Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV
Authors:
Yu. V. Kharlov,
P. A. Semenov,
Yu. A. Matulenko,
O. P. Yushchenko,
Yu. I. Arestov,
G. I. Britvich,
S. K. Chernichenko,
Yu. M. Goncharenko,
A. M. Davidenko,
A. A. Derevschikov,
A. S. Konstantinov,
V. A. Kormilitsyn,
V. I. Kravtsov,
Yu. M. Melnik,
A. P. Meschanin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
A. V. Ryazantsev,
I. V. Shein,
A. P. Soldatov,
L. F. Soloviev,
A. V. Soukhikh,
A. N. Vasiliev,
M. N. Ukhanov
, et al. (2 additional authors not shown)
Abstract:
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformi…
▽ More
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformity of the prototype energy response to electrons and MIPs has turned out to be negligible. Obtained experimental results are in a good agreement with Monte-Carlo simulations.
△ Less
Submitted 22 September, 2008;
originally announced September 2008.
-
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
V. Y. Khodyrev,
A. S. Konstantinov,
V. A. Kormilitsin,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved…
▽ More
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.
△ Less
Submitted 29 September, 2005; v1 submitted 28 September, 2005;
originally announced September 2005.
-
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov,
L. F. Soloviev,
S. Stone
, et al. (4 additional authors not shown)
Abstract:
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic…
▽ More
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.
△ Less
Submitted 13 April, 2005;
originally announced April 2005.
-
Study of Possible Scintillation Mechanism Damage in PbWO4 Crystals After Pion Irradiation
Authors:
V. A. Batarin,
J. Butler,
T. Y. Chen,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
V. A. Kormilitsin,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degra…
▽ More
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degradation was observed, it would indicate damage to the scintillation mechanism. Secondly, we detected light output using two phototubes attached to sides of a crystal. Since these phototubes detect scintillation light only from a small localized region, the effect of transmission loss should be minimal. We did not see any statistically significant evidence for scintillation mechanism damage with either method. The effect is consistent with zero, and the upper limit is 0.5% at 95% C.L.
△ Less
Submitted 22 October, 2004; v1 submitted 19 October, 2004;
originally announced October 2004.
-
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
Authors:
V. A. Batarin,
J. Butler,
A. A. Derevschikov,
Yu. V. Formin,
V. Frolov,
V. N. Grishin,
V. A. Kachanov,
V. Y. Khodyrev,
A. S. Konstantinov,
V. I. Krasvtsov,
Y. Kubota,
V. M. Leontiev,
V. A. Maisheev,
Ya. A. Matulenko,
A. P. Meschanin,
Y. M. Melnick,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
P. A. Semenov,
K. E. Shestermanov,
L. F. Soloviev,
V. L. Solovianov,
S. Stone
, et al. (5 additional authors not shown)
Abstract:
A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 G…
▽ More
A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.
△ Less
Submitted 9 August, 2002;
originally announced August 2002.