-
Design studies of a continuous-wave normal conducting buncher for European X-FEL
Authors:
Shankar Lal,
V. Paramonov,
H. Qian1,
H. Shaker,
G. Shu,
Ye Chen,
F. Stephan
Abstract:
A three-cell 1.3 GHz, Normal Conducting (NC) buncher is designed for a possible future upgrade of the European XFEL to operate in a continuous-wave (CW) / long pulse (LP) mode. The RF geometry of the buncher is optimized for high shunt impedance, large mode separation as well as multipacting free in the operation range. The bunchersupport cavity voltage of 400 kV with an RF power dissipation of 14…
▽ More
A three-cell 1.3 GHz, Normal Conducting (NC) buncher is designed for a possible future upgrade of the European XFEL to operate in a continuous-wave (CW) / long pulse (LP) mode. The RF geometry of the buncher is optimized for high shunt impedance, large mode separation as well as multipacting free in the operation range. The bunchersupport cavity voltage of 400 kV with an RF power dissipation of 14 kW. A tapered waveguide-based RF power coupler is designed to feed the RF power to the buncher. The RF power coupler port is optimized for field asymmetry compensation. The thermal load due to RF power dissipation is analyzed using Multiphysics simulations in CST and a simplified cooling scheme is designed.
△ Less
Submitted 24 December, 2021;
originally announced December 2021.
-
Improved Buildup Model for Radiation-Induced Defects in MOSFET Isolation Oxides
Authors:
Hesham. H. Shaker,
A. A. Saleh,
Mohamed Refky Amin,
S. E. D. Habib
Abstract:
Ionizing radiation induces defects in STI oxides in current MOSFETs. These defects may degrade the performance of the MOS circuit. Analytical models for the buildup of these defects during the radiation exposure are available in literature. In this paper, we show that the classical model used to estimate the buildup of TID-induced traps in MOSTs predicts inaccurate results at high radiation levels…
▽ More
Ionizing radiation induces defects in STI oxides in current MOSFETs. These defects may degrade the performance of the MOS circuit. Analytical models for the buildup of these defects during the radiation exposure are available in literature. In this paper, we show that the classical model used to estimate the buildup of TID-induced traps in MOSTs predicts inaccurate results at high radiation levels. We, further, introduce an improved model to estimate the buildup of defects that is valid for both low and high radiation doses. Our improved model is compared to published data showing its validity.
△ Less
Submitted 26 September, 2020;
originally announced September 2020.
-
Single shot cathode transverse momentum imaging in high brightness photoinjectors
Authors:
Peng-Wei Huang,
Houjun Qian,
Ye Chen,
Daniele Filippetto,
Matthias Gross,
Igor Isaev,
Christian Koschitzki,
Mikhail Krasilnikov,
Shankar Lal,
Xiangkun Li,
Osip Lishilin,
David Melkumyan,
Raffael Niemczyk,
Anne Oppelt,
Fernando Sannibale,
Hamed Shaker,
Guan Shu,
Frank Stephan,
Chuanxiang Tang,
Grygorii Vashchenko,
Weishi Wan
Abstract:
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the li…
▽ More
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode RF guns. By tuning the gun solenoid focusing, the electrons transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons transverse momenta. Both simulations and proof of principle experiments are reported.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.