-
Quantum Dot Based Chromatic Calorimetry: A proposal
Authors:
Yacine Haddad,
Devanshi Arora,
Etiennette Auffray,
Michael Doser,
Matteo Salomoni,
Michele Weber
Abstract:
Chromatic calorimetry introduces a novel approach to calorimeter design in High Energy Physics (HEP) by integrating Quantum Dot (QD) technology into traditional homogeneous calorimeters. The tunable emission spectra of QDs provide new possibilities for energy reconstruction and potentially improved particle identification in homogeneous devices. This paper presents the initial conceptual design of…
▽ More
Chromatic calorimetry introduces a novel approach to calorimeter design in High Energy Physics (HEP) by integrating Quantum Dot (QD) technology into traditional homogeneous calorimeters. The tunable emission spectra of QDs provide new possibilities for energy reconstruction and potentially improved particle identification in homogeneous devices. This paper presents the initial conceptual design of a chromatic calorimeter aimed at validating the feasibility of QD-based chromatic calorimetry. The study evaluates its expected performance through detailed simulations, comparing the results to the existing calorimetric technologies. By embedding QDs with distinct emission properties within scintillators, we aim to improve both timing resolution and longitudinal segmentation, thus opening new avenues for precision measurements in future HEP experiments. While further development and validation are required, QD-enhanced detectors may represent a viable option for future HEP experiments, providing an additional tool for addressing the evolving demands of particle detection.
△ Less
Submitted 22 January, 2025;
originally announced January 2025.
-
Progress in Chromatic Calorimetry Concept: Improved Techniques for Energy Resolution and Particle Discrimination
Authors:
Devanshi Arora,
Matteo Salomoni,
Yacine Haddad,
Vojtech Zabloudil,
Michael Doser,
Masaki Owari,
Etiennette Auffray
Abstract:
This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle interactions at different shower depths through wavelength-based discrimination. Our experimental validation of this novel method utilizes an arrangement of scintillat…
▽ More
This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle interactions at different shower depths through wavelength-based discrimination. Our experimental validation of this novel method utilizes an arrangement of scintillator materials to improve energy resolution and particle identification. The stacking arrangement of scintillators is organized by their emission wavelengths to track the development of electromagnetic and hadronic showers. By testing electrons and pions with energies up to 100 GeV, the setup demonstrated better discrimination and provided detailed measurements of shower profiles. The results indicate that our experimental validation significantly aims to enhance particle identification and energy resolution, highlighting its potential value in high-energy particle detection. Future work will explore the integration of Quantum Dots (QD) technology to advance these capabilities in chromatic calorimetry further.
△ Less
Submitted 14 January, 2025;
originally announced January 2025.
-
Exploring Scintillators and Cherenkov Radiators for MIP Timing Detectors
Authors:
R. Cala',
L. Martinazzoli,
N. Kratochwil,
I. Frank,
M. Salomoni,
F. Pagano,
G. Terragni,
C. Lowis,
J. Chen,
J. Pejchal,
P. Bohacek,
M. Nikl,
S. Tkachenko,
O. Sidlestkiy,
M. Paganoni,
M. Pizzichemi,
E. Auffray
Abstract:
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section 2 x 2 mm2 or 3 x 3 mm2 and length of 3 or 10 mm were coupled to Hamamatsu SiPM and read out by fast high-frequency electronics. Materials whose timing performan…
▽ More
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section 2 x 2 mm2 or 3 x 3 mm2 and length of 3 or 10 mm were coupled to Hamamatsu SiPM and read out by fast high-frequency electronics. Materials whose timing performance relies on Cherenkov emission, namely BGSO, PWO, and PbF2, achieved time resolutions in the range 24-36ps. Scintillators as L(Y)SO:Ce, GAGG, and BaF2 reached below 15 ps, the best topping at 12.1 +/- 0.4 ps. These fast materials are compared to LYSO and their additional benefit is discussed. Given the promising results of BaF2, the study is completed with measurements of the scintillation properties of a set doped with yttrium to quench the slow light emission.
△ Less
Submitted 20 January, 2025; v1 submitted 11 November, 2024;
originally announced November 2024.
-
Enhancing Energy Resolution and Particle Identification via Chromatic Calorimetry: A Concept Validation Study
Authors:
Devanshi Arora,
Matteo Salomoni,
Yacine Haddad,
Isabel Frank,
Loris Martinazzoli,
Marco Pizzichemi,
Michael Doser,
Masaki Owari,
Etiennette Auffray
Abstract:
In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into the properties of particles by analyzing their energy deposition patterns. Recent advances in material science, notably in nanomaterial scintillators with tunab…
▽ More
In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into the properties of particles by analyzing their energy deposition patterns. Recent advances in material science, notably in nanomaterial scintillators with tunable emission bandwidths, have led to the proposal of the chromatic calorimetry concept. This proposed concept aims to track electromagnetic or hadronic shower progression within a module, enhancing particle identification and energy resolution by layering scintillators with different emission wavelengths. The idea is to use the emission spectra of the inorganic scintillators to reconstruct the shower progression. Our study validates this proposed concept using inorganic scintillators strategically stacked by decreasing emission wavelength. Using electrons and pions with up to 100 GeV, we achieved analytical discrimination and longitudinal shower measurement. This proof of concept underscores chromatic calorimetry's potential for broader applications.
△ Less
Submitted 6 November, 2024;
originally announced November 2024.
-
Size-dependent multiexciton dynamics governs scintillation from perovskite quantum dots
Authors:
Andrea Fratelli,
Matteo L. Zaffalon,
Emanuele Mazzola,
Dmitry Dirin,
Ihor Cherniukh,
Clara Otero Martinez,
Matteo Salomoni,
Francesco Carulli,
Francesco Meinardi,
Luca Gironi,
Liberato Manna,
Maksym V. Kovalenko,
Sergio Brovelli
Abstract:
The recent emergence of quantum confined nanomaterials in the field of radiation detection, in particular lead halide perovskite nanocrystals, offers potentially revolutionary scalability and performance advantages over conventional materials. This development raises fundamental questions about the mechanism of scintillation itself at the nanoscale and the role of particle size, arguably the most…
▽ More
The recent emergence of quantum confined nanomaterials in the field of radiation detection, in particular lead halide perovskite nanocrystals, offers potentially revolutionary scalability and performance advantages over conventional materials. This development raises fundamental questions about the mechanism of scintillation itself at the nanoscale and the role of particle size, arguably the most defining parameter of quantum dots. Understanding this is crucial for the design and optimisation of future nanotechnology scintillators. In this work, we address these open questions by theoretically and experimentally studying the size-dependent scintillation of CsPbBr3 nanocrystals using a combination of Monte Carlo simulations, spectroscopic, and radiometric techniques. The results reveal and unravel a complex parametric space where the fine balance between the simultaneous effects of size-dependent energy deposition, (multi-)exciton population, and light emission under ionizing excitation, typical of confined particles, combine to maximize the scintillation efficiency and time performance of larger nanocrystals due to greater stopping power and reduced Auger decay. The remarkable agreement between theory and experiment produces a fully validated descriptive model that unprecedentedly predicts the scintillation yield and kinetics of nanocrystals without free parameters, providing the first fundamental guide for the rational design of nanoscale scintillators.
△ Less
Submitted 25 September, 2024;
originally announced September 2024.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Performance of a spaghetti calorimeter prototype with tungsten absorber and garnet crystal fibres
Authors:
Liupan An,
Etiennette Auffray,
Federico Betti,
Frederik Dall'Omo,
David Gascon,
Andrey Golutvin,
Yury Guz,
Sergey Kholodenko,
Loris Martinazzoli,
José Mazorra De Cos,
Eduardo Picatoste,
Marco Pizzichemi,
Philipp Roloff,
Matteo Salomoni,
David Sanchez,
Andreas Schopper,
Aleksandr Semennikov,
Pavel Shatalov,
Evgenii Shmanin,
Daria Strekalina,
Yanxi Zhang
Abstract:
A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG:Ce) and Y$_3$Al$_5$O$_{12}$ (YAG:Ce) embedded in a pure tungsten absorber. The energy resolution was studied as a function of the incidence angle of the beam and foun…
▽ More
A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG:Ce) and Y$_3$Al$_5$O$_{12}$ (YAG:Ce) embedded in a pure tungsten absorber. The energy resolution was studied as a function of the incidence angle of the beam and found to be of the order of $10\% / \sqrt{E} \oplus1\%$, in line with the LHCb Shashlik technology. The time resolution was measured with metal channel dynodes photomultipliers placed in contact with the fibres or coupled via a light guide, additionally testing an optical tape to glue the components. Time resolution of a few tens of picosecond was achieved for all the energies reaching down to (18.5 $\pm$ 0.2) ps at 5 GeV.
△ Less
Submitted 8 November, 2022; v1 submitted 5 May, 2022;
originally announced May 2022.