-
Brillouin lasers in Bragg grating microresonators
Authors:
Ryan L. Russell,
Moritz Merklein,
Choon Kong Lai,
Cong Tinh Bui,
Alvaro Casas-Bedoya,
Duk-Yong Choi,
Stephen J. Madden,
Benjamin J. Eggleton
Abstract:
Chip-scale coherent light sources are required in applications spanning metrology and sensing to telecommunications. Brillouin lasers (BLs) offer a route to ultra-coherent optical sources in compact microresonators with free spectral range (FSR) matched to the Brillouin frequency shift (BFS). However, BFS - FSR matching typically facilitates cascaded Brillouin scattering, constraining achievable B…
▽ More
Chip-scale coherent light sources are required in applications spanning metrology and sensing to telecommunications. Brillouin lasers (BLs) offer a route to ultra-coherent optical sources in compact microresonators with free spectral range (FSR) matched to the Brillouin frequency shift (BFS). However, BFS - FSR matching typically facilitates cascaded Brillouin scattering, constraining achievable BL output power and coherence. Here, we demonstrate inhibition of cascading in a planar-integrated chalcogenide microresonator by exploiting the photonic bandgap (PBG) associated with a post-fabrication inscribed, reconfigurable intracavity Bragg grating. The PBG inhibits energy transfer within the target Brillouin scattering pathway, such as from pump to first-order Stokes wave. As a quantitative measure of Brillouin scattering inhibition, we report at least six-fold increase in threshold for onset of BL oscillation, which is ultimately limited by thermorefraction. For on-chip pump power of 399 mW, sufficient for a tenth-order Brillouin cascade, complete inhibition was achieved. Our work positions Bragg grating microresonators as an enabling platform for high performance on-chip BL sources, with reconfigurable modes of operation.
△ Less
Submitted 4 June, 2025;
originally announced June 2025.
-
Measurement and tricubic interpolation of the magnetic field for the OLYMPUS experiment
Authors:
J. C. Bernauer,
J. Diefenbach,
G. Elbakian,
G. Gavrilov,
N. Goerrissen,
D. K. Hasel,
B. S. Henderson,
Y. Holler,
G. Karyan,
J. Ludwig,
H. Marukyan,
Y. Naryshkin,
C. O'Connor,
R. L. Russell,
A. Schmidt,
U. Schneekloth,
K. Suvorov,
D. Veretennikov
Abstract:
The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translat…
▽ More
The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translation tables. We used these field data to fit a numerical magnetic field model, which could be employed to calculate the magnetic field at any point in the spectrometer volume. Calculations with this model were computationally intensive; for analysis applications where speed was crucial, we pre-computed the magnetic field and its derivatives on an evenly spaced grid so that the field could be interpolated between grid points. We developed a spline-based interpolation scheme suitable for SIMD implementations, with a memory layout chosen to minimize space and optimize the cache behavior to quickly calculate field values. This scheme requires only one-eighth of the memory needed to store necessary coefficients compared with a previous scheme [1]. This method was accurate for the vast majority of the spectrometer volume, though special fits and representations were needed to improve the accuracy close to the magnet coils and along the toroid axis.
△ Less
Submitted 21 March, 2016;
originally announced March 2016.
-
The OLYMPUS Experiment
Authors:
R. Milner,
D. K. Hasell,
M. Kohl,
U. Schneekloth,
N. Akopov,
R. Alarcon,
V. A. Andreev,
O. Ates,
A. Avetisyan,
D. Bayadilov,
R. Beck,
S. Belostotski,
J. C. Bernauer,
J. Bessuille,
F. Brinker,
B. Buck,
J. R. Calarco,
V. Carassiti,
E. Cisbani,
G. Ciullo,
M. Contalbrigo,
N. D'Ascenzo,
R. De Leo,
J. Diefenbach,
T. W. Donnelly
, et al. (48 additional authors not shown)
Abstract:
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and…
▽ More
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.
△ Less
Submitted 5 December, 2013;
originally announced December 2013.