Feasibility study of multiplexing analog signals from SiPMs for a single layer monolithic PET detector design
Authors:
Shiv K. Subedi,
Simon R. Cherry,
Yi Qiang,
Peng Peng
Abstract:
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design,…
▽ More
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design, a single layer LSO crystal was used with dimensions 40 mm*40 mm*40 mm, with 0.60 mm thickness of the ESR (enhanced specular reflector) films covering the crystal's top and bottom surfaces. The photons generated in the scintillation process induced by the gamma ray hitting the crystal were detected by four 1*8 SiPM (silicon photomultiplier) arrays placed along the four sides of the crystal. The scintillation light distribution detected by all of the 32 SiPMs surrounding the crystal layer was then used to extract the gamma-crystal interaction location based on machine learning analysis. In this work, the spatial resolution of the detector module was explored when analog signals from each of the 32 SiPMs were summed to 28, 24, 20, 16, 12, 8, and 4 total outputs. This study showed that good spatial resolution can be achieved even when the number of read out channels is decreased by multiplexing, which can reduce the overall detector manufacturing cost.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
The $^{3}$He BF$_{3}$ Giant Barrel (HeBGB) Neutron Detector
Authors:
K. Brandenburg,
G. Hamad,
Z. Meisel,
C. R. Brune,
D. E. Carter,
T. Danley,
J. Derkin,
Y. Jones-Alberty,
B. Kenady,
T. N. Massey,
S. Paneru,
M. Saxena,
D. Soltesz,
S. K. Subedi,
J. Warren
Abstract:
$(α,n)$ reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total $(α,n)…
▽ More
$(α,n)$ reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total $(α,n)$ cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. The $^{3}{\rm He}\,{\rm BF}_{3}$ Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of ($7.5\pm 1.2$) \% over the neutron energy range 0.01 MeV -- 9.00 MeV, removing a significant source of systematic uncertainty present in earlier $(α,n)$ cross section measurements.
△ Less
Submitted 6 April, 2022; v1 submitted 19 November, 2021;
originally announced November 2021.