-
Plasma treated metals after H- irradiation and its effect on vacuum breakdown behaviour
Authors:
C. Serafim,
S. Calatroni,
F. Djurabekova,
M. C. Giordano,
M. Himmerlich,
V. Bjelland,
C. Kouzios,
P. Costa Pinto,
A. T. Perez-Fontenla,
W. Wuensch,
A. Grudiev,
S. Sgobba
Abstract:
Vacuum breakdown in accelerator structures is a critical challenge that occurs under high electric fields. In environments subjected to hydrogen ion irradiation or high beam losses, such as in Radio-Frequency Quadrupoles (RFQ), residual hydrocarbons from the vacuum may result in carbon contamination of the metal surfaces from charged particle induced cracking. Under these conditions, it has been a…
▽ More
Vacuum breakdown in accelerator structures is a critical challenge that occurs under high electric fields. In environments subjected to hydrogen ion irradiation or high beam losses, such as in Radio-Frequency Quadrupoles (RFQ), residual hydrocarbons from the vacuum may result in carbon contamination of the metal surfaces from charged particle induced cracking. Under these conditions, it has been assessed that surface carbon contamination leads to a decrement of the surface electric field holding properties. This study extends the latest research by exploring the efficacy of Oxygen Plasma Cleaning (OPC) on metal electrodes irradiated by low energy hydrogen ion beam with the purpose of reducing surface carbon contamination. OPC treatment has been employed on different metals, namely copper beryllium (CuBe2), oxygen-free copper (Cu-OFE), and stainless steel (SS316LN). Treated electrodes have been tested for electric field performance in a DC pulsed system and results compared with non-irradiated electrodes and irradiated ones without OPC treatment. The study indicates a significant reduction in carbon contamination by OPC, enough to allow irradiated materials to achieve performances comparable with the electric field strength of raw surfaces. Moreover, it has been observed that stainless steel samples had some alteration in the surface chemistry that enhanced the materials ability to sustain high electric fields while decreasing vacuum arcing events. Notably, OPC treated SS316LN electrodes surpassed the performance value of untreated ones, demonstrating the potential of plasma treatments in extending the operational performance of accelerator components.
△ Less
Submitted 21 March, 2025;
originally announced March 2025.
-
Influence of nanoparticulates and microgrooves on the secondary electron yield and electrical resistance of laser-treated copper surfaces
Authors:
P. Krkotić,
T. Madarász,
C. Serafim,
H. Neupert,
A. T. Perez-Fontenla,
M. Himmerlich,
S. Calatroni
Abstract:
Laser surface structuring has proven to be an effective technique for achieving a copper surface with secondary electron yield (SEY) values close to or below unity. However, the attributes that minimize SEY, such as moderately deep grooves and redeposited nanoparticles, may lead to undesirable consequences, including increased radio frequency surface resistance. This investigation systematically e…
▽ More
Laser surface structuring has proven to be an effective technique for achieving a copper surface with secondary electron yield (SEY) values close to or below unity. However, the attributes that minimize SEY, such as moderately deep grooves and redeposited nanoparticles, may lead to undesirable consequences, including increased radio frequency surface resistance. This investigation systematically examined data about different cleaning procedures designed to eliminate redeposited adsorbed particulates. Various analysis techniques were used iteratively after each consecutive cleaning step, providing insights into the evolving surface characteristics. The collected experimental results identified distinct impacts of microgrooves, groove orientation, and associated particulates on secondary electron yield and surface resistance. Exposing the crests while retaining high particulate coverage in the grooves leads to reduced SEY values and surface resistance, suggesting that the tips of the grooves exert a more significant influence on surface current density than the groove depth. At the same time, nanoparticles in the grooves have a more significant impact on SEY values than the exposed tips at the surface.
△ Less
Submitted 1 February, 2025;
originally announced February 2025.
-
Initial high electric field -- vacuum arc breakdown test results for additively manufactured pure copper electrodes
Authors:
A. Ratkus,
T. Torims,
G. Pikurs,
V. Bjelland,
S. Calatroni,
R. Peacock,
C. Serafim,
M. Vretenar,
W. Wuensch
Abstract:
Additive Manufacturing (AM) is already well-established for various manufacturing applications, providing many benefits such as design freedom, novel and complex cooling designs for the parts and different performance improvements, as well as significantly reducing the production time. With the mentioned characteristics, AM is also being considered as a technology for manufacturing a Radio Frequen…
▽ More
Additive Manufacturing (AM) is already well-established for various manufacturing applications, providing many benefits such as design freedom, novel and complex cooling designs for the parts and different performance improvements, as well as significantly reducing the production time. With the mentioned characteristics, AM is also being considered as a technology for manufacturing a Radio Frequency Quadrupole (RFQ) prototype. For this application, an important parameter is the voltage holding capability of the surfaces. Furthermore, the voltage holding capability of pure copper surfaces manufactured by AM is of interest for the accelerator community at large for prospective future developments. To characterize these properties, a series of high electric field tests were performed on pure copper electrodes produced by AM, using the CERN pulsed high-voltage DC system. The tests were carried out with AM produced electrodes with large surface roughness. During the testing process, a high vacuum was maintained. The electric breakdown rate was also monitored to ensure not to exceed the breakdown limit of 10 $^{-5}$ breakdowns per pulse. The achieved results provide the first, initial reference values for the performance of AM built pure copper electrodes for vacuum arc breakdown testing. Initial results prove the capability of AM electrodes to hold a high electric field, while having low breakdown rates. These are crucial results for further AM technology usage for different AM pure-copper accelerator components
△ Less
Submitted 2 October, 2024;
originally announced October 2024.
-
Electron Beam Characterization of REBCO-Coated Conductors at Cryogenic Conditions
Authors:
Michal Haubner,
Patrick Krkotic,
Catarina Serafim,
Valentine Petit,
Vincent Baglin,
Sergio Calatroni,
Bernard Henrist,
Artur Romanov,
Teresa Puig,
Joffre Gutierrez
Abstract:
Particle accelerators with superconducting magnets operating at cryogenic temperatures use a beam screen (BS) liner that extracts heat generated by the circulating bunched charge particle beam before it can reach the magnets. The BS surface, commonly made of high-conductivity copper, provides a low impedance for beam stability reasons, low secondary electron yield (SEY)to mitigate the electron-clo…
▽ More
Particle accelerators with superconducting magnets operating at cryogenic temperatures use a beam screen (BS) liner that extracts heat generated by the circulating bunched charge particle beam before it can reach the magnets. The BS surface, commonly made of high-conductivity copper, provides a low impedance for beam stability reasons, low secondary electron yield (SEY)to mitigate the electron-cloud (EC) effect, and low electron-stimulated desorption yield (ESD) to limit the dynamic pressure rise due to EC. Rare-earth barium copper oxide (REBCO) high-temperature superconductors (HTs) recently reached technical maturity, are produced as coated conductor tapes (REBCO-CCs), and will be considered for application in future colliders to decrease the BS impedance and enable operation at around 50 K, consequently relaxing the cryogenic requirements. Aside from HTS properties, industry-grade REBCO-CCs also need qualification for EC and dynamic vacuum compatibility under accelerator-like conditions. Hence, we report the SEY and ESD measured at cryogenic temperatures of 12 K under low-energy electron irradiation of 0 - 1.4 keV. We also verify the sample compositions and morphologies using XPS, SEM, and EDS methods. The energy and dose dependencies of ESD are comparable to those of technical-grade metals and one sample reached SEY$_{MAX}=$1.2 after electron conditioning.
△ Less
Submitted 1 October, 2024;
originally announced October 2024.
-
Investigation on different materials after pulsed high field conditioning and low-energy H- irradiation
Authors:
Catarina Serafim,
R. Peacock,
S. Calatroni,
F. Djurabekova,
A. T. Fontenla,
W. Wuensch,
S. Sgobba,
A. Grudiev,
A. Lombardi,
E. Sargsyan,
S. Ramberger,
G. Bellodi
Abstract:
During operation, the radio-frequency quadrupole (RFQ) of the LINAC4 at CERN is exposed to high electric fields, which can lead to vacuum breakdown. It is also subject to beam loss, which can cause surface modification, including blistering, which can result in reduced electric field holding and an increased breakdown rate. First, experiments to study the high-voltage conditioning process and elec…
▽ More
During operation, the radio-frequency quadrupole (RFQ) of the LINAC4 at CERN is exposed to high electric fields, which can lead to vacuum breakdown. It is also subject to beam loss, which can cause surface modification, including blistering, which can result in reduced electric field holding and an increased breakdown rate. First, experiments to study the high-voltage conditioning process and electrical breakdown statistics have been conducted using pulsed high voltage DC systems in order to identify materials with high electric field handling capability and robustness to low-energy irradiation. In this paper, we discuss the results obtained for the different materials tested. To complement these, an investigation of their metallurgical properties using advanced microscopic techniques was done to observe and characterize the different materials and to compare results before and after irradiation and breakdown testing.
△ Less
Submitted 30 September, 2024;
originally announced October 2024.
-
Effects of H$^-$ low beam irradiation and high field pulsing tests in different metals
Authors:
C. Serafim,
S. Calatroni,
F. Djurabekov,
R. Peacock,
V. Bjelland,
A. T. Perez-Fontenla,
W. Wuensch,
A. Grudiev,
S. Sgobba A. Lombardi,
E. Sargsyan
Abstract:
This work studies the suitability of a set of different materials for manufacturing of more efficient and durable Radio-Frequency Quadrupole (RFQ) structures compared to that currently used in many linear particle accelerators, traditionally made out of copper. RFQs are susceptible to vacuum breakdowns caused by the exposure to high electric fields, resulting in surface degradation. Additionally,…
▽ More
This work studies the suitability of a set of different materials for manufacturing of more efficient and durable Radio-Frequency Quadrupole (RFQ) structures compared to that currently used in many linear particle accelerators, traditionally made out of copper. RFQs are susceptible to vacuum breakdowns caused by the exposure to high electric fields, resulting in surface degradation. Additionally, a further limitation of present-day copper RFQs is surface blistering under hydrogen ion beam exposure, due to beam halo losses. Irradiation is associated with a further reduction of the breakdown field strength of the metal surface thereby affecting the overall efficiency of the RFQ. The investigated materials, Cu-OFE, CuCr1Zr, CuBe2, Ti6Al4V, SS316LN, Nb and Ta, were submitted to low-energy (45 keV) H$^-$ irradiation and tested in a direct-current (DC) system with pulsed high voltage. For comparison, the maximum surface electric field was measured for both irradiated and pristine (non irradiated) surfaces of the same material. The effects of irradiation on the surface of the materials, before and after being submitted to high electric fields, were studied with the help of microscopic imaging and chemical analysis. Blistering caused by H$^-$ irradiation has been observed in all copper and copper alloy materials. Despite reductions in breakdown field strength post-irradiation, no indications were found that the blisters on the surface have a direct cause in triggering breakdowns during high electric field tests. SS316LN, Ti6Al4V, CuBe2 and CuCr1Zr showed maximum surface electric fields higher than copper, making these promising candidate materials for future RFQs manufacturing. This paper focuses on the results with CuCr1Zr, CuBe2, SS316LN and Ta, complementing and expanding previous work exploring Cu-OFE, Nb and Ti6Al4V.
△ Less
Submitted 3 February, 2025; v1 submitted 29 September, 2024;
originally announced September 2024.