-
XDoppler axial velocity estimation using row-column arrays
Authors:
Henri Leroy,
Adrien Bertolo,
Guillaume Goudot,
Mickael Tanter,
Thomas Deffieux,
Mathieu Pernot
Abstract:
Accurate volumetric velocity estimation in ultrasound imaging is crucial for applications in diagnostic and therapeutic medicine. Traditional ultrasound systems, while effective in two-dimensional imaging, face significant challenges in achieving 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes present a promising alternative, reducing hardware com…
▽ More
Accurate volumetric velocity estimation in ultrasound imaging is crucial for applications in diagnostic and therapeutic medicine. Traditional ultrasound systems, while effective in two-dimensional imaging, face significant challenges in achieving 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes present a promising alternative, reducing hardware complexity, thus contributing to bridge the gap between research and clinical systems. Yet, this usually comes at the cost of lower signal-to-noise ratio (SNR), reduced sensitivity and stronger sidelobes compared to 3D matrices, even though recent methods have tried to tackle the later issue. In this study, we introduce a method to use the phase of the signals acquired by rows and columns of RCA arrays to compute a new velocity estimator based on cross correlation of orthogonal apertures, extending the XDoppler scheme initially introduced for power Doppler imaging to the estimation of velocities. Our results indicate that XDoppler estimator can measure faithfully axial velocities (RMSE=9.21%, R2=0.88) and outperforms the traditional phase shift autocorrelator with a theoretical Nyquist velocity twice higher. Moreover, the in vitro data indicate a better sensitivity to flow velocities below 10mm/s and a lower bias for flow rate estimation (-0.17mL/min as opposed to -9.33mL/min for reference method). In vivo data acquired on a carotid artery confirm the reduced sensitivity to aliasing effects and show that this new technique can dynamically follow blood velocity evolutions linked to arterial pulsatility. This suggests that this new estimator could be of use for improved volumetric blood velocity imaging with a RCA probe.
△ Less
Submitted 18 June, 2025;
originally announced June 2025.
-
Imaging the dynamics of cardiac fiber orientation in vivo using 3D Ultrasound Backscatter Tensor Imaging
Authors:
Clement Papadacci,
Victor Finel,
Jean Provost,
Olivier Villemain,
Patrick Bruneval,
Jean-Luc Gennisson,
Mickael Tanter,
Mathias Fink,
Mathieu Pernot
Abstract:
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dy…
▽ More
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dynamics with a temporal resolution of 10 ms during a single cardiac cycle, non-invasively and in vivo in entire volumes. 3D-BTI is based on ultrafast volumetric ultrasound acquisitions, which are used to quantify the spatial coherence of backscattered echoes at each point of the volume. The capability of 3D-BTI to map the fibers orientation was evaluated in vitro in 5 myocardial samples. The helicoidal transmural variation of fiber angles was in good agreement with the one obtained by histological analysis. 3D-BTI was then performed to map the fiber orientation dynamics in vivo in the beating heart of an open-chest sheep at a volume rate of 90 volumes/s. Finally, the clinical feasibility of 3D-BTI was shown on a healthy volunteer. These initial results indicate that 3D-BTI could become a fully non-invasive technique to assess myocardial disarray at the bedside of patients.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Boosting transducer matrix sensitivity for 3D large field ultrasound localization microscopy using a multi-lens diffracting layer: a simulation study
Authors:
Hugues Favre,
Mathieu Pernot,
Mickael Tanter,
Clément Papadacci
Abstract:
Mapping blood microflows of the whole brain is crucial for early diagnosis of cerebral diseases. Ultrasound localization microscopy (ULM) was recently applied to map and quantify blood microflows in 2D in the brain of adult patients down to the micron scale. Whole brain 3D clinical ULM remains challenging due to the transcranial energy loss which significantly reduces the imaging sensitivity. Larg…
▽ More
Mapping blood microflows of the whole brain is crucial for early diagnosis of cerebral diseases. Ultrasound localization microscopy (ULM) was recently applied to map and quantify blood microflows in 2D in the brain of adult patients down to the micron scale. Whole brain 3D clinical ULM remains challenging due to the transcranial energy loss which significantly reduces the imaging sensitivity. Large aperture probes with a large surface can increase both resolution and sensitivity. However, a large active surface implies thousands of acoustic elements, with limited clinical translation. In this study, we investigate via simulations a new high-sensitive 3D imaging approach based on large diverging elements, combined with an adapted beamforming with corrected delay laws, to increase sensitivity. First, pressure fields from single elements with different sizes and shapes were simulated. High directivity was measured for curved element while maintaining high transmit pressure. Matrix arrays of 256 elements with a dimension of 10x10 cm with small ( $λ$ /2), large (4 $λ$ ), and curved elements (4 $λ$ ) were compared through point spread functions analysis. A large synthetic microvessel phantom filled with 100 microbubbles per frame was imaged using the matrix arrays in a transcranial configuration. 93% of the bubbles were detected with the proposed approach demonstrating that the multi-lens diffracting layer has a strong potential to enable 3D ULM over a large field of view through the bones.
△ Less
Submitted 11 April, 2023;
originally announced April 2023.
-
In vivo Adaptive Focusing for Clinical Contrast-Enhanced Transcranial Ultrasound Imaging in Human
Authors:
Justine Robin,
Charlie Demené,
Baptiste Heiles,
Victor Blanvillain,
Liene Puke,
Fabienne Perren-Landis,
Mickael Tanter
Abstract:
Imaging the human brain vasculature with high spatial and temporal resolution remains challenging in the clinic today. Transcranial ultrasound is scarcely used for cerebrovascular imaging, due to low sensitivity and strong phase aberrations induced by the skull bone that only enable major brain vessel imaging, even with ultrasound contrast agent injection (microbubbles). Here, we propose an adapti…
▽ More
Imaging the human brain vasculature with high spatial and temporal resolution remains challenging in the clinic today. Transcranial ultrasound is scarcely used for cerebrovascular imaging, due to low sensitivity and strong phase aberrations induced by the skull bone that only enable major brain vessel imaging, even with ultrasound contrast agent injection (microbubbles). Here, we propose an adaptive aberration correction technique for skull bone aberrations based on the backscattered signals coming from intravenously injected microbubbles. Our aberration correction technique was implemented to image brain vasculature in adult humans through temporal and occipital bone windows. For each patient, an effective speed of sound, as well as a phase aberration profile, were determined in several isoplanatic patches spread across the image. This information was then used in the beamforming process. It improved image quality both for ultrafast Doppler imaging and Ultrasound Localization Microscopy (ULM), especially in cases of thick bone windows. For ultrafast Doppler images, the contrast was increased by 4dB on average, and for ULM, the number of detected microbubble tracks was increased by 38%. This technique is thus promising for better diagnosis and follow-up of brain pathologies such as aneurysms or stroke and could make transcranial ultrasound imaging possible even in particularly difficult-to-image patients.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
4D ultrafast ultrasound imaging of naturally occurring shear waves in the human heart
Authors:
Clement Papadacci,
V. Finel,
O. Villemain,
M. Tanter,
M. Pernot
Abstract:
The objectives were to develop a novel three-dimensional technology for imaging naturally occurring shear wave (SW) propagation, demonstrate feasibility on human volunteers and quantify SW velocity in different propagation directions. Imaging of natural SWs generated by valve closures has emerged to obtain a direct measurement of cardiac stiffness. Recently, natural SW velocity was assessed in two…
▽ More
The objectives were to develop a novel three-dimensional technology for imaging naturally occurring shear wave (SW) propagation, demonstrate feasibility on human volunteers and quantify SW velocity in different propagation directions. Imaging of natural SWs generated by valve closures has emerged to obtain a direct measurement of cardiac stiffness. Recently, natural SW velocity was assessed in two dimensions on parasternal long axis view under the assumption of a propagation direction along the septum. However, in this approach the source localization and the complex three-dimensional propagation wave path was neglected making the speed estimation unreliable. High volume rate transthoracic acquisitions of the human left ventricle (1100 volume/s) was performed with a 4D ultrafast echocardiographic scanner. Four-dimensional tissue velocity cineloops enabled visualization of aortic and mitral valve closure waves. Energy and time of flight mapping allowed propagation path visualization and source localization, respectively. Velocities were quantified along different directions. Aortic and mitral valve closure SW velocities were assessed for the three volunteers with low standard deviation. Anisotropic propagation was also found suggesting the necessity of using a three-dimensional imaging approach. Different velocities were estimated for the three directions for the aortic (3.4$\pm$0.1 m/s, 3.5$\pm$0.3 m/s, 5.4$\pm$0.7 m/s) and the mitral (2.8$\pm$0.5 m/s, 2.9$\pm$0.3 m/s, 4.6$\pm$0.7 m/s) valve SWs. 4D ultrafast ultrasound alleviates the limitations of 2D ultrafast ultrasound for cardiac SW imaging based on natural SW propagations and enables a comprehensive measurement of cardiac stiffness. This technique could provide stiffness mapping of the left ventricle.
△ Less
Submitted 9 October, 2020;
originally announced October 2020.
-
A versatile and robust microfluidic device for capillary-sized simple or multiple emulsions production
Authors:
E. Teston,
V. Hingot,
V. Faugeras,
C. Errico,
M. Bezagu,
M. Tanter,
O. Couture
Abstract:
Ultrasound-vaporizable microdroplets can be exploited for targeted drug delivery. However, it requires customized microfluidic techniques able to produce monodisperse, capillary-sized and biocompatible multiple emulsions. Recent development of microfluidic devices led to the optimization of microdroplet production with high yields, low polydispersity and well-defined diameters. So far, only few we…
▽ More
Ultrasound-vaporizable microdroplets can be exploited for targeted drug delivery. However, it requires customized microfluidic techniques able to produce monodisperse, capillary-sized and biocompatible multiple emulsions. Recent development of microfluidic devices led to the optimization of microdroplet production with high yields, low polydispersity and well-defined diameters. So far, only few were shown to be efficient for simple droplets or multiple emulsions production below 5 microns in diameter, which is required to prevent microembolism after intravenous injection. Here, we present a versatile microchip for both simple and multiple emulsion production. This parallelized system based on microchannel emulsification was designed to produce perfluorocarbon in water or water within perfluorocarbon in water emulsions with capillary sizes (<5 $μ$m) and polydispersity index down to 5 % for in vivo applications such as spatiotemporally-triggered drug delivery using Ultrasound. We show that droplet production at this scale is mainly controlled by interfacial tension forces, how capillary and viscosity ratios influence droplet characteristics and how different production regimes may take place. The better understanding of droplet formation and its relation to applied pressures is supported by observations with a high-speed camera. Compared to previous microchips, this device opens perspectives to produce injectable and biocompatible droplets with a reasonable yield in order to realize preclinical studies in mice.
△ Less
Submitted 6 December, 2019;
originally announced December 2019.
-
3-D Longitudinal Imaging of Tumor Angiogenesis in Mice in Vivo Using Ultrafast Doppler Tomography
Authors:
Charlie Demené,
Thomas Payen,
Alexandre Dizeux,
Guillaume Barrois,
Jean-Luc Gennisson,
Lori Bridal,
Mickael Tanter
Abstract:
Angiogenesis, the formation of new vessels, is one of the key mechanisms in tumor development and an appealing target for therapy. Non-invasive, high-resolution, high sensitivity, quantitative 3D imaging techniques are required to correctly depict tumor heterogeneous vasculature over time. Ultrafast Doppler was recently introduced and provides an unprecedented combination of resolution, penetratio…
▽ More
Angiogenesis, the formation of new vessels, is one of the key mechanisms in tumor development and an appealing target for therapy. Non-invasive, high-resolution, high sensitivity, quantitative 3D imaging techniques are required to correctly depict tumor heterogeneous vasculature over time. Ultrafast Doppler was recently introduced and provides an unprecedented combination of resolution, penetration depth and sensitivity without requiring any contrast agents. The technique was further extended to 3D with Ultrafast Doppler Tomography (UFD-T). In this work, UFD-T was applied to the monitoring of tumor angiogenesis in vivo providing structural and functional information at different stages of development. UFD-T volume renderings showed that our murine model's vasculature stems from pre-existing vessels and sprouts to perfuse the whole volume as the tumor grows until a critical size is reached. Then, as the network becomes insufficient, the tumor core is no longer irrigated because the vasculature is mainly concentrated in the periphery. In addition to spatial distribution and growth patterns, UFD-T allowed a quantitative analysis of vessel size and length, revealing that the diameter-distribution of vessels remained relatively constant throughout tumor growth. The network is dominated by small vessels at all stages of tumor development with more than 74% of the vessels less than 200 $μ$m in diameter. This study also showed that cumulative vessel length is more closely related to tumor radius than volume, indicating that the vascularization becomes insufficient when a critical mass is reached. UFD-T was also compared with dynamic contrast-enhanced ultrasound (DCE-US) and shown to provide complementary information regarding the link between structure and perfusion. In conclusion, UFD-T is capable of an in vivo quantitative assessment of the development of tumor vasculature (vessels with blood speed >1mm/s (sensitivity limit) assessed with a resolution limit of 80 $μ$m) in 3D. The technique has very interesting potential as a tool for treatment monitoring, response assessment and treatment planning for optimal drug efficiency.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.
-
Non-invasive Evaluation of Aortic Stiffness Dependence with Aortic Blood Pressure and Internal Radius by Shear Wave Elastography and Ultrafast Imaging
Authors:
Clement Papadacci,
T. Mirault,
B. Dizier,
M. Tanter,
E. Messas,
M. Pernot
Abstract:
Elastic properties of arteries have long been recognized as playing a major role in the cardiovascular system. However, non-invasive in vivo assessment of local arterial stiffness remains challenging and imprecise as current techniques rely on indirect estimates such as wall deformation or pulse wave velocity. Recently, Shear Wave Elastography (SWE) has been proposed to non-invasively assess the i…
▽ More
Elastic properties of arteries have long been recognized as playing a major role in the cardiovascular system. However, non-invasive in vivo assessment of local arterial stiffness remains challenging and imprecise as current techniques rely on indirect estimates such as wall deformation or pulse wave velocity. Recently, Shear Wave Elastography (SWE) has been proposed to non-invasively assess the intrinsic arterial stiffness. In this study, we applied SWE in the abdominal aortas of rats while increasing blood pressure (BP) to investigate the dependence of shear wave speed with invasive arterial pressure and non-invasive arterial diameter measurements. A 15MHz linear array connected to an ultrafast ultrasonic scanner, set non-invasively, on the abdominal aorta of anesthetized rats (N=5) was used. The SWE acquisition followed by an ultrafast (UF) acquisition was repeated at different moment of the cardiac cycle to assess shear wave speed and arterial diameter variations respectively. Invasive arterial BP catheter placed in the carotid, allowed the accurate measurement of pressure responses to increasing does of phenylephrine infused via a venous catheter. The SWE acquisition coupled to the UF acquisition was repeated for different range of pressure. For normal range of BP, the shear wave speed was found to follow the aortic BP variation during a cardiac cycle. A minimum of (5.06$\pm$0.82) m/s during diastole and a maximum of (5.97$\pm$0.90) m/s during systole was measured. After injection of phenylephrine, a strong increase of shear wave speed (13.85$\pm$5.51) m/s was observed for a peak systolic arterial pressure of (190$\pm$10) mmHg. A non-linear relationship between shear wave speed and arterial BP was found. A complete non-invasive method was proposed to characterize the artery with shear wave speed combined with arterial diameter variations. Finally, the results were validated against two parameters the incremental elastic modulus and the pressure elastic modulus derived from BP and arterial diameter variations.
△ Less
Submitted 2 May, 2019;
originally announced May 2019.
-
Optimal spatiotemporal focusing through complex scattering media
Authors:
Jochen Aulbach,
Alice Bretagne,
Mathias Fink,
Mickaël Tanter,
Arnaud Tourin
Abstract:
We present a new approach for spatiotemporal focusing through complex scattering media by wave front shaping. Using a nonlinear feedback signal to shape the incident pulsed wave front, we show that the limit of a spatiotemporal matched filter can be achieved, i.e., the wave amplitude at the intended time and focus position is maximized for a given input energy. It is exactly what is also achieved…
▽ More
We present a new approach for spatiotemporal focusing through complex scattering media by wave front shaping. Using a nonlinear feedback signal to shape the incident pulsed wave front, we show that the limit of a spatiotemporal matched filter can be achieved, i.e., the wave amplitude at the intended time and focus position is maximized for a given input energy. It is exactly what is also achieved with time-reversal. Demonstrated with ultrasound experiments, our method is generally applicable to all types of waves.
△ Less
Submitted 22 February, 2013;
originally announced February 2013.