-
The stiffness of elastomeric surfaces influences the mechanical properties of endothelial cells
Authors:
Jagoba Iturri,
Julia Miholich,
Spela Zemljic,
Amsatou Andorfer-Sarr,
Rafael Benitez,
Jose L. Toca-Herrera
Abstract:
Optimal characterization of the mechanical properties of both cells and their surrounding is an issue of major interest. Indeed, cell function and development are strongly influenced by external stimuli. Furthermore, a change in cell mechanics might, in some cases, associate with diseases or malfunctioning. In this work, atomic force microscopy (AFM) was applied to examine the mechanical propertie…
▽ More
Optimal characterization of the mechanical properties of both cells and their surrounding is an issue of major interest. Indeed, cell function and development are strongly influenced by external stimuli. Furthermore, a change in cell mechanics might, in some cases, associate with diseases or malfunctioning. In this work, atomic force microscopy (AFM) was applied to examine the mechanical properties of the silicone elastomer polydimethylsiloxane (PDMS) a common substrate in cell culture. Force spectroscopy analysis was done over different specimens of this elastomeric material containing varying ratios of resin to cross-linker in its structure (5:1, 10:1, 20:1, 30:1 and 50:1), which impacts the final material properties (e.g., stiffness, elasticity). To quantify the mechanical properties of the PDMS, factors as the modulus of Young, the maximum adhesive forces as well as both relaxation amplitudes and times upon constant height contact of the tip (dwell time different of zero) were calculated from the different segments forming the force curves. It is demonstrated that the material stiffness is increased by prior oxygen plasma treatment of the sample, required for hydrophilic switching, contrarily to what observed for its adhesiveness. Subsequent incubation of endothelial HUVEC cells on top of these plasma treated PDMS systems yields minor variation in cell mechanics in comparison to those obtained on a glass reference, on which cells show much higher spreading tendency and, by extension, a remarkable membrane hardening. Thus, surface wettability turns a factor of higher relevance than substrate stiffness inducing variations in the cell mechanics.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
-
A probabilistic model for crystal growth applied to protein deposition at the microscale
Authors:
V. J. Bolós,
R. Benítez,
A. Eleta-López,
J. L. Toca-Herrera
Abstract:
A probabilistic discrete model for 2D protein crystal growth is presented. This model takes into account the available space and can describe growing processes of different nature due to the versatility of its parameters which gives the model great flexibility. The accuracy of the simulation is tested against a real protein (SbpA) crystallization experiment showing high agreement between the propo…
▽ More
A probabilistic discrete model for 2D protein crystal growth is presented. This model takes into account the available space and can describe growing processes of different nature due to the versatility of its parameters which gives the model great flexibility. The accuracy of the simulation is tested against a real protein (SbpA) crystallization experiment showing high agreement between the proposed model and the actual images of the nucleation process. Finally, it is also discussed how the regularity of the interface (i.e. the curve that separates the crystal from the substrate) affects to the evolution of the simulation.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Laser induced topological cues shape, guide, and anchor human Mesenchymal Stem Cells
Authors:
R. Ortiz,
S. Moreno-Flores,
I. Quintana,
MdM Vivanco,
J. R. Sarasua,
J. L. Toca-Herrera
Abstract:
This report focuses on the effect of the surface topography of the substrate on the behavior of human mesenchymal stem cells from bone marrow (MSCs) before and after co-differentiation into adipocytes and osteoblasts. Picosecond pulsed laser ablation technology was applied to generate different microstructures (microgrooves and microcavities) on poly (L-lactide) (PLLA), where orientation, cell sha…
▽ More
This report focuses on the effect of the surface topography of the substrate on the behavior of human mesenchymal stem cells from bone marrow (MSCs) before and after co-differentiation into adipocytes and osteoblasts. Picosecond pulsed laser ablation technology was applied to generate different microstructures (microgrooves and microcavities) on poly (L-lactide) (PLLA), where orientation, cell shape and MSCs co-differentiation were investigated. On flat PLLA, the undifferentiated MSCs showed rounded or elongated shapes, the latter being randomly oriented. On PLLA microgrooves however, MSCs adapted their shape to the groove size and direction and occasionally anchored to groove edges. It was found that adipocytes, contrary to osteoblasts, are highly sensitive to topological cues. Adipocytes responded to changes in substrate height and depth, by adapting the intracellular distribution of their lipid vacuoles to these physical constraints. In addition, the modification of PLLA by laser ablation enhanced the adherence of differentiated cells to the substrate. These findings show that picosecond pulsed laser micromachining can be applied to directly manufacture 3D microstructures that guide cell proliferation, control adipocyte morphology and improve the adhesion of bone and fat tissue.
△ Less
Submitted 25 January, 2018;
originally announced January 2018.
-
Stress relaxation and creep experiments with the atomic force microscope: a unified method to calculate elastic moduli and viscosities of biomaterials (and cells)
Authors:
Susana Moreno-Flores,
Rafael Benitez,
Maria dM Vivanco,
Jose Luis Toca-Herrera
Abstract:
We show that the atomic force microscope can perform stress relaxation and creep compliance measurements on living cells. We propose a method to obtain the mechanical properties of the studied biomaterial: the relaxation time, the elastic moduli and the viscosity.
We show that the atomic force microscope can perform stress relaxation and creep compliance measurements on living cells. We propose a method to obtain the mechanical properties of the studied biomaterial: the relaxation time, the elastic moduli and the viscosity.
△ Less
Submitted 3 March, 2010;
originally announced March 2010.
-
Stress relaxation microscopy (STREM): Imaging mechanical force decay in cells
Authors:
Susana Moreno-Flores,
Rafael Benitez,
Maria dM Vivanco,
Jose Luis Toca-Herrera
Abstract:
We have developed a novel scanning probe-based methodology to study cell biomechanics. The time dependence of the force exerted by the cell surface on a scanning probe at constant local deformation has been used to extract local relaxational responses. The generalized Maxwell viscoelastic model that accounts for multi relaxations fully describes the mechanical behaviour of the cell surface that…
▽ More
We have developed a novel scanning probe-based methodology to study cell biomechanics. The time dependence of the force exerted by the cell surface on a scanning probe at constant local deformation has been used to extract local relaxational responses. The generalized Maxwell viscoelastic model that accounts for multi relaxations fully describes the mechanical behaviour of the cell surface that exhibits a bimodal relaxation. Within the range of tested forces (0.1-4 nN) a slow and a fast relaxation with characteristic times of 0.1 and 1s have been detected and assigned to rearrangements in the cell membrane and cytoskeleton cortex, respectively. Relaxation time mapping allows to simultaneously detect non-uniformities in membrane and cytoskeletal mechanical behaviour and can be used as both identifying and diagnosing tools for cell type and cell disease.
△ Less
Submitted 17 April, 2009;
originally announced April 2009.
-
On the lipid-bacterial protein interaction studied by quartz crystal microbalance with dissipation, transmission electron microscopy and atomic force microscopy
Authors:
Mihaela Delcea,
Susana Moreno-Flores,
Dietmar Pum,
Uwe Bernd Sleytr,
Jose Luis Toca-Herrera
Abstract:
The interaction between the bacterial S-protein SbpA on different types of lipid membranes has been studied using atomic force microscopy, transmission electron microscopy, and quartz crystal microbalance with dissipation. On one hand, It has been found that the bacterial forms two dimensional nanocrystals on zwitterionic DOPC bilayers and negatively charged DMPG vesicles adsorbed on mica, on zw…
▽ More
The interaction between the bacterial S-protein SbpA on different types of lipid membranes has been studied using atomic force microscopy, transmission electron microscopy, and quartz crystal microbalance with dissipation. On one hand, It has been found that the bacterial forms two dimensional nanocrystals on zwitterionic DOPC bilayers and negatively charged DMPG vesicles adsorbed on mica, on zwitterionic DPPC and charged DPPC/DMPG (1:1) monolayers adsorbed on carbon grids. On the other hand, SbpA protein adsorption took place on zwitterionic DOPC bilayers and DOPC/DOPS (4:1) bilayers, previously adsorbed on silicon supports. SbpA adsorption also took place on DPPC/DOPS (1:1) monolayers adsorbed on carbon grids. Finally, neither SbpA adsorption, nor recrystallization was observed on zwitterionic DMPC vesicles (previously adsorbed on polyelectrolyte multilayers), and on DPPC vesicles supported on silicon.
△ Less
Submitted 10 April, 2009;
originally announced April 2009.
-
Effect of fatigue on the intra-cycle acceleration in front crawl swimming: A time-frequency analysis
Authors:
V. Tella,
J. L. Toca-Herrera,
J. E. Gallach,
J. Benavent,
L. M. Gonzalez,
R. Arellano
Abstract:
The present study analyzes the changes in acceleration produced by swimmers before and after fatiguing effort. The subjects (n=15) performed a 25-meter crawl series at maximum speed without fatigue, and a second series with fatigue. The data were registered with a synchronized system that consisted in a position transducer (1 kHz) and a video photogrametry (50Hz). The acceleration (ms-2) was obt…
▽ More
The present study analyzes the changes in acceleration produced by swimmers before and after fatiguing effort. The subjects (n=15) performed a 25-meter crawl series at maximum speed without fatigue, and a second series with fatigue. The data were registered with a synchronized system that consisted in a position transducer (1 kHz) and a video photogrametry (50Hz). The acceleration (ms-2) was obtained by the derivative analysis of the variation of the position with time. The amplitude in the time domain was calculated with the root mean square (RMS); while the peak power (PP), the peak power frequency (PPF) and the spectrum area (SA) was calculated in the frequency domain with Fourier analysis. On one hand, the results of the temporal domain show that the RMS change percentage between series was 67.5% (p<0.001). On the other hand, PP, PPF, and SA show significant changes (p<0.001). PP and SA were reduced by 63.1% and 59.5%, respectively. Our results show that the acceleration analysis of the swimmer with Fourier analysis permits a more precise understanding of which propulsive forces contribute to the swimmer performance before and after fatigue appears.
△ Less
Submitted 18 January, 2008;
originally announced January 2008.
-
Strength stimuli on the quadriceps femoris influences the physiological tremor of the index finger
Authors:
Miguel J. A. Lainez,
Luis-Millan Gonzalez,
Jose E. Gallach,
Gerard Moras,
Daniel Ranz,
Jose L. Toca-Herrera
Abstract:
The influence of fatiguing stimuli applied to the quadriceps femoris on the tremor of the index finger on sixteen healthy subjects has been investigated, by measuring the acceleration and the electromyography activity of the extensor digitorum at two different speeds. No significant changes in the basal condition could be measured at 0.52 rad/s. However, at 1.05 rad/s the tremor amplitude (12.23…
▽ More
The influence of fatiguing stimuli applied to the quadriceps femoris on the tremor of the index finger on sixteen healthy subjects has been investigated, by measuring the acceleration and the electromyography activity of the extensor digitorum at two different speeds. No significant changes in the basal condition could be measured at 0.52 rad/s. However, at 1.05 rad/s the tremor amplitude (12.23%, p<0.05) and the electromyography activity (20.19%, p<0.05) increased in the time domain. In the frequential domain, the peak associated to the acceleration increased in 26.30% (p<0.05), while the electromiography activity experienced an increase of 81.34% (p<0.05). The largest change in frequency took place in the range 7-17 Hz. The discussion of the results leads to the conclusion that the supraespinal mechanism is responsible for the measured effect.
△ Less
Submitted 17 January, 2008;
originally announced January 2008.