Technical recommendation on multiplex MR elastography for tomographic mapping of abdominal stiffness with a focus on the pancreas and pancreatic ductal adenocarcinoma
Authors:
Jakob Schattenfroh,
Salma Almutawakel,
Jan Bieling,
Johannes Castelein,
Melanie Estrella,
Philippe Garteiser,
Viktor Hartung,
Karl H. Hillebrandt,
Adrian T. Huber,
Laura Körner,
Thomas Kröncke,
Thomas Malinka,
Hans-Jonas Meyer,
Tom Meyer,
Uwe Pelzer,
Felix Pfister,
Igor M. Sauer,
Anna Speth,
Bernard E. Van Beers,
Carsten Warmuth,
Nienke P. M. Wassenaar,
Yanglei Wu,
Rolf Reiter,
Ingolf Sack
Abstract:
Objectives: MR elastography (MRE) offers valuable mechanical tissue characterization, however, in deep abdominal organs like the pancreas conventional single-driver, single-frequency approaches often fail. This study evaluates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations.
Methods: This study used single-shot spin-echo MRE in 18 healthy vol…
▽ More
Objectives: MR elastography (MRE) offers valuable mechanical tissue characterization, however, in deep abdominal organs like the pancreas conventional single-driver, single-frequency approaches often fail. This study evaluates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations.
Methods: This study used single-shot spin-echo MRE in 18 healthy volunteers targeting the liver, pancreas, kidneys, and spleen. Each healthy volunteer underwent 16 MRE examinations with different sets of four vibration frequencies (30-60 Hz) and four driver combinations, and an additional null experiment without vibrations. Further, a cohort of 14 patients with pancreatic ductal adenocarcinoma (PDAC) were retrospectively assessed. The quality of shear-wave fields and stiffness maps was assessed by displacement amplitudes and image sharpness.
Results: In healthy volunteers, abdominal coverage with displacement amplitudes above the pre-determined noise level of 4 μm varied between MRE configurations: 24.2% ([0.0%-56.2%], single-driver, 60 Hz), 66.9% ([24.8%-97.7%], single-driver, 30-60 Hz), 70.2% ([0.0%-92.5%], multi-driver, 60 Hz) and 99.9% ([89.4%-100%], multi-driver, 30-60 Hz). In the pancreas, >60% coverage was achieved in all subjects using four drivers and multiple frequencies. This was achieved in only 2/18 subjects using single-driver/single-frequency MRE. Patients with PDAC had 99.1% [91.4%-100%] coverage in the pancreas and 96.3% [63.1%-100%] abdominal coverage (multi-driver, 30-60 Hz).
Conclusion: MRE with four drivers and multiple vibration frequencies between 30-60 Hz enables tomographic mapping of tissue stiffness across the entire abdomen, including the pancreas. Multiplex MRE offers a promising approach for generating detailed images of abdominal stiffness, potentially enhancing clinical diagnostics for abdominal and pancreatic diseases.
△ Less
Submitted 26 May, 2025;
originally announced May 2025.