Skip to main content

Showing 1–10 of 10 results for author: Testa, E

Searching in archive physics. Search in all archives.
.
  1. arXiv:2411.07670  [pdf

    physics.med-ph

    Comparison of Geant4-DNA and RITRACKS/RITCARD: microdosimetry, nanodosimetry and DNA break predictions

    Authors: Victor Levrague, R. Delorme, Mathieu Roccia, Ngoc Hoang Tran, Sebastien Incerti, Michael Beuve, Etienne Testa, Ianik Plante, Shirin Rahmanian, Floriane Poignant

    Abstract: This work aims at investigating the impact of DNA geometry, compaction and calculation chain on DNA break and chromosome aberration predictions for high charge and energy (HZE) ions, using the Monte Carlo codes Geant4-DNA, RITRACKS and RITCARD. To ensure consistency of ion transport of both codes, we first compared microdosimetry and nanodosimetry spectra for different ions of interest in hadronth… ▽ More

    Submitted 12 November, 2024; originally announced November 2024.

    Journal ref: 20th International Conference on the use of Computers in Radiation Therapy (ICCR), Jul 2024, Lyon, France, France

  2. arXiv:2409.13257  [pdf, other

    physics.med-ph

    Biophysical modeling of low-energy ion irradiations with NanOx

    Authors: Mario Alcocer-Ávila, Victor Levrague, Rachel Delorme, Étienne Testa, Michaël Beuve

    Abstract: Background: Targeted radiotherapies with low-energy ions show interesting possibilities for the selective irradiation of tumor cells, a strategy particularly appropriate for the treatment of disseminated cancer. Two promising examples are boron neutron capture therapy (BNCT) and targeted radionuclide therapy with alpha-particle emitters (TAT). The successful clinical translation of these radiother… ▽ More

    Submitted 20 September, 2024; originally announced September 2024.

  3. arXiv:2112.11575  [pdf, other

    physics.med-ph physics.ins-det

    Relative stopping power precision in time-of-flight proton CT

    Authors: Nils Krah, Denis Dauvergne, Jean Michel Létang, Simon Rit, Étienne Testa

    Abstract: Proton computed tomography (CT) is similar to x-ray CT but relies on protons rather than photons to form an image. In its most common operation mode, the measured quantity is the amount of energy that a proton has lost while traversing the imaged object from which a relative stopping power map can be obtained via tomographic reconstruction. To this end, a calorimeter which measures the energy depo… ▽ More

    Submitted 21 December, 2021; originally announced December 2021.

  4. arXiv:2105.05053  [pdf, other

    physics.ins-det physics.med-ph

    Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring

    Authors: Sébastien Curtoni, Marie-Laure Gallin-Martel, Sara Marcatili, Latifa Abbassi, Alexandre Bes, Germain Bosson, Johann Collot, Thierry Crozes, Denis Dauvergne, Wout De Nolf, Pierre Everaere, Laurent Gallin-Martel, Abderrahmane Ghimouz, Ferid Haddad, Christophe Hoarau, Jean-Yves Hostachy, Charbel Koumeir, Ana Lacoste, Vincent Métivier, John Morse, Jean-François Motte, Jean-François Muraz, Freddy Poirier, Fatah Ellah Rarbi, Olivier Rossetto , et al. (4 additional authors not shown)

    Abstract: In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv… ▽ More

    Submitted 23 August, 2021; v1 submitted 11 May, 2021; originally announced May 2021.

    Comments: 15 pages, 9 figures

  5. arXiv:2101.02079  [pdf, other

    physics.ins-det physics.med-ph

    Characterization of a beam-tagging hodoscope for hadrontherapy monitoring

    Authors: O. Allegrini, J. -P. Cachemiche, C. P. C. Caplan, B. Carlus, X. Chen, S. Curtoni, D. Dauvergne, R. Della Negra, M. -L. Gallin-Martel, J. Hérault, J. M. Létang, C. Morel, É. Testa, Y. Zoccarato

    Abstract: A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber… ▽ More

    Submitted 6 January, 2021; originally announced January 2021.

    Comments: 17 pages, 18 figures

  6. A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy

    Authors: Maxime Jacquet, Sara Marcatili, Marie-Laure Gallin-Martel, Jean-Luc Bouly, Yannick Boursier, Denis Dauvergne, Mathieu Dupont, Laurent Gallin-Martel, Joël Hérault, Jean-Michel Létang, Daniel Manéval, Christian Morel, Jean-François Muraz, Étienne Testa

    Abstract: We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam… ▽ More

    Submitted 16 December, 2020; originally announced December 2020.

  7. arXiv:2001.04222  [pdf

    physics.med-ph physics.ins-det

    A 100 ps TOF Detection System for On-Line Range- Monitoring in Hadrontherapy

    Authors: Sara Marcatili, Sébastien Curtoni, Denis Dauvergne, Ferid Haddad, Maxime Jacquet, Charbel Koumeir, Jean Michel Létang, Jayde Livingstone, Vincent Métivier, Laurent Gallin-Martel, Marie-Laure Gallin-Martel, Jean-François Muraz, Noel Servagent, Étienne Testa

    Abstract: The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respec… ▽ More

    Submitted 20 January, 2020; v1 submitted 13 January, 2020; originally announced January 2020.

    Comments: 4 pages, 6 figures

  8. arXiv:2001.01470  [pdf, other

    physics.med-ph physics.ins-det

    Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy

    Authors: S. Marcatili, J. Collot, S. Curtoni, D. Dauvergne, J-Y. Hostachy, C. Koumeir, J. M. Létang, J. Livingstone, V. Métivier, L. Gallin-Martel, M-L. Gallin-Martel, J. F. Muraz, N. Servagent, É. Testa, M. Yamouni

    Abstract: In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in… ▽ More

    Submitted 6 January, 2020; originally announced January 2020.

    Comments: 17 pages, 18 figures

  9. Statistical effects of dose deposition in track-structure modelling of radiobiology efficiency

    Authors: M. Beuve, A. Colliaux, D. Dabli, D. Dauvergne, B. Gervais, G. Montarou, E. Testa

    Abstract: Ion-induced cell killing has been reported to depend on the irradiation dose but also on the projectile parameters. In this paper we focus on two approaches developed and extensively used to predict cell survival in response to ion irradiation: the Local Effect Model and the Katz Model. These models are based on a track-structure description summarized in the concept of radial dose. This latter… ▽ More

    Submitted 25 February, 2009; originally announced February 2009.

    Comments: 32 pages ; 8 figures

    Journal ref: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 267 (2009) 983-988

  10. arXiv:0809.0185  [pdf, ps, other

    physics.atom-ph

    Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt $γ$-ray measurements

    Authors: E. Testa, M. Bajard, M. Chevallier, D. Dauvergne, F. Le Foulher, J. -C. Poizat, C. Ray, M. Testa, N. Freud, J. -M. Létang

    Abstract: By means of a time-of-flight technique, we measured the longitudinal profile of prompt $γ$-rays emitted by 73 MeV/u $^{13}$C ions irradiating a PMMA target. This technique allowed us to minimize the shielding against neutrons and scattered $γ$-rays, and to correlate prompt gamma emission to the ion path. This correlation, together with a high counting rate, paves the way toward real-time monitor… ▽ More

    Submitted 1 September, 2008; originally announced September 2008.

    Comments: to be published in Applied Physics Letters

    Journal ref: Applied Physics Letters 93 (2008) 093506