-
Electron transport and electric field simulations in two-phase detectors with THGEM electrodes
Authors:
Alexander Bondar,
Alexei Buzulutskov,
Egor Frolov,
Vladislav Oleynikov,
Ekaterina Shemyakina,
Andrey Sokolov
Abstract:
One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector, the THGEMs are used as electrodes in the gas and liquid phases to form the drift, electron emission and EL regions, as well as for avalanche amplification of a…
▽ More
One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector, the THGEMs are used as electrodes in the gas and liquid phases to form the drift, electron emission and EL regions, as well as for avalanche amplification of a signal in the gas phase. In this work the simulations of the electric field and electron transport through such THGEM electrodes were performed. In the liquid phase, these simulations allowed to determine the optimal parameters, such as the hole diameter of THGEM and applied voltage across it, that can provide effective transmission of the electrons from the drift region to that of the EL gap. In the gas phase, the effect of the THGHEM voltage on the electric field uniformity in the EL gap was studied.
△ Less
Submitted 2 September, 2019;
originally announced September 2019.
-
Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
E. Frolov,
V. Nosov,
V. Oleynikov,
E. Shemyakina,
A. Sokolov
Abstract:
We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detect…
▽ More
We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detection science are discussed, including those in two-phase dark matter detectors.
△ Less
Submitted 14 May, 2019;
originally announced May 2019.
-
Characterization of a 109Cd gamma-ray source for the two-phase argon detector
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Legkodymov,
V. Nosov,
V. Oleynikov,
V. Porosev,
E. Shemyakina,
A. Sokolov
Abstract:
At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission spectrum of the $^{109}$Cd source was measured using YAP:Ce scintillator and high-purity germanium (HPGe) detectors. It is shown that the $^{109}$Cd source, equi…
▽ More
At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission spectrum of the $^{109}$Cd source was measured using YAP:Ce scintillator and high-purity germanium (HPGe) detectors. It is shown that the $^{109}$Cd source, equipped with a W substrate and a Cu filter, can provide a complete set of gamma-ray lines, ranging from 8 to 90 keV, for the energy calibration of two-phase detectors. These measurements allowed us to successfully quantify the shape of the amplitude spectra observed in the two-phase argon detector when irradiated with the $^{109}$Cd source.
△ Less
Submitted 31 May, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
Revealing neutral bremsstrahlung in two-phase argon electroluminescence
Authors:
A. Buzulutskov,
E. Shemyakina,
A. Bondar,
A. Dolgov,
E. Frolov,
V. Nosov,
V. Oleynikov,
L. Shekhtman,
A. Sokolov
Abstract:
Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed that proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter…
▽ More
Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed that proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter being in turn produced by drifting electrons. In this work we consider an additional mechanism of proportional electroluminescence, namely that of bremsstrahlung of drifting electrons scattered on neutral atoms (so-called neutral bremsstrahlung); it is systemically studied here both theoretically and experimentally. In particular, the absolute EL yield has for the first time been measured in pure gaseous argon in the two-phase mode, using a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs and SiPMs. We show that the neutral bremsstrahlung effect can explain two intriguing observations in EL radiation: that of the substantial contribution of the non-VUV spectral component, extending from the UV to NIR, and that of the photon emission at lower electric fields, below the Ar excitation threshold. Possible applications of neutral bremsstrahlung effect in two-phase dark matter detectors are discussed.
△ Less
Submitted 20 June, 2018; v1 submitted 13 March, 2018;
originally announced March 2018.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
E. Grishnyaev,
V. Nosov,
V. Oleynikov,
S. Polosatkin,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
A measurement of ionization yields in noble-gas liquids is relevant to the energy calibration of nuclear recoil detectors for dark matter search and coherent neutrino-nucleus scattering experiments. In this work we further study the ionization yield of nuclear recoils in liquid Ar, using a two-phase detector with an electroluminescence gap and DD neutron generator. The ionization yields of nuclear…
▽ More
A measurement of ionization yields in noble-gas liquids is relevant to the energy calibration of nuclear recoil detectors for dark matter search and coherent neutrino-nucleus scattering experiments. In this work we further study the ionization yield of nuclear recoils in liquid Ar, using a two-phase detector with an electroluminescence gap and DD neutron generator. The ionization yields of nuclear recoils in liquid Ar were measured at 233 keV and electric fields of 0.56 and 0.62 kV/cm; their values amounted to 5.9 $\pm$ 0.8 and 7.4 $\pm$ 1 e$^-$/keV, respectively. The characteristic dependences of the ionization yield on energy and electric field were determined, while comparing the results obtained to those at lower energies and higher fields.
△ Less
Submitted 15 May, 2017;
originally announced May 2017.
-
Further studies of proportional electroluminescence in two-phase argon
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
E. Frolov,
V. Nosov,
V. Oleynikov,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
The study of proportional electroluminescence in two-phase argon is relevant in the field of noble-gas liquid detectors for dark matter search and low-energy neutrino experiments. In this work, we continued to study proportional electroluminescence (EL) in two-phase argon doped with a minor (9 ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We confirmed the effect of enhanc…
▽ More
The study of proportional electroluminescence in two-phase argon is relevant in the field of noble-gas liquid detectors for dark matter search and low-energy neutrino experiments. In this work, we continued to study proportional electroluminescence (EL) in two-phase argon doped with a minor (9 ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We confirmed the effect of enhancement of the EL yield, as well as the presence of non-VUV component in addition to that of VUV, in proportional electroluminescence in two-phase Ar. On the other hand, the contribution of non-VUV component determined here within the model of N2 emission in the UV, turned out to be insufficient to explain the EL yield enhancement effect. Accordingly, the problem of proportional electroluminescence in two-phase Ar remains unresolved.
△ Less
Submitted 15 May, 2017;
originally announced May 2017.
-
Two-phase Cryogenic Avalanche Detector with electroluminescence gap operated in argon doped with nitrogen
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
V. Nosov,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
A two-phase Cryogenic Avalanche Detector (CRAD) with electroluminescence (EL) gap, operated in argon doped with a minor (49$\pm$7 ppm) admixture of nitrogen, has been studied. The EL gap was optically read out using cryogenic PMTs located on the perimeter of the gap. We present the results of the measurements of the N$_2$ content, detector sensitivity to X-ray-induced signals, EL gap yield and ele…
▽ More
A two-phase Cryogenic Avalanche Detector (CRAD) with electroluminescence (EL) gap, operated in argon doped with a minor (49$\pm$7 ppm) admixture of nitrogen, has been studied. The EL gap was optically read out using cryogenic PMTs located on the perimeter of the gap. We present the results of the measurements of the N$_2$ content, detector sensitivity to X-ray-induced signals, EL gap yield and electron lifetime in the liquid. The detector sensitivity, at a drift field in liquid Ar of 0.6 kV/cm, was measured to be 9 and 16 photoelectrons recorded at the PMTs per keV of deposited energy at 23 and 88 keV respectively. Such two-phase detectors, with enhanced sensitivity to the S2 (ionization-induced) signal, are relevant in the field of argon detectors for dark matter search and low energy neutrino detection.
△ Less
Submitted 27 May, 2016;
originally announced May 2016.
-
Proportional electroluminescence in two-phase argon and its relevance to rare-event experiments
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
V. Nosov,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
Proportional electroluminescence (EL) in gaseous Ar has for the first time been systematically studied in the two-phase mode, at 87 K and 1.00 atm. Liquid argon had a minor (56 ppm) admixture of nitrogen, which allowed to understand, inter alia, the effect of N2 doping on the EL mechanism in rare-event experiments using two-phase Ar detectors. The measurements were performed in a two-phase Cryogen…
▽ More
Proportional electroluminescence (EL) in gaseous Ar has for the first time been systematically studied in the two-phase mode, at 87 K and 1.00 atm. Liquid argon had a minor (56 ppm) admixture of nitrogen, which allowed to understand, inter alia, the effect of N2 doping on the EL mechanism in rare-event experiments using two-phase Ar detectors. The measurements were performed in a two-phase Cryogenic Avalanche Detector (CRAD) with EL gap located directly above the liquid-gas interface. The EL gap was optically read out in the Vacuum Ultraviolet (VUV), near 128 nm (Ar excimer emission), and in the near Ultraviolet (UV), at 300-450 nm (N2 Second Positive System emission), via cryogenic PMTs and a Geiger-mode APD (GAPD). Proportional electroluminescence was measured to have an amplification parameter of 109+-10 photons per drifting electron per kV overall in the VUV and UV, of which 51+-6% were emitted in the UV. The measured EL threshold, at an electric field of 3.7+-0.2 kV/cm, was in accordance with that predicted by the theory. The latter result is particularly relevant to DarkSide and SCENE dark matter search-related experiments, where the operation electric field was thereby on the verge of appearance of the S2 (ionization-induced) signal. The results obtained pave the way to the development of N2-doped two-phase Ar detectors with enhanced sensitivity to the S2 signal.
△ Less
Submitted 20 October, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
MPPC versus MRS APD in two-phase Cryogenic Avalanche Detectors
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
E. Shemyakina,
A. Sokolov
Abstract:
Two-phase Cryogenic Avalanche Detectors (CRADs) with combined THGEM/GAPD multiplier have become an emerging potential technique for dark matter search and coherent neutrino-nucleus scattering experiments. In such a multiplier the THGEM hole avalanches are optically recorded in the Near Infrared (NIR) using a matrix of Geiger-mode APDs (GAPDs). To select the proper sensor, the performances of six G…
▽ More
Two-phase Cryogenic Avalanche Detectors (CRADs) with combined THGEM/GAPD multiplier have become an emerging potential technique for dark matter search and coherent neutrino-nucleus scattering experiments. In such a multiplier the THGEM hole avalanches are optically recorded in the Near Infrared (NIR) using a matrix of Geiger-mode APDs (GAPDs). To select the proper sensor, the performances of six GAPD types manufactured by different companies, namely by Hamamatsu (MPPCs), CPTA (MRS APDs) and SensL (SiPMs), have been comparatively studied at cryogenic temperatures when operated in two-phase CRADs in Ar at 87 K. While the GAPDs with ceramic packages failed to operate properly at cryogenic temperatures, those with plastic packages, namely MPPC S10931-100P and MRS APD 149-35, showed satisfactory performances at 87 K. In addition, MPPC S10931-100P turned out to be superior in terms of the higher detection efficiency, lower nose rate, lower pixel quenching resistor and better characteristics reproducibility.
△ Less
Submitted 12 February, 2015;
originally announced February 2015.
-
Measurement of the ionization yield of nuclear recoils in liquid argon at 80 and 233 keV
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
E. Grishnyaev,
S. Polosatkin,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by measuring the ionization yield of nuclear recoils in liquid Ar and Xe detection media, using neutron elastic scattering off nuclei. In the present work, the ioniza…
▽ More
The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by measuring the ionization yield of nuclear recoils in liquid Ar and Xe detection media, using neutron elastic scattering off nuclei. In the present work, the ionization yield for nuclear recoils in liquid Ar has for the first time been measured in the higher energy range, at 80 and 233 keV, using a two-phase Cryogenic Avalanche Detector (CRAD) and DD neutron generator. The ionization yield in liquid Ar at an electric field of 2.3 kV/cm amounted to 7.8+/-1.1 and 9.7+/-1.3 e-/keV at 80 and 233 keV respectively. The Jaffe model for nuclear recoil-induced ionization, in contrast to that Thomas-Imel, can probably consistently describe the energy dependence of the ionization yield.
△ Less
Submitted 23 September, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.
-
Performance degradation of Geiger-mode APDs at cryogenic temperatures
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
L. Shekhtman,
E. Shemyakina,
A. Sokolov,
A. Breskin,
D. Thers
Abstract:
Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multipli…
▽ More
Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multiplier; the GAPDs recorded secondary scintillation photons from the THGEM holes in the Near Infrared. The degradation effect, namely the loss of the GAPD pulse amplitude, depended on the incident X-ray photon flux. The critical counting rate of photoelectrons produced at the 4.4 mm2 GAPD, degrading its performance at 87 K, was estimated as 10000 per second. This effect was shown to result from the considerable increase of the pixel quenching resistor of this CPTA-made GAPD type. Though not affecting low-rate rare-event experiments, the observed effect may impose some limitations on the performance of CRADs with GAPD-based optical readout at higher-rate applications.
△ Less
Submitted 18 June, 2014;
originally announced June 2014.
-
First demonstration of THGEM/GAPD-matrix optical readout in two-phase Cryogenic Avalanche Detector in Ar
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
A. Breskin,
D. Thers
Abstract:
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near Infrared (NIR). At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted at ~80 photoelectrons per 20 keV X-ray absorbed…
▽ More
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near Infrared (NIR). At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted at ~80 photoelectrons per 20 keV X-ray absorbed in the liquid phase. A spatial resolution of 2.5 mm (FWHM) has been measured for the impinging X-rays. This technique has potential applications in coherent neutrino-nucleus scattering and dark matter search experiments.
△ Less
Submitted 19 March, 2013;
originally announced March 2013.
-
Two-phase Cryogenic Avalanche Detectors with THGEM and hybrid THGEM/GEM multipliers operated in Ar and Ar+N2
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
D. Akimov,
A. Breskin,
D. Thers
Abstract:
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multipl…
▽ More
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multiplier. Higher gains, of about 5000, have been attained in two-phase Ar CRADs with a hybrid triple-stage multiplier, comprising of a double-THGEM followed by a GEM. The performance of two-phase CRADs in Ar doped with N2 (0.1-0.6%) yielded faster signals and similar gains compared to the operation in two-phase Ar. The applicability to rare-event experiments is discussed.
△ Less
Submitted 2 October, 2012;
originally announced October 2012.
-
Study of infrared scintillations in gaseous and liquid argon - Part II: light yield and possible applications
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
S. Peleganchuk,
V. Porosev,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was foun…
▽ More
We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was found to be independent of temperature in the range of 87-160 K; it amounted to 17000+/-3000 photon/MeV in the NIR in the range of 690-1000 nm. In liquid Ar at 87 K, the primary scintillation yield of the fast component was considerably reduced, amounting to 510+/-90 photon/MeV, in the range of 400-1000 nm. Proportional NIR scintillations (electroluminescence) in gaseous Ar were also observed; their amplification parameter at 160 K was measured to be 13 photons per drifting electron per kV. No proportional scintillations were observed in liquid Ar up to the electric fields of 30 kV/cm. The applications of NIR scintillations in dark matter search and coherent neutrino-nucleus scattering experiments and in ion beam radiotherapy are considered.
△ Less
Submitted 28 May, 2012; v1 submitted 2 April, 2012;
originally announced April 2012.
-
Study of infrared scintillations in gaseous and liquid argon - Part I: methodology and time measurements
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov
Abstract:
A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of Cryogenic Avalanche Detectors (CRADs) with optical readout in the NIR using combined THGEM/GAPD multiplier, which may come to be in demand in coherent neutrino-nucleu…
▽ More
A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of Cryogenic Avalanche Detectors (CRADs) with optical readout in the NIR using combined THGEM/GAPD multiplier, which may come to be in demand in coherent neutrino-nucleus scattering and dark matter search experiments. A new approach to measure the NIR scintillation yield at cryogenic temperatures has been developed, namely using GAPDs in single photoelectron counting mode with time resolution. The time structure of NIR scintillations and their light yield were measured both for primary scintillations and that of secondary at moderate electric fields (electroluminescence), in gaseous and liquid Ar.
△ Less
Submitted 1 April, 2012;
originally announced April 2012.
-
On the low-temperature performances of THGEM and THGEM/G-APD multipliers in gaseous and two-phase Xe
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
D. Akimov,
I. Alexandrov,
A. Breskin
Abstract:
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors…
▽ More
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors incorporating GEM and THGEM multipliers. The optical readout of THGEMs with Geiger-mode Avalanche Photodiodes (G-APDs) has been investigated in gaseous Xe at cryogenic temperature; avalanche scintillations were recorded in the Near Infrared (NIR) at wavelengths of up to 950 nm. At avalanche charge gain of 350, the double-THGEM/G-APD multiplier yielded 0.07 photoelectrons per initial ionization electron, corresponding to an avalanche scintillation yield of 0.7 NIR photons per avalanche electron over 4pi. The results are compared with those of two-phase Ar avalanche detectors. The advantages, limitations and possible applications are discussed.
△ Less
Submitted 21 July, 2011; v1 submitted 31 March, 2011;
originally announced March 2011.