The real-time data processing and acquisition system for Project 8 Phase II
Authors:
A. Ashtari Esfahani,
A. Banducci,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
B. Monreal,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
W. Pettus,
R. G. H. Robertson,
G. Rybka
, et al. (14 additional authors not shown)
Abstract:
In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or ${}^{83\mathrm{m}}$Kr are detected via their $\approx$26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting $\lesssim$10 ms and changing in frequency by $\lesssim$1 MHz/ms. To detect these signals, the Project 8…
▽ More
In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or ${}^{83\mathrm{m}}$Kr are detected via their $\approx$26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting $\lesssim$10 ms and changing in frequency by $\lesssim$1 MHz/ms. To detect these signals, the Project 8 collaboration developed a data acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.
△ Less
Submitted 27 June, 2025;
originally announced June 2025.
-
Project 8 Apparatus for Cyclotron Radiation Emission Spectroscopy with $^\mathrm{83m}$Kr and Tritium
Authors:
A. Ashtari Esfahani,
D. M. Asner,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
P. J. Doe,
J. L. Fernandes,
M. Fertl,
J. A. Formaggio,
D. Furse,
L. Gladstone,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
J. A. Kofron,
B. H. LaRoque,
A. Lindman,
E. Machado,
E. L. McBride,
P. Mohanmurthy,
R. Mohiuddin
, et al. (31 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project~8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project~8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of $\mathrm{^{83m}Kr}$ and the first CRES measurement of the beta-decay spectrum of molecular tritium.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
Maximizing Quantum Enhancement in Axion Dark Matter Experiments
Authors:
Chao-Lin Kuo,
Chelsea L. Bartram,
Aaron S. Chou,
Taj A. Dyson,
Noah A. Kurinsky,
Gray Rybka,
Sephora Ruppert,
Osmond Wen,
Matthew O. Withers,
Andrew K. Yi,
Cheng Zhang
Abstract:
We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1--30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies ($ν>$ 5 GHz), if they can be implemente…
▽ More
We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1--30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies ($ν>$ 5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the over-coupling regime, up to $β\sim 10$; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.
△ Less
Submitted 9 June, 2025; v1 submitted 20 November, 2024;
originally announced November 2024.
-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Real-time Signal Detection for Cyclotron Radiation Emission Spectroscopy Measurements using Antenna Arrays
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
B. T. Foust,
J. K. Gaison,
M. Grando,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
B. J. P. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
A. Marsteller,
C. Matthé,
R. Mohiuddin,
B. Monreal,
B. Mucogllava
, et al. (26 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms store…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. In this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
Authors:
S. Chakrabarty,
J. R. Gleason,
Y. Han,
A. T. Hipp,
M. Solano,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
M. Goryachev,
E. Hartman,
B. T. McAllister,
A. Quiskamp,
C. Thomson,
M. E. Tobar,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
T. Braine,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg
, et al. (22 additional authors not shown)
Abstract:
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and…
▽ More
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
△ Less
Submitted 28 March, 2023; v1 submitted 7 March, 2023;
originally announced March 2023.
-
Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields
Authors:
T. Braine,
G. Rybka,
A. A. Baker,
J. Brodsky,
G. Carosi,
N. Du,
N. Woollett,
S. Knirck,
M. Jones
Abstract:
This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi…
▽ More
This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment (ADMX), because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
ADMX-Orpheus First Search for 70 $μ$eV Dark Photon Dark Matter: Detailed Design, Operations, and Analysis
Authors:
R. Cervantes,
G. Carosi,
C. Hanretty,
S. Kimes,
B. H. LaRoque,
G. Leum,
P. Mohapatra,
N. S. Oblath,
R. Ottens,
Y. Park,
G. Rybka,
J. Sinnis,
J. Yang
Abstract:
Dark matter makes up 85% of the matter in the universe and 27% of its energy density, but we do not know what comprises dark matter. It is possible that dark matter may be composed of either axions or dark photons, both of which can be detected using an ultra-sensitive microwave cavity known as a haloscope. The haloscope employed by ADMX consists of a cylindrical cavity operating at the TM…
▽ More
Dark matter makes up 85% of the matter in the universe and 27% of its energy density, but we do not know what comprises dark matter. It is possible that dark matter may be composed of either axions or dark photons, both of which can be detected using an ultra-sensitive microwave cavity known as a haloscope. The haloscope employed by ADMX consists of a cylindrical cavity operating at the TM$_{010}$ mode and is sensitive to the QCD axion with masses of few $μ$eV. However, this haloscope design becomes challenging to implement for higher masses. This is because higher masses require smaller-diameter cavities, consequently reducing the detection volume which diminishes the detected signal power. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a higher-order mode, allowing the detection volume to remain large. This paper describes the design, operation, analysis, and results of the inaugural ADMX-Orpheus dark photon search between 65.5 $μ$eV (15.8 GHz) and 69.3 $μ$eV (16.8 GHz), as well as future directions for axion searches and for exploring more parameter space.
△ Less
Submitted 9 November, 2022; v1 submitted 20 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
The Project 8 Neutrino Mass Experiment
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
P. J. Doe,
S. Enomoto,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
M. Grando,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
R. Mueller,
J. A. Nikkel,
E. Novitski
, et al. (23 additional authors not shown)
Abstract:
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic t…
▽ More
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic tritium avoids an irreducible systematic uncertainty associated with the final states populated by the decay of molecular tritium. Project 8 will proceed in a phased approach toward a goal of 40 meV/c$^2$ neutrino-mass sensitivity.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Viterbi Decoding of CRES Signals in Project 8
Authors:
A. Ashtari Esfahani,
Z. Bogorad,
S. Böser,
N. Buzinsky,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
J. A. Nikkel,
E. Novitski
, et al. (23 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informa…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informational limits on the optimal detection of cyclotron radiation signals in this class of gas-filled CRES experiments, thereby providing concrete limits from which future reconstruction algorithms, as well as detector designs, can be constrained. The validity of the resultant decision rules is confirmed using both Monte Carlo and Project 8 data.
△ Less
Submitted 31 May, 2022; v1 submitted 7 December, 2021;
originally announced December 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Bayesian Analysis of a Future Beta Decay Experiment's Sensitivity to Neutrino Mass Scale and Ordering
Authors:
A. Ashtari Esfahani,
M. Betancourt,
Z. Bogorad,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
R. Mohiuddin,
B. Monreal,
J. A. Nikkel,
E. Novitski
, et al. (21 additional authors not shown)
Abstract:
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuo…
▽ More
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuous and discrete parameters. Using these procedures and a new Bayesian model of the $β$-decay spectrum, we assess a high-precision $β$-decay experiment's sensitivity to the neutrino mass scale and ordering, for one assumed design scenario. We find that such an experiment could measure the electron-weighted neutrino mass within $\sim40\,$meV after 1 year (90$\%$ credibility). Neutrino masses $>500\,$meV could be measured within $\approx5\,$meV. Using only $β$-decay and external reactor neutrino data, we find that next-generation $β$-decay experiments could potentially constrain the mass ordering using a two-neutrino spectral model analysis. By calibrating mass ordering results, we identify reporting criteria that can be tuned to suppress false ordering claims. In some cases, a two-neutrino analysis can reveal that the mass ordering is inverted, an unobtainable result for the traditional one-neutrino analysis approach.
△ Less
Submitted 1 June, 2021; v1 submitted 24 December, 2020;
originally announced December 2020.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Dielectric-Boosted Sensitivity to Cylindrical Azimuthally Varying Transverse-Magnetic Resonant Modes in an Axion Haloscope
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Gray Rybka,
Michael E. Tobar
Abstract:
Axions are a popular dark matter candidate which are often searched for in experiments known as ``haloscopes" which exploit a putative axion-photon coupling. These experiments typically rely on Transverse Magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant cavity design for application in haloscope searches, of par…
▽ More
Axions are a popular dark matter candidate which are often searched for in experiments known as ``haloscopes" which exploit a putative axion-photon coupling. These experiments typically rely on Transverse Magnetic (TM) modes in resonant cavities to capture and detect photons generated via axion conversion. We present a study of a resonant cavity design for application in haloscope searches, of particular use in the push to higher mass axion searches (above $\sim$60$\,μ$eV). In particular, we take advantage of azimuthally varying TM$_{m10}$ modes which, whilst typically insensitive to axions due to field non-uniformity, can be made axion-sensitive (and frequency tunable) through strategic placement of dielectric wedges, becoming a type of resonator known as a Dielectric Boosted Axion Sensitivity (DBAS) resonator. Results from finite-element modelling are presented, and compared with a simple proof-of-concept experiment. The results show a significant increase in axion sensitivity for these DBAS resonators over their empty cavity counterparts, and high potential for application in high mass axion searches when benchmarked against simpler, more traditional designs relying on fundamental TM modes.
△ Less
Submitted 8 November, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
ADMX SLIC: Results from a Superconducting LC Circuit Investigating Cold Axions
Authors:
N. Crisosto,
G. Rybka,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
J. Yang
Abstract:
Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub $2\times10^{-7}$ eV (50 MHz) range, a tunable lumped-element LC circuit has been proposed.…
▽ More
Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub $2\times10^{-7}$ eV (50 MHz) range, a tunable lumped-element LC circuit has been proposed. For the first time, through ADMX SLIC (Superconducting Lc circuit Investigating Cold axions), a resonant LC circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting LC circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency range $1.7498 -1.7519 \times10^{-7}$ eV (42.31 -- 42.36 MHz), $1.7734 - 1.7738 \times10^{-7}$ eV (42.88 -- 42.89 MHz), and $1.8007 - 1.8015 \times10^{-7}$ eV (43.54 -- 43.56 MHz) was covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T respectively. Exclusion results from the search data, for coupling below $10^{-12} \text{GeV}^{-1}$ are presented.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Locust: C++ software for simulation of RF detection
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
W. Pettus,
R. G. H. Robertson
, et al. (14 additional authors not shown)
Abstract:
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, d…
▽ More
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, demonstrating conditional feedback between Locust and Kassiopeia during software execution. An application of the simulation to the Project 8 experiment is described. Locust is publicly available at https://github.com/project8/locust_mc.
△ Less
Submitted 19 December, 2019; v1 submitted 25 July, 2019;
originally announced July 2019.
-
Electron Radiated Power in Cyclotron Radiation Emission Spectroscopy Experiments
Authors:
A. Ashtari Esfahani,
V. Bansal,
S. Boser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
P. J. Doe,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Leber,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath
, et al. (16 additional authors not shown)
Abstract:
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about…
▽ More
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters, and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
Authors:
N. Du,
N. Force,
R. Khatiwada,
E. Lentz,
R. Ottens,
L. J Rosenberg,
G. Rybka,
G. Carosi,
N. Woolett,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
C. Boutan,
N. S. Oblath,
R. Bradley,
E. J. Daw,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley,
N. Crisosto,
J. R. Gleason,
S. Jois,
P. Sikivie,
I. Stern
, et al. (3 additional authors not shown)
Abstract:
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from t…
▽ More
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
△ Less
Submitted 17 April, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.
-
Project 8 detector upgrades for a tritium beta decay spectrum using cyclotron radiation
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of…
▽ More
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of a new gas cell for use with tritium, and outline the primary goals of the experiment for the near future.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz facto…
▽ More
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz factor, this is also a measurement of the electron's energy. In order to demonstrate the viability of this technique, we have assembled and successfully operated a prototype system, which uses a rectangular waveguide to collect the cyclotron radiation from internal conversion electrons emitted from a gaseous $^{83m}$Kr source. Here we present the main design aspects of the first phase prototype, which was operated during parts of 2014 and 2015. We will also discuss the procedures used to analyze these data, along with the features which have been observed and the performance achieved to date.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Project 8 Phase III Design Concept
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Determining the neutrino mass with Cyclotron Radiation Emission Spectroscopy - Project 8
Authors:
Ali Ashtari Esfahani,
David M. Asner,
Sebastian Böser,
Raphael Cervantes,
Christine Claessens,
Luiz de Viveiros,
Peter J. Doe,
Shepard Doeleman,
Justin L. Fernandes,
Martin Fertl,
Erin C. Finn,
Joseph A. Formaggio,
Daniel Furse,
Mathieu Guigue,
Karsten M. Heeger,
A. Mark Jones,
Kareem Kazkaz,
Jared A. Kofron,
Callum Lamb,
Benjamin H. LaRoque,
Eric Machado,
Elizabeth L. McBride,
Michael L. Miller,
Benjamin Monreal,
Prajwal Mohanmurthy
, et al. (19 additional authors not shown)
Abstract:
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observati…
▽ More
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m(ν_e) \lesssim 0.2\,{\rm eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. In this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m(ν_e) \lesssim 40\,{\rm meV}$ using an atomic tritium source.
△ Less
Submitted 6 March, 2017;
originally announced March 2017.
-
Single electron detection and spectroscopy via relativistic cyclotron radiation
Authors:
D. M. Asner,
R. F. Bradley,
L. de Viveiros,
P. J. Doe,
J. L. Fernandes,
M. Fertl,
E. C. Finn,
J. A. Formaggio,
D. Furse,
A. M. Jones,
J. N. Kofron,
B. H. LaRoque,
M. Leber,
E. L. McBride,
M. L. Miller,
P. Mohanmurthy,
B. Monreal,
N. S. Oblath,
R. G. H. Robertson,
L. J Rosenberg,
G. Rybka,
D. Rysewyk,
M. G. Sternberg,
J. R. Tedeschi,
T. Thummler
, et al. (2 additional authors not shown)
Abstract:
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never…
▽ More
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spec- trometer. We observe the cyclotron radiation emitted by individual magnetically-trapped electrons that are produced with mildly-relativistic energies by a gaseous radioactive source. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta elec- tron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.
△ Less
Submitted 1 May, 2015; v1 submitted 22 August, 2014;
originally announced August 2014.
-
Improving Dark Matter Axion Searches with Active Resonators
Authors:
Gray Rybka
Abstract:
Axions are a well motivated candidate for dark matter. The most sensitive experiments searching for dark matter axions rely on the coupling of axions to the electromagnetic resonances of a microwave cavity immersed in a strong magnetic field. The sensitivity of the experiment is proportional to the Q of the resonance that is coupled to axions. To date, the resonators used in axion searches have al…
▽ More
Axions are a well motivated candidate for dark matter. The most sensitive experiments searching for dark matter axions rely on the coupling of axions to the electromagnetic resonances of a microwave cavity immersed in a strong magnetic field. The sensitivity of the experiment is proportional to the Q of the resonance that is coupled to axions. To date, the resonators used in axion searches have all been passive, with Qs limited by power loss in the cavity walls. I propose the use of active feedback resonators to increase the Q of microwave cavity axion dark matter experiments by several orders of magnitude. This should allow experiments to significantly increase the rate at which they can test potential axion masses and couplings.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.
-
A Search for Dark Matter Axions with the Orpheus Experiment
Authors:
Gray Rybka,
Andrew Wagner,
Aryeh Brill,
Kunal Patel,
Robert Percival,
Katleiah Ramos
Abstract:
Axions are well motivated particles that could make up most or all of the dark matter if they have masses below 100 $μ$eV. Microwave cavity techniques comprised of closed resonant structures immersed in solenoid magnets are sensitive to dark matter axions with masses of a few $μ$eV, but face difficulties scaling to higher masses. We present the a novel detector architecture consisting of an open,…
▽ More
Axions are well motivated particles that could make up most or all of the dark matter if they have masses below 100 $μ$eV. Microwave cavity techniques comprised of closed resonant structures immersed in solenoid magnets are sensitive to dark matter axions with masses of a few $μ$eV, but face difficulties scaling to higher masses. We present the a novel detector architecture consisting of an open, Fabry-Pérot resonator and a series of current-carrying wire planes, and demonstrate this technique with a search for dark matter axion-like particles called Orpheus. This search excludes dark matter axion-like particles with masses between 68.2 and 76.5 $μ$eV and axion-photon couplings greater than $4\times10^{-7} \mathrm{GeV}^{-1}$. We project that the fundamental sensitivity of this technique could be extended to be sensitive to couplings below $1\times10^{-15} \mathrm{GeV}^{-1}$, consistent with the DFSZ model of QCD axions.
△ Less
Submitted 20 February, 2015; v1 submitted 12 March, 2014;
originally announced March 2014.
-
Project 8: Determining neutrino mass from tritium beta decay using a frequency-based method
Authors:
P. J. Doe,
J. Kofron,
E. L. McBride,
R. G. H. Robertson,
L. J Rosenberg,
G. Rybka,
S. Doelman,
A. Rogers,
J. A. Formaggio,
D. Furse,
N. S. Oblath,
B. H. LaRoque,
M. Leber,
B. Monreal,
M. Bahr,
D. M. Asner,
A. M. Jones,
J. Fernandes,
B. A. VanDevender,
R. Patterson,
R. Bradley,
T. Thuemmler
Abstract:
A general description is given of Project 8, a new approach to measuring the neutrino mass scale via the beta decay of tritium. In Project 8, the energy of electrons emitted in beta decay is determined from the frequency of cyclotron radiation emitted as the electrons spiral in a uniform magnetic field.
A general description is given of Project 8, a new approach to measuring the neutrino mass scale via the beta decay of tritium. In Project 8, the energy of electrons emitted in beta decay is determined from the frequency of cyclotron radiation emitted as the electrons spiral in a uniform magnetic field.
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
Hidden Sector Photon Coupling of Resonant Cavities
Authors:
Stephen R. Parker,
Gray Rybka,
Michael E. Tobar
Abstract:
Many beyond the standard model theories introduce light paraphotons, a hypothetical spin-1 field that kinetically mixes with photons. Microwave cavity experiments have traditionally searched for paraphotons via transmission of power from an actively driven cavity to a passive receiver cavity, with the two cavities separated by a barrier that is impenetrable to photons. We extend this measurement t…
▽ More
Many beyond the standard model theories introduce light paraphotons, a hypothetical spin-1 field that kinetically mixes with photons. Microwave cavity experiments have traditionally searched for paraphotons via transmission of power from an actively driven cavity to a passive receiver cavity, with the two cavities separated by a barrier that is impenetrable to photons. We extend this measurement technique to account for two-way coupling between the cavities and show that the presence of a paraphoton field can alter the resonant frequencies of the coupled cavity pair. We propose an experiment that exploits this effect and uses measurements of a cavities resonant frequency to constrain the paraphoton-photon mixing parameter, chi. We show that such an experiment can improve sensitivity to chi over existing experiments for paraphoton masses less than the resonant frequency of the cavity, and eliminate some of the most common systematics for resonant cavity experiments.
△ Less
Submitted 25 April, 2013;
originally announced April 2013.
-
Move of a large but delicate apparatus on a trailer with air-ride suspension
Authors:
B. Thomas,
D. Will,
J. Heilman,
K. Tracy,
M. Hotz,
D. Lyapustin,
L. J Rosenberg,
G. Rybka,
A. Wagner,
J. Hoskins,
C. Martin,
N. S. Sullivan,
D. B. Tanner,
S. J. Asztalos,
G. Carosi,
C. Hagmann,
D. Kinion,
K. van Bibber,
R. Bradley,
J. Clarke
Abstract:
When valuable delicate goods are shipped by truck, attention must be paid to vibrations that may cause damage. We present a case study of moving an extremely delicate 6230-kg superconducting magnet, immersed in liquid nitrogen, from Livermore, CA to Seattle, WA showing the steps of fatigue analysis of the load, a test move, and acceleration monitoring of the final move to ensure a successful damag…
▽ More
When valuable delicate goods are shipped by truck, attention must be paid to vibrations that may cause damage. We present a case study of moving an extremely delicate 6230-kg superconducting magnet, immersed in liquid nitrogen, from Livermore, CA to Seattle, WA showing the steps of fatigue analysis of the load, a test move, and acceleration monitoring of the final move to ensure a successful damage-free transport.
△ Less
Submitted 26 May, 2011;
originally announced May 2011.
-
Design and performance of the ADMX SQUID-based microwave receiver
Authors:
S. J. Asztalos,
G. Carosi,
C. Hagmann,
D. Kinion,
K. van Bibber,
M. Hotz,
L. J Rosenberg,
G. Rybka,
A. Wagner,
J. Hoskins,
C. Martin,
N. S. Sullivan,
D. B. Tanner,
R. Bradley,
John Clarke
Abstract:
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device…
▽ More
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as well as the analysis of narrow band microwave signals. We demonstrate the sustained use of a SQUID amplifier operating between 812 and 860 MHz with a noise temperature of 1 K. The receiver has a noise equivalent power of 1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of 1.8x10^3 s.
△ Less
Submitted 20 May, 2011;
originally announced May 2011.
-
A Multiwire Proportional Chamber for Precision Studies of Neutron Beta Decay Angular Correlations
Authors:
T. M. Ito,
R. Carr,
B. W. Filippone,
J. W. Martin,
B. Plaster,
G. Rybka,
J. Yuan
Abstract:
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the po…
▽ More
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the position resolution were studied.
△ Less
Submitted 10 February, 2007;
originally announced February 2007.