Detection of organic materials by spectrometric radiography method
Authors:
S. V. Naydenov,
V. D. Ryzhikov,
G. M. Onyshchenko,
P. Lecoq,
C. Smith
Abstract:
In this paper we report a spectrometric approach to dual-energy digital radiography that has been developed and applied to identify specific organic substances and discern small differences in their effective atomic number. An experimental setup has been designed, and a theoretical description proposed based on the experimental results obtained. The proposed method is based on application of spe…
▽ More
In this paper we report a spectrometric approach to dual-energy digital radiography that has been developed and applied to identify specific organic substances and discern small differences in their effective atomic number. An experimental setup has been designed, and a theoretical description proposed based on the experimental results obtained. The proposed method is based on application of special reference samples made of materials with different effective atomic number and thickness, parameters known to affect X-ray attenuation in the low-energy range. The results obtained can be used in the development of a new generation of multi-energy customs or medical X-ray scanners.
△ Less
Submitted 3 October, 2008;
originally announced October 2008.
-
Multi-Energy Radiography Against Terrorism. Theory and Experiments
Authors:
Sergei V. Naydenov,
Vladimir D. Ryzhikov,
Craig F. Smith,
Dennis Wood
Abstract:
Multi-energy radiography is a new direction in non-destructive testing. Its specific feature is separate detection of penetrating radiation in several energy channels. Multi-energy radiography allows quantitative determination of the atomic composition of objects. This is its principal advantage over conventional radiography. In particular, dual-energy radiography allows determination of the eff…
▽ More
Multi-energy radiography is a new direction in non-destructive testing. Its specific feature is separate detection of penetrating radiation in several energy channels. Multi-energy radiography allows quantitative determination of the atomic composition of objects. This is its principal advantage over conventional radiography. In particular, dual-energy radiography allows determination of the effective atomic number of a material with an accuracy of up to 80-90%. Development of three-energy radiography and radiography of higher multiplicity makes it possible to further improve the reconstruction of an objects chemical composition. This presents the possibility, for example, of detection of explosives and other illegal objects in luggage with a reliability approaching 100%. These developments can find application not only in anti-terrorist activities, but also in areas such as industrial testing and nuclear medicine.
△ Less
Submitted 21 May, 2006; v1 submitted 23 April, 2005;
originally announced April 2005.
-
Direct reconstruction of the effective atomic number of materials by the method of multi-energy radiography
Authors:
Sergey V. Naydenov,
Vladimir D. Ryzhikov,
Craig F. Smith
Abstract:
A direct method is proposed for reconstruction of the effective atomic number by means of multi-energy radiography of the material. The accuracy of the method is up to 95% . Advantages over conventional radiographic methods, which ensure accuracy of just about 50%, are discussed. A physical model has been constructed, and general expressions have been obtained for description of the effective at…
▽ More
A direct method is proposed for reconstruction of the effective atomic number by means of multi-energy radiography of the material. The accuracy of the method is up to 95% . Advantages over conventional radiographic methods, which ensure accuracy of just about 50%, are discussed. A physical model has been constructed, and general expressions have been obtained for description of the effective atomic number in a two-energy monitoring scheme. A universal dependence has been predicted for the effective atomic number as a function of relative (two-energy) radiographic reflex. The established theoretical law is confirmed by the experimental data presented. The proposed development can find multiple applications in non-destructive testing and related fields, including those in the civil sphere as well as anti-terrorist activities.
△ Less
Submitted 23 October, 2003;
originally announced October 2003.
-
Scintillator-photodiode type detectors for multi-energy scanning introscopy
Authors:
V. D. Ryzhikov,
S. V. Naydenov,
D. N. Kozin,
E. K. Lisetskaya,
A. D. Opolonin,
V. M. Svishch,
T. V. Kulik
Abstract:
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system up to 2-3 line pairs per mm. Theoretical analysis and experimental studies show that the two-energy detection method not only allows one to…
▽ More
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system up to 2-3 line pairs per mm. Theoretical analysis and experimental studies show that the two-energy detection method not only allows one to detect organics on the background of metal, but also substantially increases (by 3-5 times) the detection ability of the system as a whole, especially if parameters of the S-PD pair are optimized, in particular, when ZnSe(Te) is used in the low-energy circuit. A possibility to distinguish, in principle, between substances with insignificant differences in atomic number has been theoretically proven -- by transition to multi-energy radiography. 3D-imaging has been realized using S-PD detector arrays.
△ Less
Submitted 23 July, 2002;
originally announced July 2002.
-
X-ray multi-energy radiography with scintillator-photodiode detectors
Authors:
S. V. Naydenov,
V. D. Ryzhikov,
B. V. Grinyov,
E. K. Lisetskaya,
A. D. Opolonin,
D. N. Kozin
Abstract:
For reconstruction of the spatial structure of many-component objects, it is proposed to use multi-radiography with detection of X-ray by combined detector arrays using detectors of ``scintillator-photodiode'' type. A theoretical model has been developed of multi-energy radiography for thickness measurements of multi-layered systems and systems with defects. Experimental studies of the sensitivi…
▽ More
For reconstruction of the spatial structure of many-component objects, it is proposed to use multi-radiography with detection of X-ray by combined detector arrays using detectors of ``scintillator-photodiode'' type. A theoretical model has been developed of multi-energy radiography for thickness measurements of multi-layered systems and systems with defects. Experimental studies of the sensitivity, output signal of various inspection systems based on scintillators $ZnSe(Te)$ and $CsI(Tl)$, and object image reconstruction (with organics and non-ogranics materials singled out) have been carried out.
△ Less
Submitted 29 November, 2002; v1 submitted 5 June, 2002;
originally announced June 2002.
-
Multi-energy techniques for radiographic monitoring of chemical composition
Authors:
S. V. Naydenov,
V. D. Ryzhikov
Abstract:
A theoretical model of multi-energy radiography (MER) are proposed. It is shown that, as distinct from the conventional radiography, MER allows identification of organic substances and control of their chemical composition. Broad prospects are noted for MER application, specifically, for detection of prohibited substances (explosives, drugs, etc.) during customs and anti-terrorist safety inspect…
▽ More
A theoretical model of multi-energy radiography (MER) are proposed. It is shown that, as distinct from the conventional radiography, MER allows identification of organic substances and control of their chemical composition. Broad prospects are noted for MER application, specifically, for detection of prohibited substances (explosives, drugs, etc.) during customs and anti-terrorist safety inspection.
△ Less
Submitted 3 June, 2002;
originally announced June 2002.
-
Energy Resolution Improvement of Scintielectron detectors: Priorities and Prospects
Authors:
S. V. Naydenov,
V. D. Ryzhikov
Abstract:
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their theoretical and physical limits have been established. Empirical data on the properties of novel scintillators have been presented confirming the possibility of the R…
▽ More
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their theoretical and physical limits have been established. Empirical data on the properties of novel scintillators have been presented confirming the possibility of the R improvement. New optimization methods have been proposed to optimize the detector statistical fluctuations and the scintillator intrinsic resolution. A specific importance of the intrinsic resolution is shown as a limiting threshold factor at the ionizing radiation energy values from 662 keV to 10 MeV and over.
△ Less
Submitted 25 January, 2002;
originally announced January 2002.