Direct observation of the exciton polaron by serial femtosecond crystallography on single CsPbBr$_3$ quantum dots
Authors:
Zhou Shen,
Margarita Samoli,
Onur Erdem,
Johan Bielecki,
Amit Kumar Samanta,
Juncheng E,
Armando Estillore,
Chan Kim,
Yoonhee Kim,
Jayanath Koliyadu,
Romain Letrun,
Federico Locardi,
Jannik Lübke,
Abhishek Mall,
Diogo Melo,
Grant Mills,
Safi Rafie-Zinedine,
Adam Round,
Tokushi Sato,
Raphael de Wijn,
Tamme Wollweber,
Lena Worbs,
Yulong Zhuang,
Adrian P. Mancuso,
Richard Bean
, et al. (6 additional authors not shown)
Abstract:
The outstanding opto-electronic properties of lead halide perovskites have been related to the formation of polarons. Nevertheless, the observation of the atomistic deformation brought about by one electron-hole pair in these materials has remained elusive. Here, we measure the diffraction patterns of single CsPbBr$_3$ quantum dots (QDs) with and without resonant excitation in the single exciton l…
▽ More
The outstanding opto-electronic properties of lead halide perovskites have been related to the formation of polarons. Nevertheless, the observation of the atomistic deformation brought about by one electron-hole pair in these materials has remained elusive. Here, we measure the diffraction patterns of single CsPbBr$_3$ quantum dots (QDs) with and without resonant excitation in the single exciton limit using serial femtosecond crystallography (SFX). By reconstructing the 3D differential diffraction pattern, we observe small shifts of the Bragg peaks indicative of a crystal-wide deformation field. Building on DFT calculations, we show that these shifts are consistent with the lattice distortion induced by a delocalized electron and a localized hole, forming a mixed large/small exciton polaron. This result creates a clear picture of the polaronic deformation in CsPbBr$_3$ QDs, highlights the exceptional sensitivity of SFX to lattice distortions in few-nanometer crystallites, and establishes an experimental platform for future studies of electron-lattice interactions.
△ Less
Submitted 4 February, 2025;
originally announced February 2025.
-
An improved numerical simulation methodology for nanoparticle injection through aerodynamic lens systems
Authors:
Surya Kiran Peravali,
Amit K. Samanta,
Muhamed Amin,
Philipp Neumann,
Jochen Küpper,
Michael Breuer
Abstract:
Aerosol injectors applied in single-particle diffractive imaging experiments demonstrated their potential in efficiently delivering nanoparticles with high density. Continuous optimization of injector design is crucial for achieving high-density particle streams, minimizing background gas, enhancing X-ray interactions, and generating high-quality diffraction patterns. We present an updated simulat…
▽ More
Aerosol injectors applied in single-particle diffractive imaging experiments demonstrated their potential in efficiently delivering nanoparticles with high density. Continuous optimization of injector design is crucial for achieving high-density particle streams, minimizing background gas, enhancing X-ray interactions, and generating high-quality diffraction patterns. We present an updated simulation framework designed for the fast and effective exploration of the experimental parameter space to enhance the optimization process. The framework includes both the simulation of the carrier gas and the particle trajectories within injectors and their expansion into the experimental vacuum chamber. A hybrid molecular-continuum-simulation method (DSMC/CFD) is utilized to accurately capture the multi-scale nature of the flow. The simulation setup, initial benchmark results of the coupled approach, and the validation of the entire methodology against experimental data are presented.
△ Less
Submitted 24 January, 2025;
originally announced January 2025.
-
Accuracy and Performance Evaluation of Low Density Internal and External Flow Predictions using CFD and DSMC
Authors:
Surya Kiran Peravali,
Vahid Jafari,
Amit K. Samanta,
Jochen Küpper,
Muhamed Amin,
Philipp Neumann,
Michael Breuer
Abstract:
The Direct Simulation Monte Carlo (DSMC) method was widely used to simulate low density gas flows with large Knudsen numbers. However, DSMC encounters limitations in the regime of lower Knudsen numbers (Kn<0.1). In such cases, approaches from classical computational fluid dynamics (CFD) relying on the continuum assumption are preferred, offering accurate solutions at acceptable computational costs…
▽ More
The Direct Simulation Monte Carlo (DSMC) method was widely used to simulate low density gas flows with large Knudsen numbers. However, DSMC encounters limitations in the regime of lower Knudsen numbers (Kn<0.1). In such cases, approaches from classical computational fluid dynamics (CFD) relying on the continuum assumption are preferred, offering accurate solutions at acceptable computational costs. In experiments aimed at imaging aerosolized nanoparticles in vacuo a wide range of Knudsen numbers occur, which motivated the present study on the analysis of the advantages and drawbacks of DSMC and CFD simulations of rarefied flows in terms of accuracy and computational effort. Furthermore, the potential of hybrid methods is evaluated. For this purpose, DSMC and CFD simulations of the flow inside a convergent-divergent nozzle (internal expanding flow) and the flow around a conical body (external shock generating flow) were carried out. CFD simulations utilize the software OpenFOAM and the DSMC solution is obtained using the software SPARTA. The results of these simulation techniques are evaluated by comparing them with experimental data (1), evaluating the time-to-solution (2) and the energy consumption (3), and assessing the feasibility of hybrid CFD-DSMC approaches (4).
Keywords: DSMC; SPARTA; Continuum assumption; Transition regime; Rarefied flow; high-performance computing
△ Less
Submitted 8 April, 2024; v1 submitted 24 January, 2024;
originally announced January 2024.
-
Laser-induced alignment of nanoparticles and macromolecules for single-particle-imaging applications
Authors:
Muhamed Amin,
Jean-Michel Hartmann,
Amit K. Samanta,
Jochen Küpper
Abstract:
Laser-induced alignment of particles and molecules was long envisioned to support three-dimensional structure determination using "single-molecule diffraction" with x-ray free-electron lasers [PRL 92, 198102 (2004)]. However, the alignment of isolated macromolecules has not yet been demonstrated, also because quantitative modeling is very expensive. We computationally demonstrated that the alignme…
▽ More
Laser-induced alignment of particles and molecules was long envisioned to support three-dimensional structure determination using "single-molecule diffraction" with x-ray free-electron lasers [PRL 92, 198102 (2004)]. However, the alignment of isolated macromolecules has not yet been demonstrated, also because quantitative modeling is very expensive. We computationally demonstrated that the alignment of nanorods and proteins is possible with standard laser technology. We performed a comprehensive analysis on the dependence of the degree of alignment on molecular properties and experimental details, e.g., particle temperature and laser-pulse energy. Considering the polarizability anisotropy of about 150,000 proteins, our analysis revealed that most of these proteins can be aligned using realistic experimental parameters.
△ Less
Submitted 4 February, 2025; v1 submitted 9 June, 2023;
originally announced June 2023.
-
Time-resolved single-particle x-ray scattering reveals electron-density as coherent plasmonic-nanoparticle-oscillation source
Authors:
D. Hoeing,
R. Salzwedel,
L. Worbs,
Y. Zhuang,
A. K. Samanta,
J. Lübke,
A. Estillore,
K. Dlugolecki,
C. Passow,
B. Erk,
N. Ekanayaje,
D. Ramm,
J. Correa,
C. C. Papadooulou,
A. T. Noor,
F. Schulz,
M. Selig,
A. Knorr,
K. Ayyer,
J. Küpper,
H. Lange
Abstract:
Dynamics of optically-excited plasmonic nanoparticles are presently understood as a series of sequential scattering events, involving thermalization processes after pulsed optical excitation. One important step is the initiation of nanoparticle breathing oscillations. According to established experiments and models, these are caused by the statistical heat transfer from thermalized electrons to th…
▽ More
Dynamics of optically-excited plasmonic nanoparticles are presently understood as a series of sequential scattering events, involving thermalization processes after pulsed optical excitation. One important step is the initiation of nanoparticle breathing oscillations. According to established experiments and models, these are caused by the statistical heat transfer from thermalized electrons to the lattice. An additional contribution by hot electron pressure has to be included to account for phase mismatches that arise from the lack of experimental data on the breathing onset. We used optical transient-absorption spectroscopy and time-resolved single-particle x-ray-diffractive imaging to access the excited electron system and lattice. The time-resolved single-particle imaging data provided structural information directly on the onset of the breathing oscillation and confirmed the need for an additional excitation mechanism to thermal expansion, while the observed phase-dependence of the combined structural and optical data contrasted previous studies. Therefore, we developed a new model that reproduces all our experimental observations without using fit parameters. We identified optically-induced electron density gradients as the main driving source.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging
Authors:
Yulong Zhuang,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (17 additional authors not shown)
Abstract:
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orien…
▽ More
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
Charge-state distribution of aerosolized nanoparticles
Authors:
Jannik Lübke,
Nils Roth,
Lena Worbs,
Daniel A. Horke,
Armando D. Estillore,
Amit K. Samanta,
Jochen Küpper
Abstract:
In single particle imaging experiments, beams of individual nanoparticles are exposed to intense pulses of x-rays from free-electron lasers to record diffraction patterns of single, isolated molecules. The reconstruction for structure determination relies on signal from many identical particles. Therefore, well-defined-sample delivery conditions are desired in order to achieve sample uniformity, i…
▽ More
In single particle imaging experiments, beams of individual nanoparticles are exposed to intense pulses of x-rays from free-electron lasers to record diffraction patterns of single, isolated molecules. The reconstruction for structure determination relies on signal from many identical particles. Therefore, well-defined-sample delivery conditions are desired in order to achieve sample uniformity, including avoidance of charge polydispersity. We have observed charging of 220 nm polystyrene particles in an aerosol beam created by a gas-dynamic virtual nozzle focusing technique, without intentional charging of the nanoparticles. Here, we present a deflection method for detecting and characterizing the charge states of a beam of aerosolized nanoparticles. Our analysis of the observed charge-state distribution using optical light-sheet localization microscopy and quantitative particle trajectory simulations is consistent with previous descriptions of skewed charging probabilities of triboelectrically charged nanoparticles.
△ Less
Submitted 10 August, 2021;
originally announced August 2021.
-
Optimizing the geometry of aerodynamic lens injectors for single-particle coherent diffractive imaging of gold nanoparticles
Authors:
Lena Worbs,
Nils Roth,
Jannik Lübke,
Armando D. Estillore,
P. Lourdu Xavier,
Amit K. Samanta,
Jochen Küpper
Abstract:
Single-particle x-ray diffractive imaging (SPI) of small (bio-)nanoparticles (NPs) requires optimized injectors to collect sufficient diffraction patterns to reconstruct the NP structure with high resolution. Typically, aerodynamic-lens-stack injectors are used for single NP injection. However, current injectors were developed for larger NPs ($\gg\!100$ nm) and their ability to generate high-densi…
▽ More
Single-particle x-ray diffractive imaging (SPI) of small (bio-)nanoparticles (NPs) requires optimized injectors to collect sufficient diffraction patterns to reconstruct the NP structure with high resolution. Typically, aerodynamic-lens-stack injectors are used for single NP injection. However, current injectors were developed for larger NPs ($\gg\!100$ nm) and their ability to generate high-density NP beams suffers with decreasing NP size. Here, an aerodynamic-lens-stack injector with variable geometry and the geometry-optimization procedure are presented. The optimization for 50 nm gold NP (AuNP) injection using a numerical simulation infrastructure capable of calculating the carrier gas flow and the particle trajectories through the injector is introduced. The simulations are experimentally validated using spherical AuNPs and sucrose NPs. In addition, the optimized injector is compared to the standard-installation "Uppsala-injector" for AuNPs and results for these heavy particles show a shift in the particle-beam focus position rather than a change in beam size, which results in a lower gas background for the optimized injector. Optimized aerodynamic-lens stack injectors will allow to increase NP beam density, reduce the gas background, discover the limits of current injectors, and contribute to structure determination of small NPs using SPI.
△ Less
Submitted 31 May, 2021;
originally announced May 2021.
-
New aerodynamic lens injector for single particle diffractive imaging
Authors:
Nils Roth,
Daniel A. Horke,
Jannik Lübke,
Amit K. Samanta,
Armando D. Estillore,
Lena Worbs,
Nicolai Pohlman,
Kartik Ayyer,
Andrew Morgan,
Holger Fleckenstein,
Martin Domaracky,
Benjamin Erk,
Christopher Passow,
Jonathan Correa,
Oleksandr Yefanov,
Anton Barty,
Saša Bajt,
Richard A. Kirian,
Henry N. Chapman,
Jochen Küpper
Abstract:
An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction p…
▽ More
An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction patterns of polystyrene spheres are modeled using Mie scattering, which allowed for the characterization of the particle beam under diffractive-imaging conditions and yield good agreement with particle-trajectory simulations.
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
Frequency Estimation of Gravitational Waves from a Binary Black Hole Merger
Authors:
Varun Nagesh Jolly Behera,
Anik Kumar Samanta,
Aurobinda Routray
Abstract:
This is a collection of literature reviews and some initial work on the estimation of the frequency of gravitational waves from a binary black hole merger for low SNR. This document provides a starting point, with a broad overview of the prerequisites required for the follow-up work on frequency estimation.
This is a collection of literature reviews and some initial work on the estimation of the frequency of gravitational waves from a binary black hole merger for low SNR. This document provides a starting point, with a broad overview of the prerequisites required for the follow-up work on frequency estimation.
△ Less
Submitted 9 November, 2020;
originally announced November 2020.
-
3D diffractive imaging of nanoparticle ensembles using an X-ray laser
Authors:
Kartik Ayyer,
P. Lourdu Xavier,
Johan Bielecki,
Zhou Shen,
Benedikt J. Daurer,
Amit K. Samanta,
Salah Awel,
Richard Bean,
Anton Barty,
Tomas Ekeberg,
Armando D. Estillore,
Klaus Giewekemeyer,
Mark S. Hunter,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letruin,
Jannik Lübke,
Andrew J. Morgan,
Nils Roth,
Tokushi Sato,
Marcin Sikorski,
Florian Schulz
, et al. (12 additional authors not shown)
Abstract:
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 150…
▽ More
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Microscopic force for aerosol transport
Authors:
Nils Roth,
Muhamed Amin,
Amit K. Samanta,
Jochen Küpper
Abstract:
A key ingredient for single particle diffractive imaging experiments is the successful and efficient delivery of sample. Current sample-delivery methods are based on aerosol injectors in which the samples are driven by fluid-dynamic forces. These are typically simulated using Stokes' drag forces and for micrometer-size or smaller particles, the Cunningham correction factor is applied. This is not…
▽ More
A key ingredient for single particle diffractive imaging experiments is the successful and efficient delivery of sample. Current sample-delivery methods are based on aerosol injectors in which the samples are driven by fluid-dynamic forces. These are typically simulated using Stokes' drag forces and for micrometer-size or smaller particles, the Cunningham correction factor is applied. This is not only unsatisfactory, but even using a temperature dependent formulation it fails at cryogenic temperatures. Here we propose the use of a direct computation of the force, based on Epstein's formulation, that allows for high relative velocities of the particles to the gas and also for internal particle temperatures that differ from the gas temperature. The new force reproduces Stokes' drag force for conditions known to be well described by Stokes' drag. Furthermore, it shows excellent agreement to experiments at 4 K, confirming the improved descriptive power of simulations over a wide temperature range.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
Controlled beams of shockfrozen, isolated, biological and artificial nanoparticles
Authors:
Amit K. Samanta,
Muhamed Amin,
Armando D. Estillore,
Nils Roth,
Lena Worbs,
Daniel A. Horke,
Jochen Küpper
Abstract:
X-ray free-electron lasers (XFELs) promise the diffractive imaging of single molecules and nanoparticles with atomic spatial resolution. This relies on the averaging of millions of diffraction patterns of identical particles, which should ideally be isolated in the gas phase and preserved in their native structure. Here, we demonstrated that polystyrene nanospheres and Cydia pomonella granulovirus…
▽ More
X-ray free-electron lasers (XFELs) promise the diffractive imaging of single molecules and nanoparticles with atomic spatial resolution. This relies on the averaging of millions of diffraction patterns of identical particles, which should ideally be isolated in the gas phase and preserved in their native structure. Here, we demonstrated that polystyrene nanospheres and Cydia pomonella granulovirus can be transferred into the gas phase, isolated, and very quickly shockfrozen, i.e. cooled to 4~K within microseconds in a helium-buffer-gas cell, much faster than state-of-the-art approaches. Nanoparticle beams emerging from the cell were characterized using particle-localization microscopy with light-sheet illumination, which allowed for the full reconstruction of the particle beams, focused to $<100\:μ\text{m}$, as well as for the determination of particle flux and number density. The experimental results were quantitatively reproduced and rationalized through particle-trajectory simulations. We propose an optimized setup with cooling rates for few-nanometers particles on nanoseconds timescales. The produced beams of shockfrozen isolated nanoparticles provide a breakthrough in sample delivery, e.g. for diffractive imaging and microscopy or low-temperature nanoscience.
△ Less
Submitted 3 April, 2020; v1 submitted 28 October, 2019;
originally announced October 2019.
-
Light-sheet imaging for the recording of transverse absolute density distributions of gas-phase particle-beams from nanoparticle injectors
Authors:
Lena Worbs,
Jannik Lübke,
Nils Roth,
Amit K. Samanta,
Daniel A. Horke,
Jochen Küpper
Abstract:
Imaging biological molecules in the gas-phase requires novel sample delivery methods, which generally have to be characterized and optimized to produce high-density particle beams. A non-destructive characterization method of the transverse particle beam profile is presented. It enables the characterization of the particle beam in parallel to the collection of, for instance, x-ray-diffraction patt…
▽ More
Imaging biological molecules in the gas-phase requires novel sample delivery methods, which generally have to be characterized and optimized to produce high-density particle beams. A non-destructive characterization method of the transverse particle beam profile is presented. It enables the characterization of the particle beam in parallel to the collection of, for instance, x-ray-diffraction patterns. As a rather simple experimental method, it requires the generation of a small laser-light sheet using a cylindrical telescope and a microscope. The working principle of this technique was demonstrated for the characterization of the fluid-dynamic-focusing behavior of 220 nm polystyrene beads as prototypical nanoparticles. The particle flux was determined and the velocity distribution was calibrated using Mie-scattering calculations.
△ Less
Submitted 19 September, 2019;
originally announced September 2019.
-
Optimized cell geometry for buffer-gas-cooled molecular-beam sources
Authors:
Vijay Singh,
Amit K. Samanta,
Nils Roth,
Daniel Gusa,
Tim Ossenbrüggen,
Igor Rubinsky,
Daniel A. Horke,
Jochen Küpper
Abstract:
We have designed, constructed, and commissioned a cryogenic helium buffer-gas source for producing a cryogenially-cooled molecular beam and evaluated the effect of different cell geometries on the intensity of the produced molecular beam, using ammonia as a test molecule. Planar and conical entrance and exit geometries are tested. We observe a three fold enhancement in the NH$_3$ signal for a cell…
▽ More
We have designed, constructed, and commissioned a cryogenic helium buffer-gas source for producing a cryogenially-cooled molecular beam and evaluated the effect of different cell geometries on the intensity of the produced molecular beam, using ammonia as a test molecule. Planar and conical entrance and exit geometries are tested. We observe a three fold enhancement in the NH$_3$ signal for a cell with planar-entrance and conical-exit geometry, compared to that for a typically used `box'-like geometry with planar entrance and exit. These observations are rationalized by flow-field simulations for the different buffer-gas cell geometries. The full thermalization of molecules with the helium buffer-gas is confirmed through rotationally-resolved REMPI spectra yielding a rotational temperature of 5 K.
△ Less
Submitted 26 February, 2018; v1 submitted 31 January, 2018;
originally announced January 2018.