-
Development of the front-end electronics for a cost-effective PET-like detector system
Authors:
Josephine Oppotsch,
Nadia Böhle,
Thomas Held,
Mario Fink,
Miriam Fritsch,
Fritz-Herbert Heinsius,
Matthias Steinke,
Ulrich Wiedner
Abstract:
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and developing custom 2 x 2 silicon photomultiplier (SiPM) arrays…
▽ More
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and developing custom 2 x 2 silicon photomultiplier (SiPM) arrays, preamplifiers, and discriminators. The use of long (20 mm x 20 mm x 1000 mm) plastic scintillator bars read out with photodetectors only at their respective ends allows an overall smaller number of photodetectors and associated readout electronics, which in turn reduces the overall cost of the system. In addition, the development of a custom SiPM array and preamplifier allows a free selection of interconnection and readout, as most commercial producers only offer specific types of interconnections and therefore lack other connections such as serial or hybrid. Thus, several common circuit types for SiPMs and preamplifiers were tested and compared in this work, and it was found that a serial connection implemented in a hybrid interconnection for the SiPMs and an inverting preamplifier based on a high-frequency operational amplifier provided the best results for the proposed detector system. Measured with a Na-22 source, the combination of SiPM array and preamplifier led to a rise time of 3.7 ns and a signal amplitude of 175 mV.
△ Less
Submitted 28 October, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
-
A simulation study on spatial and time resolution for a cost-effective positron emission particle tracking system
Authors:
Josephine Oppotsch,
Matthias Steinke,
Miriam Fritsch,
Fritz-Herbert Heinsius,
Thomas Held,
Nikoline Hilse,
Viktor Scherer,
Ulrich Wiedner
Abstract:
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very expensive, a PET-like detector system based on cost-effective organic plastic scintillator bars is being developed and tested for its capabilities. In this context,…
▽ More
This work is the second part of a simulation study investigating the processing of densely packed and moving granular assemblies by positron emission particle tracking (PEPT). Since medical PET scanners commonly used for PEPT are very expensive, a PET-like detector system based on cost-effective organic plastic scintillator bars is being developed and tested for its capabilities. In this context, the spatial resolution of a resting positron source, a source moving on a freely designed model path, and a particle motion given by a DEM (Discrete Element Method) simulation is studied using Monte Carlo simulations and the software toolkit Geant4. This not only extended the simulation and reconstruction to a moving source but also significantly improved the spatial resolution compared to previous work by adding oversampling and iteration to the reconstruction algorithm. Furthermore, in the case of a source following a trajectory developed from DEM simulations, a very good resolution of about 1 mm in all three directions and an average three-dimensional deviation between simulated and reconstructed events of 2.3 mm could be determined. Thus, the resolution for a realistic particle motion within the generic grate system (which is the test rig for further experimental studies) is well below the smallest particle size. The simulation of the dependence of the reconstruction accuracy on tracer particle location revealed a nearly constant efficiency within the entire detector system, which demonstrates that boundary effects can be neglected.
△ Less
Submitted 15 November, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
-
Microfluidic Filling and Spectroscopy of Colloidal CdSe/CdS Nanoplatelets in Liquid Core Fibers
Authors:
Simon Spelthann,
Dan Huy Chau,
Lars F. Klepzig,
Dominik A. Rudolph,
Mario Chemnitz,
Saher Junaid,
Detlev Ristau,
Markus A. Schmidt,
Jannika Lauth,
Michael Steinke
Abstract:
Colloidal 2D semiconductor nanoplatelets are highly efficient light emitters, which exhibit large absorption and emission cross sections, and constitute promising laser gain media. However, if dispersed in solutions, such nanoplatelets lack a suitable optical platform for scalable and application-oriented integration into optical setups such as lasers. Here, we demonstrate the first successful int…
▽ More
Colloidal 2D semiconductor nanoplatelets are highly efficient light emitters, which exhibit large absorption and emission cross sections, and constitute promising laser gain media. However, if dispersed in solutions, such nanoplatelets lack a suitable optical platform for scalable and application-oriented integration into optical setups such as lasers. Here, we demonstrate the first successful integration of solution-processed 2D CdSe/CdS Core/Crown nanoplatelets in m-scale liquid core optical fibers. We compare the nanoplatelets' spectroscopic properties before and after filling them into the fibers and find that spontaneous emission is shifted and broadened. We even observe a first evidence of stimulated emission at high excitation energies. In conclusion, liquid core fibers constitute a novel and scalable platform for optical integration of nanoplatelets for applications as novel, highly reconfigurable laser gain medium.
△ Less
Submitted 16 March, 2023;
originally announced March 2023.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.