-
Electron FLASH platform for pre-clinical research: LINAC modification, simplification of pulse control and dosimetry
Authors:
Banghao Zhou,
Lixiang Guo,
Weiguo Lu,
Mahbubur Rahman,
Rongxiao Zhang,
Varghese Anto Chirayath,
Yang Kyun Park,
Strahinja Stojadinovic,
Marvin Garza,
Ken Kang-Hsin Wang
Abstract:
Background: FLASH radiotherapy is a treatment regime that delivers therapeutic dose to tumors at an ultra-high dose rate while maintaining adequate normal tissue sparing. However, a comprehensive understanding of the underlying mechanisms, potential late toxicities, and optimal fractionation schemes is important for successful clinical translation. This has necessitated extensive pre-clinical inve…
▽ More
Background: FLASH radiotherapy is a treatment regime that delivers therapeutic dose to tumors at an ultra-high dose rate while maintaining adequate normal tissue sparing. However, a comprehensive understanding of the underlying mechanisms, potential late toxicities, and optimal fractionation schemes is important for successful clinical translation. This has necessitated extensive pre-clinical investigations, leading several research institutions to initiate dedicated FLASH research programs. Purpose: This work describes a workflow for establishing an easily accessible electron FLASH (eFLASH) platform. The platform incorporates simplified pulse control, optimized dose rate delivery, and validated Monte Carlo (MC) dose engine for accurate in vivo dosimetry dedicated to FLASH pre-clinical studies. Methods: Adjustment of the automatic frequency control (AFC) module allowed us to optimize the LINAC pulse form to achieve a uniform dose rate. A MC model for the 6 MeV FLASH beam was commissioned to ensure accurate dose calculation necessary for reproducible in vivo studies. Results: Optimizing the AFC module enabled the generation of a uniform pulse form, ensuring consistent dose per pulse and a uniform dose rate throughout FLASH irradiation. The MC model closely agreed with film measurements. MC dose calculations indicated that 6 MeV FLASH is adequate to achieve a uniform dose distribution for mouse whole brain irradiation but may not be optimal for the spinal cord study. Conclusions: We present a novel workflow for establishing a LINAC-based eFLASH research platform, incorporating techniques for optimized dose rate delivery, a simplified pulse control system, and validated MC engine. This work provides researchers with valuable new approaches to facilitate the development of robust and accessible LINAC-based system for FLASH studies.
△ Less
Submitted 27 August, 2024;
originally announced August 2024.
-
Multiomics-based Outcome Prediction for the Treatment of Brain Metastases with Personalized Ultra-fractionated Stereotactic Adaptive Radiotherapy (PULSAR)
Authors:
Haozhao Zhang,
Michael Dohopolski,
Strahinja Stojadinovic,
Luiza Giuliani,
Soummitra Anand,
Heejung Kim,
Arnold Pompos,
Andrew Godley,
Steve Jiang,
Tu Dan,
Zabi Wardak,
Robert Timmerman,
Hao Peng
Abstract:
Purpose: We aimed to develop a data-driven multiomics approach integrating radiomics, dosiomics, and delta features to predict treatment response at an earlier stage (intra-treatment) for brain metastases (BMs) patients treated with PULSAR. Methods: We conducted a retrospective study of 39 patients with 69 BMs treated with PULSAR. Radiomics, dosiomics, and delta features were extracted from pretre…
▽ More
Purpose: We aimed to develop a data-driven multiomics approach integrating radiomics, dosiomics, and delta features to predict treatment response at an earlier stage (intra-treatment) for brain metastases (BMs) patients treated with PULSAR. Methods: We conducted a retrospective study of 39 patients with 69 BMs treated with PULSAR. Radiomics, dosiomics, and delta features were extracted from pretreatment and intra-treatment MRI scans and dose distributions. Six individual models and an ensemble feature selection (EFS) model were constructed using SVM and evaluated via stratified 5-fold cross-validation. The classification task distinguished lesions with >20% volume reduction at follow-up. We assessed performance metrics including sensitivity, specificity, accuracy, precision, F1 score, and AUC. Various feature extraction and ensemble selection scenarios were explored to enhance model robustness and reduce overfitting. Results: The EFS model, integrating features from pre-treatment radiomics and dosiomics, intra-treatment radiomics, and delta-radiomics, outperformed six individual models. It achieved an AUC of 0.979, accuracy of 0.917, and F1 score of 0.821. Among the top 9 features, six were derived from post-wavelet transformation, and three from original images. The discrete wavelet transform decomposes volumetric images into multi-resolution components, offering a more comprehensive characterization of underlying structures. Conclusion: Our study demonstrated the feasibility of employing a data-driven multiomics approach to predict tumor volume changes in BMs patients with PULSAR. The EFS model demonstrates enhanced performance compared with six individual models, emphasizing the importance of integrating both pretreatment and intra-treatment data. This application holds promise for optimizing BMs management, potentially mitigating risks associated with under- or over-treatment.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
Characterization of AlW oxide coatings on aluminum formed by pulsed direct current plasma electrolytic oxidation at ultralow duty cycles
Authors:
Kristina Mojsilovic,
nenad Tadic,
Uros Lacnjevac,
Stevan Stojadinovic,
Rastko Vasilic
Abstract:
The growth of thin oxide coatings on the aluminum substrate in water-based sodium tungstate electrolyte by plasma electrolytic oxidation (PEO) is discussed and experimentally illustrated. The growth is carried out using a distinctive ultra-low duty cycle pulsed direct current (DC) power supply. During the PEO processing elements present in micro-discharges are identified using standard optical emi…
▽ More
The growth of thin oxide coatings on the aluminum substrate in water-based sodium tungstate electrolyte by plasma electrolytic oxidation (PEO) is discussed and experimentally illustrated. The growth is carried out using a distinctive ultra-low duty cycle pulsed direct current (DC) power supply. During the PEO processing elements present in micro-discharges are identified using standard optical emission spectroscopy (OES) technique. The spectral line shape analysis of the first two hydrogen Balmer lines shows the presence of two types of micro-discharges. Obtained coatings are also characterized with respect to their morphology and chemical and phase composition. It is shown that coatings are composed of Al, O, and W, featuring low roughness and porosity. Partial crystallization of the coatings resulted in identification of WO3, W3O8, and gamma-Al2O3 crystalline phases.
△ Less
Submitted 27 October, 2022;
originally announced October 2022.
-
Zeolite-based photocatalysts immobilized on aluminum support by plasma electrolytic oxidation
Authors:
K. Mojsilovic,
N. Bozovic,
S. Stojanovic,
L. Damjanovic-Vasilic,
M. Serdechnova,
C. Blawert,
M. L. Zheludkevich,
S. Stojadinovic,
R. Vasilic
Abstract:
The preparation and properties of zeolite-containing oxide coatings obtained by plasma electrolytic oxidation are investigated and discussed. Pure and Ce-exchanged natural (clinoptilolite) and synthetic (13X) zeolites are immobilized on aluminum support from silicate-based electrolyte. Obtained coatings are characterized with respect to their morphology, phase and chemical composition, photocataly…
▽ More
The preparation and properties of zeolite-containing oxide coatings obtained by plasma electrolytic oxidation are investigated and discussed. Pure and Ce-exchanged natural (clinoptilolite) and synthetic (13X) zeolites are immobilized on aluminum support from silicate-based electrolyte. Obtained coatings are characterized with respect to their morphology, phase and chemical composition, photocatalytic activity and anti-corrosion properties. It is observed that all mentioned properties of obtained coatings are dependent on processing time and type of immobilized zeolite. Coatings with Ce-exchanged zeolite show higher photocatalytic activity and more effective corrosion protection than those with pure zeolite. The highest photocatalytic activity is observed for coatings processed in pulsed a DC regime for 30 minutes containing Ce-exchanged 13X zeolite, followed by those containing Ce-exchanged clinoptilolite. Pronounced anti-corrosion properties feature almost all samples containing Ce-exchanged 13X zeolite.
△ Less
Submitted 27 October, 2022;
originally announced October 2022.