-
Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
Authors:
S. Go,
Y. Tsuzuki,
H. Yoneda,
Y. Ichikawa,
T. Ikeda,
N. Imai,
K. Imamura,
M. Niikura,
D. Nishimura,
R. Mizuno,
S. Takeda,
H. Ueno,
S. Watanabe,
T. Y. Saito,
S. Shimoura,
S. Sugawara,
A. Takamine,
T. Takahashi
Abstract:
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdT…
▽ More
To detect and track structural changes in atomic nuclei, the systematic study of nuclear levels with firm spin-parity assignments is important. While linear polarization measurements have been applied to determine the electromagnetic character of gamma-ray transitions, the applicable range is strongly limited due to the low efficiency of the detection system. The multi-layer Cadmium-Telluride (CdTe) Compton camera can be a state-of-the-art gamma-ray polarimeter for nuclear spectroscopy with the high position sensitivity and the detection efficiency. We demonstrated the capability to operate this detector as a reliable gamma-ray polarimeter by using polarized 847-keV gamma rays produced by the $^{56}\rm{Fe}({\it p},{\it p'}γ)$ reaction. By combining the experimental data and simulated calculations, the modulation curve for the gamma ray was successfully obtained. A remarkably high polarization sensitivity was achieved, compatible with a reasonable detection efficiency. Based on the obtained results, a possible future gamma-ray polarimetery is discussed.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
2-mm-Thick Large-Area CdTe Double-sided Strip Detectors for High-Resolution Spectroscopic Imaging of X-ray and Gamma-ray with Depth-Of-Interaction Sensing
Authors:
Takahiro Minami,
Miho Katsuragawa,
Shunsaku Nagasawa,
Shin'ichiro Takeda,
Shin Watanabe,
Yutaka Tsuzuki,
Tadayuki Takahashi
Abstract:
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic…
▽ More
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic imaging, for example, space observation, nuclear medicine, and non-destructive elemental analysis. This detector is thicker than the 0.75-mm-thick one previously developed by a factor of $\sim$2.7, thus providing better detection efficiency for hard X-rays and soft gamma rays. The increased thickness could potentially enhance bias-induced polarization if we do not apply sufficient bias and if we do not operate at a low temperature, but the polarization is not evident in our detector when a high voltage of 500 V is applied to the CdTe diode and the temperature is maintained at -20 $^\circ$C during one-day experiments. The ''Depth Of Interaction'' (DOI) dependence due to the CdTe diode's poor carrier-transport property is also more significant, resulting in much DOI information while complicated detector responses such as charge sharings or low-energy tails that exacerbate the loss in the energy resolution.
In this paper, we developed 2-mm-thick CdTe-DSDs, studied their response, and evaluated their energy resolution, spatial resolution, and uniformity. We also constructed a theoretical model to understand the detector response theoretically, resulting in reconstructing the DOI with an accuracy of 100 um while estimating the carrier-transport property. We realized the detector that has high energy resolution and high 3D spatial resolution with a uniform large imaging area.
△ Less
Submitted 17 December, 2023; v1 submitted 13 December, 2023;
originally announced December 2023.
-
Ultrafast electron-electron scattering in metallic phase of 2H-NbSe$_2$ probed by high harmonic generation
Authors:
K. S. Takeda,
K. Uchida,
K. Nagai,
S. Kusaba,
K. Tanaka
Abstract:
Electron-electron scattering on the order of a few to tens of femtoseconds plays a crucial role in the ultrafast electron dynamics of conventional metals. When mid-infrared light is used for driving and the period of light field is comparable to the scattering time in metals, unique light-driven states and nonlinear optical responses associated with the scattering process are expected to occur. He…
▽ More
Electron-electron scattering on the order of a few to tens of femtoseconds plays a crucial role in the ultrafast electron dynamics of conventional metals. When mid-infrared light is used for driving and the period of light field is comparable to the scattering time in metals, unique light-driven states and nonlinear optical responses associated with the scattering process are expected to occur. Here, we use high-harmonics spectroscopy to investigate the effect of electron-electron scattering on the electron dynamics in thin film 2H-NbSe$_2$ driven by a mid-infrared field. We observed odd-order high harmonics up to 9th order as well as a broadband emission from hot electrons in the energy range from 1.5 to 4.0 eV. The electron-electron scattering time in NbSe$_2$ was estimated from the broadband emission to be almost the same as the period of the mid-infrared light field. A comparison between experimental results and a numerical calculation reveals that a kind of resonance between scattering and driving enhances the non-perturbative behavior of high harmonics in metals, causing a highly non-equilibrium electronic state corresponding to several thousand Kelvin.
△ Less
Submitted 12 February, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Time-Domain Universal Linear-Optical Operations for Universal Quantum Information Processing
Authors:
Kazuma Yonezu,
Yutaro Enomoto,
Takato Yoshida,
Shuntaro Takeda
Abstract:
We demonstrate universal and programmable three-mode linear optical operations in the time domain by realizing a scalable dual-loop optical circuit suitable for universal quantum information processing (QIP). The programmability, validity, and deterministic operation of our circuit are demonstrated by performing nine different three-mode operations on squeezed-state pulses, fully characterizing th…
▽ More
We demonstrate universal and programmable three-mode linear optical operations in the time domain by realizing a scalable dual-loop optical circuit suitable for universal quantum information processing (QIP). The programmability, validity, and deterministic operation of our circuit are demonstrated by performing nine different three-mode operations on squeezed-state pulses, fully characterizing the outputs with variable measurements, and confirming their entanglement. Our circuit can be scaled up just by making the outer loop longer and also extended to universal quantum computers by incorporating feedforward systems. Thus, our work paves the way to large-scale universal optical QIP.
△ Less
Submitted 31 July, 2023; v1 submitted 28 October, 2022;
originally announced October 2022.
-
Programmable time-multiplexed squeezed light source
Authors:
Hiroko Tomoda,
Takato Yoshida,
Takahiro Kashiwazaki,
Takeshi Umeki,
Yutaro Enomoto,
Shuntaro Takeda
Abstract:
One of the leading approaches to large-scale quantum information processing (QIP) is the continuous-variable (CV) scheme based on time multiplexing (TM). As a fundamental building block for this approach, quantum light sources to sequentially produce time-multiplexed squeezed-light pulses are required; however, conventional CV TM experiments have used fixed light sources that can only output the s…
▽ More
One of the leading approaches to large-scale quantum information processing (QIP) is the continuous-variable (CV) scheme based on time multiplexing (TM). As a fundamental building block for this approach, quantum light sources to sequentially produce time-multiplexed squeezed-light pulses are required; however, conventional CV TM experiments have used fixed light sources that can only output the squeezed pulses with the same squeezing levels and phases. We here demonstrate a programmable time-multiplexed squeezed light source that can generate sequential squeezed pulses with various squeezing levels and phases at a time interval below 100 ns. The generation pattern can be arbitrarily chosen by software without changing its hardware configuration. This is enabled by using a waveguide optical parametric amplifier and modulating its continuous pump light. Our light source will implement various large-scale CV QIP tasks.
△ Less
Submitted 9 March, 2023; v1 submitted 20 September, 2022;
originally announced September 2022.
-
Continuous-variable quantum approximate optimization on a programmable photonic quantum processor
Authors:
Yutaro Enomoto,
Keitaro Anai,
Kenta Udagawa,
Shuntaro Takeda
Abstract:
Variational quantum algorithms (VQAs) provide a promising approach to achieving quantum advantage for practical problems on near-term noisy intermediate-scale quantum (NISQ) devices. Thus far, most studies on VQAs have focused on qubit-based systems, but the power of VQAs can be potentially boosted by exploiting infinite-dimensional continuous-variable (CV) systems. Here, we implement the CV versi…
▽ More
Variational quantum algorithms (VQAs) provide a promising approach to achieving quantum advantage for practical problems on near-term noisy intermediate-scale quantum (NISQ) devices. Thus far, most studies on VQAs have focused on qubit-based systems, but the power of VQAs can be potentially boosted by exploiting infinite-dimensional continuous-variable (CV) systems. Here, we implement the CV version of one VQA, a quantum approximate optimization algorithm by developing an automated collaborative computing system between a programmable photonic quantum computer and a classical computer. We experimentally demonstrate that this algorithm solves the minimization problem of simple continuous functions by implementing the quantum version of gradient descent to localize an initially broadly-distributed wavefunction to the minimum. This method allows the execution of a practical CV quantum algorithm on a physical platform. Our work can be extended to the minimization of more general functions, providing an alternative to achieve the quantum advantage in practical problems.
△ Less
Submitted 5 October, 2023; v1 submitted 14 June, 2022;
originally announced June 2022.
-
Self-propulsion of a light-powered microscopic crystalline flapper in water
Authors:
Kazuma Obara,
Yoshiyuki Kageyama,
Sadamu Takeda
Abstract:
A key goal in developing molecular microrobots that mimic real-world animal dynamic behavior is to understand better the self-continuous progressive motion resulting from collective molecular transformation. This study reports, for the first time, the experimental realization of directional swimming of a microcrystal that exhibits self-continuous reciprocating motion in a two-dimensional water tan…
▽ More
A key goal in developing molecular microrobots that mimic real-world animal dynamic behavior is to understand better the self-continuous progressive motion resulting from collective molecular transformation. This study reports, for the first time, the experimental realization of directional swimming of a microcrystal that exhibits self-continuous reciprocating motion in a two-dimensional water tank. Although the reciprocal flip motion of the crystals was like that of a fish wagging its tail fin, many of the crystals swam in the opposite direction to which a fish would swim. Here we explore the directionality generation mechanism and physical features of the swimming behavior by constructing a mathematical model for the crystalline flapper. The results show that a tiny crystal with a less-deformable part in its flip fin exhibits a pull-type stroke swimming, while a crystal with a fin that uniformly deforms exhibits push-type kicking motion.
△ Less
Submitted 6 November, 2021; v1 submitted 31 August, 2021;
originally announced August 2021.
-
Tomographic Imaging by a Si/CdTe Compton Camera for In-111 and I-131 Radionuclides
Authors:
Goro Yabu,
Hiroki Yoneda,
Tadashi Orita,
Shin'ichiro Takeda,
Pietro Caradonna,
Tadayuki Takahashi,
Shin Watanabe,
Fumiki Moriyama
Abstract:
Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its high angular and high energy resolutions is an especially promising detector to extend the energy coverage for imaging to the range that covers gamma-ray emitt…
▽ More
Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its high angular and high energy resolutions is an especially promising detector to extend the energy coverage for imaging to the range that covers gamma-ray emitted from these radionuclides. Here, we take the first steps towards short-distance imaging by conducting experiments using three-dimensional phantoms composed of multiple sphere-like solutions of $^{111}$In and $^{131}$I with a diameter of 2.7 mm, placed at a distance of 41 mm. Using simple back-projection methods, the positions of the sources are reproduced with a spatial resolution of 11.5 mm and 9.0 mm (FWHM) for $^{111}$In and $^{131}$I, respectively. We found that a LM-MLEM method gives a better resolution of 4.0 mm and 2.7 mm (FWHM). We resolve source positions of a tetrahedron structure with a source-to-source separation of 28 mm. These findings demonstrate that Compton Cameras have the potential of close-distance imaging of radioisotopes distributions in the energy range below 400 keV.
△ Less
Submitted 19 August, 2021;
originally announced August 2021.
-
Triad second renormalization group
Authors:
Daisuke Kadoh,
Hideaki Oba,
Shinji Takeda
Abstract:
We propose a second renormalization group (SRG) in the triad representation of tensor networks. The SRG method improves two parts of the triad tensor renormalization group, which are the decomposition of intermediate tensors and the preparation of isometries, taking the influence of environment tensors into account. Every fundamental tensor including environment tensor is given as a rank-3 tensor,…
▽ More
We propose a second renormalization group (SRG) in the triad representation of tensor networks. The SRG method improves two parts of the triad tensor renormalization group, which are the decomposition of intermediate tensors and the preparation of isometries, taking the influence of environment tensors into account. Every fundamental tensor including environment tensor is given as a rank-3 tensor, and the computational cost of the proposed algorithm scales with ${\cal O}(χ^5)$ employing the randomized SVD where $χ$ is the bond dimension of tensors. We test this method in the classical Ising model on the two dimensional square lattice, and find that numerical results are obtained in good accuracy for a fixed computational time.
△ Less
Submitted 13 February, 2022; v1 submitted 19 July, 2021;
originally announced July 2021.
-
Development of a Low-noise Front-end ASIC for CdTe Detectors
Authors:
Tenyo Kawamura,
Tadashi Orita,
Shin'ichiro Takeda,
Shin Watanabe,
Hirokazu Ikeda,
Tadayuki Takahashi
Abstract:
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured withou…
▽ More
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured without connecting the ASIC to any detectors. From the spectroscopy measurements using a CdTe single-sided strip detector, the energy resolution of 1.12 keV (FWHM) is obtained at 13.9 keV, and photons within the energy from 6.4 keV to 122.1 keV are detected. Based on the experimental results, we propose a new low-noise readout architecture making use of a slew-rate limited mode at the shaper followed by a peak detector circuit.
△ Less
Submitted 31 August, 2020;
originally announced September 2020.
-
Imaging and Spectral Performance of a 60 μm Pitch CdTe Double-Sided Strip Detector
Authors:
Kento Furukawa,
Shunsaku Nagasawa,
Lindsay Glesener,
Miho Katsuragawa,
Shin'ichiro Takeda,
Shin Watanabe,
Tadayuki Takahashi
Abstract:
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of…
▽ More
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of the depth of photon interaction and charge sharing effects are of importance in order to provide good spectroscopic and imaging performance. We study the tail structure observed in the spectra caused by charge trapping and develop a new method to reconstruct the spectra based on induced charge information from both anode and cathode strips. By applying this method, energy resolutions (FWHM) of 0.76 keV and 1.0 keV can be obtained at photon energies of 14 keV and 60 keV, respectively, if the energy difference between the anode and cathode is within 1 keV. Furthermore, the tail component at 60 keV is reduced, and the energy resolution of the 60 keV peak is improved from 2.4 keV to 1.5 keV (FWHM) if the energy difference is greater than 1 keV. In order to study the imaging performance, we constructed a simple imaging system using a 5 mm thick tungsten plate that has a pinhole with a diameter of 100 um. We utilize a Ba-133 radioisotope of 1 mm in diameter as a target source in combination with a 100 um slit made from 0.5 mm thickness tungsten. We imaged the Ba-133 source behind the 100 um slit using a 30 keV peak, with a 100 um pinhole placed at the center of the source-detector distance. By applying a charge sharing correction between strips, we have succeeded in obtaining a position resolution better than the strip pitch of 60 um.
△ Less
Submitted 10 June, 2020;
originally announced June 2020.
-
Molecular Inverse-Design Platform for Material Industries
Authors:
Seiji Takeda,
Toshiyuki Hama,
Hsiang-Han Hsu,
Victoria A. Piunova,
Dmitry Zubarev,
Daniel P. Sanders,
Jed W. Pitera,
Makoto Kogoh,
Takumi Hongo,
Yenwei Cheng,
Wolf Bocanett,
Hideaki Nakashika,
Akihiro Fujita,
Yuta Tsuchiya,
Katsuhiko Hino,
Kentaro Yano,
Shuichi Hirose,
Hiroki Toda,
Yasumitsu Orii,
Daiju Nakano
Abstract:
The discovery of new materials has been the essential force which brings a discontinuous improvement to industrial products' performance. However, the extra-vast combinatorial design space of material structures exceeds human experts' capability to explore all, thereby hampering material development. In this paper, we present a material industry-oriented web platform of an AI-driven molecular inve…
▽ More
The discovery of new materials has been the essential force which brings a discontinuous improvement to industrial products' performance. However, the extra-vast combinatorial design space of material structures exceeds human experts' capability to explore all, thereby hampering material development. In this paper, we present a material industry-oriented web platform of an AI-driven molecular inverse-design system, which automatically designs brand new molecular structures rapidly and diversely. Different from existing inverse-design solutions, in this system, the combination of substructure-based feature encoding and molecular graph generation algorithms allows a user to gain high-speed, interpretable, and customizable design process. Also, a hierarchical data structure and user-oriented UI provide a flexible and intuitive workflow. The system is deployed on IBM's and our client's cloud servers and has been used by 5 partner companies. To illustrate actual industrial use cases, we exhibit inverse-design of sugar and dye molecules, that were carried out by experimental chemists in those client companies. Compared to general human chemist's standard performance, the molecular design speed was accelerated more than 10 times, and greatly increased variety was observed in the inverse-designed molecules without loss of chemical realism.
△ Less
Submitted 16 May, 2020; v1 submitted 23 April, 2020;
originally announced April 2020.
-
Probing entanglement in Compton interactions
Authors:
Peter Caradonna,
David Reutens,
Tadayuki Takahashi,
Shin'ichiro Takeda,
Viktor Vegh
Abstract:
This theoretical research aims to examine areas of the Compton cross section of entangled annihilation photons for the purpose of testing for possible break down of theory, which could have consequences for predicted optimal capabilities of Compton PET systems.We provide maps of the cross section for entangled annihilation photons for experimental verification.We introduce a strategy to derive cro…
▽ More
This theoretical research aims to examine areas of the Compton cross section of entangled annihilation photons for the purpose of testing for possible break down of theory, which could have consequences for predicted optimal capabilities of Compton PET systems.We provide maps of the cross section for entangled annihilation photons for experimental verification.We introduce a strategy to derive cross sections in a relatively straight forward manner for the Compton scattering of a hypothetical separable, mixed and entangled states. To understand the effect that entanglement has on the cross section for annihilation photons, we derive the cross section so that it is expressed in terms of the cross section of a hypothetical separable state and of a hypothetical forbidden maximally entangled state.We find lobe-like structures in the cross section which are regions where entanglement has the greatest effect.We also find that mixed states do not reproduce the cross section for annihilation photons, contrary to a recent investigation which reported otherwise.We review the motivation and method of the most precise Compton scattering experiment for annihilation photons, in order to resolve conflicting reports regarding the extent to which the cross section itself has been experimentally verified.
△ Less
Submitted 12 October, 2019;
originally announced October 2019.
-
Ultrafast creation of overlapping Rydberg electrons in an atomic BEC and Mott-insulator lattice
Authors:
Michiteru Mizoguchi,
Yichi Zhang,
Masaya Kunimi,
Akira Tanaka,
Shuntaro Takeda,
Nobuyuki Takei,
Vineet Bharti,
Kuniaki Koyasu,
Tetsuo Kishimoto,
Dieter Jaksch,
Alexander Glaetzle,
Martin Kiffner,
Guido Masella,
Guido Pupillo,
Matthias Weidemüller,
Kenji Ohmori
Abstract:
An array of ultracold atoms in an optical lattice (Mott insulator) excited to a state where single electron wave-functions spatially overlap would represent a new and ideal platform to simulate exotic electronic many-body phenomena in the condensed phase. However, this highly excited non-equilibrium system is expected to be so short-lived that it has eluded observation so far. Here, we demonstrate…
▽ More
An array of ultracold atoms in an optical lattice (Mott insulator) excited to a state where single electron wave-functions spatially overlap would represent a new and ideal platform to simulate exotic electronic many-body phenomena in the condensed phase. However, this highly excited non-equilibrium system is expected to be so short-lived that it has eluded observation so far. Here, we demonstrate the first step toward its realization by exciting high-lying electronic (Rydberg) states of the atomic Mott insulator with a coherent ultrashort laser pulse. Beyond a threshold principal quantum number where Rydberg orbitals of neighboring lattice sites overlap with each other, the atoms efficiently undergo spontaneous Penning ionization resulting in a drastic change of ion-counting statistics, sharp increase of avalanche ionization and the formation of an ultracold plasma. These observations signal the actual creation of exotic electronic states with overlapping wave functions, which is further confirmed by a significant difference in ionization dynamics between a Bose-Einstein condensate and a Mott insulator.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
Tensor Renormalization Group Algorithms with a Projective Truncation Method
Authors:
Yoshifumi Nakamura,
Hideaki Oba,
Shinji Takeda
Abstract:
We apply the projective truncation technique to the tensor renormalization group (TRG) algorithm in order to reduce the computational cost from $O(χ^6)$ to $O(χ^5)$, where $χ$ is the bond dimension, and propose three kinds of algorithms for demonstration. On the other hand, the technique causes a systematic error due to the incompleteness of a projector composed of isometries, and in addition requ…
▽ More
We apply the projective truncation technique to the tensor renormalization group (TRG) algorithm in order to reduce the computational cost from $O(χ^6)$ to $O(χ^5)$, where $χ$ is the bond dimension, and propose three kinds of algorithms for demonstration. On the other hand, the technique causes a systematic error due to the incompleteness of a projector composed of isometries, and in addition requires iteration steps to determine the isometries. Nevertheless, we find that the accuracy of the free energy for the Ising model on a square lattice is recovered to the level of TRG with a few iteration steps even at the critical temperature for $χ$ = 32, 48, and 64.
△ Less
Submitted 1 April, 2019; v1 submitted 21 September, 2018;
originally announced September 2018.
-
Imaging and spectral performance of CdTe double-sided strip detectors for the Hard X-ray Imager onboard ASTRO-H
Authors:
Kouichi Hagino,
Hirokazu Odaka,
Goro Sato,
Shin Watanabe,
Shin'ichiro Takeda,
Motohide Kokubun,
Taro Fukuyama,
Shinya Saito,
Tamotsu Sato,
Yuto Ichinohe,
Tadayuki Takahashi,
Toshio Nakano,
Kazuhiro Nakazawa,
Kazuo Makishima,
Hiroyasu Tajima,
Takaaki Tanaka,
Kazunori Ishibashi,
Takuya Miyazawa,
Michito Sakai,
Karin Sakanobe,
Hiroyoshi Kato,
Shunya Takizawa,
Kentaro Uesugi
Abstract:
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well…
▽ More
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction, a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron radiation facility. From these experiments, the depth structure of the electric field was determined as well as properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.
△ Less
Submitted 20 May, 2018;
originally announced May 2018.
-
A compact imaging system with a CdTe double-sided strip detector for non-destructive analysis using negative muonic X-rays
Authors:
Miho Katsuragawa,
Motonobu Tampo,
Koji Hamada,
Atsushi Harayama,
Yasuhiro Miyake,
Sayuri Oshita,
Goro Sato,
Tadayuki Takahashi,
Shin'ichiro Takeda,
Shin Watanabe,
Goro Yabu
Abstract:
A CdTe double-sided strip detector (CdTe-DSD) is an ideal device for imaging and spectroscopic measure- ments in the hard X-ray range above 10 keV. Recent development enables us to realize an imager with a detection area of ~10 cm${^2}$. An energy resolution of 1-2 keV (FWHM) and a position resolution of a few hundred μm are available from the detector. This type of imager has been long awaited fo…
▽ More
A CdTe double-sided strip detector (CdTe-DSD) is an ideal device for imaging and spectroscopic measure- ments in the hard X-ray range above 10 keV. Recent development enables us to realize an imager with a detection area of ~10 cm${^2}$. An energy resolution of 1-2 keV (FWHM) and a position resolution of a few hundred μm are available from the detector. This type of imager has been long awaited for non-destructive elemental analysis, especially by using negative muons, because energies of characteristic X-rays from muonic atoms are about 200 time higher than those from normal atoms. With the method that uses negative muons, hard X-ray information gives the spatial distribution of elements in samples at a certain depth defined by the initial momentum of the muon beam. In order to study three-dimensional imaging capability of the method, we have developed a compact imaging system based on CdTe-DSD and a φ3 mm pinhole collimator as the first prototype. We conducted experiments with samples which consist of layers of Al, BN and LiF irradiated by negative muon beams in MUSE/J-PARC and successfully reconstruct hard X-ray images of muonic X-rays from B, N and F at various depths.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
High-speed X-ray imaging spectroscopy system with Zynq SoC for solar observations
Authors:
Shin-nosuke Ishikawa,
Tadayuki Takahashi,
Shin Watanabe,
Noriyuki Narukage,
Satoshi Miyazaki,
Tadashi Orita,
Shin'ichiro Takeda,
Masaharu Nomahi,
Iwao Fujishiro,
Fumio Hodoshima
Abstract:
We have developed a system combining a back-illuminated Complementary-Metal-Oxide-Semiconductor (CMOS) imaging sensor and Xilinx Zynq System-on-Chip (SoC) device for a soft X-ray (0.5-10 keV) imaging spectroscopy observation of the Sun to investigate the dynamics of the solar corona. Because typical timescales of energy release phenomena in the corona span a few minutes at most, we aim to obtain t…
▽ More
We have developed a system combining a back-illuminated Complementary-Metal-Oxide-Semiconductor (CMOS) imaging sensor and Xilinx Zynq System-on-Chip (SoC) device for a soft X-ray (0.5-10 keV) imaging spectroscopy observation of the Sun to investigate the dynamics of the solar corona. Because typical timescales of energy release phenomena in the corona span a few minutes at most, we aim to obtain the corresponding energy spectra and derive the physical parameters, i.e., temperature and emission measure, every few tens of seconds or less for future solar X-ray observations. An X-ray photon-counting technique, with a frame rate of a few hundred frames per second or more, can achieve such results. We used the Zynq SoC device to achieve the requirements. Zynq contains an ARM processor core, which is also known as the Processing System (PS) part, and a Programmable Logic (PL) part in a single chip. We use the PL and PS to control the sensor and seamless recording of data to a storage system, respectively. We aim to use the system for the third flight of the Focusing Optics Solar X-ray Imager (FOXSI-3) sounding rocket experiment for the first photon-counting X-ray imaging and spectroscopy of the Sun.
△ Less
Submitted 12 November, 2017;
originally announced November 2017.
-
Time-domain Ramsey interferometry with interacting Rydberg atoms
Authors:
Christian Sommer,
Guido Pupillo,
Nobuyuki Takei,
Shuntaro Takeda,
Akira Tanaka,
Kenji Ohmori,
Claudiu Genes
Abstract:
We theoretically investigate the dynamics of a gas of strongly interacting Rydberg atoms subject to a time-domain Ramsey interferometry protocol. The many-body dynamics is governed by an Ising-type Hamiltonian with long range interactions of tunable strength. We analyze and model the contrast degradation and phase accumulation of the Ramsey signal and identify scaling laws for varying interrogatio…
▽ More
We theoretically investigate the dynamics of a gas of strongly interacting Rydberg atoms subject to a time-domain Ramsey interferometry protocol. The many-body dynamics is governed by an Ising-type Hamiltonian with long range interactions of tunable strength. We analyze and model the contrast degradation and phase accumulation of the Ramsey signal and identify scaling laws for varying interrogation times, ensemble densities, and ensemble dimensionalities.
△ Less
Submitted 15 November, 2016; v1 submitted 8 April, 2016;
originally announced April 2016.
-
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
Authors:
Shin Watanabe,
Hiroyasu Tajima,
Yasushi Fukazawa,
Yuto Ichinohe,
Shin'ichiro Takeda,
Teruaki Enoto,
Taro Fukuyama,
Shunya Furui,
Kei Genba,
Kouichi Hagino,
Astushi Harayama,
Yoshikatsu Kuroda,
Daisuke Matsuura,
Ryo Nakamura,
Kazuhiro Nakazawa,
Hirofumi Noda,
Hirokazu Odaka,
Masayuki Ohta,
Mitsunobu Onishi,
Shinya Saito,
Goro Sato,
Tamotsu Sato,
Tadayuki Takahashi,
Takaaki Tanaka,
Atsushi Togo
, et al. (1 additional authors not shown)
Abstract:
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector sys…
▽ More
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.