-
Microstructure-Resolved Degradation Simulation of Lithium-Ion Batteries in Space Applications
Authors:
Linda J. Bolay,
Tobias Schmitt,
Simon Hein,
Omar S. Mendoza-Hernandez,
Eiji Hosono,
Daisuke Asakura,
Koichi Kinoshita,
Hirofumi Matsuda,
Minoru Umeda,
Yoshitsugu Sone,
Arnulf Latz,
Birger Horstmann
Abstract:
In-orbit satellite REIMEI, developed by the Japan Aerospace Exploration Agency, has been relying on off-the-shelf Li-ion batteries since its launch in 2005. The performance and durability of Li-ion batteries is impacted by various degradation mechanisms, one of which is the growth of the solid-electrolyte interphase (SEI). In this article, we analyse the REIMEI battery and parameterize a full-cell…
▽ More
In-orbit satellite REIMEI, developed by the Japan Aerospace Exploration Agency, has been relying on off-the-shelf Li-ion batteries since its launch in 2005. The performance and durability of Li-ion batteries is impacted by various degradation mechanisms, one of which is the growth of the solid-electrolyte interphase (SEI). In this article, we analyse the REIMEI battery and parameterize a full-cell model with electrochemical cycling data, computer tomography images, and capacity fading experiments using image processing and surrogate optimization. We integrate a recent model for SEI growth into a full-cell model and simulate the degradation of batteries during cycling. To validate our model, we use experimental and in-flight data of the satellite batteries. Our combination of SEI growth model and microstructure-resolved 3D simulation shows, for the first time, experimentally observed inhomogeneities in the SEI thickness throughout the negative electrode for the degraded cells.
△ Less
Submitted 4 February, 2022; v1 submitted 4 November, 2021;
originally announced November 2021.
-
Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target
Authors:
M. Monterial,
K. T. Schmitt,
C. Prokop,
E. Leal-Cidoncha,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta
, et al. (15 additional authors not shown)
Abstract:
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio betwee…
▽ More
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.
△ Less
Submitted 9 July, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
Comparison of interface capturing methods for the simulation of two-phase flow in a unified low-Mach framework
Authors:
Victor Boniou,
Thomas Schmitt,
Aymeric Vié
Abstract:
This paper proposes a comparison of four popular interface capturing methods : the volume of fluid (VOF), the standard level set (SLS), the accurate conservative level set (ACLS) and the coupled level set and volume of fluid (CLSVOF). All methods are embedded into a unified low-Mach framework based on a Cartesian-grid finite-volume discretization. This framework includes a sharp transport of the i…
▽ More
This paper proposes a comparison of four popular interface capturing methods : the volume of fluid (VOF), the standard level set (SLS), the accurate conservative level set (ACLS) and the coupled level set and volume of fluid (CLSVOF). All methods are embedded into a unified low-Mach framework based on a Cartesian-grid finite-volume discretization. This framework includes a sharp transport of the interface, a wellbalanced surface tension discretization and a consistent mass and momentum transport which allows capillary-driven simulations with high density ratio. The comparison relies on shared metrics for geometrical accuracy, mass and momentum conservation which exposes the weakness and strengths of each method. Finally, the versatility and capabilities of the proposed solver are demonstrated on the simulation of a 3D head-on collision of two water droplets. Overall, all methods manage to retrieve reasonable results for all test cases presented. VOF, CLSVOF and ACLS tend to artificially create little structures while SLS suffers from conservation issues in the mesh resolution limit. This study leads us to the conclusion that CLSVOF is the most promising method for two-phase flow simulations in our specific framework because of its inherent conservation properties and topology accuracy.
△ Less
Submitted 31 May, 2021;
originally announced June 2021.
-
Disentangling X-ray dichroism and birefringence via high-purity polarimetry
Authors:
Annika T. Schmitt,
Yves Joly,
Kai S. Schulze,
Berit Marx-Glowna,
Ingo Uschmann,
Benjamin Grabiger,
Hendrik Bernhardt,
Robert Loetzsch,
Amélie Juhin,
Jérôme Debray,
Hans-Christian Wille,
Hasan Yavaş,
Gerhard G. Paulus,
Ralf Röhlsberger
Abstract:
High-brilliance synchrotron radiation sources have opened new avenues for X-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear X-ray polarizers in a crossed setting polarization extinction ratios down to 10$^{-10}$ can be achieved. This renders the method sensitive to probe tiniest optical anisotropies that would occur, for example, in strong-f…
▽ More
High-brilliance synchrotron radiation sources have opened new avenues for X-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear X-ray polarizers in a crossed setting polarization extinction ratios down to 10$^{-10}$ can be achieved. This renders the method sensitive to probe tiniest optical anisotropies that would occur, for example, in strong-field QED due to vacuum birefringence and dichroism. Here we show that high-purity polarimetry can be employed to reveal electronic anisotropies in condensed matter systems with utmost sensitivity and spectral resolution. Taking CuO and La$_2$CuO$_4$ as benchmark systems, we present a full characterization of the polarization changes across the Cu K-absorption edge and their separation into dichroic and birefringent contributions. At diffraction-limited synchrotron radiation sources and X-ray lasers, where polarization extinction ratios of 10$^{-12}$ can be achieved, our method has the potential to assess birefringence and dichroism of the quantum vacuum in extreme electromagnetic fields.
△ Less
Submitted 5 January, 2021; v1 submitted 27 February, 2020;
originally announced March 2020.
-
Derivation of a Local Volume-Averaged Model and a Stable Numerical Algorithm for Multi-Dimensional Simulations of Conversion Batteries
Authors:
Tobias Schmitt,
Arnulf Latz,
Birger Horstmann
Abstract:
In this article, we derive a general form of local volume-averaging theory and apply it to a model of zinc-air conversion batteries. Volume-averaging techniques are frequently used for the macroscopic description of micro-porous electrodes. We extend the existing method by including reactions between different phases and time-dependent volume fractions of the solid phases as these are continuously…
▽ More
In this article, we derive a general form of local volume-averaging theory and apply it to a model of zinc-air conversion batteries. Volume-averaging techniques are frequently used for the macroscopic description of micro-porous electrodes. We extend the existing method by including reactions between different phases and time-dependent volume fractions of the solid phases as these are continuously dissolved and reconstructed during operation of conversion batteries. We find that the constraint of incompressibility for multi-component fluids causes numerical instabilities in simulations of zinc-air battery cells. Therefore, we develop a stable sequential semi-implicit algorithm which converges against the fully implicit solution. Our method reduces the coupling of the variables by splitting the system of equations and introducing an additional iteration step.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.
-
1H(n,el) as a Cross Section Reference in a White Source Neutron Beam With the fissionTPC
Authors:
N. I. Walsh,
J. T. Barker,
N. S. Bowden,
K. J. Brewster,
R. J. Casperson,
T. Classen,
N. Fotiadis,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
D. Hensle,
C. R. Hicks,
D. Higgins,
L. D. Isenhower,
A. Kemnitz,
K. J. Kiesling,
J. King,
J. L. Klay,
J. Latta,
W. Loveland,
J. A. Magee,
M. P. Mendenhall,
M. Monterial,
S. Mosby
, et al. (11 additional authors not shown)
Abstract:
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such…
▽ More
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such as the H(n,el) cross section there is the potential to further reduce the evaluation uncertainties of the measured cross sections. In principle the fissionTPC could provide a unique measurement by simultaneously measuring both fission fragments and proton recoils over a large solid angle. We investigate one method with a hydrogenous gas target and with the neutron energy determined by the proton recoil kinematics. This method enables the measurement to be performed in a white-source neutron beam and with the current configuration of the fissionTPC. We show that while such a measurement is feasible in the energy range of 0.5 MeV to $\sim$10 MeV, uncertainties on the proton detection efficiency and the neutron energy resolution do not allow us to preform a fission ratio measurement to the desired precision. Utilizing either a direct measurement of the neutron time-of-flight for the recoil proton or a mono-energetic neutron source or some combination of both would provide a path to a sub-percent precision measurement.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
Zinc Electrode Shape-Change in Secondary Air Batteries: A 2D Modeling Approach
Authors:
Tobias Schmitt,
Tobias Arlt,
Ingo Manke,
Arnulf Latz,
Birger Horstmann
Abstract:
Zinc-air batteries offer large specific energy densities, while relying on abundant and non-toxic materials. In this paper, we present the first multi-dimensional simulations of zinc-air batteries. We refine our existing theory-based model of secondary zinc-air systems. The model comprises thermodynamically consistent multi-species transport in alkaline electrolytes, formation and dissolution of m…
▽ More
Zinc-air batteries offer large specific energy densities, while relying on abundant and non-toxic materials. In this paper, we present the first multi-dimensional simulations of zinc-air batteries. We refine our existing theory-based model of secondary zinc-air systems. The model comprises thermodynamically consistent multi-species transport in alkaline electrolytes, formation and dissolution of metallic zinc and passivating zinc oxide, as well as multi-phase coexistence in gas diffusion electrodes. For the first time, we simulate zinc shape-change during battery cycling by modeling convection of zinc solids. We validate our model with in-situ tomography of commercial button cells. Two-dimensional volume-averaged simulations of cell voltage and zinc electrode morphology during discharge agree with these measurements. Thus, we can study how electrolyte carbonation limits shelf-life and how zinc shape-change limits cycle-life. The charging current is found to be the major contributor to cycle-life limitations. Finally, we optimize initial anode structure and charge-discharge protocols for improved performance and cycle-ability.
△ Less
Submitted 1 March, 2019;
originally announced March 2019.
-
Polarization-dependent resonant inelastic X-ray scattering study at the Cu L and O K-edge of YBa$_2$Cu$_3$O$_{7-x}$
Authors:
Martin Magnuson,
Thorsten Schmitt,
Laurent Duda
Abstract:
We present a study on the high-Tc superconductor (HTSC) YBa2Cu3O7-x (YBCO) using polarization-dependent X-ray absorption and resonant inelastic X-ray scattering. High-resolution measurements using synchrotron-radiation are compared with calculations using a quasi-atomic multiplet approach performed at the Cu 2p3/2-edge of YBCO. We use a multiplet approach within the single impurity Anderson model…
▽ More
We present a study on the high-Tc superconductor (HTSC) YBa2Cu3O7-x (YBCO) using polarization-dependent X-ray absorption and resonant inelastic X-ray scattering. High-resolution measurements using synchrotron-radiation are compared with calculations using a quasi-atomic multiplet approach performed at the Cu 2p3/2-edge of YBCO. We use a multiplet approach within the single impurity Anderson model to reproduce and understand the character of the localized low-energy excitations in YBCO. We observe a distinct peak at about 0.5 eV in O K RIXS. This peak shows dependence on doping, incident energy, and momentum transfer that suggests that it has a different origin than the previously discussed cuprate bi-magnons. Therefore, we assign it to multi-magnon excitations between the Zhang Rice bands and/or the Upper Hubbard bands, respectively.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a MICROMEGAS-based TPC in a high-energy neutron beam
Authors:
Lucas Snyder,
Brett Manning,
Nathaniel S. Bowden,
Jeremy Bundgaard,
Robert J. Casperson,
Daniel A. Cebra,
Timothy Classen,
Dana L. Duke,
Joshua Gearhart,
Uwe Greife,
Christian Hagmann,
Michael Heffner,
David Hensle,
Daniel Higgins,
Donald Isenhower,
Jonathan King,
Jennifer L. Klay,
Verena Geppert-Kleinrath,
Walter Loveland,
Joshua A. Magee,
Michael P. Mendenhall,
Samuele Sangiorgio,
Brandon Seilhan,
Kyle T. Schmitt,
Fredrik Tovesson
, et al. (5 additional authors not shown)
Abstract:
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some dr…
▽ More
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. For a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Three-Dimensional Solid-State Lithium-Ion Batteries Fabricated Via Conformal Vapor-Phase Chemistry
Authors:
Alexander J. Pearse,
Thomas E. Schmitt,
Emily Sahadeo,
David Stewart,
Alexander C. Kozen,
Konstantinos Gerasopoulos,
A. Alec Talin,
Sang Bok Lee,
Gary Rubloff,
Keith E. Gregorczyk
Abstract:
Thin film solid state lithium-based batteries (TSSBs) are increasingly attractive for their intrinsic safety due to the use of a nonflammable solid electrolyte, cycling stability, and ability to be easily patterned in small form factors. However, existing methods for fabricating TSSBs are limited to planar geometries, which severely limits areal energy density when the electrodes are kept sufficie…
▽ More
Thin film solid state lithium-based batteries (TSSBs) are increasingly attractive for their intrinsic safety due to the use of a nonflammable solid electrolyte, cycling stability, and ability to be easily patterned in small form factors. However, existing methods for fabricating TSSBs are limited to planar geometries, which severely limits areal energy density when the electrodes are kept sufficiently thin to achieve high areal power. In order to circumvent this limitation, we report the first successful fabrication of fully conformal, 3D full cell TSSBs formed in micromachined silicon substrates with aspect ratios up to ~10 using atomic layer deposition (ALD) at low processing temperatures (at or below 250C) to deposit all active battery components. The cells utilize a prelithiated LiV$_2$O$_5$ cathode, a very thin (40 - 100 nm) LiPON-like lithium polyphosphazene (Li$_2$PO$_2$N) solid electrolyte, and a SnN$_x$ conversion anode, along with Ru and TiN current collectors. Planar all-ALD solid state cells deliver 37 μAh/cm$^2$μm normalized to the cathode thickness with only 0.02% per-cycle capacity loss for hundreds of cycles. Fabrication of full cells in 3D substrates increases the areal discharge capacity by up to a factor of 9.3x while simultaneously improving the rate performance, which corresponds well to trends identified by finite element simulations of the cathode film. This work shows that the exceptional conformality of ALD, combined with conventional semiconductor fabrication methods, provides an avenue for the successful realization of long-sought 3D TSSBs which provide power performance scaling in regimes inaccessible to planar form factor devices.
△ Less
Submitted 9 September, 2017;
originally announced September 2017.
-
Nanoscale Solid State Batteries Enabled By Thermal Atomic Layer Deposition of a Lithium Polyphosphazene Solid State Electrolyte
Authors:
Alexander J. Pearse,
Thomas E. Schmitt,
Elliot J. Fuller,
Farid El-Gabaly,
Chuan-Fu Lin,
Konstantinos Gerasopoulos,
Alexander C. Kozen,
A. Alec Talin,
Gary Rubloff,
Keith E. Gregorcyzck
Abstract:
Several active areas of research in novel energy storage technologies, including three-dimensional solid state batteries and passivation coatings for reactive battery electrode components, require conformal solid state electrolytes. We describe an atomic layer deposition (ALD) process for a member of the lithium phosphorus oxynitride (LiPON) family, which is employed as a thin film lithium-conduct…
▽ More
Several active areas of research in novel energy storage technologies, including three-dimensional solid state batteries and passivation coatings for reactive battery electrode components, require conformal solid state electrolytes. We describe an atomic layer deposition (ALD) process for a member of the lithium phosphorus oxynitride (LiPON) family, which is employed as a thin film lithium-conducting solid electrolyte. The reaction between lithium tert-butoxide (LiO$^t$Bu) and diethyl phosphoramidate (DEPA) produces conformal, ionically conductive thin films with a stoichiometry close to Li$_2$PO$_2$N between 250 and 300$^\circ$C. The P/N ratio of the films is always 1, indicative of a particular polymorph of LiPON which closely resembles a polyphosphazene. Films grown at 300$^\circ$C have an ionic conductivity of $6.51\:(\pm0.36)\times10^{-7}$ S/cm at 35$^\circ$C, and are functionally electrochemically stable in the window from 0 to 5.3V vs. Li/Li$^+$. We demonstrate the viability of the ALD-grown electrolyte by integrating it into full solid state batteries, including thin film devices using LiCoO$_2$ as the cathode and Si as the anode operating at up to 1 mA/cm$^2$. The high quality of the ALD growth process allows pinhole-free deposition even on rough crystalline surfaces, and we demonstrate the fabrication and operation of thin film batteries with the thinnest (<100nm) solid state electrolytes yet reported. Finally, we show an additional application of the moderate-temperature ALD process by demonstrating a flexible solid state battery fabricated on a polymer substrate.
△ Less
Submitted 13 February, 2017;
originally announced February 2017.
-
Ignition sequence of an annular multi-injector combustor
Authors:
Maxime Philip,
Matthieu Boileau,
Ronan Vicquelin,
Thomas Schmitt,
Daniel Durox,
Jean-François Bourgoin,
Sébastien Candel
Abstract:
Ignition is a critical process in combustion systems. In aeronautical combustors, altitude relight capacities are required in case of accidental extinction of the chamber. A simultaneous study of light-round ignition in an annular multi-injector combustor has been performed on the experimental and numerical sides. This effort allows a unique comparison to assess the reliability of Large-Eddy Simul…
▽ More
Ignition is a critical process in combustion systems. In aeronautical combustors, altitude relight capacities are required in case of accidental extinction of the chamber. A simultaneous study of light-round ignition in an annular multi-injector combustor has been performed on the experimental and numerical sides. This effort allows a unique comparison to assess the reliability of Large-Eddy Simulation (LES) in such a configuration. Results are presented in fluid dynamics videos.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.
-
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.
-
Numerical optimization of spherical VLS grating X-ray spectrometers
Authors:
V. N. Strocov,
T. Schmitt,
U. Flechsig,
L. Patthey,
G. S. Chiuzbăian
Abstract:
Operation of an X-ray spectrometer based on a spherical variable line spacing grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at photon energy of 930 eV (Cu L-edge). With this energy taken as refere…
▽ More
Operation of an X-ray spectrometer based on a spherical variable line spacing grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at photon energy of 930 eV (Cu L-edge). With this energy taken as reference, the VLS coefficients are optimized to cancel the lineshape asymmetry (mostly from the coma aberrations) as well as minimize the symmetric aberration broadening at large grating illuminations, dramatically increasing the aberration-limited vertical acceptance of the spectrometer. For any energy away from the reference, we evaluate corrections to the entrance arm and light incidence angle on the grating to maintain the exactly symmetric lineshape. Furthermore, we evaluate operational modes when these corrections are coordinated to maintain either energy independent focal curve inclination or maximal aberration-limited spectrometer acceptance. The results are supported by analytical evaluation of the coma term of the optical path function. Our analysis gives thus a recipe to design a high-resolution spherical VLS grating spectrometer operating with negligible aberrations at large acceptance and over extended energy range.
△ Less
Submitted 29 November, 2010;
originally announced November 2010.
-
Effects of coarse-graining on the scaling behavior of long-range correlated and anti-correlated signals
Authors:
Yinlin Xu,
Qianli D. Y. Ma,
Daniel T. Schmitt,
Pedro Bernaola-Galván,
Plamen Ch. Ivanov
Abstract:
We investigate how various coarse-graining methods affect the scaling properties of long-range power-law correlated and anti-correlated signals, quantified by the detrended fluctuation analysis. Specifically, for coarse-graining in the magnitude of a signal, we consider (i) the Floor, (ii) the Symmetry and (iii) the Centro-Symmetry coarse-graining methods. We find, that for anti-correlated signa…
▽ More
We investigate how various coarse-graining methods affect the scaling properties of long-range power-law correlated and anti-correlated signals, quantified by the detrended fluctuation analysis. Specifically, for coarse-graining in the magnitude of a signal, we consider (i) the Floor, (ii) the Symmetry and (iii) the Centro-Symmetry coarse-graining methods. We find, that for anti-correlated signals coarse-graining in the magnitude leads to a crossover to random behavior at large scales, and that with increasing the width of the coarse-graining partition interval $Δ$ this crossover moves to intermediate and small scales. In contrast, the scaling of positively correlated signals is less affected by the coarse-graining, with no observable changes when $Δ<1$, while for $Δ>1$ a crossover appears at small scales and moves to intermediate and large scales with increasing $Δ$. For very rough coarse-graining ($Δ>3$) based on the Floor and Symmetry methods, the position of the crossover stabilizes, in contrast to the Centro-Symmetry method where the crossover continuously moves across scales and leads to a random behavior at all scales, thus indicating a much stronger effect of the Centro-Symmetry compared to the Floor and the Symmetry methods. For coarse-graining in time, where data points are averaged in non-overlapping time windows, we find that the scaling for both anti-correlated and positively correlated signals is practically preserved. The results of our simulations are useful for the correct interpretation of the correlation and scaling properties of symbolic sequences.
△ Less
Submitted 19 February, 2010;
originally announced February 2010.
-
High-resolution soft-X-ray beamline ADRESS at Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies
Authors:
V. N. Strocov,
T. Schmitt,
U. Flechsig,
T. Schmidt,
A. Imhof,
Q. Chen,
J. Raabe,
R. Betemps,
D. Zimoch,
J. Krempasky,
A. Piazzalunga,
X. Wang,
M. Grioni,
L. Patthey
Abstract:
We describe the concepts and technical realization of the high-resolution soft-X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for Resonant Inelastic X-ray Scattering (RIXS) and Angle-Resolved Photoelectron Spectroscopy (ARPES). The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not on…
▽ More
We describe the concepts and technical realization of the high-resolution soft-X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for Resonant Inelastic X-ray Scattering (RIXS) and Angle-Resolved Photoelectron Spectroscopy (ARPES). The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not only the light polarization (including circular and 0-180 deg rotatable linear polarizations) but also the energy without changing the gap. The beamline optics is based on the well-established scheme of plane grating monochromator (PGM) operating in collimated light. The ultimate resolving power E/dE is above 33000 at 1 keV photon energy. The choice of blazed vs lamellar gratings and optimization of their profile parameters is described. Due to glancing angles on the mirrors as well as optimized groove densities and profiles of the gratings, high photon flux is achieved up to 1.0e13 photons/s/0.01%BW at 1 keV. Ellipsoidal refocusing optics used for the RIXS endstation demagnifies the vertical spot size down to 4 um, which allows slitless operation and thus maximal transmission of the high-resolution RIXS spectrometer delivering E/dE better than 11000 at 1 keV photon energy. Apart from the beamline optics, we give an overview of the control system, describe diagnostics and software tools, and discuss strategies used for the optical alignment. An introduction to the concepts and instrumental realization of the ARPES and RIXS endstations is given.
△ Less
Submitted 13 November, 2009;
originally announced November 2009.
-
Fractal scale-invariant and nonlinear properties of cardiac dynamics remain stable with advanced age: A new mechanistic picture of cardiac control in healthy elderly
Authors:
Daniel T. Schmitt,
Plamen Ch. Ivanov
Abstract:
We analyze heartbeat interval recordings from two independent databases: (a) 19 healthy young (avg. age 25.7 years) and 16 healthy elderly subjects (avg. age 73.8 years) during 2h under resting conditions from the Fantasia database; and (b) 29 healthy elderly subjects (avg. age 75.9 years) during $\approx{}8$h of sleep from the SHHS database, and the same subjects recorded 5 years later. We quan…
▽ More
We analyze heartbeat interval recordings from two independent databases: (a) 19 healthy young (avg. age 25.7 years) and 16 healthy elderly subjects (avg. age 73.8 years) during 2h under resting conditions from the Fantasia database; and (b) 29 healthy elderly subjects (avg. age 75.9 years) during $\approx{}8$h of sleep from the SHHS database, and the same subjects recorded 5 years later. We quantify: (1) The average heart rate <RR>; (2) the SD $σ_{RR}$ and $σ_{ΔRR}$ of the heartbeat intervals RR and their increments $ΔRR$; (3) the long-range correlations in RR as measured by the scaling exponent $α_{RR}$ using the Detrended Fluctuation Analysis; (4) fractal linear and nonlinear properties as represented by the scaling exponents $α^{sign}$ and $α^{mag}$ for the time series of the sign and magnitude of $ΔRR$; (5) the nonlinear fractal dimension $D(k)$ of $RR$ using the Fractal Dimension Analysis. We find: (1) No significant difference in $\left<RR\right>$ (P>0.05); (2) a significant difference in $σ_{RR}$ and $σ_{ΔRR}$ for the Fantasia groups (P<10^{-4}) but no significant change with age between the elderly SHHS groups (P>0.5); (3) no significant change in the fractal measures $α_{RR}$ (P>0.15), $α^{sign}$ (P>0.2), $α^{mag}$ (P>0.3), and D(k) with age. Our findings do not support the hypothesis that fractal linear and nonlinear characteristics of heartbeat dynamics break down with advanced age in healthy subjects. While our results indeed show a reduced SD of heartbeat fluctuations with advanced age, the inherent temporal fractal and nonlinear organization of these fluctuations remains stable.
△ Less
Submitted 9 December, 2007;
originally announced December 2007.