-
Optimization of Dark-Field CT for Lung Imaging
Authors:
Peiyuan Guo,
Simon Spindler,
Li Zhang,
Zhentian Wang
Abstract:
Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to now, a human-scale dark-field CT has been built for lung imaging. Purpose: This study aimed to develop a more thorough optimization method for dark-field lung C…
▽ More
Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to now, a human-scale dark-field CT has been built for lung imaging. Purpose: This study aimed to develop a more thorough optimization method for dark-field lung CT and summarize principles for system design. Methods: We proposed a metric in the form of contrast-to-noise ratio (CNR) for system parameter optimization, and designed a phantom with concentric circle shape to fit the task of lung disease detection. Finally, we developed the calculation method of the CNR metric, and analyzed the relation between CNR and system parameters. Results: We showed that with other parameters held constant, the CNR first increases and then decreases with the system auto-correlation length (ACL). The optimal ACL is nearly not influenced by system's visibility, and is only related to phantom's property, i.e., scattering material's size and phantom's absorption. For our phantom, the optimal ACL is about 0.21 μm. As for system geometry, larger source-detector and isocenter-detector distance can increase the system's maximal ACL, helping the system meet the optimal ACL more easily. Conclusions: This study proposed a more reasonable metric and a task-based process for optimization, and demonstrated that the system optimal ACL is only related to the phantom's property.
△ Less
Submitted 1 May, 2024; v1 submitted 30 April, 2024;
originally announced May 2024.
-
Refraction beats attenuation in breast CT
Authors:
Michał Rawlik,
Alexandre Pereira,
Simon Spindler,
Zhentian Wang,
Lucia Romano,
Konstantins Jefimovs,
Zhitian Shi,
Maxim Polikarpov,
Jinqiu Xu,
Marie-Christine Zdora,
Stefano van Gogh,
Martin Stauber,
Eduardo Yukihara,
Jeppe Brage Christensen,
Rahel Kubik-Huch,
Tilo Niemann,
Cornelia Leo,
Zsuzsanna Varga,
Andreas Boss,
Marco Stampanoni
Abstract:
For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grat…
▽ More
For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grating interferometry (GI) could eventually allow computed tomography (CT) to be more dose-efficient. However, the benefit of refraction in clinical CT has not been demonstrated so far. Here we show that GI-CT is more dose-efficient in imaging of breast tissue than conventional CT. Our system, based on a 70kVp X-ray tube source and commercially available gratings, demonstrated superior quality, in terms of adipose-to-glandular tissue contrast-to-noise ratio (CNR), of refraction-contrast compared to the attenuation images. The fusion of the two modes of contrast outperformed conventional CT for spatial resolutions better than 263μm and an average dose to the breast of 16mGy, which is in the clinical breast CT range. Our results show that grating interferometry can significantly reduce the dose, while maintaining the image quality, in diagnostic breast CT. Unlike conventional absorption-based CT, the sensitivity of refraction-based imaging is far from being fully exploited, and further progress will lead to significant improvements of clinical X-ray CT.
△ Less
Submitted 1 January, 2023;
originally announced January 2023.
-
The point spread function in interferometric scattering microscopy (iSCAT). I. Aberrations in defocusing and axial localization
Authors:
Reza Gholami Mahmoodabadi,
Richard W. Taylor,
Martin Kaller,
Susann Spindler,
Vahid Sandoghdar
Abstract:
Interferometric scattering (iSCAT) microscopy is an emerging label-free technique optimized for the sensitive detection of nano-matter. Previous iSCAT studies have approximated the point spread function in iSCAT by a Gaussian intensity distribution. However, recent efforts to track the mobility of nanoparticles in challenging speckle environments and over extended axial ranges has necessitated a q…
▽ More
Interferometric scattering (iSCAT) microscopy is an emerging label-free technique optimized for the sensitive detection of nano-matter. Previous iSCAT studies have approximated the point spread function in iSCAT by a Gaussian intensity distribution. However, recent efforts to track the mobility of nanoparticles in challenging speckle environments and over extended axial ranges has necessitated a quantitative description of the interferometric point spread function (iPSF). We present a robust vectorial diffraction model for the iPSF in tandem with experimental measurements and rigorous FDTD simulations. We examine the iPSF under various imaging scenarios to understand how aberrations due to the experimental configuration encode information about the nanoparticle. We show that the lateral shape of the iPSF can be used to achieve nanometric three-dimensional localization over an extended axial range on the order of 10$\,μ$m either by means of a fit to an analytical model or calibration-free unsupervised machine learning. Our results have immediate implications for three-dimensional single particle tracking in complex scattering media.
△ Less
Submitted 27 June, 2020;
originally announced June 2020.
-
Tracking single particles on supported lipid membranes: multi-mobility diffusion and nanoscopic confinement
Authors:
Chia-Lung Hsieh,
Susann Spindler,
Jens Ehrig,
Vahid Sandoghdar
Abstract:
Supported lipid bilayers have been studied intensively over the past two decades. In this work, we study the diffusion of single gold nanoparticles (GNPs) with diameter of 20 nm attached to GM1 ganglioside or DOPE lipids at different concentrations in supported DOPC bilayers. The indefinite photostability of GNPs combined with the high sensitivity of interferometric scattering microscopy (iSCAT) a…
▽ More
Supported lipid bilayers have been studied intensively over the past two decades. In this work, we study the diffusion of single gold nanoparticles (GNPs) with diameter of 20 nm attached to GM1 ganglioside or DOPE lipids at different concentrations in supported DOPC bilayers. The indefinite photostability of GNPs combined with the high sensitivity of interferometric scattering microscopy (iSCAT) allows us to achieve 1.9 nm spatial precision at 1 ms temporal resolution, while maintaining long recording times. Our trajectories visualize strong transient confinements within domains as small as 20 nm, and the statistical analysis of the data reveals multiple mobilities and deviations from normal diffusion. We present a detailed analysis of our findings and provide interpretations regarding the effect of the supporting substrate and GM1 clustering. We also comment on the use of high-speed iSCAT for investigating diffusion of lipids, proteins or viruses in lipid membranes with unprecedented spatial and temporal resolution.
△ Less
Submitted 23 December, 2013;
originally announced December 2013.