-
Broadband, Dead-Time-Free Spectrometer Using RFSoC for WISP Dark Matter Searches
Authors:
Hiroki Takeuchi,
Junya Suzuki,
Shunsuke Adachi,
Osamu Tajima
Abstract:
Ultra-light dark matter candidates, such as axions and dark photons, particularly within the mass range of $μ$eV to meV, have garnered significant research interest. However, the effectiveness of existing experiments is often hindered by the narrow bandwidths of conventional spectrometers. This study presents a novel spectrometer solution based on a RFSoC, which integrates a high-speed data conver…
▽ More
Ultra-light dark matter candidates, such as axions and dark photons, particularly within the mass range of $μ$eV to meV, have garnered significant research interest. However, the effectiveness of existing experiments is often hindered by the narrow bandwidths of conventional spectrometers. This study presents a novel spectrometer solution based on a RFSoC, which integrates a high-speed data converter, field programmable gate array (FPGA), and a CPU within a single chip. The spectrometer's programmable logic implements an optimized fast Fourier transform (FFT) that minimizes memory usage, enabling an instantaneous bandwidth of 4 GHz with a frequency resolution of 16 kHz. This configuration achieves more than 99.6% time efficiency, effectively doubling search efficiency, compared with traditional approaches. This paper provides a comprehensive description of the hardware architecture, FPGA firmware, and software implementation, with a focus on the resource-efficient pipelined FFT algorithm. Performance validation results are also presented, demonstrating the accuracy and time efficiency of the developed spectrometer, highlighting its potential for advancing dark matter search.
△ Less
Submitted 21 January, 2025;
originally announced January 2025.
-
Characterization of two-level system noise for microwave kinetic inductance detector comprising niobium film on silicon substrate
Authors:
Yoshinori Sueno,
Shunsuke Honda,
Hiroki Kutsuma,
Satoru Mima,
Chiko Otani,
Shugo Oguri,
Junya Suzuki,
Osamu Tajima
Abstract:
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is important to establish a method to suppress the two-level system (TLS) noise that is caused by the electric fluctuations between the two energy states at the surface o…
▽ More
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is important to establish a method to suppress the two-level system (TLS) noise that is caused by the electric fluctuations between the two energy states at the surface of the substrate. The electric field density can be decreased by expanding the strip width (S) and gap width from the ground plane (W) in the MKID circuit, allowing the suppression of TLS noise. However, this effect has not yet been confirmed for MKIDs made with niobium films on silicon substrates. In this study, we demonstrate its effectiveness for such MKIDs. We expanded the dimension of the circuit from (S, W) = (3.00 $μ$m, 4.00 $μ$m) to (S, W) = (5.00 $μ$m, 23.7 $μ$m), and achieved an increased suppression of 5.5 dB in TLS noise.
△ Less
Submitted 26 January, 2022; v1 submitted 30 September, 2021;
originally announced October 2021.
-
Search for hidden-photon cold dark matter using a K-band cryogenic receiver
Authors:
Nozomu Tomita,
Shugo Oguri,
Yoshizumi Inoue,
Makoto Minowa,
Taketo Nagasaki,
Jun'ya Suzuki,
Osamu Tajima
Abstract:
We search for hidden-photon cold dark matter (HP-CDM) using a spectroscopic system in a K-band frequency range. Our system comprises a planar metal plate and cryogenic receiver. This is the first time a cryogenic receiver has been used in the search for HP-CDM. Such use helps reduce thermal noise. We recorded data for 9.3 hours using an effective aperture area of 14.8 cm$^2$. No signal was found i…
▽ More
We search for hidden-photon cold dark matter (HP-CDM) using a spectroscopic system in a K-band frequency range. Our system comprises a planar metal plate and cryogenic receiver. This is the first time a cryogenic receiver has been used in the search for HP-CDM. Such use helps reduce thermal noise. We recorded data for 9.3 hours using an effective aperture area of 14.8 cm$^2$. No signal was found in the data. We set upper limits for the parameter of mixing between the photon and HP-CDM in the mass range from 115.79 to 115.85 $μ$eV, $χ< 1.8$-$4.3 \times 10^{-10}$, at a 95% confidence level. This is the most stringent upper limit obtained to date in the considered mass range.
△ Less
Submitted 8 September, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
A method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves
Authors:
Hiroki Kutsuma,
Yoshinori Sueno,
Makoto Hattori,
Satoru Mima,
Shugo Oguri,
Chiko Otani,
Junya Suzuki,
Osamu Tajima
Abstract:
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied powe…
▽ More
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited in the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we estimate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
Production Method of Millimeter-Wave Absorber with 3D-Printed Mold
Authors:
S. Adachi,
M. Hattori,
F. Kanno,
K. Kiuchi,
T. Okada,
O. Tajima
Abstract:
We established a production method of a good millimeter-wave absorber by using a 3D-printed mold. The mold has a periodic pyramid shape, and an absorptive material is filled into the mold. This shape reduces the surface reflection. The 3D-printed mold is made from a transparent material in the millimeter-wave range. Therefore, unmolding is not necessary. A significant benefit of this production me…
▽ More
We established a production method of a good millimeter-wave absorber by using a 3D-printed mold. The mold has a periodic pyramid shape, and an absorptive material is filled into the mold. This shape reduces the surface reflection. The 3D-printed mold is made from a transparent material in the millimeter-wave range. Therefore, unmolding is not necessary. A significant benefit of this production method is easy prototyping with various shapes and various absorptive materials. We produced a test model and used a two-component epoxy encapsulant as the absorptive material. The test model achieved a low reflectance: $\sim 1\%$ at 100 GHz. The absorber is sometimes maintained at a low temperature condition for cases in which superconducting detectors are used. Therefore, cryogenic performance is required in terms of a mechanical strength for the thermal cycles, an adhesive strength, and a sufficient thermal conductivity. We confirmed the test-model strength by immersing the model into a liquid-nitrogen bath.
△ Less
Submitted 2 January, 2020;
originally announced January 2020.
-
A measurement method for responsivity of microwave kinetic inductance detector by changing power of readout microwaves
Authors:
Hiroki Kutsuma,
Makoto Hattori,
Ryo Koyano,
Satoru Mima,
Shugo Oguri,
Chiko Otani,
Tohru Taino,
Osamu Tajima
Abstract:
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of cutting-edge superconducting detector. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the…
▽ More
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of cutting-edge superconducting detector. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase response as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285mK. We also confirm consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.
△ Less
Submitted 8 July, 2019;
originally announced July 2019.
-
Measurements of tropospheric ice clouds with a ground-based CMB polarization experiment, POLARBEAR
Authors:
Satoru Takakura,
Mario A. O. Aguilar-Faúndez,
Yoshiki Akiba,
Kam Arnold,
Carlo Baccigalupi,
Darcy Barron,
Dominic Beck,
Federico Bianchini,
David Boettger,
Julian Borrill,
Kolen Cheung,
Yuji Chinone,
Tucker Elleflot,
Josquin Errard,
Giulio Fabbian,
Chang Feng,
Neil Goeckner-Wald,
Takaho Hamada,
Masaya Hasegawa,
Masashi Hazumi,
Logan Howe,
Daisuke Kaneko,
Nobuhiko Katayama,
Brian Keating,
Reijo Keskitalo
, et al. (23 additional authors not shown)
Abstract:
The polarization of the atmosphere has been a long-standing concern for ground-based experiments targeting cosmic microwave background (CMB) polarization. Ice crystals in upper tropospheric clouds scatter thermal radiation from the ground and produce a horizontally-polarized signal. We report the detailed analysis of the cloud signal using a ground-based CMB experiment, POLARBEAR, located at the A…
▽ More
The polarization of the atmosphere has been a long-standing concern for ground-based experiments targeting cosmic microwave background (CMB) polarization. Ice crystals in upper tropospheric clouds scatter thermal radiation from the ground and produce a horizontally-polarized signal. We report the detailed analysis of the cloud signal using a ground-based CMB experiment, POLARBEAR, located at the Atacama desert in Chile and observing at 150 GHz. We observe horizontally-polarized temporal increases of low-frequency fluctuations ("polarized bursts," hereafter) of $\lesssim$0.1 K when clouds appear in a webcam monitoring the telescope and the sky. The hypothesis of no correlation between polarized bursts and clouds is rejected with $>$24$σ$ statistical significance using three years of data. We consider many other possibilities including instrumental and environmental effects, and find no other reasons other than clouds that can explain the data better. We also discuss the impact of the cloud polarization on future ground-based CMB polarization experiments.
△ Less
Submitted 18 September, 2018;
originally announced September 2018.
-
Performance of a continuously rotating half-wave plate on the POLARBEAR telescope
Authors:
Satoru Takakura,
Mario Aguilar,
Yoshiki Akiba,
Kam Arnold,
Carlo Baccigalupi,
Darcy Barron,
Shawn Beckman,
David Boettger,
Julian Borrill,
Scott Chapman,
Yuji Chinone,
Ari Cukierman,
Anne Ducout,
Tucker Elleflot,
Josquin Errard,
Giulio Fabbian,
Takuro Fujino,
Nicholas Galitzki,
Neil Goeckner-Wald,
Nils W. Halverson,
Masaya Hasegawa,
Kaori Hattori,
Masashi Hazumi,
Charles Hill,
Logan Howe
, et al. (28 additional authors not shown)
Abstract:
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector…
▽ More
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $\sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{\rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{\rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($\ell \sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.
△ Less
Submitted 27 May, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Sub-Kelvin refrigeration with dry-coolers on a rotating system
Authors:
S. Oguri,
H. Ishitsuka,
J. Choi,
M. Kawai,
O. Tajima
Abstract:
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint connectors for electricity and helium gas circulation enable the coolers to be operated and maintained with ease. We performed cool-down tests under a condition of conti…
▽ More
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint connectors for electricity and helium gas circulation enable the coolers to be operated and maintained with ease. We performed cool-down tests under a condition of continuous rotation at 20 rpm. We obtained a temperature of 0.23 K with a holding time of more than 24 hours, thus complying with catalog specifications. We monitored the system's performance for four weeks; two weeks with and without rotation. A few-percent difference in conditions was observed between these two states. Most applications can tolerate such a slight difference. The technology developed is useful for various scientific applications requiring sub-Kelvin conditions on rotating platforms.
△ Less
Submitted 18 July, 2014; v1 submitted 29 May, 2014;
originally announced May 2014.
-
Laboratory Studies on the Removal of Radon-Born Lead from KamLAND's Organic Liquid Scintillator
Authors:
G. Keefer,
C. Grant,
A. Piepke,
T. Ebihara,
H. Ikeda,
Y. Kishimoto,
Y. Kibe,
Y. Koseki,
M. Ogawa,
J. Shirai,
S. Takeuchi,
C. Mauger,
C. Zhang,
G. Schweitzer,
B. E. Berger,
S. Dazeley,
M. P. Decowski,
J. A. Detwiler,
Z. Djurcic,
D. A. Dwyer,
Y. Efremenko,
S. Enomoto,
S. J. Freedman,
B. K. Fujikawa,
K. Furuno
, et al. (43 additional authors not shown)
Abstract:
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was ide…
▽ More
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.
△ Less
Submitted 3 December, 2013;
originally announced December 2013.
-
Radio-transparent multi-layer insulation for radiowave receivers
Authors:
J. Choi,
H. Ishitsuka,
S. Mima,
S. Oguri,
K. Takahashi,
O. Tajima
Abstract:
In the field of radiowave detection, enlarging the receiver aperture to enhance the amount of light detected is essential for greater scientific achievements. One challenge in using radio transmittable apertures is keeping the detectors cool. This is because transparency to thermal radiation above the radio frequency range increases the thermal load. A technology that maintains cold conditions whi…
▽ More
In the field of radiowave detection, enlarging the receiver aperture to enhance the amount of light detected is essential for greater scientific achievements. One challenge in using radio transmittable apertures is keeping the detectors cool. This is because transparency to thermal radiation above the radio frequency range increases the thermal load. A technology that maintains cold conditions while allowing larger apertures has been long-awaited. We propose radio-transparent multi-layer insulation (RT-MLI), composed from a set of stacked insulating layers. The insulator is transparent to radio frequencies, but not transparent to infrared radiation. The basic idea for cooling is similar to conventional multi-layer insulation. It leads to a reduction in thermal radiation while maintaining a uniform surface temperature. The advantage of this technique over other filter types is that no thermal links are required. As insulator material, we used foamed polystyrene; its low index of refraction makes an anti-reflection coating unnecessary. We measured the basic performance of RT-MLI to confirm that thermal loads are lowered with more layers. We also confirmed that our RT-MLI has high transmittance to radiowaves, but blocks infrared radiation. For example, RT-MLI with 12 layers has a transmittance greater than 95% (lower than 1%) below 200 GHz (above 4 THz). We demonstrated its effects in a system with absorptive-type filters, where aperture diameters were 200 mm. Low temperatures were successfully maintained for the filters. We conclude that this technology significantly enhances the cooling of radiowave receivers, and is particularly suitable for large-aperture systems. This technology is expected to be applicable to various fields, including radio astronomy, geo-environmental assessment, and radar systems.
△ Less
Submitted 18 October, 2013; v1 submitted 20 June, 2013;
originally announced June 2013.
-
Cryogenic cooling with cryocooler on a rotating system
Authors:
Shugo Oguri,
Jihoon Choi,
Masanori Kawai,
Osamu Tajima
Abstract:
We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the cryocooler. The operation of the cryocooler and other instruments requires the development of interface…
▽ More
We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the cryocooler. The operation of the cryocooler and other instruments requires the development of interface components between the ground and rotating table. A combination of access holes at the center of the table and two rotary joints allows simultaneous circulation of electricity and helium gas. The developed system provides two innovative functions under the rotating condition; cooling from room temperature and the maintenance of a cold condition for long periods. We have confirmed these abilities as well as temperature stability under a condition of continuous rotation at 20 revolutions per minute. The developed system can be applied in various fields; e.g., in tests of Lorentz invariance, searches for axion, radio astronomy and cosmology, and application of radar systems. In particular, there is a plan to use this system for a radio telescope observing cosmic microwave background radiation.
△ Less
Submitted 12 May, 2013; v1 submitted 21 March, 2013;
originally announced March 2013.
-
Innovative Demodulation Scheme for Coherent Detectors in CMB Experiments
Authors:
K. Ishidoshiro,
Y. Chinone,
M. Hasegawa,
M. Hazumi,
M. Nagai,
O. Tajima
Abstract:
We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which…
▽ More
We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two- point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.
△ Less
Submitted 21 May, 2012; v1 submitted 12 March, 2012;
originally announced March 2012.
-
Readout system with on-board demodulation for CMB polarization experiments using coherent polarimeter arrays
Authors:
Koji Ishidoshiro,
Makoto Nagai,
Takeo Higuchi,
Masaya Hasegawa,
Masashi Hazumi,
Masahiro Ikeno,
Osamu Tajima,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
B-modes are special patterns in cosmic microwave background (CMB) polarization. The detection of them is a smoking-gun signature of primordial gravitational waves. The generic strategy of the CMB polarization experiments is to employ a large number of polarimeters for improving the statistics. The Q/U Imaging ExperimenT-II (QUIET-II) has been proposed to detect the B-modes using the world's larges…
▽ More
B-modes are special patterns in cosmic microwave background (CMB) polarization. The detection of them is a smoking-gun signature of primordial gravitational waves. The generic strategy of the CMB polarization experiments is to employ a large number of polarimeters for improving the statistics. The Q/U Imaging ExperimenT-II (QUIET-II) has been proposed to detect the B-modes using the world's largest coherent polarimeter array (2,000 channels). An unique detection technique using QUIET's polarimeters, which is a modula- tion/demodulation scheme, enables us directly extracting the polarization signal. The extracted signal is free from non- polarized components and intrinsic 1/f noise. We developed a data readout system with on-board demodulation functions for the QUIET-II experiment. We employed a "master" clock strategy. This strategy guarantees phase matching between the modulation by the polarimeters and the demodulation by ADC modules. The single master generates all carrier clocks and distributes them to each module. The developed electronics, clock modules, and the ADC modules fulfill requirements. Tests with a setup similar to that of the real experiment proved that the system works properly. The performance of all system components are validated to be suitable for B-mode measurements.
△ Less
Submitted 10 February, 2012; v1 submitted 3 December, 2011;
originally announced December 2011.
-
Compensation of the Crossing Angle with Crab Cavities at KEKB
Authors:
T. Abe,
K. Akai,
M. Akemoto,
A. Akiyama,
M. Arinaga,
K. Ebihara,
K. Egawa,
A. Enomoto,
J. Flanagan,
S. Fukuda,
H. Fukuma,
Y. Funakoshi,
K. Furukawa,
T. Furuya,
K. Hara,
T. Higo,
S. Hiramatsu,
H. Hisamatsu,
H. Honma,
T. Honma,
K. Hosoyama,
T. Ieiri,
N. Iida,
H. Ikeda,
M. Ikeda
, et al. (90 additional authors not shown)
Abstract:
Crab cavities have been installed in the KEKB B--Factory rings to compensate the crossing angle at the collision point and thus increase luminosity. The beam operation with crab crossing has been done since February 2007. This is the first experience with such cavities in colliders or storage rings. The crab cavities have been working without serious issues. While higher specific luminosity than…
▽ More
Crab cavities have been installed in the KEKB B--Factory rings to compensate the crossing angle at the collision point and thus increase luminosity. The beam operation with crab crossing has been done since February 2007. This is the first experience with such cavities in colliders or storage rings. The crab cavities have been working without serious issues. While higher specific luminosity than the geometrical gain has been achieved, further study is necessary and under way to reach the prediction of simulation.
△ Less
Submitted 21 June, 2007;
originally announced June 2007.
-
An Overview of the KamLAND 1-kiloton Liquid Scintillator
Authors:
F. Suekane,
T. Iwamoto,
H. Ogawa,
O. Tajima,
H. Watanabe
Abstract:
KamLAND is a massive liquid-scintillator-based neutrino detector studying low energy neutrino oscillation. The experiment has discovered a large deficit of the reactor neutrino flux with baseline of 180km in the year 2002. This result is placing a strong impact on the elementary particle physics. The KamLAND detector makes use of one kiloton of liquid scintillator (LS) as the active neutrino tar…
▽ More
KamLAND is a massive liquid-scintillator-based neutrino detector studying low energy neutrino oscillation. The experiment has discovered a large deficit of the reactor neutrino flux with baseline of 180km in the year 2002. This result is placing a strong impact on the elementary particle physics. The KamLAND detector makes use of one kiloton of liquid scintillator (LS) as the active neutrino target. This is the largest homogeneous LS detector in the world. Although the light yield and attenuation length of the LS were measured to be 57% anthracene and ~10m, in the test experiments, when it is used in the KamLAND detector, the effective transparency and light yield significantly increased from these values, presumably due to the scattering and re-emission in the large scale LS. The radio active contamination in the LS is extremely low, such as 3.5E-18g/g for uranium. This is the world's lowest contamination record so far achieved and measured. The success of the KamLAND experiment is a fruit of this high-quality and large-quantity LS. In this proceedings, an outline of the LS is described.
△ Less
Submitted 20 April, 2004; v1 submitted 14 April, 2004;
originally announced April 2004.