-
Real-time fetAl brain and placental T2* mapping at 0.55T low-field MRI (RAT)
Authors:
Jordina Aviles Verdera,
Sara Neves Silva,
Raphael Tomi-Tricot,
Megan Hall,
Lisa Story,
Shaihan J Malik,
Joseph V Hajnal,
Mary A Rutherford,
Jana Hutter
Abstract:
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 da…
▽ More
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 datasets for the fetal brain and a second one trained on 210 datasets for the placenta for automatic segmentation. T2* normal curves were obtained from 106 cases and prospective evaluation was performed on 10 cases between 35 and 39 weeks GA.
Results: Quantitative brain and placental T2* maps and centiles were available in all prospective cases within 30 seconds. The robustness of the method was shown with intra-scan repeats (mean difference 1.04+/-12.39 ms for fetal brain and -3.15+/-8.88 ms for placenta) and direct validation with vendor-processed offline results (mean difference 1.62+/-4.33 ms for fetal brain and 0.16+/-6.19 ms for placenta).
Discussion and Conclusion: Real-time available organ-specific quantitative information enables more personalized MR examinations, selection of the most pertinent sequences and thus the promise of reduced recalls and specific insights into tissue properties. The here enabled placental T2*, demonstrated in multiple recent studies to be a biomarker sensitive to a range of pregnancy complications, and fetal brain T2* will be explored in further studies in pregnancies with pre-eclampsia, growth restriction as a way of enabling future MR-guided fetal interventions.
△ Less
Submitted 25 September, 2024;
originally announced September 2024.
-
AutOmatic floW planning for fetaL MRI (OWL)
Authors:
Sara Neves Silva,
Tomas Woodgate,
Sarah McElroy,
Michela Cleri,
Kamilah St Clair,
Jordina Aviles Verdera,
Kelly Payette,
Alena Uus,
Lisa Story,
David Lloyd,
Mary A Rutherford,
Joseph V Hajnal,
Kuberan Pushparajah,
Jana Hutter
Abstract:
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landm…
▽ More
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landmarks for planning. The OWL pipeline was evaluated retrospectively in 10 datasets and prospectively in 7 fetal subjects (gestational ages between 36+3 and 39+3 weeks). The prospective cases were additionally manually planned to enable direct comparison both qualitatively, by scoring the planning quality, and quantitatively, by comparing the indexed flow measurements. OWL enabled real-time fully automatic planning of the 2D phase-contrast scans in all but one of the prospective participants. The fetal body localization achieved an overall Dice score of 0.94+-0.05 and the cardiac landmark detection accuracy was 5.77+-2.91 mm for the descending aorta, 4.32+-2.44 mm for the spine, and 4.94+-3.82 mm for the umbilical vein. For the prospective cases, overall planning quality was 2.73/4 for the automated scans, compared to 3.0/4 for manual planning, and the flow quantitative evaluation showed a mean difference of -1.8% (range -14.2% to 14.9%) by comparing the indexed flow measurements obtained from gated automatic and manual acquisitions. Real-time automated planning of 2D phase-contrast MRI was effectively accomplished for 2 major vessels of the fetal vasculature. While demonstrated here on 0.55T, the achieved method has wider implications, and training across multiple field strengths enables generalization. OWL thereby presents an important step towards extending access to this modality beyond specialised centres.
△ Less
Submitted 12 August, 2024;
originally announced August 2024.
-
Fully automated planning for anatomical fetal brain MRI on 0.55T
Authors:
Sara Neves Silva,
Sarah McElroy,
Jordina Aviles Verdera,
Kathleen Colford,
Kamilah St Clair,
Raphael Tomi-Tricot,
Alena Uus,
Valery Ozenne,
Megan Hall,
Lisa Story,
Kuberan Pushparajah,
Mary A Rutherford,
Joseph V Hajnal,
Jana Hutter
Abstract:
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from…
▽ More
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. Comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality and the resulting image quality was conducted. Results: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.21+-2.56 mm for the fetal eyes and 6.47+-3.23 for the cerebellum, planning quality was 2.44/3 (compared to 2.56/3 for manual planning) and diagnostic image quality was 2.14 compared to 2.07 for manual planning. Conclusions: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way towards simplifying the acquisition of fetal MRI thereby widening the availability of this modality in non-specialist centres.
△ Less
Submitted 18 January, 2024;
originally announced January 2024.
-
An automated pipeline for quantitative T2* fetal body MRI and segmentation at low field
Authors:
Kelly Payette,
Alena Uus,
Jordina Aviles Verdera,
Carla Avena Zampieri,
Megan Hall,
Lisa Story,
Maria Deprez,
Mary A. Rutherford,
Joseph V. Hajnal,
Sebastien Ourselin,
Raphael Tomi-Tricot,
Jana Hutter
Abstract:
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing to…
▽ More
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R^2>0.5). This pipeline was used successfully for a wide range of GAs (17-40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
△ Less
Submitted 9 August, 2023;
originally announced August 2023.
-
Deformable Slice-to-Volume Registration for Motion Correction in Fetal Body MRI
Authors:
Alena Uus,
Tong Zhang,
Laurence H. Jackson,
Thomas A. Roberts,
Mary A. Rutherford,
Joseph V. Hajnal,
Maria Deprez
Abstract:
In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain that undergoes only rigid transformation. However, for reconstruction of fetal bo…
▽ More
In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain that undergoes only rigid transformation. However, for reconstruction of fetal body and placenta, rigid registration cannot resolve the issue of misregistrations due to deformable motion, resulting in degradation of features in the reconstructed volume. We propose a Deformable SVR (DSVR), a novel approach for non-rigid motion correction of fetal MRI based on a hierarchical deformable SVR scheme to allow high resolution reconstruction of the fetal body and placenta. Additionally, a robust scheme for structure-based rejection of outliers minimises the impact of registration errors. The improved performance of DSVR in comparison to SVR and patch-to-volume registration (PVR) methods is quantitatively demonstrated in simulated experiments and 20 fetal MRI datasets from 28-31 weeks gestational age (GA) range with varying degree of motion corruption. In addition, we present qualitative evaluation of 100 fetal body cases from 20-34 weeks GA range.
△ Less
Submitted 28 February, 2020; v1 submitted 20 June, 2019;
originally announced June 2019.
-
Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI
Authors:
Joshua FP van Amerom,
David FA Lloyd,
Maria Deprez,
Anthony N Price,
Shaihan J Malik,
Kuberan Pushparajah,
Milou PM van Poppel,
Mary A Rutherford,
Reza Razavi,
Joseph V Hajnal
Abstract:
Purpose: To develop a MRI acquisition and reconstruction framework for volumetric cine visualisation of the fetal heart and great vessels in the presence of maternal and fetal motion.
Methods: Four-dimensional depiction was achieved using a highly-accelerated multi-planar real-time balanced steady state free precession acquisition combined with retrospective image-domain techniques for motion co…
▽ More
Purpose: To develop a MRI acquisition and reconstruction framework for volumetric cine visualisation of the fetal heart and great vessels in the presence of maternal and fetal motion.
Methods: Four-dimensional depiction was achieved using a highly-accelerated multi-planar real-time balanced steady state free precession acquisition combined with retrospective image-domain techniques for motion correction, cardiac synchronisation and outlier rejection. The framework was evaluated and optimised using a numerical phantom, and evaluated in a study of 20 mid- to late-gestational age human fetal subjects. Reconstructed cine volumes were evaluated by experienced cardiologists and compared with matched ultrasound. A preliminary assessment of flow-sensitive reconstruction using the velocity information encoded in the phase of dynamic images is included.
Results: Reconstructed cine volumes could be visualised in any 2D plane without the need for highly-specific scan plane prescription prior to acquisition or for maternal breath hold to minimise motion. Reconstruction was fully automated aside from user-specified masks of the fetal heart and chest. The framework proved robust when applied to fetal data and simulations confirmed that spatial and temporal features could be reliably recovered. Expert evaluation suggested the reconstructed volumes can be used for comprehensive assessment of the fetal heart, either as an adjunct to ultrasound or in combination with other MRI techniques.
Conclusion: The proposed methods show promise as a framework for motion-compensated 4D assessment of the fetal heart and great vessels.
△ Less
Submitted 5 December, 2018;
originally announced December 2018.