Using Stable Distributions to Characterize Proton Pencil Beams
Authors:
Frank Van den Heuvel,
Francesca Fiorini,
Niek Schreuder,
Ben George
Abstract:
Purpose: To introduce and evaluate the use of stable distributions as a means of describing the behavior of charged particle pencil beams in a medium, with specific emphasis on proton beam scanning (PBS). Methods: The proton pencil beams of a clinically commissioned proton treatment facility are replicated in a Monte Carlo simulation system (FLUKA). For each available energy the beam deposition in…
▽ More
Purpose: To introduce and evaluate the use of stable distributions as a means of describing the behavior of charged particle pencil beams in a medium, with specific emphasis on proton beam scanning (PBS). Methods: The proton pencil beams of a clinically commissioned proton treatment facility are replicated in a Monte Carlo simulation system (FLUKA). For each available energy the beam deposition in water medium is characterized by the dose deposition. Using an alpha--stable distribution methodology each beam with a nominal energy $E$ is characterized by the lateral spread at depth $z$: $S(z;α,γ,E)$ and a total energy deposition $I_D(z)$. The beams are then described as a function of the variation of the parameters at depth. Finally, an implementation in a freely available open source dose calculation suite (matRad, DKFZ, Heidelberg, Germany) is proposed. Results: Quantitatively, the fit of the stable distributions, compared to those implemented in standard treatment planning systems, are equivalent. The efficiency of the representation is better (2 compared to 3 and more parameters needed). The meta--parametrization (i.e. the description of the dose deposition by only providing the fitted parameters) allows for interpolation of non--measured data. In the case of the clinical data used in this paper, it was possible to only commission 1 out of 5 nominal energies to obtain a viable data set. Conclusions: Alpha--stable distributions are intrinsically suited to describe charged particle pencil beams in a medium and can be easily implemented in existing treatment planning systems. The use of alpha-distributions can easily be extended to other particles.
△ Less
Submitted 27 November, 2016;
originally announced November 2016.
Design of the MPRI Control System
Authors:
J. C. Collins,
M. Ball,
B. Broderick,
J. Katuin,
Wm. Manwaring,
N. Schreuder
Abstract:
The Indiana University Cyclotron Facility (IUCF) is in the process of building the Midwest Proton Radiation Institute (MPRI). This involves refurbishing the 200MeV cyclotron and building new facilities for the purpose of providing clinical treatment of human cancer tumors. First patients are expected in the Spring of 2003. This paper presents the design and implementation to date of the controls…
▽ More
The Indiana University Cyclotron Facility (IUCF) is in the process of building the Midwest Proton Radiation Institute (MPRI). This involves refurbishing the 200MeV cyclotron and building new facilities for the purpose of providing clinical treatment of human cancer tumors. First patients are expected in the Spring of 2003. This paper presents the design and implementation to date of the controls, hardware and software, for both accelerator and treatment areas. Particular attention is placed on issues of personnel safety and control system security, development of inexpensive VMEbus boards with emphasis on the use of MicroChip PIC processors, beam diagnostics and monitoring and the use of commercial robots and vision systems for patient positioning.
△ Less
Submitted 9 November, 2001;
originally announced November 2001.