Charge collection properties of TowerJazz 180 nm CMOS Pixel Sensors in dependence of pixel geometries and bias parameters, studied using a dedicated test-vehicle: the Investigator chip
Authors:
G. Aglieri Rinella,
G. Chaosong,
A. di Mauro,
J. Eum,
H. Hillemanns,
A. Junique,
M. Keil,
D. Kim,
H. Kim,
T. Kugathasan,
S. Lee,
M. Mager,
V. Manzari,
C. A. Marin Tobon,
P. Martinengo,
H. Mugnier,
L. Musa,
F. Reidt,
J. Rousset,
K. Sielewicz,
W. Snoeys,
M. Šuljić,
J. W. van Hoorne,
Q. M. Waheed,
P. Yang
, et al. (1 additional authors not shown)
Abstract:
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation…
▽ More
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation Inner Tracking System of ALICE, and serve as reference for future simulation studies of similar devices. The studied parameters include: reverse substrate bias, epitaxial layer thickness, charge collection electrode size and the spacing of the electrode to surrounding in-pixel electronics. The results from pixels of 28 um pitch confirm that even in partially depleted circuits, charge collection can be fast (<10 ns), and quantify the influence of the parameters onto the signal sharing and amplitudes, highlighting the importance of a correct spacing between wells and of the impact of the reverse substrate bias.
△ Less
Submitted 23 September, 2020; v1 submitted 22 September, 2020;
originally announced September 2020.
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.