-
COSINUS -- a model-independent challenge of the DAMA/LIBRA dark matter claim with cryogenic NaI detectors operated in a new low-background facility
Authors:
G. Angloher,
M. R. Bharadwaj,
A. Böhmer,
M. Cababie,
I. Colantoni,
I. Dafinei,
N. Di Marco,
C. Dittmar,
L. Einfalt,
F. Ferella,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
M. Friedl,
L. Gai,
M. Gapp,
M. Heikinheimo,
K. Heim,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca
, et al. (18 additional authors not shown)
Abstract:
Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that combines scintillating sodium iodide (NaI) crystals with an additional phonon readout at cryogenic temperatures, using superconducting sensors (remoTES), alongside the conventional scintillation light signal. Via the simulta…
▽ More
Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that combines scintillating sodium iodide (NaI) crystals with an additional phonon readout at cryogenic temperatures, using superconducting sensors (remoTES), alongside the conventional scintillation light signal. Via the simultaneous phonon and scintillation light detection, a unique event-by-event particle identification is enabled. This dual-channel approach allows for a model-independent cross-check of the long-standing DAMA/LIBRA signal with a moderate exposure of a few hundred kg d, while completely avoiding key systematic uncertainties inherent to scintillation-only NaI-based searches. COSINUS built and commissioned a dedicated low-background cryogenic facility at the LNGS underground laboratories. Data taking with eight NaI detector modules (COSINUS1$π$ Run1) is planned to begin in late 2025.
△ Less
Submitted 3 July, 2025;
originally announced July 2025.
-
Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
L. Burmeister,
F. Casadei,
E. Cipelli,
J. Burkhart,
L. Canonica,
J. Dohm,
F. Dominsky,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
E. Fascione,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
D. Hauff
, et al. (37 additional authors not shown)
Abstract:
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observa…
▽ More
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $γ$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.
△ Less
Submitted 4 June, 2025;
originally announced June 2025.
-
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
Authors:
G. Angloher,
S. Banik,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
E. R. Cipelli,
S. Di Lorenzo,
J. Dohm,
F. Dominsky,
L. Einfalt,
A. Erb,
E. Fascione,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (32 additional authors not shown)
Abstract:
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses rangin…
▽ More
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses ranging from $\sim$2g to $\sim$24g, aiming to achieve unprecedented sensitivity to sub-GeV dark matter particles with a focus on spin-independent dark matter-nucleus scattering. This paper presents a comprehensive analysis of the planned upgrade, detailed experimental strategies, anticipated challenges, and projected sensitivities. Approaches to address and mitigate low-energy excess backgrounds $-$ a key limitation in previous and current sub-GeV dark matter searches $-$ are also discussed. In addition, a long-term roadmap for the next decade is outlined, including other potential scientific applications.
△ Less
Submitted 2 May, 2025;
originally announced May 2025.
-
COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal
Authors:
G. Angloher,
M. R. Bharadwaj,
A. Böhmer,
M. Cababie,
I. Colantoni,
I. Dafinei,
N. Di Marco,
C. Dittmar,
L. Einfalt,
F. Ferella,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro
, et al. (18 additional authors not shown)
Abstract:
COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independen…
▽ More
COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independent of the DM model. We achieve this by unfolding the DAMA modulation spectrum to obtain the implied unquenched nuclear recoil spectrum, which we compare to the expected COSINUS sensitivity. We find that assuming zero background in the signal region, a 1$σ$, 2$σ$ or 3$σ$ confidence limit exclusion can be obtained with 57, 130 or 250 kg day of exposure, respectively.
△ Less
Submitted 25 April, 2025;
originally announced April 2025.
-
Water Cherenkov muon veto for the COSINUS experiment: design and simulation optimization
Authors:
G. Angloher,
M. R. Bharadwaj,
M. Cababie,
I. Dafinei,
N. Di Marco,
L. Einfalt,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Pröbst,
G. Profeta,
A. Puiu,
F. Reindl
, et al. (14 additional authors not shown)
Abstract:
COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy,…
▽ More
COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy, and employs a large cylindrical water tank as a passive shield to meet the required background rate. However, muon-induced neutrons can mimic a DM signal therefore requiring an active veto system, which is achieved by instrumenting the water tank with an array of photomultiplier tubes (PMTs). This study optimizes the number, arrangement, and trigger conditions of the PMTs as well as the size of an optically invisible region. The objective was to maximize the muon veto efficiency while minimizing the accidental trigger rate due to the ambient and instrumental background. The final configuration predicts a veto efficiency of 99.63 $\pm$ 0.16 $\%$ and 44.4 $\pm$ $5.6\%$ in the tagging of muon events and showers of secondary particles, respectively. The active veto will reduce the cosmogenic neutron background rate to 0.11 $\pm$ 0.02 cts$\cdot$kg$^{-1}$$\cdot$year$^{-1}$, corresponding to less than one background event in the region of interest for the whole COSINUS-1$π$ exposure of 1000 kg$\cdot$days.
△ Less
Submitted 25 April, 2024;
originally announced June 2024.
-
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils i…
▽ More
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
Optimal operation of cryogenic calorimeters through deep reinforcement learning
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an…
▽ More
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.
△ Less
Submitted 25 November, 2023;
originally announced November 2023.
-
Detector development for the CRESST experiment
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of t…
▽ More
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Light Dark Matter Search Using a Diamond Cryogenic Detector
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (34 additional authors not shown)
Abstract:
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. W…
▽ More
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 9 January, 2025; v1 submitted 19 July, 2023;
originally announced July 2023.
-
Particle discrimination in a NaI crystal using the COSINUS remote TES design
Authors:
COSINUS Collaboration,
G. Angloher,
M. R. Bharadwaj,
I. Dafinei,
N. Di Marco,
L. Einfalt,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
A. Fuss,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Pröbst,
G. Profeta,
A. Puiu
, et al. (16 additional authors not shown)
Abstract:
The COSINUS direct dark matter experiment situated at Laboratori Nazionali del Gran Sasso in Italy is set to investigate the nature of the annually modulating signal detected by the DAMA/LIBRA experiment. COSINUS has already demonstrated that sodium iodide crystals can be operated at mK temperature as cryogenic scintillating calorimeters using transition edge sensors, despite the complication of h…
▽ More
The COSINUS direct dark matter experiment situated at Laboratori Nazionali del Gran Sasso in Italy is set to investigate the nature of the annually modulating signal detected by the DAMA/LIBRA experiment. COSINUS has already demonstrated that sodium iodide crystals can be operated at mK temperature as cryogenic scintillating calorimeters using transition edge sensors, despite the complication of handling a hygroscopic and low melting point material. With results from a new COSINUS prototype, we show that particle discrimination on an event-by-event basis in NaI is feasible using the dual-channel readout of both phonons and scintillation light. The detector was mounted in the novel remoTES design and operated in an above-ground facility for 9.06 g$\cdot$d of exposure. With a 3.7 g NaI crystal, e$^-$/$γ$ events could be clearly distinguished from nuclear recoils down to the nuclear recoil energy threshold of 15 keV.
△ Less
Submitted 20 July, 2023;
originally announced July 2023.
-
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff
, et al. (36 additional authors not shown)
Abstract:
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Re…
▽ More
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.
△ Less
Submitted 25 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Towards an automated data cleaning with deep learning in CRESST
Authors:
G. Angloher,
S. Banik,
D. Bartolot,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta
, et al. (40 additional authors not shown)
Abstract:
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. Wit…
▽ More
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.
△ Less
Submitted 7 January, 2023; v1 submitted 1 November, 2022;
originally announced November 2022.
-
Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (36 additional authors not shown)
Abstract:
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-b…
▽ More
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.
△ Less
Submitted 24 January, 2023; v1 submitted 22 August, 2022;
originally announced September 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Probing spin-dependent dark matter interactions with $^6$Li
Authors:
G. Angloher,
G. Benato,
A. Bento,
E. Bertoldo,
A. Bertolini,
R. Breier,
C. Bucci,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of…
▽ More
CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
First measurements of remoTES cryogenic calorimeters: easy-to-fabricate particle detectors for a wide choice of target materials
Authors:
G. Angloher,
M. R. Bharadwaj,
I. Dafinei,
N. Di Marco,
L. Einfalt,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
A. Fuss,
Z. Ge,
M. Heikinheimo,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Proebst,
G. Profeta,
A. Puiu,
F. Reindl,
K. Schaeffner
, et al. (12 additional authors not shown)
Abstract:
Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below $100$ mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results from two detector prototypes using a novel design of the thermometer coupling denoted remoTES, which further extends the applicability of the TES technology by inc…
▽ More
Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below $100$ mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results from two detector prototypes using a novel design of the thermometer coupling denoted remoTES, which further extends the applicability of the TES technology by including a wider class of potential absorber materials. In particular, this design facilitates the use of materials whose physical and chemical properties, as e.g. hygroscopicity, low hardness and low melting point, prevent the direct fabrication of the TES onto their surface. This is especially relevant in the context of the COSINUS experiment (Cryogenic Observatory for SIgnals seen in Next-Generation Underground Searches), where sodium iodide (NaI) is used as absorber material. With two remoTES prototype detectors operated in an above-ground R&D facility, we achieve energy resolutions of $σ=87.8$ eV for a $2.33$ g silicon absorber and $σ= 193.5$ eV for a $2.27$ g $α$-TeO$_{2}$ absorber, respectively. RemoTES calorimeters offer - besides the wider choice of absorber materials - a simpler production process combined with a higher reproducibility for large detector arrays and an enhanced radiopurity standard.
△ Less
Submitted 17 November, 2022; v1 submitted 30 October, 2021;
originally announced November 2021.
-
Simulation-based design study for the passive shielding of the COSINUS dark matter experiment
Authors:
G. Angloher,
I. Dafinei,
N. Di Marco,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
M. Friedl,
A. Fuss,
Z. Ge,
M. Heikinheimo,
K. Huitu,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Pröbst,
G. Profeta,
A. Puiu,
F. Reindl,
K. Schäffner,
J. Schieck,
D. Schmiedmayer,
C. Schwertner,
M. Stahlberg
, et al. (6 additional authors not shown)
Abstract:
The COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) experiment aims at the detection of dark matter-induced recoils in sodium iodide (NaI) crystals operated as scintillating cryogenic calorimeters. The detection of both scintillation light and phonons allows performing an event-by-event signal to background discrimination, thus enhancing the sensitivity…
▽ More
The COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) experiment aims at the detection of dark matter-induced recoils in sodium iodide (NaI) crystals operated as scintillating cryogenic calorimeters. The detection of both scintillation light and phonons allows performing an event-by-event signal to background discrimination, thus enhancing the sensitivity of the experiment. The construction of the experimental facility is foreseen to start by 2021 at the INFN Gran Sasso National Laboratory (LNGS) in Italy. It consists of a cryostat housing the target crystals shielded from the external radioactivity by a water tank acting, at the same time, as an active veto against cosmic ray-induced events. Taking into account both environmental radioactivity and intrinsic contamination of materials used for cryostat, shielding and infrastructure, we performed a careful background budget estimation. The goal is to evaluate the number of events that could mimic or interfere with signal detection while optimising the geometry of the experimental setup. In this paper we present the results of the detailed Monte Carlo simulations we performed, together with the final design of the setup that minimises the residual amount of background particles reaching the detector volume.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter
Authors:
A. H. Abdelhameed,
G. Angloher,
P. Bauer,
A. Bento,
E. Bertoldo,
R. Breier,
C. Bucci,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
V. M. Ghete,
A. Garai,
P. Gorla,
D. Hauff,
M. Ješkovský,
J. Jochum,
J. Kaizer,
M. Kaznacheeva,
A. Kinast
, et al. (34 additional authors not shown)
Abstract:
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cry…
▽ More
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
△ Less
Submitted 15 December, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.
-
First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li
Authors:
A. H. Abdelhameed,
G. Angloher,
P. Bauer,
A. Bento,
E. Bertoldo,
C. Bucci,
L. Canonica,
A. D'Addabbo,
X. Defay,
S. Di Lorenzo,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
A. Fuss,
P. Gorla,
D. Hauff,
J. Jochum,
A. Kinast,
H. Kluck,
H. Kraus,
A. Langenkämper,
M. Mancuso,
V. Mokina,
E. Mondragon
, et al. (31 additional authors not shown)
Abstract:
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin…
▽ More
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
△ Less
Submitted 4 September, 2019; v1 submitted 20 February, 2019;
originally announced February 2019.
-
Performance of a CRESST-II Detector Module with True $4π$-veto
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. C. Lanfranchi,
A. Langenkämper,
J. Loebell,
M. Mancuso,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst
, et al. (20 additional authors not shown)
Abstract:
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the fram…
▽ More
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the framework of the CRESST-II experiment, we developed and successfully tested a novel detector design addressing both challenges. Using a large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber, the signal height recorded in the light channel is improved by a factor 2.5 compared to conventional CRESTT-II detector modules. In combination with a large carrier crystal, a true $4π$ veto system is established which allows to tag external background sources.
△ Less
Submitted 4 August, 2017;
originally announced August 2017.
-
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
A. Langenkämper J. Loebell,
M. Mancuso,
E. Mondragon,
A. Münster,
L. Oberauer,
C. Pagliarone,
F. Petricca,
W. Potzel
, et al. (22 additional authors not shown)
Abstract:
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus e…
▽ More
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus experiment has achieved an energy threshold of $E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous results and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
△ Less
Submitted 18 September, 2017; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Direct Dark Matter Search with the CRESST II Experiment
Authors:
J Schieck,
G Angloher,
A Bento,
C Bucci,
L Canonica,
X Defay,
A Erb,
F v Feilitzsch,
N Ferreiro Iachellini,
P Gorla,
A Guetlein,
D Hauff,
J Jochum,
M Kiefer,
H Kluck,
H Kraus,
J-C Lanfranchi,
J Loebell,
M Mancuso,
A Muenster,
C Pagliarone,
F Petricca,
W Potzel,
F Pröbst,
R Puig
, et al. (18 additional authors not shown)
Abstract:
The quest for the particle nature of dark matter is one of the big open questions of modern physics. A well motivated candidate for dark matter is the so-called WIMP - a weakly interacting massive particle. Recently several theoretically well-motivated models with dark matter candidates in a mass region below the WIMP mass-scale gained also a lot of interest, theoretically and experimentally. The…
▽ More
The quest for the particle nature of dark matter is one of the big open questions of modern physics. A well motivated candidate for dark matter is the so-called WIMP - a weakly interacting massive particle. Recently several theoretically well-motivated models with dark matter candidates in a mass region below the WIMP mass-scale gained also a lot of interest, theoretically and experimentally. The CRESST II experiment located at the Gran Sasso laboratory in Italy is optimised for the detection of the elastic scattering of these low-mass dark matter particles with ordinary matter. We show the results obtained with an improved detector setup with increased radio purity and enhanced background rejection and the results obtained with a dedicated low-threshold analysis of a single conventional detector module. The limit achieved is the most stringent limit achieved for direct dark matter experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the expected performance for new small CRESST-type detectors to be used during the next data taking phase. We conclude with an outlook of the future potential for direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic detectors.
△ Less
Submitted 7 November, 2016;
originally announced November 2016.
-
IceCube-Gen2 - The Next Generation Neutrino Observatory at the South Pole: Contributions to ICRC 2015
Authors:
The IceCube-Gen2 Collaboration,
:,
M. G. Aartsen,
K. Abraham,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
D. Altmann,
T. Anderson,
I. Ansseau,
G. Anton,
M. Archinger,
C. Arguelles,
T. C. Arlen,
J. Auffenberg,
S. Axani,
X. Bai,
I. Bartos,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker Tjus
, et al. (316 additional authors not shown)
Abstract:
Papers submitted to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague) by the IceCube-Gen2 Collaboration.
Papers submitted to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague) by the IceCube-Gen2 Collaboration.
△ Less
Submitted 9 November, 2015; v1 submitted 18 October, 2015;
originally announced October 2015.