A CsI(Tl) detector array for the measurement of light charged particles in heavy-ion reactions
Authors:
P. C. Rout,
V. M. Datar,
D. R. Chakrabarty,
Suresh Kumar,
E. T. Mirgule,
A. Mitra,
V. Nanal,
R. Kujur
Abstract:
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $α$-particles from 5 to 40 MeV is measured using radioactive sources and the $^{12}$C($^{12}$C, $α$) reaction populating discrete states in $^{20}$Ne. The energy non-linearity and the c…
▽ More
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $α$-particles from 5 to 40 MeV is measured using radioactive sources and the $^{12}$C($^{12}$C, $α$) reaction populating discrete states in $^{20}$Ne. The energy non-linearity and the count rate effect on the pulse shape discrimination property have also been measured and observed the deterioration of pulse shape discrimination with higher count rate.
△ Less
Submitted 17 May, 2017;
originally announced May 2017.
-
Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons
Authors:
P. C. Rout,
A. Gandhi,
T. Basak,
R. G. Thomas,
C. Ghosh,
A. Mitra,
G. Mishra,
S. P. Behera,
R. Kujur,
E. T. Mirgule,
B. K. Nayak,
A. Saxena,
Suresh Kumar,
V. M. Datar
Abstract:
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination…
▽ More
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.
△ Less
Submitted 16 May, 2017;
originally announced May 2017.
-
Characterization of PARIS LaBr$_3$(Ce)-NaI(Tl) phoswich detectors upto $E_γ$ $\sim$ 22 MeV
Authors:
C. Ghosh,
V. Nanal,
R. G. Pillay,
Anoop K. V,
N. Dokania,
Sanjoy Pal,
M. S. Pose,
G. Mishra,
P. C. Rout,
Suresh Kumar,
Deepak Pandit,
Debasish Mondal,
Surajit Pal,
S. R. Banerjee,
Paweł J. Napiorkowski,
Oliver Dorvaux,
S. Kihel,
C. Mathieu,
A. Maj
Abstract:
In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out. The detector response is investigated over a wide range of $E_γ$ = 0.6 to 22.6 MeV using radioactive sources and employing $^{11}B(p,γ)$ reaction at $E_p$ = 163 k…
▽ More
In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out. The detector response is investigated over a wide range of $E_γ$ = 0.6 to 22.6 MeV using radioactive sources and employing $^{11}B(p,γ)$ reaction at $E_p$ = 163 keV and $E_p$ = 7.2 MeV. The linearity of energy response of the LaBr$_3$(Ce) detector is tested upto 22.6 MeV using three different voltage dividers. The data acquisition system using CAEN digitizers is set up and optimized to get the best energy and time resolution. The energy resolution of $\sim$ 2.1% at $E_γ$ = 22.6~MeV is measured for the configuration giving best linearity upto high energy. Time resolution of the phoswich detector is measured with a $^{60}$Co source after implementing CFD algorithm for the digitized pulses and is found to be excellent (FWHM $\sim$ 315~ps). In order to study the effect of count rate on detectors, the centroid position and width of the $E_γ$ = 835~keV peak were measured upto 220 kHz count rate. The measured efficiency data with radioactive sources are in good agreement with GEANT4 based simulations. The total energy spectrum after the add-back of energy signals in phoswich components is also presented.
△ Less
Submitted 20 May, 2016; v1 submitted 3 May, 2016;
originally announced May 2016.