Skip to main content

Showing 1–8 of 8 results for author: Stickland, D

Searching in archive physics. Search in all archives.
.
  1. arXiv:2507.05423  [pdf, ps, other

    hep-ex physics.ins-det

    The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

    Authors: G. Auzinger, H. Bakhshiansohi, A. E. Dabrowski, A. G. Delannoy, V. Dalavi, N. Dienemann, M. Dragicevic, M. F. Garcia, M. Guthoff, B. Gyöngyösi, M. Jenihhin, Á. Kadlecsik, J. Kaplon, O. Karacheban, B. Korcsmáros, A. Lokhovitskiy, W. H. Liu, R. Loos, S. Mallows, D. Mihhailov, M. Obradovic, S. Orfanelli, M. Pari, G. Pásztor, F. L. Pereira Carneiro , et al. (18 additional authors not shown)

    Abstract: The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the… ▽ More

    Submitted 7 July, 2025; originally announced July 2025.

    Comments: 33 pages, 32 figures, prepared for submission to JINST

  2. arXiv:2410.14867  [pdf, other

    physics.ins-det hep-ex

    Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC

    Authors: K. Shibin, G. Auzinger, H. Bakhshiansohi, A. Dabrowski, A. Dierlamm, M. Dragicevic, A. Gholami, G. Gomez, M. Guthoff, M. Haranko, A. Homna, M. Jenihhin, J. Kaplon, O. Karacheban, B. Korcsmáros, A. Lokhovitskiy, R. Loos, S. Mallows, J. Michel, V. Myronenko, G. Pásztor, J. Schwandt, M. Sedghi, A. Shevelev, G. Steinbrueck , et al. (2 additional authors not shown)

    Abstract: The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real time. A key component of the CMS Beam Radiation Instrumentation and Luminosity detector system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is able to operate independently at all times wi… ▽ More

    Submitted 18 October, 2024; originally announced October 2024.

    Comments: 6 pages, 5 figures. Presented at 6th International Conference on Technology and Instrumentation in Particle Physics (TIPP2023), 4-8 Sep 2023, Cape Town, Western Cape, South Africa. Submitted to PoS(TIPP2023)

    Report number: CERN CMS-CR-2024/164

  3. arXiv:2402.03971  [pdf, other

    physics.ins-det

    The CMS Fast Beam Condition Monitor for HL-LHC

    Authors: G. Auzinger, H. Bakhshiansohi, A. Dabrowski, A. G. Delannoy, A. Dierlamm, M. Dragicevic, A. Gholami, G. Gomez, M. Guthoff, M. Haranko, A. Homna, M. Jenihhin, J. Kaplon, O. Karacheban, B. Korcsmáros, W. H. Liu, A. Lokhovitskiy, R. Loos, S. Mallows, J. Michel, V. Myronenko, G. Pásztor, M. Pari, J. Schwandt, M. Sedghi , et al. (6 additional authors not shown)

    Abstract: The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and dat… ▽ More

    Submitted 6 February, 2024; originally announced February 2024.

    Comments: 16th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD23) 2023 Sept 25-29 Siena, Italy

  4. Impact of Beam-Beam Effects on Absolute Luminosity Calibrations at the CERN Large Hadron Collider

    Authors: A. Babaev, T. Barklow, O. Karacheban, W. Kozanecki, I. Kralik, A. Mehta, G. Pasztor, T. Pieloni, D. Stickland, C. Tambasco, R. Tomas, J. Wańczyk

    Abstract: At the Large Hadron Collider (LHC), absolute luminosity calibrations obtained by the van der Meer (vdM) method are affected by the mutual electromagnetic interaction of the two beams. The colliding bunches experience relative orbit shifts, as well as optical distortions akin to the dynamic-$β$ effect, that both depend on the transverse beam separation and must therefore be corrected for when deriv… ▽ More

    Submitted 19 April, 2024; v1 submitted 17 June, 2023; originally announced June 2023.

  5. arXiv:2002.06142  [pdf, other

    physics.flu-dyn

    Lift and drag forces acting on a particle moving with zero slip velocity near a wall

    Authors: Nilanka. I. K. Ekanayake, Joseph D. Berry, Anthony D. Stickland, David E. Dunstan, Ineke L. Muir, Steven K. Dower, Dalton J. E. Harvie

    Abstract: The lift and drag forces acting on a small, neutrally-buoyant spherical particle in a single-wall-bounded linear shear flow are examined via numerical computation. The effects of shear rate are isolated from those of slip by setting the particle velocity equal to the local fluid velocity (zero slip), and examining the resulting hydrodynamic forces as a function of separation distance. In contrast… ▽ More

    Submitted 14 February, 2020; originally announced February 2020.

    Comments: Currently submitted to JFM for review

  6. arXiv:1405.1926  [pdf

    physics.ins-det hep-ex

    Fast Beam Condition Monitor for CMS: performance and upgrade

    Authors: Jessica L. Leonard, Alan Bell, Piotr Burtowy, Anne Dabrowski, Maria Hempel, Hans Henschel, Wolfgang Lange, Wolfgang Lohmann, Nathaniel Odell, Marek Penno, Brian Pollack, Dominik Przyborowski, Vladimir Ryjov, David Stickland, Roberval Walsh, Weronika Warzycha, Agnieszka Zagozdzinska

    Abstract: The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is b… ▽ More

    Submitted 8 May, 2014; originally announced May 2014.

    Comments: 10 pages, 8 figures. To be published in NIM A as proceedings for the 9th Hiroshima Symposium on Semiconductor Tracking Detectors (2013)

    Report number: DESY 14-070

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 235-239

  7. arXiv:1110.0306  [pdf

    physics.ins-det hep-ex

    Measurement of the CMS Magnetic Field

    Authors: V. I. Klyukhin, A. Ball, F. Bergsma, D. Campi, B. Curé, A. Gaddi, H. Gerwig, A. Hervé, J. Korienek, F. Linde, C. Lindenmeyer, R. Loveless, M. Mulders, T. Nebel, R. P. Smith, D. Stickland, G. Teafoe, L. Veillet, J. K. Zimmerman

    Abstract: The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurement… ▽ More

    Submitted 3 October, 2011; originally announced October 2011.

    Comments: 4 pages, 5 figures, 15 references

    Journal ref: IEEE Trans on Appl. Superconduct., vol. 18, no. 2, pp. 295-298, June 2008

  8. Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC

    Authors: R. S. Schmidt, A. J. Bell, E. Castro, R. Hall-Wilton, M. Hempel, W. Lange, W. Lohmann, S. Müller, V. Ryjov, D. Stickland, R. Walsh

    Abstract: The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data… ▽ More

    Submitted 16 December, 2010; originally announced December 2010.

    Comments: 6 pages, 6 figures. To be published in the Journal of Instrumentation (JINST), Proceedings of the Topical Workshop on Electronics for Particle Physics 2010

    Report number: DESY-10-208