Skip to main content

Showing 1–2 of 2 results for author: Scantlebury-Smead, L

Searching in archive physics. Search in all archives.
.
  1. arXiv:2112.12763  [pdf, other

    physics.ins-det hep-ex

    Microchannel cooling for the LHCb VELO Upgrade I

    Authors: Oscar Augusto De Aguiar Francisco, Wiktor Byczynski, Kazu Akiba, Claudia Bertella, Alexander Bitadze, Matthew Brock, Bartosz Bulat, Guillaume Button, Jan Buytaert, Stefano De Capua, Riccardo Callegari, Christine Castellana, Andrea Catinaccio, Catherine Charrier, Collette Charvet, Victor Coco, Paula Collins, Jordan Degrange, Raphael Dumps, Diego Alvarez Feito, Julian Freestone, Mariusz Jedrychowski, Vinicius Franco Lima, Abraham Gallas, Wouter Hulsbergen , et al. (35 additional authors not shown)

    Abstract: The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures… ▽ More

    Submitted 23 December, 2021; originally announced December 2021.

    Comments: 31 pages, 27 figures

    Report number: LHCb-PUB-2021-010

  2. arXiv:2006.09559  [pdf, other

    physics.ins-det hep-ex

    The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform

    Authors: P. Kopciewicz, T. Szumlak, M. Majewski, K. Akiba, O. Augusto, J. Back, D. S. Bobulska, G. Bogdanova, S. Borghi, T. Bowcock, J. Buytaert, E. Lemos Cid, V. Coco, P. Collins, E. Dall'Occo, K. de Bruyn, S. de Capua, F. Dettori, K. Dreimanis, D. Dutta, L. Eklund, T. Evans, M. Ferro-Luzzi W. Funk, L. Meyer Garcia, O. Boente GarcĂ­a , et al. (41 additional authors not shown)

    Abstract: The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in… ▽ More

    Submitted 22 July, 2022; v1 submitted 16 June, 2020; originally announced June 2020.

    Journal ref: Journal of Instrumentation (JINST), Volume 15, June 2020