Microwave calibration of qubit drive line components at millikelvin temperatures
Authors:
Slawomir Simbierowicz,
Volodymyr Y. Monarkha,
Suren Singh,
Nizar Messaoudi,
Philip Krantz,
Russell E. Lake
Abstract:
Systematic errors in qubit state preparation arise due to non-idealities in the qubit control lines such as impedance mismatch. Using a data-based methodology of short-open-load calibration at a temperature of 30 mK, we report calibrated 1-port scattering parameter data of individual qubit drive line components. At 5~GHz, cryogenic return losses of a 20-dB-attenuator, 10-dB-attenuator, a 230-mm-lo…
▽ More
Systematic errors in qubit state preparation arise due to non-idealities in the qubit control lines such as impedance mismatch. Using a data-based methodology of short-open-load calibration at a temperature of 30 mK, we report calibrated 1-port scattering parameter data of individual qubit drive line components. At 5~GHz, cryogenic return losses of a 20-dB-attenuator, 10-dB-attenuator, a 230-mm-long 0.86-mm silver-plated cupronickel coaxial cable, and a 230-mm-long 0.86-mm NbTi coaxial cable were found to be 35$^{+3}_{-2}$ dB, 33$^{+3}_{-2}$ dB, 34$^{+3}_{-2}$ dB, and 29$^{+2}_{-1}$ dB respectively. For the same frequency, we also extract cryogenic insertion losses of 0.99$^{+0.04}_{-0.04}$ dB and 0.02$^{+0.04}_{-0.04}$ dB for the coaxial cables. We interpret the results using a master equation simulation of all XY gates performed on a single qubit. For example, we simulate a sequence of two 5 ns gate pulses (X & Y) through a 2-element Fabry-Pérot cavity with 276-mm path length directly preceding the qubit, and establish that the return loss of its reflective elements must be >9.7 dB (> 14.7 dB) to obtain 99.9 % (99.99 %) gate fidelity.
△ Less
Submitted 29 January, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.
-
Characterizing cryogenic amplifiers with a matched temperature-variable noise source
Authors:
Slawomir Simbierowicz,
Visa Vesterinen,
Joshua Milem,
Aleksi Lintunen,
Mika Oksanen,
Leif Roschier,
Leif Grönberg,
Juha Hassel,
David Gunnarsson,
Russell E. Lake
Abstract:
We present a cryogenic microwave noise source with a characteristic impedance of 50 $Ω$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that in…
▽ More
We present a cryogenic microwave noise source with a characteristic impedance of 50 $Ω$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as $680^{+20}_{-200}$ mK at 5.7 GHz corresponding to $1.5^{+0.1}_{-0.7}$ excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.
△ Less
Submitted 25 February, 2021; v1 submitted 7 September, 2020;
originally announced September 2020.
-
Nanobolometer with Ultralow Noise Equivalent Power
Authors:
R. Kokkoniemi,
J. Govenius,
V. Vesterinen,
R. E. Lake,
A. M. Gunyho,
K. Y. Tan,
S. Simbierowicz,
L. Grönberg,
J. Lehtinen,
M. Prunnila,
J. Hassel,
O. -P. Saira,
M. Möttönen
Abstract:
Since the introduction of bolometers more than a century ago, they have been applied in a broad spectrum of contexts ranging from security and the construction industry to particle physics and astronomy. However, emerging technologies and missions call for faster bolometers with lower noise. Here, we demonstrate a nanobolometer that exhibits roughly an order of magnitude lower noise equivalent pow…
▽ More
Since the introduction of bolometers more than a century ago, they have been applied in a broad spectrum of contexts ranging from security and the construction industry to particle physics and astronomy. However, emerging technologies and missions call for faster bolometers with lower noise. Here, we demonstrate a nanobolometer that exhibits roughly an order of magnitude lower noise equivalent power, $20\textrm{ zW}/\sqrt{\textrm{Hz}}$, than previously reported for any bolometer. Importantly, it is more than an order of magnitude faster than other low-noise bolometers, with a time constant of 30 $μ$s at $60\textrm{ zW}/\sqrt{\textrm{Hz}}$. These results suggest a calorimetric energy resolution of $0.3\textrm{ zJ}=h\times 0.4$ THz with a time constant of 30 $μ$s. Thus the introduced nanobolometer is a promising candidate for future applications requiring extreme precision and speed such as those in astronomy and terahertz photon counting.
△ Less
Submitted 26 June, 2018; v1 submitted 25 June, 2018;
originally announced June 2018.
-
Flux-driven Josephson parametric amplifier for sub-GHz frequencies fabricated with side-wall passivated spacer junction technology
Authors:
Slawomir Simbierowicz,
Visa Vesterinen,
Leif Grönberg,
Janne Lehtinen,
Mika Prunnila,
Juha Hassel
Abstract:
We present experimental results on a Josephson parametric amplifier tailored for readout of ultra-sensitive thermal microwave detectors. In particular, we discuss the impact of fabrication details on the performance. We show that the small volume of deposited dielectric materials enabled by the side-wall passivated spacer niobium junction technology leads to robust operation across a wide range of…
▽ More
We present experimental results on a Josephson parametric amplifier tailored for readout of ultra-sensitive thermal microwave detectors. In particular, we discuss the impact of fabrication details on the performance. We show that the small volume of deposited dielectric materials enabled by the side-wall passivated spacer niobium junction technology leads to robust operation across a wide range of operating temperatures up to 1.5 K. The flux-pumped amplifier has gain in excess of 20 dB in three-wave mixing and its center frequency is tunable between 540 MHz and 640 MHz. At 600 MHz, the amplifier adds 105 mK $\pm$ 9 mK of noise, as determined with the hot/cold source method. Phase-sensitive amplification is demonstrated with the device.
△ Less
Submitted 18 May, 2018;
originally announced May 2018.
-
Side-wall spacer passivated sub-um Josephson junction fabrication process
Authors:
Leif Grönberg,
Mikko Kiviranta,
Visa Vesterinen,
Janne Lehtinen,
Slawomir Simbierowicz,
Juho Luomahaara,
Mika Prunnila,
Juha Hassel
Abstract:
We present a structure and a fabrication method for superconducting tunnel junctions down to the dimensions of 200 nm using i-line UV lithography. The key element is a side-wall-passivating spacer structure (SWAPS) which is shaped for smooth crossline contacting and low parasitic capacitance. The SWAPS structure enables formation of junctions with dimensions at or below the lithography-limited lin…
▽ More
We present a structure and a fabrication method for superconducting tunnel junctions down to the dimensions of 200 nm using i-line UV lithography. The key element is a side-wall-passivating spacer structure (SWAPS) which is shaped for smooth crossline contacting and low parasitic capacitance. The SWAPS structure enables formation of junctions with dimensions at or below the lithography-limited linewidth. An additional benefit is avoiding the excessive use of amorphous dielectric materials which is favorable in sub-Kelvin microwave applications often plagued by nonlinear and lossy dielectrics. We apply the structure to niobium trilayer junctions, and provide characterization results yielding evidence on wafer-scale scalability, and critical current density tuning in the range of 0.1 -- 3.0 kA/cm$^2$. We discuss the applicability of the junction process in the context of different applications, such as, SQUID magnetometers and Josephson parametric amplifiers.
△ Less
Submitted 9 March, 2018; v1 submitted 20 June, 2017;
originally announced June 2017.