-
Record-high-Q AMTIR-1 microresonators for mid- to long-wave infrared nonlinear photonics
Authors:
Liu Yang,
Ryo Sugano,
Ryomei Takabayashi,
Hajime Kumazaki,
Yongyong Zhuang,
Xiaoyong Wei,
Takasumi Tanabe,
Shun Fujii
Abstract:
AMTIR-1 chalcogenide glass has shown its potential for use in thermal imaging systems owing to its low refractive index, thermal resistance and high transparency across the infrared wavelength regime. Here we report a millimeter-scale high-Q whispering gallery mode microresonator made of AMTIR-1. The recorded Q-factor has reached $1.2\times10^7$ at 1550~nm, which is almost two-orders of magnitude…
▽ More
AMTIR-1 chalcogenide glass has shown its potential for use in thermal imaging systems owing to its low refractive index, thermal resistance and high transparency across the infrared wavelength regime. Here we report a millimeter-scale high-Q whispering gallery mode microresonator made of AMTIR-1. The recorded Q-factor has reached $1.2\times10^7$ at 1550~nm, which is almost two-orders of magnitude higher than previously reported values. We characterize the thermal properties, where low thermal conductivity plays an important role in thermal resonance tuning. We further show that AMTIR-1 resonators support anomalous dispersion as well as a low absorption coefficient near the 7~\textmu m wavelength band, thus offering the possibility of providing suitable platforms for mid-infrared, long-wave infrared nonlinear optics including microresonator frequency comb generation.
△ Less
Submitted 29 May, 2025;
originally announced May 2025.
-
Improved absolute frequency measurement of $^{171}$Yb at NMIJ with uncertainty below $2\times10^{-16}$
Authors:
Takumi Kobayashi,
Akiko Nishiyama,
Kazumoto Hosaka,
Daisuke Akamatsu,
Akio Kawasaki,
Masato Wada,
Hajime Inaba,
Takehiko Tanabe,
Masami Yasuda
Abstract:
We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional unc…
▽ More
We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of $1.9\times10^{-16}$, in good agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of $^{171}$Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.
△ Less
Submitted 26 February, 2025;
originally announced February 2025.
-
Architecture for coherent dual-comb spectroscopy and low-noise photonic microwave generation using mechanically actuated soliton microcombs
Authors:
Tatsuki Murakami,
Koshiro Wada,
Soma Kogure,
Ryomei Takabayashi,
Liu Yang,
Riku Shibata,
Hajime Kumazaki,
Shinichi Watanabe,
Atsushi Ishizawa,
Takasumi Tanabe,
Shun Fujii
Abstract:
Dissipative Kerr soliton microcombs have inspired various intriguing applications such as spectroscopy, ranging, telecommunication, and high purity microwave generation. Mechanically actuated soliton microcombs provide enhanced controllability and flexibility for Kerr solitons, thus enabling technological progress to be made on such practical applications. Here, we present architectures for cohere…
▽ More
Dissipative Kerr soliton microcombs have inspired various intriguing applications such as spectroscopy, ranging, telecommunication, and high purity microwave generation. Mechanically actuated soliton microcombs provide enhanced controllability and flexibility for Kerr solitons, thus enabling technological progress to be made on such practical applications. Here, we present architectures for coherent dual-comb techniques and ultralow-noise microwave generation by exploiting the mechanical actuation of ultrahigh-Q crystalline microresonators. By unifying a pump laser, we demonstrate highly coherent dual-soliton combs using distinct resonators with slightly different repetition rates. We also report significant phase noise reduction achieved by directly generating Kerr solitons from a sub-Hz linewidth ultrastable laser. This study paves the way for further advancements in a wide variety of applications based on Kerr soliton microcombs.
△ Less
Submitted 31 December, 2024;
originally announced January 2025.
-
Scalable fabrication of erbium-doped high-Q silica microtoroid resonators via sol-gel coating
Authors:
Riku Imamura,
Shun Fujii,
Keigo Nagashima,
Takasumi Tanabe
Abstract:
This study explores sol-gel methods for fabricating erbium-doped silica microtoroid resonators, addressing the limitations of conventional doping techniques and enhancing device scalability. We develop a reproducible sol-gel process that yields defect-free films for photonic applications, and detail common defects and troubleshooting strategies. Two fabrication methods are compared: traditional fi…
▽ More
This study explores sol-gel methods for fabricating erbium-doped silica microtoroid resonators, addressing the limitations of conventional doping techniques and enhancing device scalability. We develop a reproducible sol-gel process that yields defect-free films for photonic applications, and detail common defects and troubleshooting strategies. Two fabrication methods are compared: traditional film deposition on substrates and the direct coating of prefabricated resonators. The latter enables the fabrication of larger resonator diameters (up to 450 μm) without buckling, while achieving a high-Q factor and a low lasing threshold of 350 μW. These erbium-doped resonators exhibit multi-mode laser oscillations at 1550 nm, revealing the sol-gel method's potential for realizing scalable, gain-doped photonic devices.
△ Less
Submitted 17 November, 2024;
originally announced November 2024.
-
High Level Reconstruction with Deep Learning using ILD Full Simulation
Authors:
Taikan Suehara,
Risako Tagami,
Lai Gui,
Tatsuki Murata,
Tomohiko Tanabe,
Wataru Ootani,
Masaya Ishino
Abstract:
Deep learning can give a significant impact on physics performance of electron-positron Higgs factories such as ILC and FCCee. We are working on two topics on event reconstruction to apply deep learning. The first is jet flavor tagging, in which we apply particle transformer to ILD full simulation to obtain jet flavor, including strange tagging. The second is particle flow, which clusters calorime…
▽ More
Deep learning can give a significant impact on physics performance of electron-positron Higgs factories such as ILC and FCCee. We are working on two topics on event reconstruction to apply deep learning. The first is jet flavor tagging, in which we apply particle transformer to ILD full simulation to obtain jet flavor, including strange tagging. The second is particle flow, which clusters calorimeter hits and assigns tracks to them to improve jet energy resolution. We modified the algorithm developed in context of CMS HGCAL based on GravNet and Object Condensation techniques and add a track-cluster assignment function into the network. The overview and performance of these algorithms are described.
△ Less
Submitted 11 October, 2024;
originally announced October 2024.
-
Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Kazumoto Hosaka,
Yusuke Hisai,
Akiko Nishiyama,
Akio Kawasaki,
Masato Wada,
Hajime Inaba,
Takehiko Tanabe,
Feng-Lei Hong,
Masami Yasuda
Abstract:
We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb op…
▽ More
We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Isotope-shift analysis with the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition in ytterbium
Authors:
Akio Kawasaki,
Takumi Kobayashi,
Akiko Nishiyama,
Takehiko Tanabe,
Masami Yasuda
Abstract:
Measurements of isotope shifts have recently been attracting considerable attention due to their potentials in searching for new forces. We report on the isotope shifts of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in Yb, based on absolute frequency measurements with an accuracy of $\sim10$ kHz. With these data, the hyperfine constants for $^{173}$Yb are determined. To an…
▽ More
Measurements of isotope shifts have recently been attracting considerable attention due to their potentials in searching for new forces. We report on the isotope shifts of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in Yb, based on absolute frequency measurements with an accuracy of $\sim10$ kHz. With these data, the hyperfine constants for $^{173}$Yb are determined. To analyze these data further, electronic structure of ytterbium is theoretically calculated. The nuclear charge radii are estimated together with some previously reported isotope-shift data for other transitions. An analysis of the King plot for the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition shows a good consistency with other transitions, resulting in a constraint on the existence of new bosons mediating the force between an electron and a neutron. The analysis motivates further precision measurements on isotope shifts of the narrow-linewidth transitions in ytterbium, not only for the even-mass isotopes but also for the odd-mass isotopes.
△ Less
Submitted 13 June, 2024; v1 submitted 21 February, 2024;
originally announced February 2024.
-
Exceptional point proximity-driven mode-locking in coupled microresonators
Authors:
Riku Imamura,
Shun Fujii,
Ayata Nakashima,
Takasumi Tanabe
Abstract:
We show theoretically and numerically that mode-locking is feasible with a coupled-cavity system with gain and loss, notably, without any natural saturable absorber. We highlight that in the vicinity of the exceptional point, system $Q$ exhibits substantial modulation even with minor refractive index changes and a minimal Kerr effect contribution. Leveraging this unique behaviour, we propose an un…
▽ More
We show theoretically and numerically that mode-locking is feasible with a coupled-cavity system with gain and loss, notably, without any natural saturable absorber. We highlight that in the vicinity of the exceptional point, system $Q$ exhibits substantial modulation even with minor refractive index changes and a minimal Kerr effect contribution. Leveraging this unique behaviour, we propose an unprecedented approach wherein the lossy auxiliary cavity functions as an efficient artificial saturable absorber, thus facilitating mode-locking. This approach is not only novel, but also presents considerable advantages over conventional systems where both gain and saturable absorption are contained within a single microcavity. These benefits include reduced operational power and ease of post-adjustment, achievable through the manipulation of the coupling strength between the two microcavities.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
Mechanically actuated Kerr soliton microcombs
Authors:
Shun Fujii,
Koshiro Wada,
Soma Kogure,
Takasumi Tanabe
Abstract:
Mode-locked ultrashort pulse sources with a repetition rate of up to several tens of gigahertz greatly facilitate versatile photonic applications such as frequency synthesis, metrology, radar, and optical communications. Dissipative Kerr soliton microcombs provide an attractive solution as a broadband, high-repetition-rate compact laser system in this context. However, its operation usually requir…
▽ More
Mode-locked ultrashort pulse sources with a repetition rate of up to several tens of gigahertz greatly facilitate versatile photonic applications such as frequency synthesis, metrology, radar, and optical communications. Dissipative Kerr soliton microcombs provide an attractive solution as a broadband, high-repetition-rate compact laser system in this context. However, its operation usually requires sophisticated pump laser control to initiate and stabilize the soliton microcombs, particularly in millimeter-sized ultrahigh-Q whispering-gallery resonators. Here, we realize a mechanically actuated soliton microcomb oscillator with a microwave repetition rate of 15 GHz. This enables direct soliton initiation, long-term stabilization, and fine tuning, where the operation now lifts the prerequisite pump laser tunability that must be relaxed if the technology is to be widely used outside the laboratory environment. We reveal the prospects for using this method with a wide range of applications that would benefit from mechanical soliton actuation such as optical clocks, spectral extension, and dual-comb spectroscopy.
△ Less
Submitted 3 June, 2023;
originally announced June 2023.
-
Observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ clock transition at 431 nm in $^{171}$Yb
Authors:
Akio Kawasaki,
Takumi Kobayashi,
Akiko Nishiyama,
Takehiko Tanabe,
Masami Yasuda
Abstract:
We report on the observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in $^{171}$Yb by depleting atoms in a magneto-optical trap formed by the $6s^{2}~^1S_0-6s6p~^3P_1$ intercombination transition. The absolute frequency of the transition to the $F=3/2$ state is determined to be $695~171~054~858.1(8.2)$~kHz against physical realization of Coordinated Universal Time m…
▽ More
We report on the observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in $^{171}$Yb by depleting atoms in a magneto-optical trap formed by the $6s^{2}~^1S_0-6s6p~^3P_1$ intercombination transition. The absolute frequency of the transition to the $F=3/2$ state is determined to be $695~171~054~858.1(8.2)$~kHz against physical realization of Coordinated Universal Time maintained by the National Metrology Institute of Japan with a frequency comb. The $g$ factor of the transition to the $F=3/2$ state and the A hyperfine constant are measured to be $g_J=1.54(13)$ and 1123.354(13)~MHz, respectively. More precise spectroscopy of this transition can lead to searches for time variation of the fine structure constant and searches for new physics with isotope shift measurements.
△ Less
Submitted 24 March, 2024; v1 submitted 21 March, 2023;
originally announced March 2023.
-
Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks
Authors:
Takumi Kobayashi,
Akifumi Takamizawa,
Daisuke Akamatsu,
Akio Kawasaki,
Akiko Nishiyama,
Kazumoto Hosaka,
Yusuke Hisai,
Masato Wada,
Hajime Inaba,
Takehiko Tanabe,
Masami Yasuda
Abstract:
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark m…
▽ More
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from $10^{-22}$ eV/$c^{2}$ to $10^{-20}$ eV/$c^{2}$ are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the $^{171}$Yb clock transition is also determined as $518\,295\,836\,590\,863.69(28)$ Hz, which is one of the important contributions towards a redefinition of the SI second.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
Versatile tuning of Kerr soliton microcombs in crystalline microresonators
Authors:
Shun Fujii,
Koshiro Wada,
Ryo Sugano,
Hajime Kumazaki,
Soma Kogure,
Yuichiro K. Kato,
Takasumi Tanabe
Abstract:
Microresonator-based optical frequency combs emitted from high-quality-factor microresonators, also known as microcombs, have opened up new horizons to areas of optical frequency comb technology including frequency metrology, precision sensing, and optical communication. To extend the capability of microcombs for such applications, large and reliable tunability is of critical importance. Here, we…
▽ More
Microresonator-based optical frequency combs emitted from high-quality-factor microresonators, also known as microcombs, have opened up new horizons to areas of optical frequency comb technology including frequency metrology, precision sensing, and optical communication. To extend the capability of microcombs for such applications, large and reliable tunability is of critical importance. Here, we show broad spectral tuning of Kerr soliton microcombs in a thermally controlled crystalline microresonator with pump-detuning stabilization. The fundamental elements composing frequency combs, namely the center frequency, repetition frequency, and carrier-envelope offset frequency, are spectrally tuned by up to -48.8 GHz, -5.85 MHz, and -386 MHz, respectively, leveraging thermal effects in ultrahigh-Q crystalline magnesium fluoride resonators. We further demonstrate a 3.4-fold enhancement of soliton comb power resulting from thermal expansion with a temperature change of only 28 K by employing quantitative analyses of the fiber-to-resonator coupling efficiency.
△ Less
Submitted 2 March, 2023; v1 submitted 28 June, 2022;
originally announced June 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Deterministic generation of a perfect soliton crystal with a saturable absorber
Authors:
Ayata Nakashima,
Shun Fujii,
Riku Imamura,
Keigo Nagashima,
Takasumi Tanabe
Abstract:
We numerically investigate the deterministic generation of a perfect soliton crystal (PSC) in an optical microresonator functionalized with a saturable absorber (SA). The SA allows the direct formation of a PSC from an initial, periodic Turing roll. It prevents passage through a chaotic state, which induces a stochastic nature as regards the number of generated dissipative Kerr solitons. We show t…
▽ More
We numerically investigate the deterministic generation of a perfect soliton crystal (PSC) in an optical microresonator functionalized with a saturable absorber (SA). The SA allows the direct formation of a PSC from an initial, periodic Turing roll. It prevents passage through a chaotic state, which induces a stochastic nature as regards the number of generated dissipative Kerr solitons. We show that PSCs form deterministically, and the number is controlled by adjusting the input power and SA parameter. Our work provides a simple approach for obtaining a stable PSC that offers an ultra-high repetition rate and a high comb output power.
△ Less
Submitted 22 December, 2021;
originally announced December 2021.
-
Dissipative Kerr soliton microcombs for FEC-free optical communications over 100 channels
Authors:
Shun Fujii,
Shuya Tanaka,
Tamiki Ohtsuka,
Soma Kogure,
Koshiro Wada,
Hajime Kumazaki,
Shun Tasaka,
Yosuke Hashimoto,
Yuta Kobayashi,
Tomohiro Araki,
Kentaro Furusawa,
Norihiko Sekine,
Satoki Kawanishi,
Takasumi Tanabe
Abstract:
The demand for high-speed and highly efficient optical communication techniques has been rapidly growing due to the ever-increasing volume of data traffic. As well as the digital coherent communication used for core and metro networks, intensity modulation and direct detection (IM-DD) are still promising schemes in intra/inter data centers thanks to their low latency, high reliability, and good co…
▽ More
The demand for high-speed and highly efficient optical communication techniques has been rapidly growing due to the ever-increasing volume of data traffic. As well as the digital coherent communication used for core and metro networks, intensity modulation and direct detection (IM-DD) are still promising schemes in intra/inter data centers thanks to their low latency, high reliability, and good cost performance. In this work, we study a microresonator-based frequency comb as a potential light source for future IM-DD optical systems where applications may include replacing individual stabilized lasers with a continuous laser driven microresonator. Regarding comb line powers and spectral intervals, we compare a modulation instability comb and a soliton microcomb and provide a quantitative analysis with regard to telecom applications. Our experimental demonstration achieved a forward error correction (FEC) free operation of bit-error rate (BER) <10^(-9) with a 1.45 Tbps capacity using a total of 145 lines over the entire C-band and revealed the possibility of soliton microcomb-based ultra-dense wavelength division multiplexing (WDM) with a simple, cost-effective IM-DD scheme, with a view to future practical use in data centers.
△ Less
Submitted 20 December, 2021; v1 submitted 29 October, 2021;
originally announced November 2021.
-
Selective crystal growth of indium selenide compounds from saturated solutions grown in a selenium vapor
Authors:
Chao Tang,
Yohei Sato,
Katsuya Watanabe,
Tadao Tanabe,
Yutaka Oyama
Abstract:
Indium selenide compounds are promising materials for energy conversion, spintronic applications, and chemical sensing. However, it is difficult to grow stoichiometric indium selenide crystals due to the high equilibrium selenium vapor pressure and the complicated phase equilibrium system of indium selenide compounds. In this paper, we apply a novel and convenient crystal growth method, in which t…
▽ More
Indium selenide compounds are promising materials for energy conversion, spintronic applications, and chemical sensing. However, it is difficult to grow stoichiometric indium selenide crystals due to the high equilibrium selenium vapor pressure and the complicated phase equilibrium system of indium selenide compounds. In this paper, we apply a novel and convenient crystal growth method, in which the saturated solution is grown by the application of a selenium vapor. In this method, selenium vapor at a pressure higher than the saturated vapor pressure is applied to molten indium, such that the selenium continuously dissolves into the indium solution until the solubility at the growth temperature is reached; then a slow cooling process results in crystallization. The selenium dose is matched to its solubility so that indium selenide compounds can be selectively grown just by controlling the temperature without the need to consider the chemical ratio in the solution. The pressure of the vapor is controlled during the whole growth process so that any deviation from a stoichiometric composition in the crystal can be controlled. Both InSe and In2Se3 were successfully grown using this method, and we have investigated the growth mechanism and found the growth window for each compound. This study presents a novel and convenient approach to fabricating transitional metal chalcogenides without deficiencies in the chalcogen element.
△ Less
Submitted 19 October, 2021;
originally announced October 2021.
-
Design of a passively mode-locking whispering gallery mode microaser
Authors:
Tomoki S. L. Prugger Suzuki,
Ayata Nakashima,
Keigo Nagashima,
Rammaru Ishida,
Riku Imamura,
Shun Fujii,
Sze Yun Set,
Shinji Yamashita,
Takasumi Tanabe
Abstract:
Ultrahigh repetition rate lasers will become vital light sources for many future technologies; however, their realization is challenging because the cavity size must be minimized. Whispering-gallery-mode (WGM) microresonators are attractive for this purpose since they allow the strong light-matter interaction usually needed to enable mode-locking. However, the optimum parameter ranges are entirely…
▽ More
Ultrahigh repetition rate lasers will become vital light sources for many future technologies; however, their realization is challenging because the cavity size must be minimized. Whispering-gallery-mode (WGM) microresonators are attractive for this purpose since they allow the strong light-matter interaction usually needed to enable mode-locking. However, the optimum parameter ranges are entirely unknown since no experiments have yet been conducted. Here, we numerically investigate pulsed operation in a toroidal WGM microresonator with gain and saturable absorption (SA) to study the experimental feasibility. We show that dispersion is the key parameter for achieving passive mode-locking in this system. Moreover, the design guideline provided in this work can apply to any small resonators with gain and SA and is not limited to a specific cavity system.
△ Less
Submitted 13 June, 2021;
originally announced June 2021.
-
Ultrahigh-Q crystalline microresonator fabrication with only precision machining
Authors:
Shun Fujii,
Yuka Hayama,
Kosuke Imamura,
Hajime Kumazaki,
Yasuhiro Kakinuma,
Takasumi Tanabe
Abstract:
The development of ultrahigh quality factor (Q) microresonators has been driving such technologies as cavity quantum electrodynamics (QED), high-precision sensing, optomechanics, and optical frequency comb generation. Here we report ultrahigh-Q crystalline microresonator fabrication with a Q exceeding $10^8$, for the first time, achieved solely by computer-controlled ultraprecision machining. Our…
▽ More
The development of ultrahigh quality factor (Q) microresonators has been driving such technologies as cavity quantum electrodynamics (QED), high-precision sensing, optomechanics, and optical frequency comb generation. Here we report ultrahigh-Q crystalline microresonator fabrication with a Q exceeding $10^8$, for the first time, achieved solely by computer-controlled ultraprecision machining. Our fabrication method readily achieved the dispersion engineering and size control of fabricated devices via programmed machine motion. Moreover, in contrast to the conventional polishing method, our machining fabrication approach avoids the need for subsequent careful polishing, which is generally required to ensure that surface integrity is maintained, and this enabled us to realize an ultrahigh-Q. We carefully addressed the cutting condition and crystal anisotropy to overcome the large surface roughness that has thus far been the primary cause of the low-Q in the machining process. Our result paves the way for future mass-production with a view to various photonic applications utilizing ultrahigh-Q crystalline microresonators.
△ Less
Submitted 7 September, 2020; v1 submitted 19 April, 2020;
originally announced April 2020.
-
Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories
Authors:
Takanori Mogi,
Tomohiko Tanabe,
Wataru Ootani,
Satoru Yamashita,
Ryousuke Shirai,
Tohru Takeshita,
Yazhou Niu,
Jianbei Liu
Abstract:
Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order to meet these requirements, scintillator strips with a small dimple has been proposed. In our study, we measure the light yield of a dimple scintillator sample…
▽ More
Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order to meet these requirements, scintillator strips with a small dimple has been proposed. In our study, we measure the light yield of a dimple scintillator sample; we then compare the measurements with light tracing simulation using GEANT4. We intend to use our results to propose an optimized scintillator shape.
△ Less
Submitted 15 February, 2020;
originally announced February 2020.
-
Coupling of a whispering gallery mode to a silicon chip with photonic crystal
Authors:
Yuyang Zhuang,
Hajime Kumazaki,
Shun Fujii,
Riku Imamura,
Nurul Ashikin Binti Daud,
Rammaru Ishida,
Heming Chen,
Takasumi Tanabe
Abstract:
We demonstrate the efficient coupling (99.5%) of a silica whispering gallery mode microresonator directly with a silicon chip by using a silicon photonic crystal waveguide as a coupler. The efficient coupling is attributed to the small effective refractive index difference between the two devices. The large group index of the photonic crystal waveguide mode also contributes to the efficient coupli…
▽ More
We demonstrate the efficient coupling (99.5%) of a silica whispering gallery mode microresonator directly with a silicon chip by using a silicon photonic crystal waveguide as a coupler. The efficient coupling is attributed to the small effective refractive index difference between the two devices. The large group index of the photonic crystal waveguide mode also contributes to the efficient coupling. A coupling Q of 2.68*10^6 is obtained, which allows us to achieve the critical coupling of a silica whispering gallery mode with an intrinsic Q of close to 10^7 with a Si chip.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Octave-wide phase-matched four-wave mixing in dispersion engineered crystalline microresonators
Authors:
Shun Fujii,
Shuya Tanaka,
Mika Fuchida,
Hikaru Amano,
Yuka Hayama,
Ryo Suzuki,
Yusuhiro Kakinuma,
Takasumi Tanabe
Abstract:
In this Letter, we report phase-matched four-wave mixing separated by over one-octave in a dispersion engineered crystalline microresonator. Experimental and numerical results presented here confirm that primary sidebands were generated with a frequency shift up to 140 THz, and that secondary sidebands formed a localized comb structure, known as a clustered comb in the vicinity of the primary side…
▽ More
In this Letter, we report phase-matched four-wave mixing separated by over one-octave in a dispersion engineered crystalline microresonator. Experimental and numerical results presented here confirm that primary sidebands were generated with a frequency shift up to 140 THz, and that secondary sidebands formed a localized comb structure, known as a clustered comb in the vicinity of the primary sidebands. A theoretical analysis of the phase-matching condition validated our experimental observations, and our results good agree well with numerical simulations. These results offer the potential to realize a frequency tunable comb cluster generator operating from 1 um to mid-infrared wavelengths with a single and compact device.
△ Less
Submitted 23 March, 2020; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Yusuke Hisai,
Takehiko Tanabe,
Hajime Inaba,
Tomonari Suzuyama,
Feng-Lei Hong,
Kazumoto Hosaka,
Masami Yasuda
Abstract:
We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequen…
▽ More
We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrmμ$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Authors:
Daisuke Akamatsu,
Takumi Kobayashi,
Yusuke Hisai,
Takehiko Tanabe,
Kazumoto Hosaka,
Masami Yasuda,
Feng-Lei Hong
Abstract:
We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trapping $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configura…
▽ More
We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trapping $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configurations, respectively, resulting in a small distance of the order of 100 $μ$m between the trapped Sr and Yb atoms. The $^{1}$S$_{0}$-$^{3}$P$_{0}$ clock transitions in the trapped atoms were interrogated in turn and the clock lasers were stabilized to the transitions. We demonstrated the frequency ratio measurement of the Sr and Yb clock transitions by using the dual-mode operation of the Sr-Yb optical lattice clock. The dual-mode operation can reduce the uncertainty of the blackbody radiation shift in the frequency ratio measurement, because both Sr and Yb atoms share the same blackbody radiation.
△ Less
Submitted 6 June, 2018;
originally announced June 2018.
-
A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp
Authors:
Takehiko Tanabe,
Daisuke Akamatsu,
Hajime Inaba,
Sho Okubo,
Takumi Kobayashi,
Masami Yasuda,
Kazumoto Hosaka,
Feng-Lei Hong
Abstract:
We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $τ= 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and det…
▽ More
We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $τ= 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the ${\rm {^1}S_{0} - {^1}P_{1}}$ transition in $^{174}\mathrm{Yb}$ was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.
△ Less
Submitted 18 May, 2018;
originally announced May 2018.
-
Brillouin lasing in coupled silica toroid microcavities
Authors:
Yoshihiro Honda,
Wataru Yoshiki,
Tomohiro Tetsumoto,
Shun Fujii,
Kentaro Furusawa,
Norihiko Sekine,
Takasumi Tanabe
Abstract:
We demonstrate stimulated Brillouin scattering (SBS) lasing in a strongly coupled microcavity system. By coupling two silica toroid microcavities, we achieve large mode splitting of 11 GHz, whose frequency separation matches the Brillouin frequency shift of silica. The SBS light is resonantly amplified by pumping at the higher frequency side of the supermode splitting resonance. Since the mode spl…
▽ More
We demonstrate stimulated Brillouin scattering (SBS) lasing in a strongly coupled microcavity system. By coupling two silica toroid microcavities, we achieve large mode splitting of 11 GHz, whose frequency separation matches the Brillouin frequency shift of silica. The SBS light is resonantly amplified by pumping at the higher frequency side of the supermode splitting resonance. Since the mode splitting is adjusted by changing the gap distance between the two cavities, our system does not require precise control of a mm-sized cavity diameter to match the free-spectral spacing with the Brillouin frequency shift. It also allows us to use a small cavity, hence our system has the potential to achieve the lasing threshold at a very low power.
△ Less
Submitted 24 December, 2017;
originally announced December 2017.
-
Broadband gain induced Raman comb formation in a silica microresonator
Authors:
Ryo Suzuki,
Akihiro Kubota,
Atsuhiro Hori,
Shun Fujii,
Takasumi Tanabe
Abstract:
A high-Q silica whispering-gallery mode microresonator is an attractive platform on which to demonstrate a broad and phase-locked Raman comb in various wavelength regimes. Raman combs can be used for applications such as compact pulse laser sources, sensors, optical clocks, and coherence tomography. However, the formation dynamics of a Raman comb has not been well exploited. Here we study the dyna…
▽ More
A high-Q silica whispering-gallery mode microresonator is an attractive platform on which to demonstrate a broad and phase-locked Raman comb in various wavelength regimes. Raman combs can be used for applications such as compact pulse laser sources, sensors, optical clocks, and coherence tomography. However, the formation dynamics of a Raman comb has not been well exploited. Here we study the dynamics of the Raman comb formation in silica rod microresonators, which have cavity free spectral ranges in microwave rates. We generated a Raman comb with a smooth spectral envelope and also observed the transition between two Raman combs located at different center wavelengths. The transition behavior was obtained when we changed the pump detuning and the coupling strength between the microresonator and fiber. We also explain these phenomena by using a simple model based on coupled mode equations.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Transition between Kerr comb and stimulated Raman comb in a silica whispering gallery mode microcavity
Authors:
Shun Fujii,
Takumi Kato,
Ryo Suzuki,
Atsuhiro Hori,
Takasumi Tanabe
Abstract:
We theoretically and experimentally investigated the transition between modulation instability and Raman gain in a small silica microcavity with a large free-spectral range (FSR), which reveals that we can selectively switch from a four-wave mixing dominant state to a stimulated Raman scattering dominant state. Both the theoretical analysis and the experiment show that a Raman-dominant region is p…
▽ More
We theoretically and experimentally investigated the transition between modulation instability and Raman gain in a small silica microcavity with a large free-spectral range (FSR), which reveals that we can selectively switch from a four-wave mixing dominant state to a stimulated Raman scattering dominant state. Both the theoretical analysis and the experiment show that a Raman-dominant region is present between transitions of Kerr combs with different free-spectral range spacings. We can obtain a stable Kerr comb and a stable Raman state selectively by changing the driving power, coupling between the cavity and the waveguide, and laser detuning. Such a controllable transition is achieved thanks to the presence of gain competition between modulation instability and Raman gain in silica whispering gallery mode microcavities.
△ Less
Submitted 12 December, 2017;
originally announced December 2017.
-
The effect on Kerr comb generation in a clockwise and counter-clockwise mode coupled microcavity
Authors:
Shun Fujii,
Atsuhiro Hori,
Takumi Kato,
Ryo Suzuki,
Yusuke Okabe,
Wataru Yoshiki,
Akitoshi Chen-Jinnai,
Takasumi Tanabe
Abstract:
We study the impact of inherent mode coupling between clockwise (CW) and counter-clockwise (CCW) modes on Kerr comb generation in a small whispering-gallery mode microcavity. Our numerical analysis using a coupled Lugiato-Lefever equation reveals the range of the coupling strength in which a soliton pulse can be obtained in the CW direction. It also showed that CCW comb power depends on the coupli…
▽ More
We study the impact of inherent mode coupling between clockwise (CW) and counter-clockwise (CCW) modes on Kerr comb generation in a small whispering-gallery mode microcavity. Our numerical analysis using a coupled Lugiato-Lefever equation reveals the range of the coupling strength in which a soliton pulse can be obtained in the CW direction. It also showed that CCW comb power depends on the coupling strength between the CW and CCW modes. In addition to the simulation, we conducted an experiment to confirm that the power ratio between the CW and CCW comb modes depends on the coupling strength, and the experimental results agree well with the simulation results. This study helps us to understand the relationship between CW and CCW mode coupling and Kerr comb generation, and the effect on soliton formation.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
Second harmonic generation at 399 nm resonant on the $^{1}S_{0}-^{1}P_{1}$ transition of ytterbium using a periodically poled LiNbO$_{3}$ waveguide
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Yoshiki Nishida,
Takehiko Tanabe,
Masami Yasuda,
Feng-Lei Hong,
Kazumoto Hosaka
Abstract:
We demonstrate a compact and robust method for generating a 399-nm light resonant on the $^{1}S_{0}-^{1}P_{1}$ transition in ytterbium using a single-pass periodically poled LiNbO$_{3}$ waveguide for second harmonic generation (SHG). The obtained output power at 399 nm was 25 mW when a 798-nm fundamental power of 380 mW was coupled to the waveguide. We observed no degradation of the SHG power for…
▽ More
We demonstrate a compact and robust method for generating a 399-nm light resonant on the $^{1}S_{0}-^{1}P_{1}$ transition in ytterbium using a single-pass periodically poled LiNbO$_{3}$ waveguide for second harmonic generation (SHG). The obtained output power at 399 nm was 25 mW when a 798-nm fundamental power of 380 mW was coupled to the waveguide. We observed no degradation of the SHG power for 13 hours with a low power of 6 mW. The obtained SHG light has been used as a seed light for injection locking, which provides sufficient power for laser cooling ytterbium.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Kazumoto Hosaka,
Hajime Inaba,
Sho Okubo,
Takehiko Tanabe,
Masami Yasuda,
Atsushi Onae,
Feng-Lei Hong
Abstract:
We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibration…
▽ More
We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.
△ Less
Submitted 23 March, 2016;
originally announced March 2016.
-
Improved frequency measurement of the $^1S_{0}$-$^3P_{0}$ clock transition in $^{87}$Sr using the Cs fountain clock at NMIJ as a transfer oscillator
Authors:
Takehiko Tanabe,
Daisuke Akamatsu,
Takumi Kobayashi,
Akifumi Takamizawa,
Shinya Yanagimachi,
Takeshi Ikegami,
Tomonari Suzuyama,
Hajime Inaba,
Sho Okubo,
Masami Yasuda,
Feng-Lei Hong,
Atsushi Onae,
Kazumoto Hosaka
Abstract:
We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value…
▽ More
We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.
△ Less
Submitted 14 September, 2015;
originally announced September 2015.
-
LCFIPlus: A Framework for Jet Analysis in Linear Collider Studies
Authors:
Taikan Suehara,
Tomohiko Tanabe
Abstract:
We report on the progress in flavor identification tools developed for a future $e^+e^-$ linear collider such as the International Linear Collider (ILC) and Compact Linear Collider (CLIC). Building on the work carried out by the LCFIVertex collaboration, we employ new strategies in vertex finding and jet finding, and introduce new discriminating variables for jet flavor identification. We present…
▽ More
We report on the progress in flavor identification tools developed for a future $e^+e^-$ linear collider such as the International Linear Collider (ILC) and Compact Linear Collider (CLIC). Building on the work carried out by the LCFIVertex collaboration, we employ new strategies in vertex finding and jet finding, and introduce new discriminating variables for jet flavor identification. We present the performance of the new algorithms in the conditions simulated using a detector concept designed for the ILC. The algorithms have been successfully used in ILC physics simulation studies, such as those presented in the ILC Technical Design Report.
△ Less
Submitted 28 June, 2015;
originally announced June 2015.
-
A compact iodine-laser operating at 531 nm with stability at the 10$^{-12}$ level and using a coin-sized laser module
Authors:
Takumi Kobayashi,
Daisuke Akamatsu,
Kazumoto Hosaka,
Hajime Inaba,
Sho Okubo,
Takehiko Tanabe,
Masami Yasuda,
Atsushi Onae,
Feng-Lei Hong
Abstract:
We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves fr…
▽ More
We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves frequency stability at the 10$^{-12}$ level. The absolute frequency of the compact laser stabilized to the $a_{1}$ hyperfine component of the $R(36)32-0$ transition is determined as $564\,074\,632\,419(8)$ kHz with a relative uncertainty of $1.4\times10^{-11}$. The iodine-stabilized laser can be used for various applications including interferometric measurements.
△ Less
Submitted 21 June, 2015;
originally announced June 2015.
-
Physics Case for the International Linear Collider
Authors:
Keisuke Fujii,
Christophe Grojean,
Michael E. Peskin,
Tim Barklow,
Yuanning Gao,
Shinya Kanemura,
Hyungdo Kim,
Jenny List,
Mihoko Nojiri,
Maxim Perelstein,
Roman Poeschl,
Juergen Reuter,
Frank Simon,
Tomohiko Tanabe,
Jaehoon Yu,
James D. Wells,
Hitoshi Murayama,
Hitoshi Yamamoto
Abstract:
We summarize the physics case for the International Linear Collider (ILC). We review the key motivations for the ILC presented in the literature, updating the projected measurement uncertainties for the ILC experiments in accord with the expected schedule of operation of the accelerator and the results of the most recent simulation studies.
We summarize the physics case for the International Linear Collider (ILC). We review the key motivations for the ILC presented in the literature, updating the projected measurement uncertainties for the ILC experiments in accord with the expected schedule of operation of the accelerator and the results of the most recent simulation studies.
△ Less
Submitted 26 June, 2015; v1 submitted 19 June, 2015;
originally announced June 2015.
-
Harmonic mode locking in a high-Q whispering gallery mode microcavity
Authors:
Takumi Kato,
Tomoya Kobatake,
Ryo Suzuki,
Zhelun Chen,
Takasumi Tanabe
Abstract:
A numerical and experimental study of the generation of harmonic mode locking in a silica toroid microcavity is presented. We use a generalized mean-field Lugiato-Lefever equation and solve it with the split-step Fourier method. We found that stable harmonic mode locking regime can be accessed when we reduce the input power after strong pumping even when we do not carefully adjust the wavelength d…
▽ More
A numerical and experimental study of the generation of harmonic mode locking in a silica toroid microcavity is presented. We use a generalized mean-field Lugiato-Lefever equation and solve it with the split-step Fourier method. We found that stable harmonic mode locking regime can be accessed when we reduce the input power after strong pumping even when we do not carefully adjust the wavelength detuning. This is due to the bistable nature of the nonlinear cavity system. The experiment agrees well with the numerical analysis, where we obtain low-noise Kerr comb spectrum at low longitudinal mode spacing by gradually reducing the pumping input after strong pumping. This finding clarifies the procedure for generating harmonic mode locking in such high-Q microcavity systems.
△ Less
Submitted 6 August, 2014;
originally announced August 2014.
-
All-optical switching using Kerr effect in a silica toroid microcavity
Authors:
Wataru Yoshiki,
Takasumi Tanabe
Abstract:
We demonstrate experimentally an all-optical switching operation using the Kerr effect in a silica toroid microcavity. Thanks to the small mode volume and high quality factor of the silica toroid microcavity, we achieved on-chip optical Kerr switching with an input power of 2 mW. This value is the smallest among all previously reported on-chip optical Kerr switches. We also show that this value ca…
▽ More
We demonstrate experimentally an all-optical switching operation using the Kerr effect in a silica toroid microcavity. Thanks to the small mode volume and high quality factor of the silica toroid microcavity, we achieved on-chip optical Kerr switching with an input power of 2 mW. This value is the smallest among all previously reported on-chip optical Kerr switches. We also show that this value can be reduced to a few tens of uW by employing a mode with a Q factor of >2x10^7.
△ Less
Submitted 10 July, 2014;
originally announced July 2014.
-
High-Q silica zipper cavity for optical radiation pressure driven MOMS switch
Authors:
Tomohiro Tetsumoto,
Takasumi Tanabe
Abstract:
We design a silica zipper cavity that has high optical and mechanical Q (quality factor) values and demonstrate numerically the feasibility of a radiation pressure driven micro opto-mechanical system (MOMS) directional switch. The silica zipper cavity has an optical Q of 6.0x10^4 and an effective mode volume Vmode of 0.66λ^3 when the gap between two cavities is 34 nm. We found that this Q/V_mode v…
▽ More
We design a silica zipper cavity that has high optical and mechanical Q (quality factor) values and demonstrate numerically the feasibility of a radiation pressure driven micro opto-mechanical system (MOMS) directional switch. The silica zipper cavity has an optical Q of 6.0x10^4 and an effective mode volume Vmode of 0.66λ^3 when the gap between two cavities is 34 nm. We found that this Q/V_mode value is five times higher than can be obtained with a single nanocavity design. The mechanical Q (Q_m) is determined by thermo-elastic damping and is 2.0x10^6 in a vacuum at room temperature. The opto-mechanical coupling rate g_OM is as high as 100 GHz/nm, which allows us to move the directional cavity-waveguide system and switch 1550-nm light with 770-nm light by controlling the radiation pressure.
△ Less
Submitted 14 May, 2014;
originally announced May 2014.
-
Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks
Authors:
Daisuke Akamatsu,
Masami Yasuda,
Hajime Inaba,
Kazumoto Hosaka,
Takehiko Tanabe,
Atsushi Onae,
Feng-Lei Hong
Abstract:
The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the ratio (ν_{Yb}/ν_{Sr}) to be 1.207 507 039 343 340 4(18) with a fractional uncertainty of 1.5x10^{-15}. The measurement uncertainty of the frequency ratio is sma…
▽ More
The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the ratio (ν_{Yb}/ν_{Sr}) to be 1.207 507 039 343 340 4(18) with a fractional uncertainty of 1.5x10^{-15}. The measurement uncertainty of the frequency ratio is smaller than that obtained from absolute frequency measurements using the International Atomic Time (TAI) link. The measured ratio agrees well with that derived from the absolute frequency measurement results obtained at NIST and JILA, Boulder, CO using their Cs-fountain clock. Our measurement enables the first international comparison of the frequency ratios of optical clocks, and we obtained a good agreement between the two measured ratios with an uncertainty smaller than the TAI link. The measured frequency ratio will be reported to the International Committee for Weights and Measures for a discussion related to the redefinition of the second.
△ Less
Submitted 23 March, 2014;
originally announced March 2014.
-
Add-drop system for Kerr bistable memory in silicon nitride microrings
Authors:
Wataru Yoshiki,
Takasumi Tanabe
Abstract:
We numerically studied the required conditions for achieving a memory operation based on Kerr bistability in the presence of the thermo-optic effect in silicon nitride microring cavity systems. By comparing a side-coupled system and an add-drop system, we found that the latter is needed to realize obtain Kerr bistable operation. In addition, we show the coupling coefficient range in which the memo…
▽ More
We numerically studied the required conditions for achieving a memory operation based on Kerr bistability in the presence of the thermo-optic effect in silicon nitride microring cavity systems. By comparing a side-coupled system and an add-drop system, we found that the latter is needed to realize obtain Kerr bistable operation. In addition, we show the coupling coefficient range in which the memory operation does not suffer from the thermo-optic effect.
△ Less
Submitted 27 August, 2013;
originally announced August 2013.
-
Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstatin Afanaciev,
Gideon Alexander,
Niloufar Alipour Tehrani,
Oscar Alonso,
Kristoffer K. Andersen,
Samir Arfaoui,
Csaba Balazs,
Tim Barklow,
Marco Battaglia,
Mathieu Benoit,
Burak Bilki,
Jean-Jacques Blaising,
Mark Boland,
Marça Boronat,
Ivanka Božović Jelisavčić,
Philip Burrows,
Maximilien Chefdeville,
Roberto Contino,
Dominik Dannheim,
Marcel Demarteau,
Marco Aurelio Diaz Gutierrez,
Angel Diéguez,
Jorge Duarte Campderros
, et al. (98 additional authors not shown)
Abstract:
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accomp…
▽ More
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.
△ Less
Submitted 30 September, 2013; v1 submitted 19 July, 2013;
originally announced July 2013.
-
Whispering gallery modes in hexagonal microcavities fabricated by crystal growth
Authors:
Hiroshi Kudo,
Ryo Suzuki,
Takasumi Tanabe
Abstract:
We investigated the whispering gallery modes of cavities with a hexagonal cross-section. We found two different modes, namely perturbed and quasi-WGMs, of which the former exhibits the higher Q when the corner radius is large. We studied the dependence of Q on the curvature radius of the polygonal cavities and found that the coupling between the two modes determines the Q of the cavity. In additio…
▽ More
We investigated the whispering gallery modes of cavities with a hexagonal cross-section. We found two different modes, namely perturbed and quasi-WGMs, of which the former exhibits the higher Q when the corner radius is large. We studied the dependence of Q on the curvature radius of the polygonal cavities and found that the coupling between the two modes determines the Q of the cavity. In addition we fabricated a cavity by employing laser heated pedestal growth and demonstrated a high Q.
△ Less
Submitted 11 April, 2013;
originally announced April 2013.
-
Fabrication of whispering gallery mode cavity using crystal growth
Authors:
Hiroshi Kudo,
Yohei Ogawa,
Takumi Kato,
Atsushi Yokoo,
Takasumi Tanabe
Abstract:
We developed a new method for fabricating crystalline whispering gallery mode cavities based on laser-heated pedestal growth. We fabricated sapphire cavities and obtained a Q factor of 16000 with a cavity whose diameter was about 240 um. We showed numerically that the cross-sectional shape of the cavity is sensitive to the cavity Q, and we controlled it successfully by changing the growth conditio…
▽ More
We developed a new method for fabricating crystalline whispering gallery mode cavities based on laser-heated pedestal growth. We fabricated sapphire cavities and obtained a Q factor of 16000 with a cavity whose diameter was about 240 um. We showed numerically that the cross-sectional shape of the cavity is sensitive to the cavity Q, and we controlled it successfully by changing the growth condition in the molten zone, without significantly degrading the crystal structure.
△ Less
Submitted 22 February, 2013;
originally announced February 2013.
-
Rigorous analysis of bistable memory in silica toroid microcavity
Authors:
Wataru Yoshiki,
Takasumi Tanabe
Abstract:
We model the nonlinear response of a silica toroid microcavity using coupled mode theory and a finite element method, and successfully obtain Kerr bistable operation that does not suffer from thermo-optic effect by optimizing the fiber-cavity coupling. Our analysis shows it is possible to demonstrate a Kerr bistable memory with a memory holding time of 500 ns at an extremely low energy consumption…
▽ More
We model the nonlinear response of a silica toroid microcavity using coupled mode theory and a finite element method, and successfully obtain Kerr bistable operation that does not suffer from thermo-optic effect by optimizing the fiber-cavity coupling. Our analysis shows it is possible to demonstrate a Kerr bistable memory with a memory holding time of 500 ns at an extremely low energy consumption.
△ Less
Submitted 6 August, 2012;
originally announced August 2012.
-
Polygonal silica toroidal microcavity for controlled optical coupling
Authors:
Takumi Kato,
Wataru Yoshiki,
Takasumi Tanabe
Abstract:
We fabricated polygonal silica toroidal microcavities to achieve stable mechanical coupling with an evanescent coupler such as a tapered fiber. The polygonal cavity was fabricated by using a combination of isotropic etching, anisotropic etching and laser reflow. It offers both high and low coupling efficiencies with the cavity mode even when the coupler is in contact with the cavity, which offers…
▽ More
We fabricated polygonal silica toroidal microcavities to achieve stable mechanical coupling with an evanescent coupler such as a tapered fiber. The polygonal cavity was fabricated by using a combination of isotropic etching, anisotropic etching and laser reflow. It offers both high and low coupling efficiencies with the cavity mode even when the coupler is in contact with the cavity, which offers the possibility of taking the device outside the laboratory. A numerical simulation showed that an octagonal silica toroidal microcavity had an optical quality factor of 8.8\times10^6.
△ Less
Submitted 25 July, 2012;
originally announced July 2012.
-
Improved jet clustering algorithm with vertex information for multi-bottom final states
Authors:
Taikan Suehara,
Tomohiko Tanabe,
Satoru Yamashita
Abstract:
In collider physics at the TeV scale, there are many important processes which involve six or more jets. The sensitivity of the physics analysis depends critically on the performance of the jet clustering algorithm. We present a full detector simulation study for the ILC of our new algorithm which makes use of secondary vertices which improves the reconstruction of b jets. This algorithm will have…
▽ More
In collider physics at the TeV scale, there are many important processes which involve six or more jets. The sensitivity of the physics analysis depends critically on the performance of the jet clustering algorithm. We present a full detector simulation study for the ILC of our new algorithm which makes use of secondary vertices which improves the reconstruction of b jets. This algorithm will have many useful applications, such as in measurements involving a light Higgs which decays predominantly into two b quarks. We focus on the measurement of the Higgs self-coupling, which has so far proven to be challenging but is one of the most important measurements at the ILC.
△ Less
Submitted 26 October, 2011;
originally announced October 2011.
-
Electro-optic adiabatic wavelength shifting and Q switching demonstrated using a p-i-n integrated photonic crystal nanocavity
Authors:
Takasumi Tanabe,
Eiichi Kuramochi,
Hideaki Taniyama,
Masaya Notomi
Abstract:
We demonstrate adiabatic wavelength shifting by electro-optic modulation using a p-i-n integrated high-Q photonic crystal nanocavity. The wavelength of the trapped light is adiabatically shifted by modulating the resonance of the cavity faster than the photon lifetime. The cavity resonance is changed by injecting electrons through a p-i-n junction to reduce the refractive index. In addition we emp…
▽ More
We demonstrate adiabatic wavelength shifting by electro-optic modulation using a p-i-n integrated high-Q photonic crystal nanocavity. The wavelength of the trapped light is adiabatically shifted by modulating the resonance of the cavity faster than the photon lifetime. The cavity resonance is changed by injecting electrons through a p-i-n junction to reduce the refractive index. In addition we employ adiabatic wavelength shifting in a demonstration of dynamic Q tuning by electro-optic modulation.
△ Less
Submitted 2 September, 2010;
originally announced September 2010.
-
All-silicon sub-Gb/s telecom detector with low dark current and high quantum efficiency on chip
Authors:
Takasumi Tanabe,
Hisashi Sumikura,
Hideaki Taniyama,
Akihiko Shinya,
Masaya Notomi
Abstract:
We demonstrate channel selective 0.1-Gb/s photo-receiver operation at telecom wavelength using a silicon high-Q photonic crystal nanocavity with a laterally integrated p-i-n diode. Due to the good crystal property of silicon the measured dark current is only 15 pA. The linear and nonlinear characteristics are investigated in detail, in which we found that the photo-current is enhanced of more th…
▽ More
We demonstrate channel selective 0.1-Gb/s photo-receiver operation at telecom wavelength using a silicon high-Q photonic crystal nanocavity with a laterally integrated p-i-n diode. Due to the good crystal property of silicon the measured dark current is only 15 pA. The linear and nonlinear characteristics are investigated in detail, in which we found that the photo-current is enhanced of more than 100,000 due to the ultrahigh-Q (>100,000). With the help of two-photon absorption, which is visible at a surprisingly low input power of 10 nW, the quantum efficiency of this device reaches about 10%.
△ Less
Submitted 17 February, 2010;
originally announced February 2010.
-
Dynamic release of trapped light from an ultrahigh-Q nanocavity via adiabatic frequency tuning
Authors:
Takasumi Tanabe,
Masaya Notomi,
Hideaki Taniyama,
Eiichi Kuramochi
Abstract:
Adiabatic frequency shifting is demonstrated by tuning an ultrahigh-Q photonic crystal nanocavity dynamically. By resolving the output temporally and spectrally, we showed that the frequency of the light in the cavity follows the cavity resonance shift and remains in a single mode throughout the process. This confirmed unambiguously that the frequency shift results from the adiabatic tuning. We…
▽ More
Adiabatic frequency shifting is demonstrated by tuning an ultrahigh-Q photonic crystal nanocavity dynamically. By resolving the output temporally and spectrally, we showed that the frequency of the light in the cavity follows the cavity resonance shift and remains in a single mode throughout the process. This confirmed unambiguously that the frequency shift results from the adiabatic tuning. We have employed this process to achieve the dynamic release of a trapped light from an ultrahigh-Q cavity and thus generate a short pulse. This approach provides a simple way of tuning Q dynamically.
△ Less
Submitted 22 December, 2008;
originally announced December 2008.
-
Preliminary Design of Muses Control System Based on RT-Corba and Java
Authors:
Toshiya Tanabe,
Toshikatsu Masuoka,
Jun-ichi Ohnishi,
Motonobu Takano,
Takeshi Katayama
Abstract:
Common Object Request Broker Architecture (CORBA) based control system has been utilized for the first phase of RIKEN-RI Beam Factory (RIBF) [1] at the developing stage. Software sharing with Jozef Stefan Institute (JSI) in Slovenia via CORBA/JavaBeans has been successfully demonstrated. Accelerator Beans (Abeans) [2] components developed in JDK1.2.2 have been ported to RIKEN's CORBA server. The…
▽ More
Common Object Request Broker Architecture (CORBA) based control system has been utilized for the first phase of RIKEN-RI Beam Factory (RIBF) [1] at the developing stage. Software sharing with Jozef Stefan Institute (JSI) in Slovenia via CORBA/JavaBeans has been successfully demonstrated. Accelerator Beans (Abeans) [2] components developed in JDK1.2.2 have been ported to RIKEN's CORBA server. The second phase of the RIBF project is named "Multi-Use Experimental Storage rings" (MUSES) project, which includes an accumulator cooler ring (ACR) and collider rings. Due to the much larger number of controlled objects and more stringent timing requirement than the first-phase project, we contemplate using recently established real-time (RT) CORBA specification [3]. Summary of our efforts to test RT-CORBA with the existing JaveBeans components and other related subjects are described in this paper.
[1] http://ribfweb1.riken.go.jp/ [2] http://kgb.ijs.si/KGB/ [3] http://www.omg.org/
△ Less
Submitted 8 November, 2001;
originally announced November 2001.