Testing a large size triple GEM detector for the first station of the CBM-Muon Chambers with a high-intensity gamma source at GIF++ under large-area illumination
Authors:
Apar Agarwal,
Souvik Chattopadhay,
Pawan Kumar Sharma,
Anand Kumar Dubey,
Jogender Saini,
Vikas Singhal,
Vinod Negi,
Ekata Nandy,
Chandrasekhar Ghosh,
David Emschermann
Abstract:
The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime choices for the upcoming Compressed Baryonic Matter (CBM) experiment at the Facility of Antiproton and Ion Research, Germany. However, operating them under these…
▽ More
The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime choices for the upcoming Compressed Baryonic Matter (CBM) experiment at the Facility of Antiproton and Ion Research, Germany. However, operating them under these demanding conditions requires a systemic study at the highest incident particle flux. To this end, we have conducted extensive tests on a real-size triple GEM detector module with the high-intensity gamma flux using the Cs-137 source at the upgraded Gamma Irradiation Facility (GIF++) at Conseil Européen pour la Recherche Nucléaire (CERN). The detector response, particularly regarding the gain and efficiency of muon detection, was studied extensively with and without a gamma source in a free-streaming mode using self-triggered electronics. This configuration will be necessary for the CBM experiment since it will observe unprecedented event rates of about 10 MHz for Au-Au collisions. The analysis reveals an alignment between the expected and observed value of gain and efficiency with an increasing intensity of gamma flux at the operating voltage. The test results demonstrate that the large-size GEM detector prototype can handle elevated gamma rates of approximately 17.25 MHz/cm2 without significantly impacting its performance or suffering irreversible damage.
△ Less
Submitted 25 April, 2025;
originally announced April 2025.
-
Commissioning and testing of pre-series triple GEM prototypes for CBM-MuCh in the mCBM experiment at the SIS18 facility of GSI
Authors:
A. Kumar,
A. Agarwal,
S. Chatterjee,
S. Chattopadhyay,
A. K. Dubey,
C. Ghosh,
E. Nandy,
V. Negi,
S. K. Prasad,
J. Saini,
V. Singhal,
O. Singh,
G. Sikder,
J. de Cuveland,
I. Deppner,
D. Emschermann,
V. Friese,
J. Frühauf,
M. Gumiński,
N. Herrmann,
D. Hutter,
M. Kis,
J. Lehnert,
P. -A. Loizeau,
C. J. Schmidt
, et al. (3 additional authors not shown)
Abstract:
Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in Darmstadt/Germany. The GEM detectors have been designed to take data at an unprecedented interaction rate (up to 10 MHz) in nucleus-nucleus collisions in CBM at FAIR. Real-size trapezoidal modules have been installed in…
▽ More
Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in Darmstadt/Germany. The GEM detectors have been designed to take data at an unprecedented interaction rate (up to 10 MHz) in nucleus-nucleus collisions in CBM at FAIR. Real-size trapezoidal modules have been installed in the mCBM experiment and tested in nucleus-nucleus collisions at the SIS18 beamline of GSI as a part of the FAIR Phase-0 program. In this report, we discuss the design, installation, commissioning, and response of these GEM modules in detail. The response has been studied using the free-streaming readout electronics designed for the CBM-MuCh and CBM-STS detector system. In free-streaming data, the first attempt on an event building based on the timestamps of hits has been carried out, resulting in the observation of clear spatial correlations between the GEM modules in the mCBM setup for the first time. Accordingly, a time resolution of $\sim$15\,ns have been obtained for the GEM detectors.
△ Less
Submitted 12 August, 2021;
originally announced August 2021.
-
Development and implementation of a time-based signal generation scheme for the Muon Chamber simulation of the CBM experiment at FAIR
Authors:
V. Singhal,
S. Chatterjee,
V. Friese,
S. Chattopadhyay
Abstract:
The Compressed Baryonic Matter~(CBM) experiment in the upcoming Facility for Antiproton and Ion Research~(FAIR), designed to take data in nuclear collisions at very high interaction rates of up to 10 MHz, will employ a free-streaming data acquisition with self-triggered readout electronics, without any hardware trigger. A simulation framework with a realistic digitization of the detectors in the m…
▽ More
The Compressed Baryonic Matter~(CBM) experiment in the upcoming Facility for Antiproton and Ion Research~(FAIR), designed to take data in nuclear collisions at very high interaction rates of up to 10 MHz, will employ a free-streaming data acquisition with self-triggered readout electronics, without any hardware trigger. A simulation framework with a realistic digitization of the detectors in the muon chamber (MuCh) subsystem in CBM has been developed to provide a realistic simulation of the time-stamped data stream. In this article, we describe the implementation of the free-streaming detector simulation and the basic data related effects on the detector with respect to the interaction rate.
△ Less
Submitted 24 April, 2021;
originally announced April 2021.
-
Investigation of heterogeneous computing platforms for real-time data analysis in the CBM experiment
Authors:
V. Singhal,
S. Chattopadhyay,
V. Friese
Abstract:
Future experiments in high-energy physics will pose stringent requirements to computing, in particular to real-time data processing. As an example, the CBM experiment at FAIR Germany intends to perform online data selection exclusively in software, without using any hardware trigger, at extreme interaction rates of up to 10 MHz. In this article, we describe how heterogeneous computing platforms, G…
▽ More
Future experiments in high-energy physics will pose stringent requirements to computing, in particular to real-time data processing. As an example, the CBM experiment at FAIR Germany intends to perform online data selection exclusively in software, without using any hardware trigger, at extreme interaction rates of up to 10 MHz. In this article, we describe how heterogeneous computing platforms, Graphical Processing Units (GPUs) and CPUs, can be used to solve the associated computing problems on the example of the first-level event selection process sensitive to J/ψ decays using muon detectors. We investigate and compare pure parallel computing paradigms (Posix Thread, OpenMP, MPI) and heterogeneous parallel computing paradigms (CUDA, OpenCL) on both CPU and GPU architectures and demonstrate that the problem under consideration can be accommodated with a moderate deployment of hardware resources, provided their compute power is made optimal use of. In addition, we compare OpenCL and pure parallel computing paradigms on CPUs and show that OpenCL can be considered as a single parallel paradigm for all hardware resources.
△ Less
Submitted 5 February, 2020; v1 submitted 29 October, 2018;
originally announced October 2018.