-
Small Leidenfrost droplet dynamics
Authors:
Benjamin Sobac,
Alexey Rednikov,
Pierre Colinet
Abstract:
An isolated Leidenfrost droplet levitating over its own vapor above a superheated flat substrate is considered theoretically, the superheating for water being up to several hundred degrees above the boiling temperature. The focus is on the limit of small, practically spherical droplets of several tens of micrometers or less. This may occur when the liquid is sprayed over a hot substrate, or just b…
▽ More
An isolated Leidenfrost droplet levitating over its own vapor above a superheated flat substrate is considered theoretically, the superheating for water being up to several hundred degrees above the boiling temperature. The focus is on the limit of small, practically spherical droplets of several tens of micrometers or less. This may occur when the liquid is sprayed over a hot substrate, or just be a late life stage of an initially large Leidenfrost droplet. A rigorous numerically-assisted analysis is carried out within verifiable assumptions such as quasi-stationarities and small Reynolds/Péclet numbers. It is considered that the droplet is surrounded by its pure vapor. Simple fitting formulas of our numerical data for the forces and evaporation rates are preliminarily obtained, all respecting the asymptotic behaviors (also investigated) in the limits of small and large levitation heights. They are subsequently used within a system of ODEs to study the droplet dynamics and take-off (drastic height increase as the droplet vaporizes). A previously known quasi-stationary inverse-square root law for the droplet height as a function of its radius (at the root of the take-off) is recovered, although we point out different prefactors in the two limits. Deviations of a dynamic nature therefrom are uncovered as the droplet radius further decreases due to evaporation, improving the agreement with experiment. Furthermore, we reveal that, if initially large enough, the droplets vanish at a universal finite height (just dependent on the superheat and fluid properties). Scalings in various distinguished cases are obtained in the way.
△ Less
Submitted 26 September, 2024;
originally announced September 2024.
-
Water and heat exchanges in mammalian lungs
Authors:
Benoit Haut,
Cyril Karamaoun,
Benjamin Mauroy,
Benjamin Sobac
Abstract:
A secondary function of the mammals' respiratory system is during inspiration to heat the air to body temperature and to saturate it with water before it reaches the alveoli. Relying on a mathematical model, we comprehensively analyze this function, considering all the terrestrial mammals (spanning six orders of magnitude of the body mass, $M$) and focusing on the sole contribution of the lungs to…
▽ More
A secondary function of the mammals' respiratory system is during inspiration to heat the air to body temperature and to saturate it with water before it reaches the alveoli. Relying on a mathematical model, we comprehensively analyze this function, considering all the terrestrial mammals (spanning six orders of magnitude of the body mass, $M$) and focusing on the sole contribution of the lungs to this air conditioning. The results highlight significant differences between the small and the large mammals, as well as between rest and effort, regarding the spatial distribution of heat and water exchanges in the lungs, and in terms of regime of mass transfer taking place in the lumen of the airways. Interestingly, the results show that the mammalian lungs appear to be designed just right to fully condition the air at maximal effort: all generations of the bronchial region of the lungs are mobilized for this purpose. For mammals with a mass above a certain threshold ($\simeq 5$ kg at rest and $\simeq 50$ g at maximal effort), it appears that the maximal value of this evaporation rate scales as $M^{-1/8}$ at rest and $M^{-1/16}$ at maximal effort and that around 40\% (at rest) or 50\% (at maximal effort) of the water/heat extracted from the lungs during inspiration is returned to the bronchial mucosa during expiration, independently of the mass, due to a subtle coupling between different phenomena. This last result implies that, above these thresholds, the amounts of water and heat extracted from the lungs by the ventilation scale with the mass such as the ventilation rate (i.e. as $M^{3/4}$ at rest and $M^{7/8}$ at maximal effort). Finally, it is worth mentioning that these amounts appear to remain limited, but not negligible when compared to relevant global quantities, even at maximal effort (4-6\%).
△ Less
Submitted 26 November, 2022;
originally announced November 2022.
-
Beads, bubbles and drops in microchannels: stability of centered position and equilibrium velocity
Authors:
Jean Cappello,
Javier Rivero-Rodrìguez,
Youen Vitry,
Adrien Dewandre,
Benjamin Sobac,
Benoit Scheid
Abstract:
Understand and predict the dynamics of dispersed micro-objects in microfluidics is crucial in numerous natural, industrial and technological situations. In this paper, we experimentally characterized the equilibrium velocity $V$ and lateral position $\varepsilon$ of various dispersed micro-objects such as beads, bubbles and drops, in a cylindrical microchannel over an unprecedent wide range of par…
▽ More
Understand and predict the dynamics of dispersed micro-objects in microfluidics is crucial in numerous natural, industrial and technological situations. In this paper, we experimentally characterized the equilibrium velocity $V$ and lateral position $\varepsilon$ of various dispersed micro-objects such as beads, bubbles and drops, in a cylindrical microchannel over an unprecedent wide range of parameters. By systematically varying the dimensionless object size ($d \in [0.1; 1]$), the viscosity ratio ($λ\in [10^{-2}; \infty[$), the density ratio ($\varphi \in [10^{-3}; 2]$), the Reynolds number ($\Re \in [10^{-2}; 10^2]$), and the capillary number ($\text{Ca} \in [10^{-3}; 0.3]$), we offer a general study exploring various dynamics from the nonderformable viscous regime to the deformable visco-inertio-capillary regime, thus enabling to highlight the sole and combined roles of inertia and capillary effects on lateral migration. The experiments are compared and well-agree with a steady 3D Navier-Stokes model for incompressible two-phase fluids including both the effects of inertia and possible interfacial deformations. This model enables to rationalize the experiments and to provide an exhaustive parametric analysis on the influence of the main parameters of the problem, mainly on two aspects: the stability of the centered position and the velocity of the dispersed object. Interestingly, we propose a useful correlation for the object velocity $V$ as functions of the $d$, $\varepsilon$ and $λ$, obtained in the $\text{Re}=\text{Ca}=0$ limit, but actually valid for a larger range of values of $\text{Re}$ and $\text{Ca}$ in the linear regimes.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Raydrop : a universal droplet generator based on a non-embedded co-flow-focusing
Authors:
Adrien Dewandre,
Javier Rivero-Rodriguez,
Youen Vitry,
Benjamin Sobac,
Benoit Scheid
Abstract:
Most commercial microfluidic droplet generators rely on the planar flow-focusing configuration implemented in polymer or glass chips. The planar geometry, however, suffers from many limitations and drawbacks, such as the need of specific coatings or the use of dedicated surfactants, depending on the fluids in play. On the contrary, and thanks to their axisymmetric geometry, glass capillary-based d…
▽ More
Most commercial microfluidic droplet generators rely on the planar flow-focusing configuration implemented in polymer or glass chips. The planar geometry, however, suffers from many limitations and drawbacks, such as the need of specific coatings or the use of dedicated surfactants, depending on the fluids in play. On the contrary, and thanks to their axisymmetric geometry, glass capillary-based droplet generators are a priori not fluid-dependent. Nevertheless, they have never reached the market because their assembly requires art-dependent and not scalable fabrication techniques. Here we present a new device, called Raydrop, based on the alignment of two capillaries immersed in a pressurized chamber containing the continuous phase. The dispersed phase exits one of the capillaries through a 3D-printed nozzle, placed in front of the extraction capillary for collecting the droplets. This non-embedded implementation of an axisymmetric flow-focusing is referred to {\it co-flow-focusing}. Experimental results demonstrate the universality of the device in terms of the variety of fluids that can be emulsified, as well as the range of droplet radii that can be obtained, without neither the need of surfactant nor coating. Additionally, numerical computations of the Navier-Stokes equations based on the quasi-steadiness assumption are shown to correctly predict the droplet radius in the dripping regime and the dripping-jetting transition when varying the geometrical and fluid parameters. The monodispersity ensured by the dripping regime, the robustness of the fabrication technique, the optimization capabilities from the numerical modeling and the universality of the configuration confer to the Raydrop technology a very high potential in the race towards high-throughput droplet generation processes.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
Allometric scaling of heat and water exchanges in the mammals' lung
Authors:
Benjamin Sobac,
Cyril Karamaoun,
Benoit Haut,
Benjamin Mauroy
Abstract:
Mammals have a high metabolism that produces heat proportionally to the power 3/4 of their mass at rest. Any excess of heat has to be dissipated in the surrounding environment to prevent overheating. Most of that dissipation occurs through the skin, but the efficiency of that mechanism decreases with the animal's mass. The role of the other mechanisms for dissipating heat is then raised, more part…
▽ More
Mammals have a high metabolism that produces heat proportionally to the power 3/4 of their mass at rest. Any excess of heat has to be dissipated in the surrounding environment to prevent overheating. Most of that dissipation occurs through the skin, but the efficiency of that mechanism decreases with the animal's mass. The role of the other mechanisms for dissipating heat is then raised, more particularly the one linked to the lung that forms a much larger surface area than the skin. The dissipation occurring in the lung is however often neglected, even though there exists no real knowledge of its dynamics, hidden by the complexity of the organ's geometry and of the physics of the exchanges. Here we show, based on an original and analytical model of the exchanges in the lung, that all mammals, independently of their mass, dissipate through their lung the same proportion of the heat they produced, about 6-7 %. We found that the heat dissipation in mammals' lung is driven by a number, universal among mammals, that arises from the dynamics of the temperature of the bronchial mucosa. We propose a scenario to explain how evolution might have tuned the lung for heat exchanges. Furthermore, our analysis allows to define the pulmonary heat and water diffusive capacities. We show in the human case that these capacities follow closely the oxygen consumption. Our work lays the foundations for more detailed analysis of the heat exchanges occurring in the lung. Future studies should focus on refining our understanding of the universal number identified. In an ecological framework, our analysis paves the way to a better understanding of the mammals' strategies for thermoregulation and of the effect of warming environments on mammals' metabolism.
△ Less
Submitted 15 December, 2019; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Asymptotic theory for a Leidenfrost drop on a liquid pool
Authors:
Michiel A. J. van Limbeek,
Benjamin Sobac,
Alexey Rednikov,
Pierre Colinet,
Jacco H. Snoeijer
Abstract:
Droplets can be levitated by their own vapour when placed onto a superheated plate (the Leidenfrost effect). It is less known that the Leidenfrost effect can likewise be observed over a liquid pool (superheated with respect to the drop), which is the study case here. Emphasis is placed on an asymptotic analysis in the limit of small evaporation numbers, which proves to be a realistic one indeed fo…
▽ More
Droplets can be levitated by their own vapour when placed onto a superheated plate (the Leidenfrost effect). It is less known that the Leidenfrost effect can likewise be observed over a liquid pool (superheated with respect to the drop), which is the study case here. Emphasis is placed on an asymptotic analysis in the limit of small evaporation numbers, which proves to be a realistic one indeed for not so small drops. The global shapes are found to resemble "superhydrophobic drops" that follow from the equilibrium between capillarity and gravity. However, the morphology of the thin vapour layer between the drop and the pool is very different from that of classical Leidenfrost drops over a flat rigid substrate, and exhibits different scaling laws. We determine analytical expressions for the vapour thickness as a function of temperature and material properties, which are confirmed by numerical solutions. Surprisingly, we show that deformability of the pool suppresses the chimney instability of Leidenfrost drops.
△ Less
Submitted 30 May, 2018;
originally announced May 2018.
-
Leidenfrost drops on a heated liquid pool
Authors:
Laurent Maquet,
Benjamin Sobac,
Baptiste Darbois-Texier,
Alexis Duchesne,
Martin Brandenbourger,
Alexey Rednikov,
Pierre Colinet,
Stéphane Dorbolo
Abstract:
We show that a volatile liquid drop placed at the surface of a non-volatile liquid pool warmer than the boiling point of the drop can experience a Leidenfrost effect even for vanishingly small superheats. Such an observation points to the importance of the substrate roughness, negligible in the case considered here, in determining the threshold Leidenfrost temperature. A theoretical model based on…
▽ More
We show that a volatile liquid drop placed at the surface of a non-volatile liquid pool warmer than the boiling point of the drop can experience a Leidenfrost effect even for vanishingly small superheats. Such an observation points to the importance of the substrate roughness, negligible in the case considered here, in determining the threshold Leidenfrost temperature. A theoretical model based on the one proposed by Sobac et al. [Phys. Rev. E 90, 053011 (2014)] is developed in order to rationalize the experimental data. The shapes of the drop and of the substrate are analyzed. The model notably provides scalings for the vapor film thickness. For small drops, these scalings appear to be identical to the case of a Leidenfrost drop on a solid substrate. For large drops, in contrast, they are different and no evidence of chimney formation has been observed either experimentally or theoretically in the range of drop sizes considered in this study. Concerning the evaporation dynamics, the radius is shown to decrease linearly with time whatever the drop size, which differs from the case of a Leidenfrost drop on a solid substrate. For high superheats, the characteristic lifetime of the drops versus the superheat follows a scaling law that is derived from the model but, at low superheats, it deviates from this scaling by rather saturating.
△ Less
Submitted 21 March, 2016; v1 submitted 18 March, 2016;
originally announced March 2016.
-
Patterns Formation in Drying Drops of Blood
Authors:
D. Brutin,
B. Sobac,
B. Loquet,
J. Sampol
Abstract:
The drying of a drop of human blood exhibits coupled physical mechanisms, such as Marangoni flow, evaporation and wettability. The final stage of a whole blood drop evaporation reveals regular patterns with a good reproducibility for a healthy person. Other experiments on anaemic and hyperlipidemic people were performed, and different patterns were revealed. The flow motion inside the blood drop i…
▽ More
The drying of a drop of human blood exhibits coupled physical mechanisms, such as Marangoni flow, evaporation and wettability. The final stage of a whole blood drop evaporation reveals regular patterns with a good reproducibility for a healthy person. Other experiments on anaemic and hyperlipidemic people were performed, and different patterns were revealed. The flow motion inside the blood drop is observed and analyzed with the use of a digital camera: the influence of the red blood cells (RBCs) motion is revealed at the drop periphery as well as its consequences on the final stage of drying. The mechanisms which lead to the final pattern of the dried blood drops are presented and explained on the basis of fluid mechanics in conjunction with the principles of haematology. The blood drop evaporation process is evidenced to be driven only by Marangoni flow. The same axisymetric pattern formation is observed, and can be forecast for different blood drop diameters. The evaporation mass flux can be predicted with a good agreement, assuming only the knowledge of the colloids mass concentration.
△ Less
Submitted 12 October, 2010;
originally announced October 2010.