The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam
Authors:
G. Auzinger,
H. Bakhshiansohi,
A. E. Dabrowski,
A. G. Delannoy,
V. Dalavi,
N. Dienemann,
M. Dragicevic,
M. F. Garcia,
M. Guthoff,
B. Gyöngyösi,
M. Jenihhin,
Á. Kadlecsik,
J. Kaplon,
O. Karacheban,
B. Korcsmáros,
A. Lokhovitskiy,
W. H. Liu,
R. Loos,
S. Mallows,
D. Mihhailov,
M. Obradovic,
S. Orfanelli,
M. Pari,
G. Pásztor,
F. L. Pereira Carneiro
, et al. (18 additional authors not shown)
Abstract:
The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the…
▽ More
The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time of arrival and time over threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.
△ Less
Submitted 7 July, 2025;
originally announced July 2025.
-
Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC
Authors:
K. Shibin,
G. Auzinger,
H. Bakhshiansohi,
A. Dabrowski,
A. Dierlamm,
M. Dragicevic,
A. Gholami,
G. Gomez,
M. Guthoff,
M. Haranko,
A. Homna,
M. Jenihhin,
J. Kaplon,
O. Karacheban,
B. Korcsmáros,
A. Lokhovitskiy,
R. Loos,
S. Mallows,
J. Michel,
V. Myronenko,
G. Pásztor,
J. Schwandt,
M. Sedghi,
A. Shevelev,
G. Steinbrueck
, et al. (2 additional authors not shown)
Abstract:
The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times wi…
▽ More
The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times with a triggerless asynchronous readout. FBCM utilizes a dedicated front-end ASIC to amplify the signals from CO$_2$-cooled silicon-pad sensors with 1 ns timing resolution. Front-end (FE) electronics are subject to high-radiation conditions, thus all components are radiation hardened: sensors, ASICs, transceivers, etc. The FBCM ASIC contains 6 channels, each outputting a high-speed binary signal carrying the time-of-arrival and time-over-threshold information. This signal is sent via a gigabit optical link to the back-end electronics for analysis. A dedicated test system is designed for the FBCM FE electronics with a modular setup for all testing needs of the project from initial ASIC validation test to system-level testing with the full read-out chain. The paper reports on the design, read-out architecture, and testing program for the FBCM electronics.
△ Less
Submitted 18 October, 2024;
originally announced October 2024.
-
The CMS Fast Beam Condition Monitor for HL-LHC
Authors:
G. Auzinger,
H. Bakhshiansohi,
A. Dabrowski,
A. G. Delannoy,
A. Dierlamm,
M. Dragicevic,
A. Gholami,
G. Gomez,
M. Guthoff,
M. Haranko,
A. Homna,
M. Jenihhin,
J. Kaplon,
O. Karacheban,
B. Korcsmáros,
W. H. Liu,
A. Lokhovitskiy,
R. Loos,
S. Mallows,
J. Michel,
V. Myronenko,
G. Pásztor,
M. Pari,
J. Schwandt,
M. Sedghi
, et al. (6 additional authors not shown)
Abstract:
The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and dat…
▽ More
The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and data acquisition services and able to operate at all times with a triggerless readout. FBCM utilizes a dedicated front-end application-specific integrated circuit (ASIC) to amplify the signals from CO$_2$-cooled silicon-pad sensors with a timing resolution of a few nanoseconds, which enables the measurement of the beam-induced background. FBCM uses a modular design with two half-disks of twelve modules at each end of CMS, with four service modules placed close to the outer edge to reduce radiation-induced aging. The electronics system design adapts several components from the CMS Tracker for power, control and read-out functionalities. The dedicated FBCM23 ASIC contains six channels and adjustable shaping time to optimize the noise with regards to sensor leakage current. Each ASIC channel outputs a single binary high-speed asynchronous signal carrying time-of-arrival and time-over-threshold information. The chip output signal is digitized, encoded and sent via a radiation-hard gigabit transceiver and an optical link to the back-end electronics for analysis. This paper reports on the updated design of the FBCM detector and the ongoing testing program.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Impact of Beam-Beam Effects on Absolute Luminosity Calibrations at the CERN Large Hadron Collider
Authors:
A. Babaev,
T. Barklow,
O. Karacheban,
W. Kozanecki,
I. Kralik,
A. Mehta,
G. Pasztor,
T. Pieloni,
D. Stickland,
C. Tambasco,
R. Tomas,
J. Wańczyk
Abstract:
At the Large Hadron Collider (LHC), absolute luminosity calibrations obtained by the van der Meer (vdM) method are affected by the mutual electromagnetic interaction of the two beams. The colliding bunches experience relative orbit shifts, as well as optical distortions akin to the dynamic-$β$ effect, that both depend on the transverse beam separation and must therefore be corrected for when deriv…
▽ More
At the Large Hadron Collider (LHC), absolute luminosity calibrations obtained by the van der Meer (vdM) method are affected by the mutual electromagnetic interaction of the two beams. The colliding bunches experience relative orbit shifts, as well as optical distortions akin to the dynamic-$β$ effect, that both depend on the transverse beam separation and must therefore be corrected for when deriving the absolute luminosity scale. In the vdM regime, the beam-beam parameter is small enough that the orbit shift can be calculated analytically. The dynamic-$β$ corrections to the luminometer calibrations, however, had until the end of Run 2 been estimated in the linear approximation only. In this report, the influence of beam-beam effects on the vdM-based luminosity scale is quantified, together with the associated systematic uncertainties, by means of simulations that fully take into account the non-linearity of the beam-beam force, as well as the resulting non-Gaussian distortions of the transverse beam distributions. Two independent multiparticle simulations, one limited to the weak-strong approximation and one that models strong-strong effects in a self-consistent manner, are found in excellent agreement; both predict a percent-level shift of the absolute pp-luminosity values with respect to those assumed until recently in the physics publications of the LHC experiments. These results also provide guidance regarding further studies aimed at reducing the beam-beam-related systematic uncertainty on beam-beam corrections to absolute luminosity calibrations by the van der Meer method.
△ Less
Submitted 19 April, 2024; v1 submitted 17 June, 2023;
originally announced June 2023.
-
Lift and drag forces acting on a particle moving with zero slip velocity near a wall
Authors:
Nilanka. I. K. Ekanayake,
Joseph D. Berry,
Anthony D. Stickland,
David E. Dunstan,
Ineke L. Muir,
Steven K. Dower,
Dalton J. E. Harvie
Abstract:
The lift and drag forces acting on a small, neutrally-buoyant spherical particle in a single-wall-bounded linear shear flow are examined via numerical computation. The effects of shear rate are isolated from those of slip by setting the particle velocity equal to the local fluid velocity (zero slip), and examining the resulting hydrodynamic forces as a function of separation distance. In contrast…
▽ More
The lift and drag forces acting on a small, neutrally-buoyant spherical particle in a single-wall-bounded linear shear flow are examined via numerical computation. The effects of shear rate are isolated from those of slip by setting the particle velocity equal to the local fluid velocity (zero slip), and examining the resulting hydrodynamic forces as a function of separation distance. In contrast to much of the previous numerical literature, low shear Reynolds numbers are considered ($10^{-3} \lesssim Re_γ \lesssim 10^{-1}$). This shear rate range is relevant when dealing with particulate flows within small channels, for example particle migration in microfluidic devices being used or developed for the biotech industry. We demonstrate a strong dependence of both the lift and drag forces on shear rate. Building on previous theoretical $Re_γ \ll 1$ studies, a wall-shear based lift correlation is proposed that is applicable when the wall lies both within the inner and outer regions of the disturbed flow. Similarly, we validate an improved drag correlation that includes higher order terms in wall separation distance that more accurately captures the drag force when the particle is close to, but not touching, the wall. Application of the new correlations shows that the examined shear based lift force is as important as the previously examined slip based lift force, highlighting the need to account for shear when predicting the near-wall movement of neutrally-buoyant particles.
△ Less
Submitted 14 February, 2020;
originally announced February 2020.
-
Fast Beam Condition Monitor for CMS: performance and upgrade
Authors:
Jessica L. Leonard,
Alan Bell,
Piotr Burtowy,
Anne Dabrowski,
Maria Hempel,
Hans Henschel,
Wolfgang Lange,
Wolfgang Lohmann,
Nathaniel Odell,
Marek Penno,
Brian Pollack,
Dominik Przyborowski,
Vladimir Ryjov,
David Stickland,
Roberval Walsh,
Weronika Warzycha,
Agnieszka Zagozdzinska
Abstract:
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is b…
▽ More
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.
△ Less
Submitted 8 May, 2014;
originally announced May 2014.
-
Measurement of the CMS Magnetic Field
Authors:
V. I. Klyukhin,
A. Ball,
F. Bergsma,
D. Campi,
B. Curé,
A. Gaddi,
H. Gerwig,
A. Hervé,
J. Korienek,
F. Linde,
C. Lindenmeyer,
R. Loveless,
M. Mulders,
T. Nebel,
R. P. Smith,
D. Stickland,
G. Teafoe,
L. Veillet,
J. K. Zimmerman
Abstract:
The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurement…
▽ More
The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.
△ Less
Submitted 3 October, 2011;
originally announced October 2011.
-
Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC
Authors:
R. S. Schmidt,
A. J. Bell,
E. Castro,
R. Hall-Wilton,
M. Hempel,
W. Lange,
W. Lohmann,
S. Müller,
V. Ryjov,
D. Stickland,
R. Walsh
Abstract:
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data…
▽ More
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to the CMS detector, a beam abort is induced.
The Fast Beam Conditions Monitor, BCM1F, is a flux counter close to the beam pipe inside the tracker volume. It uses single-crystal CVD diamond sensors, radiation-hard FE electronics, and optical signal transmission to measure the beam halo as well as collision products bunch by bunch. The system has been operational during the initiatory runs of LHC in September 2008. It works reliably since the restart in 2009 and is invaluable to CMS for everyday LHC operation. A characterisation of the system on the basis of data collected during LHC operation is presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.