-
Ultrasound cavitation and exfoliation dynamics of 2D materials re-vealed in operando by X-ray free electron laser megahertz imaging
Authors:
Kang Xiang,
Shi Huang,
Hongyuan Song,
Vasilii Bazhenov,
Valerio Bellucci,
Sarlota Birnsteinova,
Raphael de Wijn,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Adam Round,
Ekaterina Round,
Abhisakh Sarma,
Tokushi Sato,
Marcin Sikorski,
Yuhe Zhang,
Eleni Myrto Asimakopoulou,
Pablo Villanueva-Perez,
Kyriakos Porfyrakis,
Iakovos Tzanakis,
Dmitry G. Eskin,
Nicole Grobert,
Adrian Mancuso,
Richard Bean,
Patrik Vagovic,
Jiawei Mi
Abstract:
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simul…
▽ More
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simultaneously, most theories reported to date still remain elusive. Here, using the ultra-short X-ray Free Electron Laser pulses (~25ps) with a unique pulse train structure, we applied MHz X-ray Microscopy and machine-learning technique to reveal unambiguously the full cycles of the ultrasound cavitation and graphite layer exfoliation dynamics with sub-microsecond and micrometer resolution. Cyclic fatigue shock wave impacts produced by ultrasound cloud implosion were identified as the dominant mechanism to deflect and exfoliate graphite layers mechanically. For the graphite flakes, exfoliation rate as high as ~5 angstroms per shock wave impact was observed. For the HOPG graphite, the highest exfoliation rate was ~0.15 angstroms per impact. These new findings are scientifically and technologically important for developing industrial upscaling strategies for ultrasonic exfoliation of 2D materials.
△ Less
Submitted 23 June, 2023; v1 submitted 15 May, 2023;
originally announced May 2023.
-
Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging
Authors:
Yulong Zhuang,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (17 additional authors not shown)
Abstract:
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orien…
▽ More
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
3D diffractive imaging of nanoparticle ensembles using an X-ray laser
Authors:
Kartik Ayyer,
P. Lourdu Xavier,
Johan Bielecki,
Zhou Shen,
Benedikt J. Daurer,
Amit K. Samanta,
Salah Awel,
Richard Bean,
Anton Barty,
Tomas Ekeberg,
Armando D. Estillore,
Klaus Giewekemeyer,
Mark S. Hunter,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letruin,
Jannik Lübke,
Andrew J. Morgan,
Nils Roth,
Tokushi Sato,
Marcin Sikorski,
Florian Schulz
, et al. (12 additional authors not shown)
Abstract:
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 150…
▽ More
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Megahertz single-particle imaging at the European XFEL
Authors:
Egor Sobolev,
Serguey Zolotarev,
Klaus Giewekemeyer,
Johan Bielecki,
Kenta Okamoto,
Hemanth K. N. Reddy,
Jakob Andreasson,
Kartik Ayyer,
Imrich Barak,
Sadia Bari,
Anton Barty,
Richard Bean,
Sergey Bobkov,
Henry N. Chapman,
Grzegorz Chojnowski,
Benedikt J. Daurer,
Katerina Dörner,
Tomas Ekeberg,
Leonie Flückiger,
Oxana Galzitskaya,
Luca Gelisio,
Steffen Hauf,
Brenda G. Hogue,
Daniel A. Horke,
Ahmad Hosseinizadeh
, et al. (38 additional authors not shown)
Abstract:
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for…
▽ More
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.
△ Less
Submitted 14 December, 2019;
originally announced December 2019.
-
Femtosecond laser produced periodic plasma in a colloidal crystal probed by XFEL radiation
Authors:
Nastasia Mukharamova,
Sergey Lazarev,
Janne-Mieke Meijer,
Oleg Yu. Gorobtsov,
Andrej Singer,
Matthieu Chollet,
Michael Bussmann,
Dmitry Dzhigaev,
Yiping Feng,
Marco Garten,
Axel Huebl,
Thomas Kluge,
Ruslan P. Kurta,
Vladimir Lipp,
Robin Santra,
Marcin Sikorski,
Sanghoon Song,
Garth Williams,
Diling Zhu,
Beata Ziaja-Motyka,
Thomas Cowan,
Andrei V. Petukhov,
Ivan A. Vartanyants
Abstract:
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the…
▽ More
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the detailed study of periodic plasma created from the colloidal crystal. Both experimental data and theory modeling show that the periodicity in the sample survives to a large extent the extreme excitation and shock wave propagation inside the colloidal crystal. This feature enables probing the excited crystal, using the powerful Bragg peak analysis, in contrast to the conventional studies of dense plasma created from bulk samples for which probing with Bragg diffraction technique is not possible. X-ray diffraction measurements of excited colloidal crystals may then lead towards a better understanding of matter phase transitions under extreme irradiation conditions.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
Origin of vibrational wavepacket dynamics in Fe carbene photosensitizer determined with femtosecond X-ray emission and scattering
Authors:
Kristjan Kunnus,
Morgane Vacher,
Tobias C. B. Harlang,
Kasper S. Kjær,
Kristoffer Haldrup,
Elisa Biasin,
Tim B. van Driel,
Mátyás Pápa,
Pavel Chabera,
Yizhu Liu,
Hideyuki Tatsuno,
Cornelia Timm,
Erik Källman,
Mickaël Delcey,
Robert W. Hartsock,
Marco E. Reinhard,
Sergey Koroidov,
Mads G. Laursen,
Frederik B. Hansen,
Peter Vester,
Morten Christensen,
Lise Sandberg,
Zoltán Németh,
Dorottya Sárosiné Szemes,
Éva Bajnóczi
, et al. (16 additional authors not shown)
Abstract:
Disentangling the dynamics of electrons and nuclei during nonadiabatic molecular transformations remains a considerable experimental challenge. Here we have investigated photoinduced electron transfer dynamics following a metal-to-ligand charge-transfer (MLCT) excitation of the [Fe(bmip)2]2+ photosensitizer, where bmip = 2,6-bis(3-methyl-imidazole-1- ylidine)-pyridine, with simultaneous femtosecon…
▽ More
Disentangling the dynamics of electrons and nuclei during nonadiabatic molecular transformations remains a considerable experimental challenge. Here we have investigated photoinduced electron transfer dynamics following a metal-to-ligand charge-transfer (MLCT) excitation of the [Fe(bmip)2]2+ photosensitizer, where bmip = 2,6-bis(3-methyl-imidazole-1- ylidine)-pyridine, with simultaneous femtosecond-resolution Fe Kα and K\b{eta} X-ray Emission Spectroscopy (XES) and Wide Angle X-ray Scattering (WAXS). This measurement clearly shows temporal oscillations in the XES and WAXS difference signals with the same 278 fs period oscillation. The oscillatory signal originates from an Fe-ligand stretching mode vibrational wavepacket on a triplet metal-centered (3MC) excited state surface. The vibrational wavepacket is created by 40% of the excited population that undergoes electron transfer from the non-equilibrium MLCT excited state to the 3MC excited state with a 110 fs time constant, while the other 60% relaxes to a 3MLCT excited state in parallel. The sensitivity of the Kα XES spectrum to molecular structure results from core-level vibronic coupling, due to a 0.7% average Fe-ligand bond length difference in the lowest energy geometry of the 1s and 2p core-ionized states. These results highlight the importance of vibronic effects in time-resolved XES experiments and demonstrate the role of metal-centered excited states in the electronic excited state relaxation dynamics of an Fe carbene photosensitizer.
△ Less
Submitted 29 October, 2019;
originally announced October 2019.
-
Diffraction based Hanbury Brown and Twiss interferometry performed at a hard x-ray free-electron laser
Authors:
O. Yu. Gorobtsov,
N. Mukharamova,
S. Lazarev,
M. Chollet,
D. Zhu,
Y. Feng,
R. P. Kurta,
J. -M. Meijer,
G. Williams,
M. Sikorski,
S. Song,
D. Dzhigaev,
S. Serkez,
A. Singer,
A. V. Petukhov,
I. A. Vartanyants
Abstract:
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source…
▽ More
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source (LCLS). We observed high degree (80%) spatial coherence of the full beam and the pulse duration of the monochromatized beam on the order of 11 fs that is significantly shorter than expected from the electron bunch measurements.
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source
Authors:
S. Stoupin,
S. A. Terentyev,
V. D. Blank,
Yu. V. Shvyd'ko,
K. Goetze,
L. Assoufid,
S. N. Polyakov,
M. S. Kuznetsov,
N. V. Kornilov,
J. Katsoudas,
R. Alonso-Mori,
M. Chollet,
Y. Feng,
J. M. Glownia,
H. Lemke,
A. Robert,
S. Song,
M. Sikorski,
D. Zhu
Abstract:
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fa…
▽ More
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fabrication, and X-ray characterization of the first and second (300-um-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 X 2 mm2 with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 X 2 mm2 working regions of the crystals.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.