-
Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
Authors:
B. M. Latacz,
M. Fleck,
J. I. Jaeger,
G. Umbrazunas,
B. P. Arndt,
S. R. Erlewein,
E. J. Wursten,
J. A. Devlin,
P. Micke,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we dem…
▽ More
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
Authors:
C. Will,
M. Wiesinger,
P. Micke,
H. Yildiz,
T. Driscoll,
S. Kommu,
F. Abbass,
B. P. Arndt,
B. B. Bauer,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
A. Mooser,
D. Schweitzer,
G. Umbrazunas,
E. Wursten,
K. Blaum,
J. A. Devlin,
C. Ospelkaus,
W. Quint,
A. Soter,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a mileston…
▽ More
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Ultra thin polymer foil cryogenic window for antiproton deceleration and storage
Authors:
B. M. Latacz,
B. P. Arndt,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. I. Jäger,
P. Micke,
G. Umbrazunas,
E. Wursten,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
C. Smorra,
A. Sótér,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons thro…
▽ More
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Authors:
Markus Wiesinger,
Florian Stuhlmann,
Matthew A. Bohman,
Peter Micke,
Christian Will,
Hüseyin Yildiz,
Fatma Abbass,
Bela P. Arndt,
Jack A. Devlin,
Stefan Erlewein,
Markus Fleck,
Julia I. Jäger,
Barbara M. Latacz,
Daniel Schweitzer,
Gilbertas Umbrazunas,
Elise Wursten,
Klaus Blaum,
Yasuyuki Matsuda,
Andreas Mooser,
Wolfgang Quint,
Anna Soter,
Jochen Walz,
Christian Smorra,
Stefan Ulmer
Abstract:
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at ro…
▽ More
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams
Authors:
M. Gai,
D. Schweitzer,
S. R. Stern,
A. H. Young,
R. Smith,
M. Cwiok,
J. S. Bihalowicz,
H. Czyrkowski,
R. Dabrowski,
W. Dominik,
A. Fijalkowska,
Z. Janas,
L. Janiak,
A. Korgul,
T. Matulewicz,
C. Mazzocchi,
M. Pfuetzner,
M. Zaremba,
D. Balabanski,
I. Gheorghe,
C. Matei,
O. Tesileanu,
N. V. Zamfir,
M. W. Ahmed,
S. S. Henshaw
, et al. (11 additional authors not shown)
Abstract:
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo…
▽ More
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We review the progress of the current research program and plans for the future at the HIγS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).
△ Less
Submitted 22 December, 2018;
originally announced December 2018.