-
Open-cavity in closed-cycle cryostat as a quantum optics platform
Authors:
Samarth Vadia,
Johannes Scherzer,
Holger Thierschmann,
Clemens Schäfermeier,
Claudio Dal Savio,
Takashi Taniguchi,
Kenji Watanabe,
David Hunger,
Khaled Karraï,
Alexander Högele
Abstract:
The introduction of an optical resonator can enable efficient and precise interaction between a photon and a solid-state emitter. It facilitates the study of strong light-matter interaction, polaritonic physics and presents a powerful interface for quantum communication and computing. A pivotal aspect in the progress of light-matter interaction with solid-state systems is the challenge of combinin…
▽ More
The introduction of an optical resonator can enable efficient and precise interaction between a photon and a solid-state emitter. It facilitates the study of strong light-matter interaction, polaritonic physics and presents a powerful interface for quantum communication and computing. A pivotal aspect in the progress of light-matter interaction with solid-state systems is the challenge of combining the requirements of cryogenic temperature and high mechanical stability against vibrations while maintaining sufficient degrees of freedom for in-situ tunability. Here, we present a fiber-based open Fabry-Pérot cavity in a closed-cycle cryostat exhibiting ultra-high mechanical stability while providing wide-range tunability in all three spatial directions. We characterize the setup and demonstrate the operation with the root-mean-square cavity length fluctuation of less than $90$ pm at temperature of $6.5$ K and integration bandwidth of $100$ kHz. Finally, we benchmark the cavity performance by demonstrating the strong-coupling formation of exciton-polaritons in monolayer WSe$_2$ with a cooperativity of $1.6$. This set of results manifests the open-cavity in a closed-cycle cryostat as a versatile and powerful platform for low-temperature cavity QED experiments.
△ Less
Submitted 1 December, 2021; v1 submitted 9 March, 2021;
originally announced March 2021.
-
Analysis of a single-mode waveguide at sub-terahertz frequencies as a communication channel
Authors:
Marc Westig,
Holger Thierschmann,
Allard Katan,
Matvey Finkel,
Teun M. Klapwijk
Abstract:
We study experimentally the transmission of an electro-magnetic waveguide in the frequency range from 160 to 300 GHz. Photo-mixing is used to excite and detect the fundamental TE10 mode in a rectangular waveguide with two orders-of-magnitude lower impedance. The large impedance mismatch leads to a strong frequency dependence of the transmission, which we measure with a high-dynamic range of up to…
▽ More
We study experimentally the transmission of an electro-magnetic waveguide in the frequency range from 160 to 300 GHz. Photo-mixing is used to excite and detect the fundamental TE10 mode in a rectangular waveguide with two orders-of-magnitude lower impedance. The large impedance mismatch leads to a strong frequency dependence of the transmission, which we measure with a high-dynamic range of up to 80 dB, and with high frequency-resolution. The modified transmission function is directly related to the information rate of the waveguide, which we estimate to be about 1 bit per photon. We suggest that the results are applicable to a Josephson junction employed as a single-photon source and coupled to a superconducting waveguide to achieve a simple on-demand narrow-bandwidth free-space number-state channel.
△ Less
Submitted 19 September, 2019;
originally announced September 2019.
-
Local electrodynamics of a disordered conductor model system measured with a microwave impedance microscope
Authors:
Holger Thierschmann,
Hale Cetinay,
Matvey Finkel,
Allard J. Katan,
Marc P. Westig,
Piet Van Mieghem,
Teun M. Klapwijk
Abstract:
We study the electrodynamic impedance of percolating conductors with a pre-defined network topology using a scanning microwave impedance microscope (sMIM) at GHz frequencies. For a given percolation number we observe strong spatial variations across a sample which correlate with the connected regions (clusters) in the network when the resistivity is low such as in Aluminum. For the more resistive…
▽ More
We study the electrodynamic impedance of percolating conductors with a pre-defined network topology using a scanning microwave impedance microscope (sMIM) at GHz frequencies. For a given percolation number we observe strong spatial variations across a sample which correlate with the connected regions (clusters) in the network when the resistivity is low such as in Aluminum. For the more resistive material NbTiN the impedance becomes dominated by the local structure of the percolating network (connectivity). The results can qualitatively be understood and reproduced with a network current spreading model based on the pseudo-inverse Laplacian of the underlying network graph.
△ Less
Submitted 26 August, 2019;
originally announced August 2019.
-
Shielded cantilever with on-chip interferometer circuit for THz scanning probe impedance microscopy
Authors:
Matvey Finkel,
Holger Thierschmann,
Allard J. Katan,
Marc P. Westig,
Marco Spirito,
Teun M. Klapwijk
Abstract:
We have realized a microstrip based THz near field cantilever which enables quantitative measurements of the impedance of the probe tip at THz frequencies (0.3 THz). A key feature is the on-chip balanced hybrid coupler which serves as an interferometer for passive signal cancellation to increase the readout circuit sensitivity despite extreme impedance mismatch at the tip. We observe distinct chan…
▽ More
We have realized a microstrip based THz near field cantilever which enables quantitative measurements of the impedance of the probe tip at THz frequencies (0.3 THz). A key feature is the on-chip balanced hybrid coupler which serves as an interferometer for passive signal cancellation to increase the readout circuit sensitivity despite extreme impedance mismatch at the tip. We observe distinct changes in the reflection coefficient of the tip when brought into contact with different dielectric (Si, SrTiO3) and metallic samples (Au). By comparing to finite element simulations we determine the sensitivity of our THz probe to be well below 0.25 fF. The cantilever further allows for topography imaging in a conventional atomic force microscope mode. Our THz cantilever removes several critical technology challenges and thus enables a shielded cantilever based THz near field microscope.
△ Less
Submitted 27 June, 2019;
originally announced June 2019.