The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV
Authors:
John Arrington,
Jay Benesch,
Alexandre Camsonne,
Jimmy Caylor,
Jian-Ping Chen,
Silviu Covrig Dusa,
Alexander Emmert,
George Evans,
Haiyan Gao,
J. Ole Hansen,
Garth M. Huber,
Sylvester Joosten,
Vladimir Khachatryan,
Nilanga Liyanage,
Zein-Eddine Meziani,
Michael Nycz,
Chao Peng,
Michael Paolone,
Whit Seay,
Paul A. Souder,
Nikos Sparveris,
Hubert Spiesberger,
Ye Tian,
Eric Voutier,
Junqi Xie
, et al. (6 additional authors not shown)
Abstract:
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit…
▽ More
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3-D momentum space from Semi-Inclusive Deep Inelastic Scattering (SIDIS), expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS (PVDIS), a precision measurement of $J/ψ$ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.
△ Less
Submitted 12 February, 2023; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Precision Møller Polarimetry for PREX and CREX
Authors:
D. E. King,
D. C. Jones,
C. Gal,
D. Gaskell,
W. Henry,
A. D. Kaplan,
J. Napolitano,
S. Park,
K. D. Paschke,
R. Pomatsalyuk,
P. A. Souder
Abstract:
The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically $\approx$90\%, be known with 1\% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.…
▽ More
The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically $\approx$90\%, be known with 1\% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89\% for PREX-2, and 0.85\% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.
△ Less
Submitted 5 July, 2022;
originally announced July 2022.
-
Accurate Determination of the Electron Spin Polarization In Magnetized Iron and Nickel Foils for Møller Polarimetry
Authors:
D. C. Jones,
J. Napolitano,
P. A. Souder,
D. E. King,
W. Henry,
D. Gaskell,
K. Paschke
Abstract:
The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades reaching the typically required $\pm$1\% level of absolute uncertainty. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4\% \cite{MO…
▽ More
The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades reaching the typically required $\pm$1\% level of absolute uncertainty. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4\% \cite{MOLLER2014, SoLID2019}, requiring a systematic re-examination of all the contributing uncertainties.
Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90$^{\circ}$ in the center of mass frame where the analyzing power is a maximum (-7/9).
One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and $g^\prime$, the electron $g$-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. This paper utilizes the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294~K to be 0.08020$\pm$0.00018 (@4~T applied field) for iron and 0.018845$\pm0.000053$ (@2~T applied field) for nickel.
△ Less
Submitted 1 July, 2022; v1 submitted 21 March, 2022;
originally announced March 2022.
-
Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides
Authors:
S. Riordan,
Y. X. Zhao,
S. Baunack,
D. Becker,
C. Clarke,
K. Dehmelt,
A. Deshpande,
M. Gericke,
B. Glaser,
K. Imai,
T. Kutz,
F. E. Maas,
D. McNulty,
J. Pan,
S. Park,
S. Rahman,
P. A. Souder,
P. Wang,
B. Wellman,
K. S. Kumar
Abstract:
The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to…
▽ More
The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Møller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.
△ Less
Submitted 23 April, 2018; v1 submitted 19 October, 2017;
originally announced October 2017.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
SLAC's Polarized Electron Source Laser System and Minimization of Electron Beam Helicity Correlations for the E-158 Parity Violation Experiment
Authors:
T. B. Humensky,
R. Alley,
A. Brachmann,
M. J. Browne,
G. D. Cates,
J. Clendenin,
J. deLamare,
J. Frisch,
T. Galetto,
E. W. Hughes,
K. S. Kumar,
P. Mastromarino,
J. Sodja,
P. A. Souder,
J. Turner,
M. Woods
Abstract:
SLAC E-158 is an experiment designed to make the first measurement of parity violation in Moller scattering. E-158 will measure the right-left cross-section asymmetry, A_LR^Moller, in the elastic scattering of a 45-GeV polarized electron beam off unpolarized electrons in a liquid hydrogen target. E-158 plans to measure the expected Standard Model asymmetry of ~10^-7 to an accuracy of better than…
▽ More
SLAC E-158 is an experiment designed to make the first measurement of parity violation in Moller scattering. E-158 will measure the right-left cross-section asymmetry, A_LR^Moller, in the elastic scattering of a 45-GeV polarized electron beam off unpolarized electrons in a liquid hydrogen target. E-158 plans to measure the expected Standard Model asymmetry of ~10^-7 to an accuracy of better than 10^-8. To make this measurement, the polarized electron source requires for operation an intense circularly polarized laser beam and the ability to quickly switch between right- and left-helicity polarization states with minimal right-left helicity-correlated asymmetries in the resulting beam parameters (intensity, position, angle, spot size, and energy), ^beam A_LR's. This laser beam is produced by a unique SLAC-designed flashlamp-pumped Ti:Sapphire laser and is propagated through a carefully designed set of polarization optics. We analyze the transport of nearly circularly polarized light through the optical system and identify several mechanisms that generate ^beam A_LR's. We show that the dominant effects depend linearly on particular polarization phase shifts in the optical system. We present the laser system design and a discussion of the suppression and control of ^beam A_LR's. We also present results on beam performance from engineering and physics runs for E-158.
△ Less
Submitted 19 September, 2002; v1 submitted 18 September, 2002;
originally announced September 2002.
-
Parity Violating Measurements of Neutron Densities
Authors:
C. J. Horowitz,
S. J. Pollock,
P. A. Souder,
R. Michaels
Abstract:
Parity violating electron nucleus scattering is a clean and powerful tool for measuring the spatial distributions of neutrons in nuclei with unprecedented accuracy. Parity violation arises from the interference of electromagnetic and weak neutral amplitudes, and the $Z^0$ of the Standard Model couples primarily to neutrons at low $Q^2$. The data can be interpreted with as much confidence as elec…
▽ More
Parity violating electron nucleus scattering is a clean and powerful tool for measuring the spatial distributions of neutrons in nuclei with unprecedented accuracy. Parity violation arises from the interference of electromagnetic and weak neutral amplitudes, and the $Z^0$ of the Standard Model couples primarily to neutrons at low $Q^2$. The data can be interpreted with as much confidence as electromagnetic scattering. After briefly reviewing the present theoretical and experimental knowledge of neutron densities, we discuss possible parity violation measurements, their theoretical interpretation, and applications. The experiments are feasible at existing facilities. We show that theoretical corrections are either small or well understood, which makes the interpretation clean. The quantitative relationship to atomic parity nonconservation observables is examined, and we show that the electron scattering asymmetries can be directly applied to atomic PNC because the observables have approximately the same dependence on nuclear shape.
△ Less
Submitted 6 January, 2000; v1 submitted 15 December, 1999;
originally announced December 1999.