lensing.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Current status of the CLIO project
Authors:
K Yamamoto,
T Uchiyama,
S Miyoki,
M Ohashi,
K Kuroda,
H Ishitsuka,
T Akutsu,
S Telada,
T Tomaru,
T Suzuki,
N Sato,
Y Saito,
Y Higashi,
T Haruyama,
A Yamamoto,
T Shintomi,
D Tatsumi,
M Ando,
H Tagoshi,
N Kanda,
N Awaya,
S Yamagishi,
H Takahashi,
A Araya,
A Takamori
, et al. (5 additional authors not shown)
Abstract:
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temper…
▽ More
CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temperature experiments) is introduced in this article. In a room-temperature experiment, we made efforts to improve the sensitivity. The current best sensitivity at 300 K is about $6 \times 10^{-21} /\sqrt{\rm Hz}$ around 400 Hz. Below 20 Hz, the strain (not displacement) sensitivity is comparable to that of LIGO, although the baselines of CLIO are 40-times shorter (CLIO: 100m, LIGO: 4km). This is because seismic noise is extremely small in Kamioka mine. We operated the interferometer at room temperature for gravitational wave observations. We obtained 86 hours of data. In the cryogenic experiment, it was confirmed that the mirrors were sufficiently cooled (14 K). However, we found that the radiation shield ducts transferred 300K radiation into the cryostat more effectively than we had expected. We observed that noise caused by pure aluminum wires to suspend a mirror was suppressed by cooling the mirror.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector
Authors:
Takayuki Tomaru,
Masao Tokunari,
Kazuaki Kuroda,
Takashi Uchiyama,
Akira Okutomi,
Masatake Ohashi,
Hiroyuki Kirihara,
Nobuhiro Kimura,
Yoshio Saito,
Nobuaki Sato,
Takakazu Shintomi,
Toshikazu Suzuki,
Tomiyoshi Haruyama,
Shinji Miyoki,
Kazuhiro Yamamoto,
Akira Yamamoto
Abstract:
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduc…
▽ More
A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.
△ Less
Submitted 6 November, 2007;
originally announced November 2007.
-
Thermal lensing in cryogenic sapphire substrates
Authors:
Takayuki Tomaru,
Toshikazu Suzuki,
Shinji Miyoki,
Takashi Uchiyama,
C. T. Taylor,
Akira Yamamoto,
Takakazu Shintomi,
Masatake Ohashi,
Kazuaki Kuroda
Abstract:
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryog…
▽ More
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryogenic temperature. On basis of these measurements, we estimated the shot noise sensitivity of the interferometer with thermal lensing by using a wave-front tracing simulation. We found that thermal lensing in cryogenic sapphire mirrors is negligible.
△ Less
Submitted 12 February, 2002;
originally announced February 2002.
-
Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope
Authors:
Takayuki Tomaru,
Takashi Uchiyama,
Daisuke Tatsumi,
Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Toshikazu Suzuki,
Akira Yamamoto,
Takakazu Shintomi
Abstract:
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
△ Less
Submitted 8 March, 2001; v1 submitted 17 January, 2001;
originally announced January 2001.