-
The S$π$RIT Time Projection Chamber
Authors:
J. Barney,
J. Estee,
W. G. Lynch,
T. Isobe,
G. Jhang,
M. Kurata-Nishimura,
A. B. McIntosh,
T. Murakami,
R. Shane,
S. Tangwancharoen,
M. B. Tsang,
G. Cerizza,
M. Kaneko,
J. W. Lee,
C. Y. Tsang,
R. Wang,
C. Anderson,
H. Baba,
Z. Chajecki,
M. Famiano,
R. Hodges-Showalter,
B. Hong,
T. Kobayashi,
P. Lasko,
J. Łukasik
, et al. (15 additional authors not shown)
Abstract:
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096…
▽ More
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$π$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$π$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
Charged particle track reconstruction with S$π$RIT Time Projection Chamber
Authors:
J. W. Lee,
G. Jhang,
G. Cerizza,
J. Barney,
J. Estee,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
W. G. Lynch,
T. Murakami,
C. Y. Tsang,
M. B. Tsang,
R. Wang,
B. Hong,
A. B. McIntosh,
H. Sakurai,
C. Santamaria,
R. Shane,
S. Tangwancharoen,
S. J. Yennello,
Y. Zhang
Abstract:
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overla…
▽ More
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from $^{132}$Sn + $^{124}$Sn collision events with beam energy of 270 AMeV. Particle identification is established using $\left<dE/dx\right>$ and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.
△ Less
Submitted 10 January, 2020;
originally announced January 2020.
-
A Gating Grid Driver for Time Projection Chambers
Authors:
S. Tangwancharoen,
W. G. Lynch,
J. Barney,
J. Estee,
R. Shane,
M. B. Tsang,
Y. Zhang,
T. Isobe,
M. Kurata-Nishimura,
T. Murakami,
Z. G. Xiao,
Y. F. Zhang
Abstract:
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wir…
▽ More
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 $μ$s. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 $μ$s. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 $μ$s.
△ Less
Submitted 20 December, 2016;
originally announced December 2016.
-
S$π$RIT: A time-projection chamber for symmetry-energy studies
Authors:
R. Shane,
A. McIntosh,
T. Isobe,
W. G. Lynch,
H. Baba,
J. Barney,
Z. Chajecki,
M. Chartier,
J. Estee,
M. Famiano,
B. Hong,
K. Ieki,
G. Jhang,
R. Lemmon,
F. Lu,
T. Murakami,
N. Nakatsuka,
M. Nishimura,
R. Olsen,
W. Powell,
H. Sakurai,
A. Taketani,
S. Tangwancharoen,
M. B. Tsang,
T. Usukura
, et al. (3 additional authors not shown)
Abstract:
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN t…
▽ More
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN to measure yield ratios for pions and other light isospin multiplets produced in central collisions of neutron-rich heavy ions, such as $^{132}$Sn + $^{124}$Sn. The S$π$RIT TPC can function both as a TPC detector and as an active target. It has a vertical drift length of 50 cm, parallel to the magnetic field. Gas multiplication is achieved through the use of a multi-wire anode. Image charges are produced in the 12096 pads, and are read out with the recently developed Generic Electronics for TPCs.
△ Less
Submitted 22 September, 2014;
originally announced September 2014.