Advanced LIGO detector performance in the fourth observing run
Authors:
E. Capote,
W. Jia,
N. Aritomi,
M. Nakano,
V. Xu,
R. Abbott,
I. Abouelfettouh,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
S. K. Apple,
K. Arai,
S. M. Aston,
M. Ball,
S. W. Ballmer,
D. Barker,
L. Barsotti,
B. K. Berger,
J. Betzwieser,
D. Bhattacharjee,
G. Billingsley,
S. Biscans,
C. D. Blair,
N. Bode,
E. Bonilla
, et al. (171 additional authors not shown)
Abstract:
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron st…
▽ More
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.
△ Less
Submitted 21 November, 2024;
originally announced November 2024.
-
Demonstration of the minimal coupling of horizontal accelerations to rotations in a torsion balance suspended from three wires
Authors:
Amit Singh Ubhi,
Clive C. Speake,
Emilia Chick,
Conner Gettings
Abstract:
The Cavendish torsion balance is the instrument of choice for measuring weak forces, such as gravity. Although torsion balances have extremely high sensitivity for measuring forces over ranges of a few cm and more, their dynamics make it difficult to extend this range to much less than fractions of mm. In particular forces such as the Casimir force are usually studied using atomic force microscope…
▽ More
The Cavendish torsion balance is the instrument of choice for measuring weak forces, such as gravity. Although torsion balances have extremely high sensitivity for measuring forces over ranges of a few cm and more, their dynamics make it difficult to extend this range to much less than fractions of mm. In particular forces such as the Casimir force are usually studied using atomic force microscopes. We present results of our studies of a simple torsion balance with a 3-wire suspension. This device should be able to maintain parallelism between flat plates of areas of a few $\sim\mathrm{cm^2}$ at separations of much less of 10's of $\mathrm{μm}$. In this paper we describe our experimental investigation into the coupling of ground tilt to the torsional rotation of the novel device. We show that, like the Cavendish torsion balance, the 3-wire torsion balance is highly insensitive to tilts. We also demonstrate that this tilt sensitivity is itself insensitive to shifts in the centre of mass position of the suspended mass. We discuss simple models of the 3-wire torsion balance that show that it is only the static wire lengths that determine the coupling of tilts and horizontal accelerations. We also discuss designs of torsion balances where sensitivity and noise rejection to tilts are optimised.
△ Less
Submitted 20 November, 2024; v1 submitted 15 November, 2024;
originally announced November 2024.
-
Sensitivity and control of a 6-axis fused-silica seismometer
Authors:
Jiri Smetana,
Amit Singh Ubhi,
Emilia Chick,
Leonid Prokhorov,
John Bryant,
Artemiy Dmitriev,
Alex Gill,
Lari Koponen,
Haixing Miao,
Alan V. Cumming,
Giles Hammond,
Valery Frolov,
Richard Mittleman,
Peter Fritchel,
Denis Martynov
Abstract:
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band t…
▽ More
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band towards mHz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (LIGO) in improving their observation capability of intermediate-mass black holes ($\sim 1000\,M_\odot$). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fibre, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.
△ Less
Submitted 6 January, 2025; v1 submitted 22 May, 2024;
originally announced May 2024.
-
Design and sensitivity of a 6-axis seismometer for gravitational wave observatories
Authors:
Leonid Prokhorov,
Sam Cooper,
Amit Singh Ubhi,
Conor Mow-Lowry,
John Bryant,
Artemiy Dmitriev,
Chiara Di Fronzo,
Christopher J. Collins,
Alex Gill,
Alexandra Mitchell,
Joscha Heinze,
Jiri Smetana,
Tianliang Yan,
Alan V. Cumming,
Giles Hammond,
Denis Martynov
Abstract:
We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom.…
▽ More
We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force.
△ Less
Submitted 24 July, 2023;
originally announced July 2023.
-
Active platform stabilisation with a 6D seismometer
Authors:
Amit Singh Ubhi,
Leonid Prokhorov,
Sam Cooper,
Chiara Di Fronzo,
John Bryant,
David Hoyland,
Alexandra Mitchell,
Jesse van Dongen,
Conor Mow-Lowry,
Alan Cumming,
Giles Hammond,
Denis Martynov
Abstract:
We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the di…
▽ More
We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilise the platform in the frequency band from 250 mHz up to 10 Hz in the horizontal degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 μm). In this paper we discuss the 6D seismometer, its control scheme, and the limitations of the test bed.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Cryogenic optical shadow sensors for future gravitational wave detectors
Authors:
Amit Singh Ubhi,
John Bryant,
David Hoyland,
Denis Martynov
Abstract:
Displacement sensors have a variety of applications within gravitational wave detectors. The seismic isolation chain of the LIGO core optics utilises optical shadow sensors for their stabilisation. Future upgrades, such as LIGO Voyager, plan to operate at cryogenic temperatures to reduce their thermal noise and will require cryogenic displacement sensors. We present the results of simulations and…
▽ More
Displacement sensors have a variety of applications within gravitational wave detectors. The seismic isolation chain of the LIGO core optics utilises optical shadow sensors for their stabilisation. Future upgrades, such as LIGO Voyager, plan to operate at cryogenic temperatures to reduce their thermal noise and will require cryogenic displacement sensors. We present the results of simulations and experimental tests of the shadow sensors embedded in the Birmingham Optical Sensors and Electromagnetic Motors (BOSEMs). We determine that the devices can reliably viability operate at 100 K. We also show that the performance of the BOSEM sensors improves at cryogenic temperatures.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Compact Michelson interferometers with subpicometer sensitivity
Authors:
Jiri Smetana,
Rebecca Walters,
Sophie Bauchinger,
Amit Singh Ubhi,
Sam Cooper,
David Hoyland,
Richard Abbott,
Christoph Baune,
Peter Fritchel,
Oliver Gerberding,
Semjon Köhnke,
Haixing Miao,
Sebastian Rode,
Denis Martynov
Abstract:
The network of interferometric gravitational-wave observatories has successfully detected tens of astrophysical signals since 2015. In this paper, we experimentally investigate compact sensors that have the potential to improve the sensitivity of gravitational-wave detectors to intermediate-mass black holes. We use only commercial components, such as sensing heads and lasers, to assemble the setup…
▽ More
The network of interferometric gravitational-wave observatories has successfully detected tens of astrophysical signals since 2015. In this paper, we experimentally investigate compact sensors that have the potential to improve the sensitivity of gravitational-wave detectors to intermediate-mass black holes. We use only commercial components, such as sensing heads and lasers, to assemble the setup and demonstrate its subpicometer precision. The setup consists of a pair of Michelson interferferometers that use deep frequency modulation techniques to obtain a linear, relative displacement readout over multiple interference fringes. We implement a laser-frequency stabilisation scheme to achieve a sensitivity of 0.3\,$\text{pm} / \sqrt{\text{Hz}}$ above 0.1\,Hz. The device has also the potential to improve other experiments, such as torsion balances and commercial seismometers.
△ Less
Submitted 4 October, 2022; v1 submitted 21 February, 2022;
originally announced February 2022.
-
A six degree-of-freedom fused silica seismometer: Design and tests of a metal prototype
Authors:
Amit Singh Ubhi,
Jiri Smetana,
Teng Zhang,
Sam Cooper,
Leonid Prokhorov,
John Bryant,
David Hoyland,
Haixing Miao,
Denis Martynov
Abstract:
Ground vibrations couple to the longitudinal and angular motion of the aLIGO test masses and limit the observatory sensitivity below 30\,Hz. Novel inertial sensors have the potential to improve the aLIGO sensitivity in this band and simplify the lock acquisition of the detectors. In this paper, we experimentally study a compact 6D seismometer that consists of a mass suspended by a single wire. The…
▽ More
Ground vibrations couple to the longitudinal and angular motion of the aLIGO test masses and limit the observatory sensitivity below 30\,Hz. Novel inertial sensors have the potential to improve the aLIGO sensitivity in this band and simplify the lock acquisition of the detectors. In this paper, we experimentally study a compact 6D seismometer that consists of a mass suspended by a single wire. The position of the mass is interferometrically read out relative to the platform that supports the seismometer. We present the experimental results, discuss limitations of our metallic prototype, and show that a compact 6D seismometer made out of fused silica and suspended with a fused silica fibre has the potential to improve the aLIGO low frequency noise.
△ Less
Submitted 24 December, 2021; v1 submitted 16 September, 2021;
originally announced September 2021.
-
Enhancing interferometer sensitivity without sacrificing bandwidth and stability: beyond single-mode and resolved-sideband approximation
Authors:
Xiang Li,
Jiri Smetana,
Amit Singh Ubhi,
Joe Bentley,
Yanbei Chen,
Yiqiu Ma,
Haixing Miao,
Denis Martynov
Abstract:
Quantum noise limits the sensitivity of precision measurement devices, such as laser interferometer gravitational-wave observatories and axion detectors. In the shot-noise-limited regime, these resonant detectors are subject to a trade-off between the peak sensitivity and bandwidth. One approach to circumvent this limitation in gravitational-wave detectors is to embed an anomalous-dispersion optom…
▽ More
Quantum noise limits the sensitivity of precision measurement devices, such as laser interferometer gravitational-wave observatories and axion detectors. In the shot-noise-limited regime, these resonant detectors are subject to a trade-off between the peak sensitivity and bandwidth. One approach to circumvent this limitation in gravitational-wave detectors is to embed an anomalous-dispersion optomechanical filter to broaden the bandwidth. The original filter cavity design, however, makes the entire system unstable. Recently, we proposed the coherent feedback between the arm cavity and the optomechanical filter to eliminate the instability via PT-symmetry. The original analysis based upon the Hamiltonian formalism adopted the single-mode and resolved-sideband approximations. In this paper, we go beyond these approximations and consider realistic parameters. We show that the main conclusion concerning stability remains intact, with both Nyquist analysis and a detailed time-domain simulation.
△ Less
Submitted 6 April, 2021;
originally announced April 2021.