-
Topologically Distinct Berry Phases in a Single Triangular Möbius Microwave Resonator
Authors:
E. C. I. Paterson,
M. E. Tobar,
M. Goryachev,
J. Bourhill
Abstract:
We report the experimental observation of two distinct Berry phases ($+\frac{2π}{3}$ and $-\frac{2π}{3}$) generated on the surface of a Möbius cavity resonator at microwave frequencies supporting the TE$_{1,0,n}$ mode family. This resonator consists of a twisted, mirror-asymmetric prism with a cross-section of the triangular $D_3$ symmetry group, bent around on itself to form a ring. This geometri…
▽ More
We report the experimental observation of two distinct Berry phases ($+\frac{2π}{3}$ and $-\frac{2π}{3}$) generated on the surface of a Möbius cavity resonator at microwave frequencies supporting the TE$_{1,0,n}$ mode family. This resonator consists of a twisted, mirror-asymmetric prism with a cross-section of the triangular $D_3$ symmetry group, bent around on itself to form a ring. This geometric class supports resonant modes with non-zero electromagnetic helicity (i.e. nonzero $\vec{E}\cdot\vec{B}$ product) at microwave frequencies. There exist modes with three-fold rotational symmetry as well as those that exhibit no rotational symmetry. The latter result in an accumulated Berry phase whilst the former do not, which is determined from the measured frequency shift of the modes when compared to a mirror-symmetric resonator of otherwise equivalent geometry.
△ Less
Submitted 26 May, 2025;
originally announced June 2025.
-
Electromagnetic Helicity in Twisted Cavity Resonators
Authors:
E. C. I. Paterson,
J. Bourhill,
M. E. Tobar,
M. Goryachev
Abstract:
Through left- or right-handed twisting, we investigate the impact of mirror-asymmetry (chirality) of the conducting boundary conditions of an equilaterial triangular cross-section electromagnetic resonator. We observe the generation of eigenmodes with non-zero electromagnetic helicity as a result of the coupling of near degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes. This can be interpreted as an…
▽ More
Through left- or right-handed twisting, we investigate the impact of mirror-asymmetry (chirality) of the conducting boundary conditions of an equilaterial triangular cross-section electromagnetic resonator. We observe the generation of eigenmodes with non-zero electromagnetic helicity as a result of the coupling of near degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes. This can be interpreted as an emergence of magneto-electric coupling, which in turn produces a measurable shift in resonant mode frequency as a function of twist angle. We show that this coupling mechanism is equivalent to introducing a non-zero chirality material parameter $κ_\text{eff}$ or axion field $θ_{\text{eff}}$ to the medium. Our findings demonstrate the potential for real-time, macroscopic manipulation of electromagnetic helicity.
△ Less
Submitted 23 June, 2025; v1 submitted 3 April, 2025;
originally announced April 2025.
-
Ultraviolet Light-Induced Microwave Mode Tuning in a Rutile TiO$_2$ Whispering Gallery Resonator
Authors:
Catriona A. Thomson,
Michael E. Tobar,
Maxim Goryachev
Abstract:
We report the observation of transient nonlinear optical effects in a macroscopic whispering gallery mode resonator made of rutile TiO$_2$, demonstrating strong optical-microwave transduction under laser irradiation. By comparing the effects of ultraviolet (UV, 385 nm) and near-infrared (NIR, 700 nm) radiation, we find that the UV-induced effects are significantly amplified, consistent with the ma…
▽ More
We report the observation of transient nonlinear optical effects in a macroscopic whispering gallery mode resonator made of rutile TiO$_2$, demonstrating strong optical-microwave transduction under laser irradiation. By comparing the effects of ultraviolet (UV, 385 nm) and near-infrared (NIR, 700 nm) radiation, we find that the UV-induced effects are significantly amplified, consistent with the material's semiconductor bandgap energy. The interaction results in frequency shifts of microwave modes and changes in quality factor, suggesting a localized saturable refractive index tuning. This may be attributed to the saturation of a spin transition of a dopant ion within the crystal lattice. Remarkably, these effects are observed at low optical powers, down to nanowatt levels, indicating high sensitivity and efficient of light-matter interaction in this system. The phenomenon is centered around 15 GHz, yet electron spin resonance measurements reveal no zero-field splitting at this frequency, suggesting an alternative mechanism beyond conventional spin resonance. These findings highlight the potential of low-power optical control of microwave modes in high-Q resonators for applications in quantum technologies, sensing, and reconfigurable photonic-microwave systems.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
Upconversion of Phonon Modes into Microwave Photons in a Lithium Niobate Bulk Acoustic Wave Resonator Coupled to a Microwave Cavity
Authors:
S. Parashar,
W. M. Campbell,
J. Bourhill,
E. N. Ivanov,
M. Goryachev,
M. E. Tobar
Abstract:
The coupling between acoustic vibrations in a lithium niobate bulk acoustic wave resonator and microwave photons of a re-entrant microwave cavity was investigated at a temperature close to 4 K. Coupling was achieved by placing the acoustic resonator in the location of the re-entrant cavity electric field maxima, in a symmetric "split-post" configuration, with a large overlap between the microwave…
▽ More
The coupling between acoustic vibrations in a lithium niobate bulk acoustic wave resonator and microwave photons of a re-entrant microwave cavity was investigated at a temperature close to 4 K. Coupling was achieved by placing the acoustic resonator in the location of the re-entrant cavity electric field maxima, in a symmetric "split-post" configuration, with a large overlap between the microwave field and the acoustic mode, allowing acoustic modulations of the microwave frequency. We show that the acoustic modes in this setup retain large inherent quality factors of greater than $10^6$. A maximum optomechanical coupling rate was determined to be $g_0$ = 0.014 mHz, four orders of magnitude larger than previous results obtained using a quartz BAW at 4 K in a similar experimental setup, but using a single post-re-entrant cavity resonator.
△ Less
Submitted 7 November, 2024; v1 submitted 26 October, 2024;
originally announced October 2024.
-
Sharp electromagnetically induced absorption via balanced interferometric excitation in a microwave resonator
Authors:
Michael Hatzon,
Graeme Flower,
Maxim Goryachev,
Jeremy Bourhill,
Michael E. Tobar
Abstract:
A cylindrical TM$_{0,1,0}$ mode microwave cavity resonator was excited using a balanced interferometric configuration that allowed manipulation of the electric field and potential within the resonator by adjusting the phase and amplitude of the interferometer arms driving the resonator. With precise tuning of the phase and amplitude, 25 dB suppression of the electric field at the resonance frequen…
▽ More
A cylindrical TM$_{0,1,0}$ mode microwave cavity resonator was excited using a balanced interferometric configuration that allowed manipulation of the electric field and potential within the resonator by adjusting the phase and amplitude of the interferometer arms driving the resonator. With precise tuning of the phase and amplitude, 25 dB suppression of the electric field at the resonance frequency was achieved while simultaneously resonantly enhancing the time-varying electric-scalar potential. Under these conditions, the system demonstrated electromagnetically induced absorption in the cavity response due to the annulment of the electric field at the resonance frequency. This phenomena can be regarded as a form of extreme dispersion, and led to a sharp increase in the cavity phase versus frequency response by an order of magnitude when compared to the cavity Q-factor. This work presents an experimental setup that will allow the electric-scalar Aharonov-Bohm effect to be tested under conditions involving a time-varying electric-scalar potential, without the presence of an electric field or magnetic vector potential, an experiment that has not yet been realised.
△ Less
Submitted 5 February, 2025; v1 submitted 2 October, 2024;
originally announced October 2024.
-
Scalar Gravitational Aharonov-Bohm Effect: Generalization of the Gravitational Redshift
Authors:
Michael E Tobar,
Michael T Hatzon,
Graeme R Flower,
Maxim Goryachev
Abstract:
The Aharonov-Bohm effect is a quantum mechanical phenomenon that demonstrates how potentials can have observable effects even when the classical fields associated with those potentials are absent. Initially proposed for electromagnetic interactions, this effect has been experimentally confirmed and extensively studied over the years. More recently, the effect has been observed in the context of gr…
▽ More
The Aharonov-Bohm effect is a quantum mechanical phenomenon that demonstrates how potentials can have observable effects even when the classical fields associated with those potentials are absent. Initially proposed for electromagnetic interactions, this effect has been experimentally confirmed and extensively studied over the years. More recently, the effect has been observed in the context of gravitational interactions using atom interferometry. Additionally, recent predictions suggest that temporal variations in the phase of an electron wave function will induce modulation sidebands in the energy levels of an atomic clock, solely driven by a time-varying scalar gravitational potential [1]. In this study, we consider the atomic clock as a two-level system undergoing continuous Rabi oscillations between the electron's ground and excited state. We assume the photons driving the transition are precisely frequency-stabilized to match the transition, enabling accurate clock comparisons. Our analysis takes into account, that when an atom transitions from its ground state to an excited state, it absorbs energy, increasing its mass according to the mass-energy equivalence principle. Due to the mass difference between the two energy levels, we predict that an atomic clock in an eccentric orbit will exhibit a constant frequency shift relative to a ground clock corresponding to the orbit's average gravitational redshift, with additional modulation sidebands due to the time-varying gravitational potential.
△ Less
Submitted 26 August, 2024;
originally announced August 2024.
-
Near-quantum-limited axion dark matter search with the ORGAN experiment around 26 $μ$eV
Authors:
Aaron P. Quiskamp,
Graeme Flower,
Steven Samuels,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The latest result from the ORGAN experiment, an axion haloscope is presented. This iteration of the experiment operated at millikelvin temperatures using a flux-driven Josephson parametric amplifier for reduced noise, along with various other improvements over previous iterations. Covering the $25.45 - 26.27\,μ\text{eV}$ ($6.15-6.35$ GHz) mass (frequency) range, this near-quantum limited phase of…
▽ More
The latest result from the ORGAN experiment, an axion haloscope is presented. This iteration of the experiment operated at millikelvin temperatures using a flux-driven Josephson parametric amplifier for reduced noise, along with various other improvements over previous iterations. Covering the $25.45 - 26.27\,μ\text{eV}$ ($6.15-6.35$ GHz) mass (frequency) range, this near-quantum limited phase of ORGAN employs a conducting rod resonator and a 7-T solenoidal magnet to place the most sensitive exclusion limits on axion-photon coupling in the range to date, with $|g_{aγγ}| \gtrsim 2.8\times10^{-13}$ at a 95\% confidence level.
△ Less
Submitted 11 May, 2025; v1 submitted 26 July, 2024;
originally announced July 2024.
-
Low Temperature Properties of Low-Loss Macroscopic Lithium Niobate Bulk Acoustic Wave Resonators
Authors:
William M. Campbell,
Leonardo Mariana,
Sonali Parashar,
Michael E. Tobar,
Maxim Goryachev
Abstract:
We investigate gram scale macroscopic bulk acoustic wave (BAW) resonators manufactured from plates of piezoelectric lithium niobate. The intrinsic competing loss mechanisms were studied at cryogenic temperature through precision measurements of various BAW modes. Exceptional quality factors were measured for the longitudinal BAW modes in the 1-100 MHz range, with a maximum quality factor of 8.9 mi…
▽ More
We investigate gram scale macroscopic bulk acoustic wave (BAW) resonators manufactured from plates of piezoelectric lithium niobate. The intrinsic competing loss mechanisms were studied at cryogenic temperature through precision measurements of various BAW modes. Exceptional quality factors were measured for the longitudinal BAW modes in the 1-100 MHz range, with a maximum quality factor of 8.9 million, corresponding to a quality factor $\times$ frequency product of 3.8 $\times 10^{14}$ Hz. Through measurements of the acoustic response to a strong drive tone, anomalous self induced absorption and transparency effects are observed. We show that such observations can be explained by microscopic impurities and defect sites in the crystal bulk by the use of a non linear model of acoustic dissipation. The losses associated with these defects provide the ultimate limit of resonator performance, which could be improved in the future if more pure samples were available.
△ Less
Submitted 9 June, 2025; v1 submitted 24 July, 2024;
originally announced July 2024.
-
Detecting kHz gravitons from a neutron star merger with a multi-mode resonant mass detector
Authors:
Germain Tobar,
Igor Pikovski,
Michael Edmund Tobar
Abstract:
We propose a multi-mode bar consisting of mass elements of decreasing size for the implementation of a gravitational version of the photo-electric effect through the stimulated absorption of up to kHz gravitons from a binary neutron star merger and post-merger. We find that the multi-mode detector has normal modes that retain the coupling strength to the gravitational wave of the largest mass-elem…
▽ More
We propose a multi-mode bar consisting of mass elements of decreasing size for the implementation of a gravitational version of the photo-electric effect through the stimulated absorption of up to kHz gravitons from a binary neutron star merger and post-merger. We find that the multi-mode detector has normal modes that retain the coupling strength to the gravitational wave of the largest mass-element, while only having an effective mass comparable to the mass of the smallest element. This allows the normal modes to have graviton absorption rates due to the tonne-scale largest mass, while the single graviton absorption process in the normal mode could be resolved through energy measurements of a mass-element in-principle smaller than pico-gram scale. We argue the feasibility of directly counting gravito-phonons in the bar through energy measurements of the end mass. This improves the transduction of the single-graviton signal, enhancing the feasibility of detecting single gravitons.
△ Less
Submitted 10 March, 2025; v1 submitted 28 May, 2024;
originally announced June 2024.
-
Microwave Cavity Mode Optimisation by Background Anti-Resonance Tuning
Authors:
Michael T. Hatzon,
Eugene N. Ivanov,
Jeremy F. Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high…
▽ More
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high contrast and symmetry can be achieved by changing the dimensions of the surrounding cavity shield to tune the background low-Q structures into anti-resonance. This works because the high-Q resonances are primarily defined by the sapphire while the background modes are defined by the cavity shield. Alternatively, it was shown that a similar result can be achieved by exciting the high-Q resonator with a balanced microwave dipole probe in a Mach Zehnder interferometric configuration. The probe was constructed from two separate coaxial electric field probes symmetrically inserted into a cylindrical cavity resonator, from opposite sides with a small gap between them, so they can behave like an active wire dipole antenna. The power into the two separate probes may be matched with an external variable attenuator in one of the arms of the interferometer. Conversely, the phase between the two electric field probes may be changed with an external variable phase shifter, which changes the nature of the field components the probe couples to. The probe couples to the high-Q resonant modes as well as low-Q background modes, which can be made resonant or anti-resonant for the high-Q modes by changing this external phase. When the background modes are in anti-resonance the line shape of the high-Q mode can be made symmetric and with higher contrast. This technique was applied to both whispering gallery sapphire modes, as well as hollow cavity resonators, without changing the dimensions of the cavity.
△ Less
Submitted 13 July, 2024; v1 submitted 25 April, 2024;
originally announced May 2024.
-
Noise Suppression with Cryogenic Resonators
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each sapphire crystal was shaped like a spindle with the rotational and crystal axes aligned within a degree. Noise suppression factors in excess of 50 dB were measured a…
▽ More
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each sapphire crystal was shaped like a spindle with the rotational and crystal axes aligned within a degree. Noise suppression factors in excess of 50 dB were measured at 10 kHz offset from the carrier. This was achieved by rotating the sapphire spindle and moving the coupling probes relative to its surface. Microwave signals with reduced fast technical fluctuations allow the high-precision tests of fundamental physics, as well as the development of better radars.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Frequency Stable Microwave Sapphire Oscillators
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We show that state-of-the-art phase noise and high frequency stability could be simultaneously achieved in a microwave oscillator based on the sapphire-loaded cavity resonator. The 9 GHz sapphire oscillator was constructed with the SSB phase noise close to -170 dBc/Hz at an offset frequency of 10 kHz and fractional frequency instability less than 2 10$^{-13}$ for integration times from 5 to 50 s.…
▽ More
We show that state-of-the-art phase noise and high frequency stability could be simultaneously achieved in a microwave oscillator based on the sapphire-loaded cavity resonator. The 9 GHz sapphire oscillator was constructed with the SSB phase noise close to -170 dBc/Hz at an offset frequency of 10 kHz and fractional frequency instability less than 2 10$^{-13}$ for integration times from 5 to 50 s. In this work, we focus on the technique for phase-referencing the microwave sapphire oscillator to a stable radio-frequency source. We also discuss the suppression of the fast phase fluctuations of the microwave signal due to its transmission through the high-Q resonator.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
Gravitational Wave Detection and Low-Noise Sapphire Oscillators
Authors:
Michael Edmund Tobar
Abstract:
This thesis describes the development of an ultra-low noise sapphire resonator oscillator that is tunable over X-band. While undertaking this task the author has explained some interesting and very useful phenomena in regards to the design and understanding of multi-mode resonant cavities and oscillators. The oscillator was constructed to operate as the pump oscillator in the superconducting param…
▽ More
This thesis describes the development of an ultra-low noise sapphire resonator oscillator that is tunable over X-band. While undertaking this task the author has explained some interesting and very useful phenomena in regards to the design and understanding of multi-mode resonant cavities and oscillators. The oscillator was constructed to operate as the pump oscillator in the superconducting parametric transducer system, attached to a 1.5-tonne niobium resonant bar gravitational wave detector. The effects of incorporating the pump oscillator with the parametric transducer and resonant bar system are analyzed to enable prediction of the detector sensitivity. The detector was the first massive precision optomechanical system ever built. With the resurgence in interest in resonant detectors, this thesis has important work on multi-mode acoustic systems, coupled to a highly sensitive parametric transducer relevant for many fields of research today.
△ Less
Submitted 27 November, 2023;
originally announced November 2023.
-
Exclusion of ALP Cogenesis Dark Matter in a Mass Window Above 100 $μ$eV
Authors:
Aaron Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
We report the results of Phase 1b of The ORGAN Experiment, a microwave cavity haloscope searching for dark matter axions in the $107.42-111.93~μ$eV mass range. The search excludes axions with two-photon coupling $g_{aγγ}\geq 4\times 10^{-12}\, \textrm{GeV}^{-1}$ with $95\%$ confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axion-like particl…
▽ More
We report the results of Phase 1b of The ORGAN Experiment, a microwave cavity haloscope searching for dark matter axions in the $107.42-111.93~μ$eV mass range. The search excludes axions with two-photon coupling $g_{aγγ}\geq 4\times 10^{-12}\, \textrm{GeV}^{-1}$ with $95\%$ confidence interval, setting the best upper bound to date and with the required sensitivity to exclude the axion-like particle cogenesis model for dark matter in this range. This result was achieved using a tunable rectangular cavity, which mitigated several practical issues that become apparent when conducting high mass axion searches, and was the first such axion search to be conducted with such a cavity. It also represents the most sensitive axion haloscope experiment to date in the $\sim100~μ$eV mass region.
△ Less
Submitted 2 October, 2023;
originally announced October 2023.
-
Tunable Rectangular Resonant Cavities for Axion Haloscopes
Authors:
Ben T. McAllister,
Aaron P. Quiskamp,
Michael E. Tobar
Abstract:
Axions are a compelling dark matter candidate, and one of the primary techniques employed to search for them is the axion haloscope, in which a resonant cavity is deployed inside a strong magnetic field so that some of the surrounding axions may convert into photons via the inverse Primakoff effect and become trapped inside the resonator. Resonant cavity design is critical to the sensitivity of a…
▽ More
Axions are a compelling dark matter candidate, and one of the primary techniques employed to search for them is the axion haloscope, in which a resonant cavity is deployed inside a strong magnetic field so that some of the surrounding axions may convert into photons via the inverse Primakoff effect and become trapped inside the resonator. Resonant cavity design is critical to the sensitivity of a haloscope, and several geometries have been utilised and proposed. Here we consider a relatively simple concept - a rectangular resonant cavity with a tunable wall - and compare it to the standard tuning rod-type resonators employed in the field. We find that the rectangular cavities support similar modes to cylindrical tuning rod cavities, and have some advantages in terms of axion sensitivity and practicality, particularly when moving to higher frequencies which are of great and growing interest in the international axion dark matter community.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Searching for GUT-scale QCD Axions and Monopoles with a High Voltage Capacitor
Authors:
Michael E. Tobar,
Anton V. Sokolov,
Andreas Ringwald,
Maxim Goryachev
Abstract:
The QCD axion has been postulated to exist because it solves the strong CP problem. Furthermore, if it exists axions should be created in the early Universe and could account for all the observed dark matter. In particular, axion masses of order $10^{-10}$ to $10^{-7}$ eV correspond to axions in the vicinity of the GUT-scale. In this mass range many experiments have been proposed to search for the…
▽ More
The QCD axion has been postulated to exist because it solves the strong CP problem. Furthermore, if it exists axions should be created in the early Universe and could account for all the observed dark matter. In particular, axion masses of order $10^{-10}$ to $10^{-7}$ eV correspond to axions in the vicinity of the GUT-scale. In this mass range many experiments have been proposed to search for the axion through the standard QED coupling parameter $g_{aγγ}$. Recently axion electrodynamics has been expanded to include two more coupling parameters, $g_{aEM}$ and $g_{aMM}$, which could arise if heavy magnetic monopoles exist. In this work we show that both $g_{aMM}$ and $g_{aEM}$ may be searched for using a high voltage capacitor. Since the experiment is not sensitive to $g_{aγγ}$, it gives a new way to search for effects of heavy monopoles if the GUT-scale axion is shown to exist, or to simultaneously search for both the axion and the monopole at the same time.
△ Less
Submitted 2 August, 2023; v1 submitted 23 June, 2023;
originally announced June 2023.
-
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
Authors:
S. Chakrabarty,
J. R. Gleason,
Y. Han,
A. T. Hipp,
M. Solano,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
M. Goryachev,
E. Hartman,
B. T. McAllister,
A. Quiskamp,
C. Thomson,
M. E. Tobar,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
T. Braine,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg
, et al. (22 additional authors not shown)
Abstract:
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and…
▽ More
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
△ Less
Submitted 28 March, 2023; v1 submitted 7 March, 2023;
originally announced March 2023.
-
Sensitivity of Resonant Axion Haloscopes to Quantum Electromagnetodynamics
Authors:
Michael E. Tobar,
Catriona A. Thomson,
Benjamin T. McAllister,
Maxim Goryachev,
Anton Sokolov,
Andreas Ringwald
Abstract:
Recently interactions between putative axions and magnetic monopoles have been revisited by two of us [arXiv:2205.02605 [hep-ph]]. It has been shown that significant modifications to conventional axion electrodynamics arise due to these interactions, so that the axion-photon coupling parameter space is expanded from one parameter $g_{aγγ}$ to three $(g_{aγγ},g_{aAB},g_{aBB})$. We implement Poyntin…
▽ More
Recently interactions between putative axions and magnetic monopoles have been revisited by two of us [arXiv:2205.02605 [hep-ph]]. It has been shown that significant modifications to conventional axion electrodynamics arise due to these interactions, so that the axion-photon coupling parameter space is expanded from one parameter $g_{aγγ}$ to three $(g_{aγγ},g_{aAB},g_{aBB})$. We implement Poynting theorem to determine how to exhibit sensitivity to $g_{aAB}$ and $g_{aBB}$ using resonant haloscopes, allowing new techniques to search for axions and a possible indirect way to determine if magnetically charged matter exists.
△ Less
Submitted 24 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Searching for Ultra-Light Axions with Twisted Cavity Resonators of Anyon Rotational Symmetry with Bulk Modes of Non-Zero Helicity
Authors:
J. F. Bourhill,
E. C. I. Paterson,
M. Goryachev,
M. E. Tobar
Abstract:
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow…
▽ More
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow structures using equilateral triangular cross-sections, which leads to the realization of a cavity with anyon rotational symmetry. Unlike all previous cavity resonators, the anyon resonator permits the existence of bulk resonant modes that exhibit non-zero electromagnetic helicity in vacuo, with a non-zero overlap of the electric and magnetic mode eigenvectors, $\int \mathbf{E}_p\cdot\mathbf{B}_p~dτ$, integrated over the cavity volume. In the upconversion limit, we show that these non-zero helical modes couple naturally to ultra-light dark matter axions within the bandwidth of the resonator by adding amplitude-modulated sidebands through the axion-photon chiral anomaly. Thus, we show a sensitive ultra-light dark matter experiment may be realized by implementing such a resonator in an ultra-stable oscillator configuration and searching for signals in the Fourier spectrum of amplitude fluctuations. This removes the typical requirement for an external magnetic field and therefore permits the use of superconducting materials to reduce surface losses and enhance sensitivity to axions.
△ Less
Submitted 9 August, 2023; v1 submitted 1 August, 2022;
originally announced August 2022.
-
Electro-Mechanical Tuning of High-Q Bulk Acoustic Phonon Modes at Cryogenic Temperatures
Authors:
William M. Campbell,
Serge Galliou,
Michael E. Tobar,
Maxim Goryachev
Abstract:
We investigate the electromechanical properties of quartz bulk acoustic wave resonators at extreme cryogenic temperatures. By applying a DC bias voltage, we demonstrate broad frequency tuning of high-Q phonon modes in a quartz bulk acoustic wave cavity at cryogenic temperatures of 4 K and 20 mK. More than 100 line-widths of tuning of the resonance peak without any degradation in loaded quality fac…
▽ More
We investigate the electromechanical properties of quartz bulk acoustic wave resonators at extreme cryogenic temperatures. By applying a DC bias voltage, we demonstrate broad frequency tuning of high-Q phonon modes in a quartz bulk acoustic wave cavity at cryogenic temperatures of 4 K and 20 mK. More than 100 line-widths of tuning of the resonance peak without any degradation in loaded quality factor, which are as high as $1.73\times 10^9$, is seen for high order overtone modes. For all modes and temperatures the observed coefficient of frequency tuning is $\approx$ 3.5 mHz/V per overtone number $n$ corresponding to a maximum of 255.5 mHz/V for the $n = 73$ overtone mode. No degradation in the quality factor is observed for any value of applied biasing field.
△ Less
Submitted 19 October, 2022; v1 submitted 3 July, 2022;
originally announced July 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situat…
▽ More
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Can Traditional Terrestrial Applications of Gravity Gradiometry Rely Upon Quantum Technologies ? A Side View
Authors:
Alexey V. Veryaskin,
Michael E. Tobar
Abstract:
The era of practical terrestrial applications of gravity gradiometry begun in 1890 when Baron Lorand von Eötvös, a Hungarian nobleman and a talented physicist and engineer, invented his famous torsion balance - the first practical gravity gradients measuring device. It was credited for the major oil discoveries later in Texas (USA). A 100 years later Kasevich and Chu pioneered the use of quantum p…
▽ More
The era of practical terrestrial applications of gravity gradiometry begun in 1890 when Baron Lorand von Eötvös, a Hungarian nobleman and a talented physicist and engineer, invented his famous torsion balance - the first practical gravity gradients measuring device. It was credited for the major oil discoveries later in Texas (USA). A 100 years later Kasevich and Chu pioneered the use of quantum physics for gravity gradient measurements. Since then cold-atom gravity gradiometers, or matter-wave gravity gradiometers, had been under development at almost every physics department of top-rated universities around the globe. After another 30 years since the Kasevich and Chu publication in 1992, which had led to the first ever quantum gravity gradiometer, the corresponding research and development ceased from being profoundly active a few years back. This article is an attempt to understand and explain what may have happened to the Quantum Invasion into the area of applied physics and precision engineering that traditionally has been occupied by non-quantum technologies developed for about a 130 years of the history of gravity gradiometry.
△ Less
Submitted 14 January, 2022; v1 submitted 12 August, 2021;
originally announced August 2021.
-
Generation of Bimodal Solitons in a Sapphire Whispering Gallery Mode Maser at Millikelvin Temperatures
Authors:
Catriona A. Thomson,
Michael E. Tobar,
Maxim Goryachev
Abstract:
We present experimental observations of bimodal solitons in a solid state three-level maser cooled to millikelvin temperatures. The maser is built on a highly dilute $\textrm{Fe}^{3+}$ spin ensemble hosted by a high purity $\textrm{Al}_{2}\textrm{O}_{3}$ crystal constituting a high quality factor whispering-gallery-mode resonator. The maser is pumped through one of these modes, near 31 GHz, genera…
▽ More
We present experimental observations of bimodal solitons in a solid state three-level maser cooled to millikelvin temperatures. The maser is built on a highly dilute $\textrm{Fe}^{3+}$ spin ensemble hosted by a high purity $\textrm{Al}_{2}\textrm{O}_{3}$ crystal constituting a high quality factor whispering-gallery-mode resonator. The maser is pumped through one of these modes, near 31 GHz, generating two signals near 12.04 GHz from two distinct modes, 8 MHz apart. The system demonstrates three regimes, namely, a continuous wave regime, a dense soliton regime and a sparse soliton regime. These results open new avenues for studying nonlinear wave phenomena using microwave systems as well as new applications of solitons in this part of the electromagnetic spectrum.
△ Less
Submitted 21 February, 2022; v1 submitted 24 May, 2021;
originally announced May 2021.
-
Rare Events Detected with a Bulk Acoustic Wave High Frequency Gravitational Wave Antenna
Authors:
Maxim Goryachev,
William M. Campbell,
Ik Siong Heng,
Serge Galliou,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5…
▽ More
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5.506 MHz was monitored, while in Run 1 the second mode was chosen to be the 5th OT of the slow shear mode (5C) operating at 8.392 MHz. However, in Run 2 the second mode was selected to be closer in frequency to the first mode, and chosen to be the 3rd overtone of the slow shear mode (3C) operating at 4.993 MHz. Two strong events were observed as transients responding to energy deposition within acoustic modes of the cavity. The first event occurred during Run 1 on the 12/05/2019 (UTC), and was observed in the 5.506 MHz mode, while the second mode at 8.392 MHz observed no event. During Run 2, a second event occurred on the 27/11/2019(UTC) and was observed by both modes. Timing of the events were checked against available environmental observations as well as data from other detectors. Various possibilities explaining the origins of the events are discussed.
△ Less
Submitted 22 July, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Active Electric Dipole Energy Sources: Transduction via Electric Scalar and Vector Potentials
Authors:
Michael E. Tobar,
Raymond Y. Chiao,
Maxim Goryachev
Abstract:
An active electrical network contains a voltage or current source that creates electromagnetic energy through a method of transduction that enables the separation of opposite polarity charges from an external source. The end result is the creation of an active dipole with a permanent polarisation and a non-zero electric vector curl. The external energy input impresses a force per unit charge withi…
▽ More
An active electrical network contains a voltage or current source that creates electromagnetic energy through a method of transduction that enables the separation of opposite polarity charges from an external source. The end result is the creation of an active dipole with a permanent polarisation and a non-zero electric vector curl. The external energy input impresses a force per unit charge within the voltage source, to form an active physical dipole in the static case, or an active Hertzian dipole in the time dependent case. This system is the dual of an electromagnet or permanent magnet excited by a circulating electrical current or fictitious bound current respectively, which supplies a magnetomotive force described by a magnetic vector potential with a magnetic geometric phase proportional to the enclosed magnetic flux. In contrast, the active electric dipole may be described macroscopically by a circulating fictitious magnetic current boundary source described by an electric vector potential with an electric geometric phase proportional to the enclosed electric flux density. This macroscopic description of an active dipole is an average description of some underlying microscopic description exhibiting emergent nonconservative behaviour not found in classical conservative laws of electrodynamics. We show that the electromotive force produced by an active dipole must have both electric scalar and vector potential components to account for the magnitude of the voltage it produces. Following this we analyse an active cylindrical dipole in terms of scalar and vector potential and confirm that the electromotive force produced, and hence potential difference across the terminals is a combination of vector and scalar potential difference depending on aspect ratio of the dipole.
△ Less
Submitted 14 September, 2022; v1 submitted 28 December, 2020;
originally announced January 2021.
-
Searching for Scalar Dark Matter via Coupling to Fundamental Constants with Photonic, Atomic and Mechanical Oscillators
Authors:
William M. Campbell,
Ben T. McAllister,
Maxim Goryachev,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
We present a way to search for light scalar dark matter (DM), seeking to exploit putative coupling between dark matter scalar fields and fundamental constants, by searching for frequency modulations in direct comparisons between frequency stable oscillators. Specifically we compare a Cryogenic Sapphire Oscillator (CSO), Hydrogen Maser (HM) atomic oscillator and a bulk acoustic wave quartz oscillat…
▽ More
We present a way to search for light scalar dark matter (DM), seeking to exploit putative coupling between dark matter scalar fields and fundamental constants, by searching for frequency modulations in direct comparisons between frequency stable oscillators. Specifically we compare a Cryogenic Sapphire Oscillator (CSO), Hydrogen Maser (HM) atomic oscillator and a bulk acoustic wave quartz oscillator (OCXO). This work includes the first calculation of the dependence of acoustic oscillators on variations of the fundamental constants, and demonstration that they can be a sensitive tool for scalar DM experiments. Results are presented based on 16 days of data in comparisons between the HM and OCXO, and 2 days of comparison between the OCXO and CSO. No evidence of oscillating fundamental constants consistent with a coupling to scalar dark matter is found, and instead limits on the strength of these couplings as a function of the dark matter mass are determined. We constrain the dimensionless coupling constant $d_e$ and combination $|d_{m_e}-d_g|$ across the mass band $4.4\times10^{-19}\lesssim m_\varphi \lesssim 6.8\times10^{-14}\:\text{eV} c^{-2}$, with most sensitive limits $d_e\gtrsim1.59\times10^{-1}$, $|d_{m_e}-dg|\gtrsim6.97\times10^{-1}$. Notably, these limits do not rely on Maximum Reach Analysis (MRA), instead employing the more general coefficient separation technique. This experiment paves the way for future, highly sensitive experiments based on state-of-the-art acoustic oscillators, and we show that these limits can be competitive with the best current MRA-based exclusion limits.
△ Less
Submitted 15 April, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Generation of Coherent Phonons via a Cavity Enhanced Photonic Lambda Scheme
Authors:
Jeremy Bourhill,
Natalia do Carmo Carvalho,
Maxim Goryachev,
Serge Galliou,
Michael E. Tobar
Abstract:
We demonstrate the generation of coherent phonons in a quartz Bulk Acoustic Wave (BAW) resonator through the photoelastic properties of the crystal, via the coupling to a microwave cavity enhanced by a photonic lambda scheme. This is achieved by imbedding a single crystal BAW resonator between the post and the adjacent wall of a microwave reentrant cavity resonator. This 3D photonic lumped LC reso…
▽ More
We demonstrate the generation of coherent phonons in a quartz Bulk Acoustic Wave (BAW) resonator through the photoelastic properties of the crystal, via the coupling to a microwave cavity enhanced by a photonic lambda scheme. This is achieved by imbedding a single crystal BAW resonator between the post and the adjacent wall of a microwave reentrant cavity resonator. This 3D photonic lumped LC resonator at the same time acts as the electrodes of a BAW phonon resonator, and allows the direct readout of coherent phonons via the linear piezoelectric response of the quartz. A microwave pump, $ω_p$ is tuned to the cavity resonance $ω_0$, while a probe frequency, $ω_{probe}$, is detuned and varied around the red and blue detuned values with respect to the BAW phonon frequency, $Ω_m$. The pump and probe power dependence of the generated phonons unequivocally determines the process to be electrostrictive, with the phonons produced at the difference frequency between pump and probe, with no back action effects involved. Thus, the phonons are created without threshold and can be considered analogous to a Coherent Population Trapped (CPT) maser scheme.
△ Less
Submitted 8 October, 2020; v1 submitted 30 July, 2020;
originally announced August 2020.
-
Precision Multi-Mode Dielectric Characterization of a Crystalline Perovskite Enables Determination of the Temperature-Dependent Phase Transitions
Authors:
Zijun C. Zhao,
Maxim Goryachev,
Jerzy Krupka,
Michael E. Tobar
Abstract:
Simple perovskite crystals undergo structural phase transitions on cooling to low temperatures, which significantly change the material properties of the crystal. In this work we rigorously characterize the temperature evolution of permittivity of a perovskite crystal as it undergoes phase transitions. In particular, we have undertaken precision measurements of a single crystal of Strontium Titana…
▽ More
Simple perovskite crystals undergo structural phase transitions on cooling to low temperatures, which significantly change the material properties of the crystal. In this work we rigorously characterize the temperature evolution of permittivity of a perovskite crystal as it undergoes phase transitions. In particular, we have undertaken precision measurements of a single crystal of Strontium Titanate from 294.6 K to 5.6 K, by measuring the frequency of multiple microwave transverse electric and magnetic resonant modes simultaneously. The multi-mode microwave measurement technique of resonant frequency used in this work allows high precision determination of any induced anisotropy of the permittivity as the crystal undergoes structural phase transitions. Compared with previous results we unequivocally show that the permittivity has an isotropic value of $316.3\pm2.2$ at room temperature, consistent with its well-known cubic structure, and determine the onset of dielectric anisotropy as the crystal is cooled to lower temperatures. We show that the crystal exhibits uniaxial anisotropy in the permittivity below 105 K when the structure becomes tetragonal, and exhibits biaxial anisotropy in the permittivity below 51 K when the structure becomes orthorhombic.
△ Less
Submitted 25 August, 2021; v1 submitted 17 August, 2020;
originally announced August 2020.
-
Gravitational wave detectors with broadband high frequency sensitivity
Authors:
Michael A. Page,
Maxim Goryachev,
Haixing Miao,
Yanbei Chen,
Yiqiu Ma,
David Mason,
Massimiliano Rossi,
Carl D. Blair,
Li Ju,
David G. Blair,
Albert Schliesser,
Michael E. Tobar,
Chunnong Zhao
Abstract:
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Res…
▽ More
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Resonant enhancement by signal recycling normally improves the signal to noise ratio at the expense of bandwidth. The concept of optomechanical white light signal recycling (WLSR) has been proposed, but all schemes to date have been reliant on the development of suitable ultra-low mechanical loss components. Here for the first time we show demonstrated optomechanical resonator structures that meet the loss requirements for a WLSR interferometer with strain sensitivity below 10$^{-24}$ Hz$^{-1/2}$ at a few kHz. Experimental data for two resonators are combined with analytic models of 4km interferometers similar to LIGO, to demonstrate sensitivity enhancement across a much broader band of neutron star coalescence frequencies than dual-recycled Fabry-Perot Michelson detectors of the same length. One candidate resonator is a silicon nitride membrane acoustically isolated from the environment by a phononic crystal. The other is a single-crystal quartz lens that supports bulk acoustic longitudinal waves. Optical power requirements could prefer the membrane resonator, although the bulk acoustic wave resonator gives somewhat better thermal noise performance. Both could be implemented as add-on components to existing detectors.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Dielectric-Boosted Sensitivity to Cylindrical Azimuthally Varying Transverse-Magnetic Resonant Modes in an Axion Haloscope
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Gray Rybka,
Michael E. Tobar
Abstract:
Axions are a popular dark matter candidate which are often searched for in experiments known as ``haloscopes" which exploit a putative axion-photon coupling. These experiments typically rely on Transverse Magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant cavity design for application in haloscope searches, of par…
▽ More
Axions are a popular dark matter candidate which are often searched for in experiments known as ``haloscopes" which exploit a putative axion-photon coupling. These experiments typically rely on Transverse Magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant cavity design for application in haloscope searches, of particular use in the push to higher mass axion searches (above $\sim$60$\,μ$eV). In particular, we take advantage of azimuthally varying TM$_{m10}$ modes which, whilst typically insensitive to axions due to field non-uniformity, can be made axion-sensitive (and frequency tunable) through strategic placement of dielectric wedges, becoming a type of resonator known as a Dielectric Boosted Axion Sensitivity (DBAS) resonator. Results from finite-element modelling are presented, and compared with a simple proof-of-concept experiment. The results show a significant increase in axion sensitivity for these DBAS resonators over their empty cavity counterparts, and high potential for application in high mass axion searches when benchmarked against simpler, more traditional designs relying on fundamental TM modes.
△ Less
Submitted 8 November, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Probing the acoustic losses of graphene with a low-loss quartz bulk-acoustic-wave resonator at cryogenic temperatures
Authors:
Serge Galliou,
Jérémy Bon,
Philippe Abbé,
Rémy Vicarini,
Michael E. Tobar,
Maxim Goryachev
Abstract:
We observe mechanical effects of an exfoliated graphene monolayer deposited on a quartz crystal substrate designed to operate as an extremely low-loss bulk-acoustic-wave cavity at liquid-helium temperature.This is achieved by sensing overtones of the three thickness eigen-modes of the so-called SC-cut, since all three modes, two shear mode and one extensional mode, can be electrically probed with…
▽ More
We observe mechanical effects of an exfoliated graphene monolayer deposited on a quartz crystal substrate designed to operate as an extremely low-loss bulk-acoustic-wave cavity at liquid-helium temperature.This is achieved by sensing overtones of the three thickness eigen-modes of the so-called SC-cut, since all three modes, two shear mode and one extensional mode, can be electrically probed with such a crystal cut. From quality-factor measurements, the mechanical losses of the adhesive graphene monolayer are assessed to be about 8 x 10-4 at 4 K in the best case. They are therefore significantly greater than those already reported for suspended membranes but also for adherent layers on SiO2/Si substrates operating in torsional modes. In fact, results reveal that surface scattering occurs due to a roughness degradation of a factor 7. In addition, the mechanical losses presented here are also placed in the context of a device submitted to thermomechanical stresses, but which are not the only ones existing. Some of them could be intrinsic ones related to the deposition process of the graphene layer. Based on a force-frequency theory applied to the three thickness modes which react differently to stresses, it is demonstrated that this stress effect actually entangled with that of mass loading reconciles the experimental results.
△ Less
Submitted 17 November, 2022; v1 submitted 11 May, 2020;
originally announced May 2020.
-
Characterisation of Cryogenic Material Properties of 3D-Printed Superconducting Niobium using a 3D Lumped Element Microwave Cavity
Authors:
Ben T. McAllister,
Jeremy Bourhill,
Wing Him J. Ma,
Tim Sercombe,
Maxim Goryachev,
Michael E. Tobar
Abstract:
We present an experimental characterisation of the electrical properties of 3D-printed Niobium. The study was performed by inserting a 3D-printed Nb post inside an Aluminium cylindrical cavity, forming a 3D lumped element re-entrant microwave cavity resonator. The resonator was cooled to temperatures below the critical temperature of Niobium (9.25K) and then Aluminium (1.2K), while measuring the q…
▽ More
We present an experimental characterisation of the electrical properties of 3D-printed Niobium. The study was performed by inserting a 3D-printed Nb post inside an Aluminium cylindrical cavity, forming a 3D lumped element re-entrant microwave cavity resonator. The resonator was cooled to temperatures below the critical temperature of Niobium (9.25K) and then Aluminium (1.2K), while measuring the quality factors of the electromagnetic resonances. This was then compared with finite element analysis of the cavity and a measurement of the same cavity with an Aluminium post of similar dimensions and frequency, to extract the surface resistance of the Niobium post. The 3D-printed Niobium exhibited a transition to the superconducting state at a similar temperature to the regular Niobium, as well as a surface resistance of $3.1\times10^{-4}$ $Ω$. This value was comparable to many samples of traditionally machined Niobium previously studied without specialised surface treatment. Furthermore, this study demonstrates a simple new method for characterizing the material properties of a relatively small and geometrically simple sample of superconductor, which could be easily applied to other materials, particularly 3D-printed materials. Further research and development in additive manufacturing may see the application of 3D-printed Niobium in not only superconducting cavity designs, but in the innovative technology of the future.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.
-
Broadband Electrical Action Sensing Techniques with conducting wires for low-mass dark matter axion detection
Authors:
Michael Edmund Tobar,
Ben T. McAllister,
Maxim Goryachev
Abstract:
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-m…
▽ More
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-mass axions using the quasi-static technique. First, we calculate the current induced in an electric dipole antenna (straight conducting wire) when the DC B-field is spatially constant and show that it has a sensitivity proportional to the axion mass. Following this we extend the topology by making use of the full extent of the spatially varying DC B-field. This extension is achieved by transforming the 1D conducting wire to a 2D winding, to fully link the effective magnetic current boundary source and thus couple to the full axion induced electrical action. In this case the conductor becomes a coil winding where the voltage induced across the winding increases proportionally to the number of windings. We investigate two different topologies: The 1st uses a single winding, and couples to the effective short circuit current generated in the winding, which is read out using a sensitive low impedance SQUID amplifier: The 2nd uses multiple windings, with every turn effectively increasing the the voltage output proportional to the winding number. The read out of this configuration is optimised by implementing a cryogenic low-noise high input impedance voltage amplifier. The end result is a new Broadband Electrical Action Sensing Techniques with orders of magnitude improved sensitivity, which is linearly proportional to the axion photon coupling and capable of detecting QCD dark matter axions.
△ Less
Submitted 10 June, 2020; v1 submitted 15 April, 2020;
originally announced April 2020.
-
Casimir spring and dilution in macroscopic cavity optomechanics
Authors:
Jacob M. Pate,
Maxim Goryachev,
Raymond Y. Chiao,
Jay E. Sharping,
Michael Edmund Tobar
Abstract:
The Casimir force was predicted in 1948 as a force arising between macroscopic bodies from the zero-point energy. At finite temperatures it has been shown that a thermal Casimir force exists due to thermal rather than zero-point energy and there are a growing number of experiments that characterise the effect at a range of temperatures and distances. Additionally, in the rapidly evolving field of…
▽ More
The Casimir force was predicted in 1948 as a force arising between macroscopic bodies from the zero-point energy. At finite temperatures it has been shown that a thermal Casimir force exists due to thermal rather than zero-point energy and there are a growing number of experiments that characterise the effect at a range of temperatures and distances. Additionally, in the rapidly evolving field of cavity optomechanics there is an endeavor to manipulate phonons and enhance coherence. We demonstrate a new way to achieve this through the first observation of Casimir spring and dilution in macroscopic optomechanics, by coupling a metallic SiN membrane to a photonic re-entrant cavity. The attraction of the spatially-localised Casimir spring mimics a non-contacting boundary condition giving rise to increased strain and acoustic coherence through dissipation dilution. This work invents a new way to manipulate phonons via thermal photons leading to ``in situ'' reconfigurable mechanical states, to reduce loss mechanisms and to create new types of acoustic non-linearity -- all at room temperature.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Generation of Spectrally Pure Microwave Signals
Authors:
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
Based on the principles of microwave circuit interferometry we have constructed a Reduced Noise Amplifier (RNA) with power spectral density of phase, as well as amplitude, fluctuations close to -170 dBc/Hz at 1 kHz offset. The RNA has been incorporated with a cryogenic sapphire resonator as a loop oscillator whose noise performance is governed by the Leeson's model. Following this model and using…
▽ More
Based on the principles of microwave circuit interferometry we have constructed a Reduced Noise Amplifier (RNA) with power spectral density of phase, as well as amplitude, fluctuations close to -170 dBc/Hz at 1 kHz offset. The RNA has been incorporated with a cryogenic sapphire resonator as a loop oscillator whose noise performance is governed by the Leeson's model. Following this model and using the results of in-situ measurements of gain and phase fluctuations of the RNA we inferred noise properties of the oscillator. In particular, for a signal transmitted through the resonator we found that power spectral density of its phase/amplitude fluctuations must be close to -185 dBc/Hz at offsets above 300 Hz. We discuss a few approaches that will allow direct measurements of such low levels of noise.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
Generation of Ultra-Low Power Phononic Combs
Authors:
Maxim Goryachev,
Serge Galliou,
Michael E. Tobar
Abstract:
We demonstrate excitation of phononic frequency combs in a Bulk Acoustic Wave system at a temperature of $20$mK using a single tone low power signal source. The observed ultra low power threshold is due to a combination of very high quality factor of $4.2\times 10^8$ and relatively strong nonlinear effects. The observed repetition rate of the comb varies from 0.7 to 2Hz and spans over tens of Hert…
▽ More
We demonstrate excitation of phononic frequency combs in a Bulk Acoustic Wave system at a temperature of $20$mK using a single tone low power signal source. The observed ultra low power threshold is due to a combination of very high quality factor of $4.2\times 10^8$ and relatively strong nonlinear effects. The observed repetition rate of the comb varies from 0.7 to 2Hz and spans over tens of Hertz. The demonstrated system is fully excited via piezoelectricity and does not require mode spectra engineering and external optical or microwave signals. It is shown that the comb profile significantly depends on geometry of excitation and detection electrodes. Observed strong Duffing nonlinearity below the generation threshold suggests that the system is a phononic analogue to Kerr frequency combs excited in monolithic optical microresonators. The ultra-low power regime opens a way of integrating this phononic system with quantum hybrid systems such as impurity defects and superconducting qubits.
△ Less
Submitted 10 April, 2020; v1 submitted 9 March, 2020;
originally announced March 2020.
-
UPconversion Loop Oscillator Axion Detection experiment: A precision frequency interferometric axion dark matter search with a Cylindrical Microwave Cavity
Authors:
Catriona A. Thomson,
Ben T. McAllister,
Maxim Goryachev,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
First experimental results from a room-temperature table-top phase-sensitive axion haloscope experiment are presented. The technique exploits the axion-photon coupling between two photonic resonator-oscillators excited in a single cavity, allowing low-mass axions to be upconverted to microwave frequencies, acting as a source of frequency modulation on the microwave carriers. This new pathway to ax…
▽ More
First experimental results from a room-temperature table-top phase-sensitive axion haloscope experiment are presented. The technique exploits the axion-photon coupling between two photonic resonator-oscillators excited in a single cavity, allowing low-mass axions to be upconverted to microwave frequencies, acting as a source of frequency modulation on the microwave carriers. This new pathway to axion detection has certain advantages over the traditional haloscope method, particularly in targeting axions below 1 $μ$eV (240 MHz) in energy where high volume magnets are necessary. At the heart of the dual-mode oscillator, a tunable cylindrical microwave cavity supports a pair of orthogonally polarized modes ($\text{TM}_{\text{0,2,0}}$ and $\text{TE}_{\text{0,1,1}}$), which, in general, enables simultaneous sensitivity to axions with masses corresponding to the sum and difference of the microwave frequencies. The results place axion exclusion limits between 7.44 - 19.38 neV, excluding a minimal coupling strength above $3\times 10^{-3}$ 1/GeV, and between 74.4 - 74.5 $μ$eV, excluding a minimal coupling strength above $10^{-2}$ 1/GeV, after a measurement period of two and a half hours. We show that a state-of-the-art frequency-stabilized cryogenic implementation of this technique may achieve competitive limits in a large range of axion-space.
△ Less
Submitted 8 June, 2021; v1 submitted 16 December, 2019;
originally announced December 2019.
-
Piezo-optomechanical coupling of a 3D microwave resonator to a bulk acoustic wave crystalline resonator
Authors:
N. C. Carvalho,
J. Bourhill,
M. Goryachev,
S. Galliou,
M. E. Tobar
Abstract:
We report the observation of coupling between a 3D microwave cavity mode and a bulk mechanical resonator mediated by piezoelectric and radiation pressure effects. The system is composed of a quartz bulk acoustic wave resonator placed inside a microwave re-entrant cavity, which is designed to act as both the electrodes for piezoelectric actuation as well as a 3D resonator. The cavity electromagneti…
▽ More
We report the observation of coupling between a 3D microwave cavity mode and a bulk mechanical resonator mediated by piezoelectric and radiation pressure effects. The system is composed of a quartz bulk acoustic wave resonator placed inside a microwave re-entrant cavity, which is designed to act as both the electrodes for piezoelectric actuation as well as a 3D resonator. The cavity electromagnetic mode is modulated by a 5 MHz bulk acoustic wave shear mode, which is modeled and experimentally verified using the input-output formalism. Through finite element method simulations, we calculate the various contributions to the electromechanical coupling and discuss the potential of the system to reach high cooperativities as well as suitable applications.
△ Less
Submitted 15 September, 2019; v1 submitted 26 May, 2019;
originally announced July 2019.
-
The Electrodynamics of Free and Bound Charge Electricity Generators using Impressed Sources and the Modification to Maxwell's Equations
Authors:
Michael E. Tobar,
Ben T. McAllister,
Maxim Goryachev
Abstract:
The conversion of external energy into electricity is the foundation of power station and energy harvesting operation. The external source supplies an impressed force per unit charge to free or bound charge to produces AC electricity. We analyze the electrodynamics of ideal electricity generators through a time dependent permanent polarization without any applied electric field, which modifies the…
▽ More
The conversion of external energy into electricity is the foundation of power station and energy harvesting operation. The external source supplies an impressed force per unit charge to free or bound charge to produces AC electricity. We analyze the electrodynamics of ideal electricity generators through a time dependent permanent polarization without any applied electric field, which modifies the constitutive relations and is essential to oscillate charge in a lossless way. For both cases, we show that Maxwell's equations, and in particular Faraday's law are modified, along with the required boundary conditions through the addition of an effective impressed magnetic current boundary source. For the free charge case, we highlight the example of an electromagnetic generator based on Lorentz force, where the impressed force per unit charge that polarizes the conductor comes from mechanical motion of free charge with an impressed velocity of a conductor relative to a stationary DC magnetic field. The bound charge generator is an idealized permanently polarized bar electret with a time dependent permanent polarization, the underlying principle behind piezoelectric nano-generators. In the open circuit state, both electricity generators are equivalent to idealized Hertzian dipoles, with the open circuit voltage equal to the induced emf. Analyzing the short circuit responses, we show that the bound charge electricity generator has a capacitive source impedance. In contrast, we show for the ideal free charge AC electricity generator, the back emf from the inductance of the loop that defines the short circuit, directly cancels the source emf, so the voltage across the inductor is solely determined by the magnetic current boundary source. Thus, we determine the magnetic current boundary source is the topological invariant that best describes the output voltage of an AC generator.
△ Less
Submitted 7 January, 2021; v1 submitted 10 April, 2019;
originally announced April 2019.
-
Observation of Low Temperature Magneto-Mechanic Effects in Crystalline Resonant Phonon Cavities
Authors:
Maxim Goryachev,
Serge Galliou,
Michael E. Tobar
Abstract:
We observe magnetic effects in ultra-high quality factor crystalline quartz Bulk Acoustic Wave resonators at milli-Kelvin temperature. The study reveals existence of hysteresis loops, jumps and memory effects of acoustical resonance frequencies. These loops arise as a response to the external magnetic field and span over few Hertz range for modes with linewidths of about $25$mHz, which constitute…
▽ More
We observe magnetic effects in ultra-high quality factor crystalline quartz Bulk Acoustic Wave resonators at milli-Kelvin temperature. The study reveals existence of hysteresis loops, jumps and memory effects of acoustical resonance frequencies. These loops arise as a response to the external magnetic field and span over few Hertz range for modes with linewidths of about $25$mHz, which constitute a frequency shift of order 60 linewidths. The effects are broadband but get stronger towards higher frequencies where both nonlinear effects and losses are limited by two level systems. This suggests that the observed effects are due to ferromagnet-like phase of a spin ensemble coupled to mechanical modes. The observed coupling between mechanical and spin degrees of freedom in the ultra low loss regime brings new possibilities for the emerging class of quantum hybrid systems.
△ Less
Submitted 21 January, 2020; v1 submitted 5 February, 2019;
originally announced February 2019.
-
Broadening Frequency Range of a Ferromagnetic Axion Haloscope with Strongly Coupled Cavity-Magnon Polaritons
Authors:
Graeme Flower,
Jeremy Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
With the axion being a prime candidate for dark matter, there has been some recent interest in direct detection through a so called `Ferromagnetic haloscope.' Such devices exploit the coupling between axions and electrons in the form of collective spin excitations of magnetic materials with the readout through a microwave cavity. Here, we present a new, general, theoretical treatment of such exper…
▽ More
With the axion being a prime candidate for dark matter, there has been some recent interest in direct detection through a so called `Ferromagnetic haloscope.' Such devices exploit the coupling between axions and electrons in the form of collective spin excitations of magnetic materials with the readout through a microwave cavity. Here, we present a new, general, theoretical treatment of such experiments in a Hamiltonian formulation for strongly coupled magnons and photons, which hybridise as cavity-magnon polaritons. Such strongly coupled systems have an extended measurable dispersive regime. Thus, we extend the analysis and operation of such experiments into the dispersive regime, which allows any ferromagnetic haloscope to achieve improved bandwidth with respect to the axion mass parameter space. This experiment was implemented in a cryogenic setup, and initial search results are presented setting laboratory limits on the axion-electron coupling strength of $g_{aee}>3.7\times10^{-9}$ in the range $33.79~μ$eV$< m_a<33.94~μ$eV with $95\%$ confidence. The potential bandwidth of the Ferromagnetic haloscope was calculated to be in two bands, the first of about $1$GHz around $8.24$GHz (or $4.1~μ$eV mass range around $34.1~μ$eV) and the second of about $1.6$GHz around $10$GHz ($6.6~μ$eV mass range around $41.4~μ$eV). Frequency tuning may also be easily achieved via an external magnetic field which changes the ferromagnetic resonant frequency with respect to the cavity frequency. The requirements necessary for future improvements to reach the DFSZ axion model band are discussed in the paper.
△ Less
Submitted 29 March, 2019; v1 submitted 22 November, 2018;
originally announced November 2018.
-
Probing Dark Universe with Exceptional Points
Authors:
Maxim Goryachev,
Ben McAllister,
Michael E. Tobar
Abstract:
It is demonstrated that detection of putative particles such as paraphotons and axions constituting the dark sector of the universe can be reduced to detection of extremely weak links or couplings between cavities and modes. This method allows utilisation of extremely sensitive frequency metrology methods that are not limited by traditional requirements on ultra low temperatures, strong magnetic f…
▽ More
It is demonstrated that detection of putative particles such as paraphotons and axions constituting the dark sector of the universe can be reduced to detection of extremely weak links or couplings between cavities and modes. This method allows utilisation of extremely sensitive frequency metrology methods that are not limited by traditional requirements on ultra low temperatures, strong magnetic fields and sophisticated superconducting technology. We show that exceptional points in the eigenmode structure of coupled modes may be used to boost the sensitivity of dark matter mediated weak links. We find observables that are proportional to fractional powers of fundamental coupling constants. Particularly, in the case of axion detection, it is demonstrated that resonance frequency scaling with $\sim \sqrt{g_{aγγ}θ}$ and $\sim \sqrt[3]{g_{aγγ}θ}$ dependencies can be realised in a ternary photonic cavity system, which is beneficial as these coupling constants are extremely small.
△ Less
Submitted 13 November, 2018; v1 submitted 28 August, 2018;
originally announced September 2018.
-
Modified Axion Electrodynamics as Impressed Electromagnetic Sources Through Oscillating Background Polarization and Magnetization
Authors:
Michael Edmund Tobar,
Ben T. McAllister,
Maxim Goryachev
Abstract:
We present a reformulation of axion modified electrodynamics with all modifications redefined within the constitutive relations between the D,H,B and E fields. This allows the interpretation of the axion induced background bound charge, polarization current and background polarization and magnetization satisfying the charge-current continuity equation. This representation is of similar form to pho…
▽ More
We present a reformulation of axion modified electrodynamics with all modifications redefined within the constitutive relations between the D,H,B and E fields. This allows the interpretation of the axion induced background bound charge, polarization current and background polarization and magnetization satisfying the charge-current continuity equation. This representation is of similar form to photon sector odd-parity Lorentz invariance violating background fields. We show that when a DC B-field is applied an oscillating background polarization is induced at a frequency equivalent to the axion mass. In contrast, when DC E-field is applied, an oscillating background magnetization is induced at a frequency equivalent to the axion mass. We show that these terms are equivalent to impressed source terms, analogous to the way that voltage and current sources are impressed into Maxwell's equations in circuit and antenna theory. The impressed source terms represent the conversion of external energy into electromagnetic energy, and in the case of axion modified electrodynamics this is due to the inverse Primakoff effect converting energy from axions into photons. The axion induced oscillating polarization under a DC magnetic field is analogous to a permanent polarised electret oscillating at the axion Compton frequency, which sources an electromotive force from an effective impressed magnetic current source. In particular, it is shown that the impressed electrical DC current that drives the solenoidal magnetic DC field of an electromagnet, induces an impressed magnetic current parallel to the DC electrical current, oscillating at the Compton frequency of the axion. We show that the magnetic current drives a voltage source through an electric vector potential and also defines the boundary condition of the oscillating axion induced polarization inside and outside the electromagnet.
△ Less
Submitted 31 July, 2019; v1 submitted 5 September, 2018;
originally announced September 2018.
-
Axion Detection with Precision Frequency Metrology
Authors:
Maxim Goryachev,
Ben McAllister,
Michael E. Tobar
Abstract:
We investigate a new class of galactic halo axion detection techniques based on precision frequency and phase metrology. Employing equations of axion electrodynamics, it is demonstrated how a dual mode cavity exhibits linear mode-mode coupling mediated by the axion upconversion and axion downconversion processes. The approach demonstrates phase sensitivity with an ability to detect axion phase wit…
▽ More
We investigate a new class of galactic halo axion detection techniques based on precision frequency and phase metrology. Employing equations of axion electrodynamics, it is demonstrated how a dual mode cavity exhibits linear mode-mode coupling mediated by the axion upconversion and axion downconversion processes. The approach demonstrates phase sensitivity with an ability to detect axion phase with respect to externally pumped signals. Axion signal to phase spectral density conversion is calculated for open and closed loop detection schemes. The fundamental limits of the proposed approach come from the precision of frequency and environment control electronics, rather than fundamental thermal fluctuations allowing for table-top experiments approaching state-of-the-art cryogenic axion searches in sensitivity. Practical realisations are considered, including a TE-TM mode pair in a cylindrical cavity resonator and two orthogonally polarised modes in a Fabry-P{é}rot cavity.
△ Less
Submitted 11 September, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Next Generation of Phonon Tests of Lorentz Invariance using Quartz BAW Resonators
Authors:
Maxim Goryachev,
Zeyu Kuang,
Eugene N. Ivanov,
Philipp Haslinger,
Holger Muller,
Michael E. Tobar
Abstract:
We demonstrate technological improvements in phonon sector tests of Lorentz Invariance that implement quartz Bulk Acoustic Wave oscillators. In this experiment, room temperature oscillators with state-of-the-art phase noise are continuously compared on a platform that rotates at a rate of order a cycle per second. The discussion is focused on improvements in noise measurement techniques, data acqu…
▽ More
We demonstrate technological improvements in phonon sector tests of Lorentz Invariance that implement quartz Bulk Acoustic Wave oscillators. In this experiment, room temperature oscillators with state-of-the-art phase noise are continuously compared on a platform that rotates at a rate of order a cycle per second. The discussion is focused on improvements in noise measurement techniques, data acquisition and data processing. Preliminary results of the second generation of such tests are given, and indicate that SME coefficients in the matter sector can be measured at a precision of order $10^{-16}$ GeV after taking a years worth of data. This is equivalent to an improvement of two orders of magnitude over the prior acoustic phonon sector experiment.
△ Less
Submitted 7 April, 2018;
originally announced April 2018.
-
Broadband Axion Dark Matter Haloscopes via Electric Sensing
Authors:
Ben T. McAllister,
Maxim Goryachev,
Jeremy Bourhill,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohi…
▽ More
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohibitively large. Broadband low-mass detectors have already been proposed using inductive magnetometer sensors and a gapped toroidal solenoid magnet. In this work we propose an alternative, which uses electric sensors in a conventional solenoidal magnet aligned in the laboratory z-axis, as implemented in standard haloscope experiments. In the presence of the DC magnetic field, the inverse Primakoff effect causes a time varying permanent electric vacuum polarization in the z-direction to oscillate at the axion Compton frequency, which induces an oscillating electromotive force. We propose non-resonant techniques to detect this oscillating elctromotive force by implementing a capacitive sensor or an electric dipole antenna coupled to a low noise amplifier. We present the first experimental results and discuss the foundations and potential of this proposal. Preliminary results constrain $g_{aγγ} >\sim2.35\times10^{-12}$ $\text{GeV}^{-1}$ in the mass range of $2.08\times10^{-11}$ to $2.2\times10^{-11}$ eV, and demonstrate potential sensitivity to axion-like dark matter with masses in the range of $10^{-12}$ to $10^{-8}$ eV.
△ Less
Submitted 26 October, 2018; v1 submitted 21 March, 2018;
originally announced March 2018.