Tumbling Downhill along a Given Curve
Authors:
Jean-Pierre Eckmann,
Yaroslav I. Sobolev,
Tsvi Tlusty
Abstract:
A cylinder will roll down an inclined plane in a straight line. A cone will roll around a circle on that plane and then will stop rolling. We ask the inverse question: For which curves drawn on the inclined plane $\mathbb{R}^2$ can one carve a shape that will roll downhill following precisely this prescribed curve and its translationally repeated copies? This simple question has a solution essenti…
▽ More
A cylinder will roll down an inclined plane in a straight line. A cone will roll around a circle on that plane and then will stop rolling. We ask the inverse question: For which curves drawn on the inclined plane $\mathbb{R}^2$ can one carve a shape that will roll downhill following precisely this prescribed curve and its translationally repeated copies? This simple question has a solution essentially always, but it turns out that for most curves, the shape will return to its initial orientation only after crossing a few copies of the curve - most often two copies will suffice, but some curves require an arbitrarily large number of copies.
△ Less
Submitted 24 June, 2024;
originally announced June 2024.
-
Upgrade of the ultracold neutron source at the pulsed reactor TRIGA Mainz
Authors:
Jan Kahlenberg,
Dieter Ries,
Kim Ulrike Ross,
Christian Siemensen,
Marcus Beck,
Christopher Geppert,
Werner Heil,
Nicolas Hild,
Jan Karch,
Sergei Karpuk,
Fabian Kories,
Matthias Kretschmer,
Bernhard Lauss,
Tobias Reich,
Yuri Sobolev,
Norbert Trautmann
Abstract:
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the th…
▽ More
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the thermal bridge and the converter cup. The UCN yield was measured in a `standard' UCN storage bottle (stainless steel) with a volume of 32 litres outside the biological shield at the experimental area yielding UCN densities of 8.5 /cm$^3$; an increase by a factor of 3.5 compared to the former setup. The measured UCN storage curve is in good agreement with the predictions from a Monte Carlo simulation developed to model the source. The growth and formation of the solid deuterium converter during freeze-out are affected by the ortho/para ratio of the H$_2$ premoderator.
△ Less
Submitted 9 November, 2017; v1 submitted 23 June, 2017;
originally announced June 2017.
-
Comparison of ultracold neutron sources for fundamental physics measurements
Authors:
G. Bison,
M. Daum,
K. Kirch,
B. Lauss,
D. Ries,
P. Schmidt-Wellenburg,
G. Zsigmond,
T. Brenner,
P. Geltenbort,
T. Jenke,
O. Zimmer,
M. Beck,
W. Heil,
J. Kahlenberg,
J. Karch,
K. Ross,
K. Eberhardt,
C. Geppert,
S. Karpuk,
T. Reich,
C. Siemensen,
Y. Sobolev,
N. Trautmann
Abstract:
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently o…
▽ More
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a 'standard' UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.
△ Less
Submitted 26 October, 2016;
originally announced October 2016.
-
Precise Measurement of Magnetic Field Gradients from Free Spin Precession Signals of $^{3}$He and $^{129}$Xe Magnetometers
Authors:
F. Allmendinger,
P. Blümler,
M. Doll,
O. Grasdijk,
W. Heil,
K. Jungmann,
S. Karpuk,
H. -J. Krause,
A. Offenhäusser,
M. Repetto,
U. Schmidt,
Yu. Sobolev,
K. Tullney,
L. Willmann,
S. Zimmer
Abstract:
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relax…
▽ More
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relaxation rates of both spin species are simultaneously monitored as magnetic field gradients are varied. For transverse relaxation times reaching 100 h, the residual longitudinal field gradient across the spin sample could be deduced to be$|\vec{\nabla}B_z|=(5.6 \pm 0.4)$ pT/cm. The method takes advantage of the high signal-to-noise ratio with which the decaying spin precession signal can be monitored that finally leads to the exceptional accuracy to determine magnetic field gradients at the sub pT/cm scale.
△ Less
Submitted 5 August, 2016;
originally announced August 2016.
-
Limit on Lorentz-Invariance- and CPT-Violating Neutron Spin Interactions Using a $^3$He-$^{129}$Xe Comagnetometer
Authors:
Fabian Allmendinger,
Ulrich Schmidt,
Werner Heil,
Sergej Karpuk,
Yuri Sobolev
Abstract:
We performed a search for a Lorentz-invariance- and CPT-violating coupling of the $^3$He and $^{129}$Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized $^3$He and $^{129}$Xe atoms using SQUID detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the L…
▽ More
We performed a search for a Lorentz-invariance- and CPT-violating coupling of the $^3$He and $^{129}$Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized $^3$He and $^{129}$Xe atoms using SQUID detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field $\tilde{b}^n_{\bot}< 8.4 \cdot 10^{-34}$ GeV (68\% C.L.). Furthermore, this technique was modified to search for an electric dipole moment (EDM) of $^{129}$Xe.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
The magnetic shielding for the neutron decay spectrometer aSPECT
Authors:
Gertrud Konrad,
Fidel Ayala Guardia,
Stefan Baeßler,
Michael Borg,
Ferenc Glück,
Werner Heil,
Stefan Hiebel,
Raquel Munoz Horta,
Yury Sobolev
Abstract:
Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other ex…
▽ More
Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for aSPECT must manage with limited space. In addition, we must ensure that the additional magnetic forces on the magnet coils are not destructive. In order to determine the most suitable geometry for the magnetic shielding for aSPECT, we simulated a variety of possible geometries and combinations of shielding materials of non-linear permeability. The results of our simulations were checked through magnetic field measurements both with Hall and nuclear magnetic resonance probes. The experimental data are in good agreement with the simulated values: The mean deviation from the simulated exterior magnetic field is (-1.7+/-4.8)%. However, in the two critical regions, the internal magnetic field deviates by 0.2% respectively <1E-4 from the simulated values.
△ Less
Submitted 5 May, 2014;
originally announced May 2014.
-
New limit on Lorentz and CPT violating neutron spin interactions using a free precession 3He-129Xe co-magnetometer
Authors:
F. Allmendinger,
W. Heil,
S. Karpuk,
W. Kilian,
A. Scharth,
U. Schmidt,
A. Schnabel,
Yu. Sobolev,
K. Tullney
Abstract:
We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor fields which permeate the universe. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low…
▽ More
We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor fields which permeate the universe. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low-noise magnetic flux detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field interacting with the spin of the bound neutron bn< 6.7*10^-34 GeV (68% C.L.). Our result improves our previous limit (data measured in 2009) by a factor of 30 and the world's best limit by a factor of 5.
△ Less
Submitted 11 December, 2013;
originally announced December 2013.
-
V2:Performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz
Authors:
J. Karch,
Yu. Sobolev,
M. Beck,
K. Eberhardt,
G. Hampel,
W. Heil,
R. Kieser,
T. Reich,
N. Trautmann,
M. Ziegner
Abstract:
The performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz with a maximum peak energy of 10 MJ is described. The solid deuterium converter with a volume of V=160 cm3 (8 mol), which is exposed to a thermal neutron fluence of 4.5x10^13 n/cm2, delivers up to 550 000 UCN per pulse outside of the biological shield at the experimental area. UCN densities of ~ 10/c…
▽ More
The performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz with a maximum peak energy of 10 MJ is described. The solid deuterium converter with a volume of V=160 cm3 (8 mol), which is exposed to a thermal neutron fluence of 4.5x10^13 n/cm2, delivers up to 550 000 UCN per pulse outside of the biological shield at the experimental area. UCN densities of ~ 10/cm3 are obtained in stainless steel bottles of V ~ 10 L resulting in a storage efficiency of ~20%. The measured UCN yields compare well with the predictions from a Monte Carlo simulation developed to model the source and to optimize its performance for the upcoming upgrade of the TRIGA Mainz into a user facility for UCN physics.
△ Less
Submitted 17 January, 2014; v1 submitted 21 August, 2013;
originally announced August 2013.
-
Probing Physics beyond the Standard Model with He/Xe clock comparison experiments
Authors:
U. Schmidt,
F. Allmendinger,
W. Heil,
S. Karpuk,
A. Scharth,
Y. Sobolev,
K. Tullney,
S. Zimmer
Abstract:
The comparison of the free precession of co-located 3He-129Xe spins (clock comparison) enables us to search for very tiny nonmagnetic spin interactions. With our setup we could establish new limits for Lorentz invariance violating interactions of spins with a relic background field which permeates the Universe and points in a preferred direction in space.
The comparison of the free precession of co-located 3He-129Xe spins (clock comparison) enables us to search for very tiny nonmagnetic spin interactions. With our setup we could establish new limits for Lorentz invariance violating interactions of spins with a relic background field which permeates the Universe and points in a preferred direction in space.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
Using a rotating magnetic guiding field for the 3He-129Xe-Comagnetometer
Authors:
F. Allmendinger,
U. Schmidt,
W. Heil,
S. Karpuk,
A. Scharth,
Y. Sobolev,
K. Tullney,
S. Zimmer
Abstract:
Our search for non-magnetic spin-dependent interactions is based on the measurement of free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT. We report on our approach to perform an adiabatic rotation of the guiding field that allows us to modulate possible non-magnetic spin-dependent interactions and to find an optimization procedure…
▽ More
Our search for non-magnetic spin-dependent interactions is based on the measurement of free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT. We report on our approach to perform an adiabatic rotation of the guiding field that allows us to modulate possible non-magnetic spin-dependent interactions and to find an optimization procedure for long transverse relaxation times T2* both for Helium and Xenon.
△ Less
Submitted 19 July, 2013;
originally announced July 2013.
-
An Improved Search for the Neutron Electric Dipole Moment
Authors:
M. Burghoff,
A. Schnabel,
G. Ban,
T. Lefort,
Y. Lemiere,
O. Naviliat-Cuncic,
E. Pierre,
G. Quemener,
J. Zejma,
M. Kasprzak,
P. Knowles,
A. Weis,
G. Pignol,
D. Rebreyend,
S. Afach,
G. Bison,
J. Becker,
N. Severijns,
S. Roccia,
C. Plonka-Spehr,
J. Zennerz,
W. Heil,
H. C. Koch,
A. Kraft,
T. Lauer
, et al. (12 additional authors not shown)
Abstract:
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved…
▽ More
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Authors:
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
P. Fierlinger,
B. Franke,
E. Gutsmiedl,
W. Heil,
R. Henneck,
M. Horras,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Kraft,
A. Knecht,
P. Knowles,
A. Kozela,
T. Lauer,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (16 additional authors not shown)
Abstract:
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in…
▽ More
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
△ Less
Submitted 30 September, 2010;
originally announced September 2010.
-
Ultra-sensitive magnetometry based on free precession of nuclear spins
Authors:
C. Gemmel,
W. Heil,
K. Lenz,
Ch. Ludwig,
K. Thulley,
Yu. Sobolev,
M. Burghoff,
S. Knappe-Grueneberg,
W. Kilian,
W. Mueller,
A. Schnabel,
F. Seifert,
L. Trahms,
St. Baessler
Abstract:
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in…
▽ More
We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized 3He or 129Xe samples with a SQUID as magnetic flux detector. The device will be employed to control fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron as well as in a new type of 3He/129Xe clock comparison experiment which should be sensitive to a sidereal variation of the relative spin precession frequency. Characteristic spin precession times T_2 of up to 60h could be measured. In combination with a signal-to-noise ratio of > 5000:1, this leads to a sensitivity level of deltaB= 1fT after an integration time of 220s and to deltaB= 10^(-4)fT after one day. Even in that sensitivity range, the magnetometer performance is statistically limited, and noise sources inherent to the magnetometer are not limiting. The reason is that free precessing 3He (129Xe) nuclear spins are almost completely decoupled from the environment. That makes this type of magnetometer in particular attractive for precision field measurements where a long-term stability is required.
△ Less
Submitted 22 May, 2009;
originally announced May 2009.