In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements
Authors:
Zhengheng Li,
Merlin Kole,
Jianchao Sun,
Liming Song,
Nicolas Produit,
Bobing Wu,
Tianwei Bao,
Tancredi Bernasconi,
Franck Cadoux,
Yongwei Dong,
Minzi Feng,
Neal Gauvin,
Wojtek Hajdas,
Hancheng Li,
Lu Li,
Xin Liu,
Radoslaw Marcinkowski,
Martin Pohl,
Dominik K. Rybka,
Haoli Shi,
Jacek Szabelski,
Teresa Tymieniecka,
Ruijie Wang,
Yuanhao Wang,
Xing Wen
, et al. (8 additional authors not shown)
Abstract:
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the…
▽ More
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the Chinese space laboratory TG-2 on 15th September, 2016. In order to reliably reconstruct the polarization information a highly detailed understanding of the instrument is required for both data analysis and Monte Carlo studies. For this purpose a full study of the in-orbit performance was performed in order to obtain the instrument calibration parameters such as noise, pedestal, gain nonlinearity of the electronics, threshold, crosstalk and gain, as well as the effect of temperature on the above parameters. Furthermore the relationship between gain and high voltage of the multi-anode photomultiplier tube has been studied and the errors on all measurement values are presented. Finally the typical systematic error on polarization measurements of Gamma-Ray Bursts due to the measurement error of the calibration parameters are estimated using Monte Carlo simulations.
△ Less
Submitted 28 May, 2018; v1 submitted 19 May, 2018;
originally announced May 2018.
Instrument Performance and Simulation Verification of the POLAR Detector
Authors:
M. Kole,
Z. H. Li,
N. Produit,
T. Tymieniecka,
J. Zhang,
A. Zwolinska,
T. W. Bao,
T. Bernasconi,
F. Cadoux,
M. Z. Feng,
N. Gauvin,
W. Hajdas,
S. W. Kong,
H. C. Li,
L. Li,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rybka,
J. C. Sun,
L. M. Song,
J. Szabelski,
R. J. Wang,
Y. H. Wang
, et al. (10 additional authors not shown)
Abstract:
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photo…
▽ More
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
△ Less
Submitted 2 August, 2017;
originally announced August 2017.