Road to micron resolution with a color X-ray camera -- polycapillary optics characterization
Authors:
Stanisław H. Nowak,
Marko Petric,
Josef Buchriegler,
Aniouar Bjeoumikhov,
Zemfira Bjeoumikhov,
Johannes von Borany,
Frans Munnik,
Martin Radtke,
Axel D. Renno,
Uwe Reinholz,
Oliver Scharf,
Joachim Tilgner,
Reiner Wedell
Abstract:
In a color X-ray camera, spatial resolution is achieved by means of a polycapillary optic conducting X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD matrix. At present, the resolution limit of color X-ray camera systems can go down to several microns and is mainly restricted to pixel dimensions. The recent development of an efficient subpixel resolution a…
▽ More
In a color X-ray camera, spatial resolution is achieved by means of a polycapillary optic conducting X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD matrix. At present, the resolution limit of color X-ray camera systems can go down to several microns and is mainly restricted to pixel dimensions. The recent development of an efficient subpixel resolution algorithm allows a release from pixel size, limiting the resolution only to the quality of the optics. In this work polycapillary properties that influence the spatial resolution are systematized and assessed both theoretically and experimentally. It is demonstrated that with the current technological level reaching one micron resolution is challenging, but possible.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
Sub-pixel resolution with color X-ray camera SLcam(R)
Authors:
Stanisław H. Nowak,
Aniouar Bjeoumikhov,
Johannes von Borany,
Josef Buchriegler,
Frans Munnik,
Marko Petric,
Martin Radtke,
Axel D. Renno,
Uwe Reinholz,
Oliver Scharf,
Reiner Wedell
Abstract:
The color X-ray camera SLcam(R) is a full-field, single photon detector providing scanning free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD. Applying sub-pixel resolution, signals from individual capillary channels can be distingui…
▽ More
The color X-ray camera SLcam(R) is a full-field, single photon detector providing scanning free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a CCD. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Accordingly the SLcam(R) spatial resolution can be released from pixel size being confined rather to a diameter of individual polycapillary channels. In this work a new approach to sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed.
△ Less
Submitted 27 January, 2015;
originally announced January 2015.
-
The SLcam: A full-field energy dispersive X-ray camera
Authors:
A. Bjeoumikhov,
G. Buzanich,
N. Langhoff,
I. Ordavo,
M. Radtke,
U. Reinholz,
H. Riesemeier,
O. Scharf,
H. Soltau,
R. Wedell
Abstract:
The color X-ray camera (SLcam) is a full-field single photon imager. As stand-alone camera, it is applicable for energy and space-resolved X-ray detection measurements. The exchangeable poly-capillary optics in front of a beryllium entrance window conducts X-ray photons from the probe to distinguished energy dispersive pixels on a pnCCD. The dedicated software enables the acquisition and the onlin…
▽ More
The color X-ray camera (SLcam) is a full-field single photon imager. As stand-alone camera, it is applicable for energy and space-resolved X-ray detection measurements. The exchangeable poly-capillary optics in front of a beryllium entrance window conducts X-ray photons from the probe to distinguished energy dispersive pixels on a pnCCD. The dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the element distribution in a sample. No scanning system is employed. A first elemental composition image of the sample is visible within minutes while statistics is improving in the course of time. Straight poly-capillary optics allows for 1:1 imaging with a space resolution of 50 um and no limited depth of sharpness, ideal to map uneven objects. Using conically shaped optics, a magnification of 6 times was achieved with a space resolution of 10 um. We present a measurement with a laboratory source showing the camera capability to perform fast full-field X-ray Fluorescence (FF-XRF) imaging with an easy, portable and modular setup.
△ Less
Submitted 16 October, 2012;
originally announced October 2012.
-
Isotope shift in the Sulfur electron affinity: observation and theory
Authors:
Thomas Carette,
Cyril Drag,
Oliver Scharf,
Christophe Blondel,
Christian Delsart,
Charlotte Froese Fischer,
Michel Godefroid
Abstract:
The electron affinities eA(S) are measured for the two isotopes 32S and 34S (16752.9753(41) and 16752.9776(85) cm-1, respectively). The isotope shift in the electron affinity is found to be positive, eA(34S)-eA(32S) = +0.0023(70) cm-1, but the uncertainty allows for the possibility that it may be either "normal" (eA(34S) > eA(32S)) or "anomalous" (eA(34S) < eA(32S)). The isotope shift is estimat…
▽ More
The electron affinities eA(S) are measured for the two isotopes 32S and 34S (16752.9753(41) and 16752.9776(85) cm-1, respectively). The isotope shift in the electron affinity is found to be positive, eA(34S)-eA(32S) = +0.0023(70) cm-1, but the uncertainty allows for the possibility that it may be either "normal" (eA(34S) > eA(32S)) or "anomalous" (eA(34S) < eA(32S)). The isotope shift is estimated theoretically using elaborate correlation models, monitoring the electron affinity and the mass polarization term expectation value. The theoretical analysis predicts a very large specific mass shift that counterbalances the normal mass shift and produces an anomalous isotope shift, eA(34S)-eA(32S) = - 0.0053(24) cm-1. The observed and theoretical residual isotope shifts agree with each other within the estimated uncertainties.
△ Less
Submitted 5 February, 2010;
originally announced February 2010.
-
Multiconfiguration electron density function for the ATSP2K-package
Authors:
A. Borgoo,
O. Scharf,
G. Gaigalas,
M. Godefroid
Abstract:
A new ATSP2K module is presented for evaluating the electron density function of any multiconfiguration Hartree-Fock or configuration interaction wave function in the non relativistic or relativistic Breit-Pauli approximation. It is first stressed that the density function is not a priori spherically symmetric in the general open shell case. Ways of building it as a spherical symmetric function…
▽ More
A new ATSP2K module is presented for evaluating the electron density function of any multiconfiguration Hartree-Fock or configuration interaction wave function in the non relativistic or relativistic Breit-Pauli approximation. It is first stressed that the density function is not a priori spherically symmetric in the general open shell case. Ways of building it as a spherical symmetric function are discussed, from which the radial electron density function emerges. This function is written in second quantized coupled tensorial form for exploring the atomic spherical symmetry. The calculation of its expectation value is performed using the angular momentum theory in orbital, spin, and quasispin spaces, adopting a generalized graphical technique. The natural orbitals are evaluated from the diagonalization of the density matrix.
△ Less
Submitted 16 July, 2009;
originally announced July 2009.
-
On the fine structure photodetachment intensities using the irreducible tensorial expression of second quantization operators
Authors:
Oliver Scharf,
Michel R. Godefroid
Abstract:
The branching ratios of the fine-structure photodetachment intensities of S- have been calculated by Blondel et al. (J. Phys. B 39(2006)1409) using the standard irreducible tensorial operator techniques. They observed that the relative intensities were consistent with the well known Engelking-Lineberger formula (Phys. Rev. A19(1979)149) derived from the fractional parentage approach, and qualifi…
▽ More
The branching ratios of the fine-structure photodetachment intensities of S- have been calculated by Blondel et al. (J. Phys. B 39(2006)1409) using the standard irreducible tensorial operator techniques. They observed that the relative intensities were consistent with the well known Engelking-Lineberger formula (Phys. Rev. A19(1979)149) derived from the fractional parentage approach, and qualified this agreement as remarkable. In the present paper, we show that it can be understood from a general interesting angular momentum expression relating a weighted sum of squared 9j-symbols and a weighted sum of products of squared 6j-symbols. We also point out that the standard approach result is a special case of the photodetachment cross sections parametrization by Pan and Starace (Phys. Rev. A47(1993)295) who already established the link with the Engelking-Lineberger's result. The present work provides a new, elegant and deep link between the two formalisms, thanks to the irreducible tensorial expression of the second quantization form of the electric dipole transition operator.
△ Less
Submitted 26 August, 2008;
originally announced August 2008.