-
From Offline to Inline Without Pain: A Practical Framework for Translating Offline MR Reconstructions to Inline Deployment Using the Gadgetron Platform
Authors:
Zihan Ning,
Yannick Brackenier,
Sarah McElroy,
Sara Neves Silva,
Lucilio Cordero-Grande,
Sam Rot,
Liane S. Canas,
Rebecca E Thornley,
David Leitão,
Davide Poccecai,
Andrew Cantell,
Rene Kerosi,
Anthony N Price,
Jon Cleary,
Donald J Tournier,
Jana Hutter,
Philippa Bridgen,
Pierluigi Di Cio,
Michela Cleri,
Inka Granlund,
Lucy Billimoria,
Yasmin Blunck,
Shaihan Malik,
Marc Modat,
Claire J Steves
, et al. (1 additional authors not shown)
Abstract:
Purpose: To develop and validate a practical framework to overcome common issues in inline deployment of established offline MR reconstruction, including (1) delay from lengthy reconstructions, (2) limited support for multi-scan input reconstructions, (3) the need to adapt scripts for different raw formats, and (4) limited guidance and experience in retaining scanner reconstructions and applying s…
▽ More
Purpose: To develop and validate a practical framework to overcome common issues in inline deployment of established offline MR reconstruction, including (1) delay from lengthy reconstructions, (2) limited support for multi-scan input reconstructions, (3) the need to adapt scripts for different raw formats, and (4) limited guidance and experience in retaining scanner reconstructions and applying scanner-based post-processing to custom outputs. Methods: The framework builds upon the Gadgetron platform and includes: (1) an input converter to transform ISMRMRD format raw into a Siemens format raw structure, facilitating reuse of existing code; (2) an asynchronous trigger-and-retrieve mechanism enabling long reconstructions without delaying scanner processes; (3) resource-aware scheduling for parallel execution; (4) integrated file management to support multi-scan inputs; and (5) preservation of scanner-based reconstructions and post-processing. The framework was validated on 2 Siemens scanners for SENSE, AlignedSENSE, and NUFFT reconstructions, and in a large-cohort study. Results: Minimum code modification for inline deployment has been shown, and all reconstructions were successfully executed inline without disrupting scanner workflows. Images were retrieved via automated or retro-reconstruction, with scanner-based post-processing applied to custom outputs. Multi-scan input reconstructions were executed using GPU-aware scheduling, confirming feasibility for routine and large-scale applications. In 480 consecutive examinations, inline reconstructions were retrieved in 99% of cases without disruptions. Conclusion: The framework lowers the technical barrier to inline deployment of offline reconstructions, enabling robust, scalable, and post-processing-compatible integration. It is openly available with documentation and demonstration cases to support reproducibility and community adoption.
△ Less
Submitted 8 September, 2025;
originally announced September 2025.
-
Scanner-based real-time automated volumetry reporting of the fetus, amniotic fluid, placenta and umbilical cord for fetal MRI at 0.55T
Authors:
Sara Neves Silva,
Alena Uus,
Hadi Waheed,
Simi Bansal,
Kamilah St Clair,
Wendy Norman,
Jordina Aviles Verdera,
Daniel Cromb,
Tomas Woodgate,
Milou van Poppel,
Johannes K Steinweg,
Jacqueline Matthew,
Kuberan Pushparajah,
David Lloyd,
Vanessa Kyriakopoulou,
Dimitris Siasakos,
Anna David,
Joseph V Hajnal,
Lisa Story,
Mary A Rutherford,
Jana Hutter
Abstract:
Purpose: This work aims to enable real-time automated intra-uterine volumetric reporting and fetal weight estimation for fetal MRI, deployed directly on the scanner. Methods: A multi-region segmentation nnUNet was trained on 146 bSSFP images of 73 fetal subjects (coronal and axial orientations) for the parcellation of the fetal head, fetal body, placenta, amniotic fluid and umbilical cord from who…
▽ More
Purpose: This work aims to enable real-time automated intra-uterine volumetric reporting and fetal weight estimation for fetal MRI, deployed directly on the scanner. Methods: A multi-region segmentation nnUNet was trained on 146 bSSFP images of 73 fetal subjects (coronal and axial orientations) for the parcellation of the fetal head, fetal body, placenta, amniotic fluid and umbilical cord from whole uterus bSSFP stacks. A reporting tool was then developed to integrate the segmentation outputs into an automated report, providing volumetric measurements, fetal weight estimations, and z-score visualisations. The complete pipeline was subsequently deployed on a 0.55T MRI scanner, enabling real-time inference and fully automated reporting in the duration of the acquisition. Results: The segmentation pipeline was quantitatively and retrospectively evaluated on 36 stacks of 18 fetal subjects and demonstrated sufficient performance for all labels, with high scores (>0.98) for the fetus, placenta and amniotic fluid, and 0.91 for the umbilical cord. The prospective evaluation of the scanner deployment step was successfully performed on 50 cases, with the regional volumetric reports available directly on the scanner. Conclusions: This work demonstrated the feasibility of multi-regional intra-uterine segmentation, fetal weight estimation and automated reporting in real-time. This study provides a robust baseline solution for the integration of fully automated scanner-based measurements into fetal MRI reports.
△ Less
Submitted 7 July, 2025;
originally announced July 2025.
-
Real-time fetAl brain and placental T2* mapping at 0.55T low-field MRI (RAT)
Authors:
Jordina Aviles Verdera,
Sara Neves Silva,
Raphael Tomi-Tricot,
Megan Hall,
Lisa Story,
Shaihan J Malik,
Joseph V Hajnal,
Mary A Rutherford,
Jana Hutter
Abstract:
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 da…
▽ More
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 datasets for the fetal brain and a second one trained on 210 datasets for the placenta for automatic segmentation. T2* normal curves were obtained from 106 cases and prospective evaluation was performed on 10 cases between 35 and 39 weeks GA.
Results: Quantitative brain and placental T2* maps and centiles were available in all prospective cases within 30 seconds. The robustness of the method was shown with intra-scan repeats (mean difference 1.04+/-12.39 ms for fetal brain and -3.15+/-8.88 ms for placenta) and direct validation with vendor-processed offline results (mean difference 1.62+/-4.33 ms for fetal brain and 0.16+/-6.19 ms for placenta).
Discussion and Conclusion: Real-time available organ-specific quantitative information enables more personalized MR examinations, selection of the most pertinent sequences and thus the promise of reduced recalls and specific insights into tissue properties. The here enabled placental T2*, demonstrated in multiple recent studies to be a biomarker sensitive to a range of pregnancy complications, and fetal brain T2* will be explored in further studies in pregnancies with pre-eclampsia, growth restriction as a way of enabling future MR-guided fetal interventions.
△ Less
Submitted 25 September, 2024;
originally announced September 2024.
-
AutOmatic floW planning for fetaL MRI (OWL)
Authors:
Sara Neves Silva,
Tomas Woodgate,
Sarah McElroy,
Michela Cleri,
Kamilah St Clair,
Jordina Aviles Verdera,
Kelly Payette,
Alena Uus,
Lisa Story,
David Lloyd,
Mary A Rutherford,
Joseph V Hajnal,
Kuberan Pushparajah,
Jana Hutter
Abstract:
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landm…
▽ More
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landmarks for planning. The OWL pipeline was evaluated retrospectively in 10 datasets and prospectively in 7 fetal subjects (gestational ages between 36+3 and 39+3 weeks). The prospective cases were additionally manually planned to enable direct comparison both qualitatively, by scoring the planning quality, and quantitatively, by comparing the indexed flow measurements. OWL enabled real-time fully automatic planning of the 2D phase-contrast scans in all but one of the prospective participants. The fetal body localization achieved an overall Dice score of 0.94+-0.05 and the cardiac landmark detection accuracy was 5.77+-2.91 mm for the descending aorta, 4.32+-2.44 mm for the spine, and 4.94+-3.82 mm for the umbilical vein. For the prospective cases, overall planning quality was 2.73/4 for the automated scans, compared to 3.0/4 for manual planning, and the flow quantitative evaluation showed a mean difference of -1.8% (range -14.2% to 14.9%) by comparing the indexed flow measurements obtained from gated automatic and manual acquisitions. Real-time automated planning of 2D phase-contrast MRI was effectively accomplished for 2 major vessels of the fetal vasculature. While demonstrated here on 0.55T, the achieved method has wider implications, and training across multiple field strengths enables generalization. OWL thereby presents an important step towards extending access to this modality beyond specialised centres.
△ Less
Submitted 12 August, 2024;
originally announced August 2024.
-
Fully automated planning for anatomical fetal brain MRI on 0.55T
Authors:
Sara Neves Silva,
Sarah McElroy,
Jordina Aviles Verdera,
Kathleen Colford,
Kamilah St Clair,
Raphael Tomi-Tricot,
Alena Uus,
Valery Ozenne,
Megan Hall,
Lisa Story,
Kuberan Pushparajah,
Mary A Rutherford,
Joseph V Hajnal,
Jana Hutter
Abstract:
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from…
▽ More
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. Comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality and the resulting image quality was conducted. Results: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.21+-2.56 mm for the fetal eyes and 6.47+-3.23 for the cerebellum, planning quality was 2.44/3 (compared to 2.56/3 for manual planning) and diagnostic image quality was 2.14 compared to 2.07 for manual planning. Conclusions: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way towards simplifying the acquisition of fetal MRI thereby widening the availability of this modality in non-specialist centres.
△ Less
Submitted 18 January, 2024;
originally announced January 2024.