Image Reconstruction in Cone Beam Computed Tomography Using Controlled Gradient Sparsity
Authors:
Alexander Meaney,
Mikael A. K. Brix,
Miika T. Nieminen,
Samuli Siltanen
Abstract:
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray tomography (CBCT) has been limited so far, mainly due to heavy computational loads at clinically relevant 3D resolutions and the difficulty in choosing the regularizati…
▽ More
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray tomography (CBCT) has been limited so far, mainly due to heavy computational loads at clinically relevant 3D resolutions and the difficulty in choosing the regularization parameter. Here an efficient minimization algorithm is presented, combined with a dynamic parameter adjustment based on control theory. The result is a fully automatic 3D reconstruction method running in clinically acceptable time. The input on top of projection data and system geometry is desired degree of sparsity of the reconstruction. This can be determined from an atlas of CT scans, or alternatively used as an easily adjustable parameter with straightforward interpretation.
△ Less
Submitted 10 December, 2024;
originally announced December 2024.
-
Inner product regularized multi-energy X-ray tomography for material decomposition
Authors:
Salla-Maaria Latva-Äijö,
Filippo Zanetti,
Ari-Pekka Honkanen,
Simo Huotari,
Jacek Gondzio,
Matti Lassas,
Samuli Siltanen
Abstract:
Multi-energy X-ray tomography is studied for decomposing three materials using three X-ray energies and a classical energy-integrating detector. A novel regularization term comprises inner products between the material distribution functions, penalizing any overlap of different materials. The method is tested on real data measured of a phantom embedded with Na$_2$SeO$_3$, Na$_2$SeO$_4$, and elemen…
▽ More
Multi-energy X-ray tomography is studied for decomposing three materials using three X-ray energies and a classical energy-integrating detector. A novel regularization term comprises inner products between the material distribution functions, penalizing any overlap of different materials. The method is tested on real data measured of a phantom embedded with Na$_2$SeO$_3$, Na$_2$SeO$_4$, and elemental selenium. It is found that the two-dimensional distributions of selenium in different oxidation states can be mapped and distinguished from each other with the new algorithm. The results have applications in material science, chemistry, biology and medicine.
△ Less
Submitted 4 August, 2023;
originally announced September 2023.
-
Anatomical atlas of the upper part of the human head for electroencephalography and bioimpedance applications
Authors:
Fernando S Moura,
Roberto G Beraldo,
Leonardo A Ferreira,
Samuli Siltanen
Abstract:
Volume conductor problems in cerebral electrophysiology and bioimpedance do not have analytical solutions for nontrivial geometries and require a 3D model of the head and its electrical properties for solving the associated PDEs numerically. Ideally, the model should be made with patient-specific information. In clinical practice, this is not always the case and an average head model is often used…
▽ More
Volume conductor problems in cerebral electrophysiology and bioimpedance do not have analytical solutions for nontrivial geometries and require a 3D model of the head and its electrical properties for solving the associated PDEs numerically. Ideally, the model should be made with patient-specific information. In clinical practice, this is not always the case and an average head model is often used. Also, the electrical properties of the tissues might not be completely known due to natural variability. The objective of this work is to develop a 4D (3D+T) statistical anatomical atlas of the electrical properties of the upper part of the human head for cerebral electrophysiology and bioimpedance applications. The atlas is an important tool for in silico studies on cerebral circulation and electrophysiology that require statistically consistent data, e.g., machine learning, sensitivity analyses, and as a benchmark to test inverse problem solvers. The atlas was constructed based on MRI images of human individuals and comprises the electrical properties of the main internal structures and can be adjusted for specific electrical frequencies. The proposed atlas also comprises a time-varying model of arterial brain circulation, based on the solution of the Navier-Stokes equation in the main arteries and their vascular territories. The atlas was successfully used to simulate electrical impedance tomography measurements indicating the necessity of signal-to-noise between 100 and 125dB to identify vascular changes due to the cardiac cycle, corroborating previous studies.
△ Less
Submitted 19 August, 2021;
originally announced August 2021.
-
Material-separating regularizer for multi-energy X-ray tomography
Authors:
Jacek Gondzio,
Matti Lassas,
Salla-Maaria Latva-Äijö,
Samuli Siltanen,
Filippo Zanetti
Abstract:
Dual-energy X-ray tomography is considered in a context where the target under imaging consists of two distinct materials. The materials are assumed to be possibly intertwined in space, but at any given location there is only one material present. Further, two X-ray energies are chosen so that there is a clear difference in the spectral dependence of the attenuation coefficients of the two materia…
▽ More
Dual-energy X-ray tomography is considered in a context where the target under imaging consists of two distinct materials. The materials are assumed to be possibly intertwined in space, but at any given location there is only one material present. Further, two X-ray energies are chosen so that there is a clear difference in the spectral dependence of the attenuation coefficients of the two materials. A novel regularizer is presented for the inverse problem of reconstructing separate tomographic images for the two materials. A combination of two things, (a) non-negativity constraint, and (b) penalty term containing the inner product between the two material images, promotes the presence of at most one material in a given pixel. A preconditioned interior point method is derived for the minimization of the regularization functional. Numerical tests with digital phantoms suggest that the new algorithm outperforms the baseline method, Joint Total Variation regularization, in terms of correctly material-characterized pixels. While the method is tested only in a two-dimensional setting with two materials and two energies, the approach readily generalizes to three dimensions and more materials. The number of materials just needs to match the number of energies used in imaging.
△ Less
Submitted 28 June, 2021;
originally announced July 2021.
-
Fuel rod classification from Passive Gamma Emission Tomography (PGET) of spent nuclear fuel assemblies
Authors:
Riina Virta,
Rasmus Backholm,
Tatiana A. Bubba,
Tapio Helin,
Mikael Moring,
Samuli Siltanen,
Peter Dendooven,
Tapani Honkamaa
Abstract:
Safeguarding the disposal of spent nuclear fuel in a geological repository needs an effective, efficient, reliable and robust non-destructive assay (NDA) system to ensure the integrity of the fuel prior to disposal. In the context of the Finnish geological repository, Passive Gamma Emission Tomography (PGET) will be a part of such an NDA system. We report here on the results of PGET measurements a…
▽ More
Safeguarding the disposal of spent nuclear fuel in a geological repository needs an effective, efficient, reliable and robust non-destructive assay (NDA) system to ensure the integrity of the fuel prior to disposal. In the context of the Finnish geological repository, Passive Gamma Emission Tomography (PGET) will be a part of such an NDA system. We report here on the results of PGET measurements at the Finnish nuclear power plants during the years 2017-2020. Gamma activity profiles are recorded from all angles by rotating the detector arrays around the fuel assembly that has been inserted into the center of the torus. Image reconstruction from the resulting tomographic data is defined as a constrained minimization problem with a data fidelity term and regularization terms. The activity and attenuation maps, as well as detector sensitivity corrections, are the variables in the minimization process. The regularization terms ensure that prior information on the (possible) locations of fuel rods and their diameter are taken into account. Fuel rod classification, the main purpose of the PGET method, is based on the difference of the activity of a fuel rod from its immediate neighbors, taking into account its distance from the assembly center. The classification is carried out by a support vector machine. We report on the results for ten different fuel types with burnups between 5.72 and 55.0 GWd/tU, cooling times between 1.87 and 34.6 years and initial enrichments between 1.9 and 4.4%. For all fuel assemblies measured, missing fuel rods, partial fuel rods and water channels were correctly classified. Burnable absorber fuel rods were classified as fuel rods. On rare occasions, a fuel rod that is present was falsely classified as missing. We conclude that the combination of the PGET device and our image reconstruction method provides a reliable base for fuel rod classification.
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
Simultaneous Reconstruction of Emission and Attenuation in Passive Gamma Emission Tomography of Spent Nuclear Fuel
Authors:
Rasmus Backholm,
Tatiana A. Bubba,
Camille Bélanger-Champagne,
Tapio Helin,
Peter Dendooven,
Samuli Siltanen
Abstract:
The International Atomic Energy Agency (IAEA) has recently approved passive gamma emission tomography (PGET) as a method for inspecting spent nuclear fuel assemblies (SFAs), an important aspect of international nuclear safeguards which aim at preventing the proliferation of nuclear weapons. The PGET instrument is essentially a single photon emission computed tomography (SPECT) system that allows t…
▽ More
The International Atomic Energy Agency (IAEA) has recently approved passive gamma emission tomography (PGET) as a method for inspecting spent nuclear fuel assemblies (SFAs), an important aspect of international nuclear safeguards which aim at preventing the proliferation of nuclear weapons. The PGET instrument is essentially a single photon emission computed tomography (SPECT) system that allows the reconstruction of axial cross-sections of the emission map of the SFA. The fuel material heavily self-attenuates its gamma-ray emissions, so that correctly accounting for the attenuation is a critical factor in producing accurate images. Due to the nature of the inspections, it is desirable to use as little a priori information as possible about the fuel, including the attenuation map, in the reconstruction process. Current reconstruction methods either do not correct for attenuation, assume a uniform attenuation throughout the fuel assembly, or assume an attenuation map based on an initial filtered back projection (FBP) reconstruction. Here, we propose a method to simultaneously reconstruct the emission and attenuation maps by formulating the reconstruction as a constrained minimization problem with a least squares data fidelity term and regularization terms. Using simulated data, we compare the proposed method to FBP, showing that our approach produces significantly better reconstructions by various numerical metrics and a much better classification of spent, missing, and fresh fuel rods.
△ Less
Submitted 17 April, 2019;
originally announced May 2019.
-
Joint Reconstruction in Low Dose Multi-Energy CT
Authors:
Jussi Toivanen,
Alexander Meaney,
Samuli Siltanen,
Ville Kolehmainen
Abstract:
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction…
▽ More
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction more ill-posed. In this paper, we propose how this problem can be overcome with a combination of a regularization method that promotes structural similarity between images at different energies and a suitably selected low-dose data acquisition protocol using non-overlapping projections. The performance of various joint regularization models is assessed with both simulated and experimental data, using the novel low-dose data acquisition protocol. Three of the models are well-established, namely the joint total variation, the linear parallel level sets and the spectral smoothness promoting regularization models. Furthermore, one new joint regularization model is introduced for multi-energy CT: a regularization based on the structure function from the structural similarity index. The findings show that joint regularization outperforms individual channel-by-channel reconstruction. Furthermore, the proposed combination of joint reconstruction and non-overlapping projection geometry enables significant reduction of radiation dose.
△ Less
Submitted 13 February, 2020; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Tomographic X-ray data of 3D cross phantom
Authors:
Salla Latva-Äijö,
Alexander Meaney,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of cross phantom made available at this https URL The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram with 16 or 30 time frames (depending on theresolution) of 2D slices of the phantom and (2) the corresponding static and…
▽ More
This is the documentation of the tomographic X-ray data of cross phantom made available at this https URL The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram with 16 or 30 time frames (depending on theresolution) of 2D slices of the phantom and (2) the corresponding static and dynamic measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 1 September, 2018;
originally announced September 2018.
-
Tomographic X-ray data of 3D emoji
Authors:
Alexander Meaney,
Zenith Purisha,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram of a single 2D slice of 33 emoji faces (contains 15 different emoji faces) made by sma…
▽ More
This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram of a single 2D slice of 33 emoji faces (contains 15 different emoji faces) made by small squared ceramic stones and (2) the corresponding static and dynamic measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 60-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
An automatic regularization method: An application for 3D X-ray micro-CT reconstruction using sparse data
Authors:
Zenith Purisha,
Sakari S. Karhula,
Juuso Ketola,
Juho Rimpeläinen,
Miika T. Nieminen,
Simo Saarakkala,
Heikki Kröger,
Samuli Siltanen
Abstract:
X-ray tomography is a reliable tool for determining the inner structure of 3D object with penetrating X-rays. However, traditional reconstruction methods such as FDK require dense angular sampling in the data acquisition phase leading to long measurement times, especially in X-ray micro-tomography to obtain high resolution scans. Acquiring less data using greater angular steps is an obvious way fo…
▽ More
X-ray tomography is a reliable tool for determining the inner structure of 3D object with penetrating X-rays. However, traditional reconstruction methods such as FDK require dense angular sampling in the data acquisition phase leading to long measurement times, especially in X-ray micro-tomography to obtain high resolution scans. Acquiring less data using greater angular steps is an obvious way for speeding up the process and avoiding the need to save huge data sets available memory. However, computing 3D reconstruction from such a sparsely sampled dataset is very sensitive to measurement noise and modelling errors. An automatic regularization method is proposed for robust reconstruction, based on enforcing sparsity in the three-dimensional shearlet transform domain. The inputs of the algorithm are the projection data and {\it a priori} known expected degree of sparsity, denoted $0<{\mathcal C}_{pr}\leq 1$. The number ${\mathcal C}_{pr}$ can be calibrated from a few dense-angle reconstructions and fixed. Human subchondral bone samples were tested and morphometric parameters of the bone reconstructions were then analyzed using standard metrics. The proposed method is shown to outperform the baseline algorithm (FDK) in the case of sparsely collected data. The number of X-ray projections can be reduced up to 10\% of the total amount while retaining the quality of the reconstruction images and of the morphometric paramaters.
△ Less
Submitted 6 April, 2018; v1 submitted 4 August, 2017;
originally announced August 2017.
-
Tomographic X-ray data of carved cheese
Authors:
Tatiana A. Bubba,
Markus Juvonen,
Jonatan Lehtonen,
Maximilian März,
Alexander Meaney,
Zenith Purisha,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/. The data set consists of (1) the X-ray sinogram of a single 2D slice of the cheese slice with three different resolutions and (2) the correspond…
▽ More
This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/. The data set consists of (1) the X-ray sinogram of a single 2D slice of the cheese slice with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 14 June, 2017; v1 submitted 12 May, 2017;
originally announced May 2017.
-
Open 2D Electrical Impedance Tomography data archive
Authors:
Andreas Hauptmann,
Ville Kolehmainen,
Nguyet Minh Mach,
Tuomo Savolainen,
Aku Seppänen,
Samuli Siltanen
Abstract:
This document reports an Open 2D Electrical Impedance Tomography (EIT) data set. The EIT measurements were collected from a circular body (a flat tank filled with saline) with various choices of conductive and resistive inclusions. Data are available at http://fips.fi/ EIT_dataset.php and can be freely used for scientific purposes with appropriate references to them, and to this document at https:…
▽ More
This document reports an Open 2D Electrical Impedance Tomography (EIT) data set. The EIT measurements were collected from a circular body (a flat tank filled with saline) with various choices of conductive and resistive inclusions. Data are available at http://fips.fi/ EIT_dataset.php and can be freely used for scientific purposes with appropriate references to them, and to this document at https://arxiv.org. The data set consists of (1) current patterns and voltage measurements of a circular tank containing different targets, (2) photos of the tank and targets and (3) a MATLAB-code for reading the data. A video report of the data collection session is available at https://www.youtube.com/watch?v=65Zca_qd1Y8.
△ Less
Submitted 4 April, 2017;
originally announced April 2017.
-
Photographic dataset: playing cards
Authors:
David Villacis,
Santeri Kaupinmäki,
Samuli Siltanen,
Teemu Helenius
Abstract:
This is a photographic dataset collected for testing image processing algorithms. The idea is to have images that can exploit the properties of total variation, therefore a set of playing cards was distributed on the scene. The dataset is made available at www.fips.fi/photographic_dataset2.php
This is a photographic dataset collected for testing image processing algorithms. The idea is to have images that can exploit the properties of total variation, therefore a set of playing cards was distributed on the scene. The dataset is made available at www.fips.fi/photographic_dataset2.php
△ Less
Submitted 25 January, 2017;
originally announced January 2017.
-
Tomographic X-ray data of a lotus root filled with attenuating objects
Authors:
Tatiana A. Bubba,
Andreas Hauptmann,
Simo Huotari,
Juho Rimpeläinen,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of a lotus root, filled with four different attenuating objects, of different sizes. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the lotu…
▽ More
This is the documentation of the tomographic X-ray data of a lotus root, filled with four different attenuating objects, of different sizes. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the lotus root with two different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 13 October, 2016; v1 submitted 23 September, 2016;
originally announced September 2016.
-
Photographic dataset: random peppercorns
Authors:
Teemu Helenius,
Samuli Siltanen
Abstract:
This is a photographic dataset collected for testing image processing algorithms. The idea is to have sets of different but statistically similar images. In this work the images show randomly distributed peppercorns. The dataset is made available at www.fips.fi/photographic_dataset.php .
This is a photographic dataset collected for testing image processing algorithms. The idea is to have sets of different but statistically similar images. In this work the images show randomly distributed peppercorns. The dataset is made available at www.fips.fi/photographic_dataset.php .
△ Less
Submitted 3 March, 2016;
originally announced March 2016.
-
Tomographic X-ray data of a walnut
Authors:
Keijo Hämäläinen,
Lauri Harhanen,
Aki Kallonen,
Antti Kujanpää,
Esa Niemi,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of a walnut made available at http://www.fips.fi/dataset.php . The data can be freely used for scientific purposes with appropriate references to the data and to this document in arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the walnut with three different resolutions and (2) the corresponding measurement matr…
▽ More
This is the documentation of the tomographic X-ray data of a walnut made available at http://www.fips.fi/dataset.php . The data can be freely used for scientific purposes with appropriate references to the data and to this document in arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the walnut with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 120-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. In addition, a larger set of 1200 projections of the same walnut was measured and a high-resolution filtered back-projection reconstruction was computed from this data; both the sinogram and the FBP reconstruction are included in the data set, the latter serving as a ground truth reconstruction.
△ Less
Submitted 11 February, 2015;
originally announced February 2015.
-
Estimation of conductivity changes in a region of interest with electrical impedance tomography
Authors:
Dong Liu,
Ville Kolehmainen,
Samuli Siltanen,
Anne maria Laukkanen,
Aku Seppanen
Abstract:
This paper proposes a novel approach to reconstruct changes in a target conductivity from electrical impedance tomography measurements. As in the conventional difference imaging, the reconstruction of the conductivity change is based on electrical potential measurements from the exterior boundary of the target before and after the change. In this paper, however, images of the conductivity before a…
▽ More
This paper proposes a novel approach to reconstruct changes in a target conductivity from electrical impedance tomography measurements. As in the conventional difference imaging, the reconstruction of the conductivity change is based on electrical potential measurements from the exterior boundary of the target before and after the change. In this paper, however, images of the conductivity before and after the change are reconstructed simultaneously based on the two data sets. The key feature of the approach is that the conductivity after the change is parameterized as a linear combination of the initial state and the change. This allows for modeling independently the spatial characteristics of the background conductivity and the change of the conductivity - by separate regularization functionals. The approach also allows in a straightforward way the restriction of the conductivity change to a localized region of interest inside the domain. While conventional difference imaging reconstruction is based on a global linearization of the observation model, the proposed approach amounts to solving a non-linear inverse problem. The feasibility of the proposed reconstruction method is tested experimentally and with a simulation which demonstrates a potential new medical application of electrical impedance tomography: imaging of vocal folds in voice loading studies.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.