Accelerating Low-field MRI: Compressed Sensing and AI for fast noise-robust imaging
Authors:
Efrat Shimron,
Shanshan Shan,
James Grover,
Neha Koonjoo,
Sheng Shen,
Thomas Boele,
Annabel J. Sorby-Adams,
John E. Kirsch,
Matthew S. Rosen,
David E. J. Waddington
Abstract:
Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, critical barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan duration. As these systems can operate in unusual environments, the level and spectral characteristics of the environmental electromagnetic inference…
▽ More
Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, critical barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan duration. As these systems can operate in unusual environments, the level and spectral characteristics of the environmental electromagnetic inference (EMI) noise can change substantially across sites and scans, further reducing image quality. Methods for accelerating acquisition and boosting image quality are of critical importance to enable clinically actionable high-quality imaging in these systems. Despite the role that compressed sensing (CS) and artificial intelligence (AI)-based methods have had in improving image quality for high-field MRI, their adoption for low-field imaging is in its infancy, and it is unclear how robust these methods are in low SNR regimes. Here, we investigate and compare leading CS and AI-based methods for image reconstruction from subsampled data and perform a thorough analysis of their performance across a range of SNR values. We compare classical L1-wavelet CS with leading data-driven and model-driven AI methods. Experiments are performed using publicly available datasets and our own low-field and high-field experimental data. Specifically, we apply an unrolled AI network to low-field MRI, and find it outperforms competing reconstruction methods. We prospectively deploy our undersampling methods to accelerate imaging on a 6.5 mT MRI scanner. This work highlights the potential and pitfalls of advanced reconstruction techniques in low-field MRI, paving the way for broader clinical applications.
△ Less
Submitted 10 November, 2024;
originally announced November 2024.
-
Machine Learning for Improved Current Density Reconstruction from 2D Vector Magnetic Images
Authors:
Niko R. Reed,
Danyal Bhutto,
Matthew J. Turner,
Declan M. Daly,
Sean M. Oliver,
Jiashen Tang,
Kevin S. Olsson,
Nicholas Langellier,
Mark J. H. Ku,
Matthew S. Rosen,
Ronald L. Walsworth
Abstract:
The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high spatial frequency noise or large standoff distance, restricting the types of systems that…
▽ More
The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high spatial frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional (2D) images of vector magnetic fields acquired by a quantum diamond microscope (QDM) utilizing a surface layer of Nitrogen Vacancy (NV) centers in diamond. Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower SNR data, reducing the data collection time by a factor of about 400 and permitting reconstructions of weaker and three-dimensional current sources.
△ Less
Submitted 11 January, 2025; v1 submitted 18 July, 2024;
originally announced July 2024.
-
A statistical learning framework for mapping indirect measurements of ergodic systems to emergent properties
Authors:
Nicholas Hindley,
Stephen J. DeVience,
Ella Zhang,
Leo L. Cheng,
Matthew S. Rosen
Abstract:
The discovery of novel experimental techniques often lags behind contemporary theoretical understanding. In particular, it can be difficult to establish appropriate measurement protocols without analytic descriptions of the underlying system-of-interest. Here we propose a statistical learning framework that avoids the need for such descriptions for ergodic systems. We validate this framework by us…
▽ More
The discovery of novel experimental techniques often lags behind contemporary theoretical understanding. In particular, it can be difficult to establish appropriate measurement protocols without analytic descriptions of the underlying system-of-interest. Here we propose a statistical learning framework that avoids the need for such descriptions for ergodic systems. We validate this framework by using Monte Carlo simulation and deep neural networks to learn a mapping between low-field nuclear magnetic resonance spectra and proton exchange rates in ethanol-water mixtures. We found that trained networks exhibited normalized-root-mean-square errors of less than 1% for exchange rates under 150 s-1 but performed poorly for rates above this range. This differential performance occurred because low-field measurements are indistinguishable from one another at fast exchange. Nonetheless, where a discoverable relationship between indirect measurements and emergent dynamics exists, we demonstrate the possibility of approximating it without the need for precise analytic descriptions, allowing experimental science to flourish in the midst of ongoing theoretical work
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
Homonuclear J-Coupling Spectroscopy using J-Synchronized Echo Detection
Authors:
Stephen J. DeVience,
Matthew S. Rosen
Abstract:
In the strong coupling regime with J-coupling much larger than chemical shift differences, J-coupling spectroscopy enables spectral identification of molecules even when conventional NMR fails. While this classically required the presence of a heteronucleus, we recently showed that J-coupling spectra can be acquired in many homonuclear systems using spin-lock induced crossing (SLIC). Here, we pres…
▽ More
In the strong coupling regime with J-coupling much larger than chemical shift differences, J-coupling spectroscopy enables spectral identification of molecules even when conventional NMR fails. While this classically required the presence of a heteronucleus, we recently showed that J-coupling spectra can be acquired in many homonuclear systems using spin-lock induced crossing (SLIC). Here, we present an alternative method using a spin echo train in lieu of a spin-locking SLIC pulse, which has a number of advantages. In particular, spin echo acquisition within the pulse train enables simultaneous collection of time and frequency data. The resulting 2D spectrum can be used to study dynamic spin evolution, and the time domain data can be averaged to create a 1D J-coupling spectrum with increased signal-to-noise ratio.
△ Less
Submitted 15 April, 2022;
originally announced April 2022.
-
RASER MRI: Magnetic Resonance Images formed Spontaneously exploiting Cooperative Nonlinear Interaction
Authors:
Sören Lehmkuhl,
Simon Fleischer,
Lars Lohmann,
Matthew S. Rosen,
Eduard Y. Chekmenev,
Alina Adams,
Thomas Theis,
Stephan Appelt
Abstract:
The spatial resolution of magnetic resonance imaging (MRI) is fundamentally limited by the width of Lorentzian point spread functions (PSF) associated with the exponential decay rate of transverse magnetization (1/T2*). Here we show a different contrast mechanism in MRI by establishing RASER (Radio-frequency Amplification by Stimulated Emission of Radiation) in imaged media. RASER imaging bursts e…
▽ More
The spatial resolution of magnetic resonance imaging (MRI) is fundamentally limited by the width of Lorentzian point spread functions (PSF) associated with the exponential decay rate of transverse magnetization (1/T2*). Here we show a different contrast mechanism in MRI by establishing RASER (Radio-frequency Amplification by Stimulated Emission of Radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying (Radio Frequency) RF pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. A small difference in initial population inversion density creates a stronger image contrast than conventional MRI. This contrast is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Both the contrast and the artifacts are demonstrated experimentally and predicted by simulations based on a proposed theory. This theory of RASER MRI is strongly connected to many other distinct fields related to synergetics and non-linear dynamics.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
On Real-time Image Reconstruction with Neural Networks for MRI-guided Radiotherapy
Authors:
David E. J. Waddington,
Nicholas Hindley,
Neha Koonjoo,
Christopher Chiu,
Tess Reynolds,
Paul Z. Y. Liu,
Bo Zhu,
Danyal Bhutto,
Chiara Paganelli,
Paul J. Keall,
Matthew S. Rosen
Abstract:
MRI-guidance techniques that dynamically adapt radiation beams to follow tumor motion in real-time will lead to more accurate cancer treatments and reduced collateral healthy tissue damage. The gold-standard for reconstruction of undersampled MR data is compressed sensing (CS) which is computationally slow and limits the rate that images can be available for real-time adaptation. Here, we demonstr…
▽ More
MRI-guidance techniques that dynamically adapt radiation beams to follow tumor motion in real-time will lead to more accurate cancer treatments and reduced collateral healthy tissue damage. The gold-standard for reconstruction of undersampled MR data is compressed sensing (CS) which is computationally slow and limits the rate that images can be available for real-time adaptation. Here, we demonstrate the use of automated transform by manifold approximation (AUTOMAP), a generalized framework that maps raw MR signal to the target image domain, to rapidly reconstruct images from undersampled radial k-space data. The AUTOMAP neural network was trained to reconstruct images from a golden-angle radial acquisition, a benchmark for motion-sensitive imaging, on lung cancer patient data and generic images from ImageNet. Model training was subsequently augmented with motion-encoded k-space data derived from videos in the YouTube-8M dataset to encourage motion robust reconstruction. We find that AUTOMAP-reconstructed radial k-space has equivalent accuracy to CS but with much shorter processing times after initial fine-tuning on retrospectively acquired lung cancer patient data. Validation of motion-trained models with a virtual dynamic lung tumor phantom showed that the generalized motion properties learned from YouTube lead to improved target tracking accuracy. Our work shows that AUTOMAP can achieve real-time, accurate reconstruction of radial data. These findings imply that neural-network-based reconstruction is potentially superior to existing approaches for real-time image guidance applications.
△ Less
Submitted 18 May, 2022; v1 submitted 9 February, 2022;
originally announced February 2022.
-
NMR of $^{31}$P Nuclear Spin Singlet States in Organic Diphosphates
Authors:
Stephen J. DeVience,
Ronald L. Walsworth,
Matthew S. Rosen
Abstract:
$^{31}$P NMR and MRI are commonly used to study organophosphates that are central to cellular energy metabolism. In some molecules of interest, such as adenosine diphosphate (ADP) and nicotinamide adenine dinucleotide (NAD), pairs of coupled $^{31}…
▽ More
$^{31}$P NMR and MRI are commonly used to study organophosphates that are central to cellular energy metabolism. In some molecules of interest, such as adenosine diphosphate (ADP) and nicotinamide adenine dinucleotide (NAD), pairs of coupled $^{31}$P nuclei in the diphosphate moiety should enable the creation of nuclear spin singlet states, which may be long-lived and can be selectively detected via quantum filters. Here, we show that $^{31}$P singlet states can be created on ADP and NAD, but their lifetimes are shorter than T$_{1}$ and are strongly sensitive to pH. Nevertheless, the singlet states were used with a quantum filter to successfully isolate the $^{31}$P NMR spectra of those molecules from the adenosine triphosphate (ATP) background signal.
△ Less
Submitted 16 September, 2021;
originally announced September 2021.
-
An End-to-End AI-Based Framework for Automated Discovery of CEST/MT MR Fingerprinting Acquisition Protocols and Quantitative Deep Reconstruction (AutoCEST)
Authors:
Or Perlman,
Bo Zhu,
Moritz Zaiss,
Matthew S. Rosen,
Christian T. Farrar
Abstract:
Purpose: To develop an automated machine-learning-based method for the discovery of rapid and quantitative chemical exchange saturation transfer (CEST) MR fingerprinting acquisition and reconstruction protocols.
Methods: An MR physics governed AI system was trained to generate optimized acquisition schedules and the corresponding quantitative reconstruction neural-network. The system (termed Aut…
▽ More
Purpose: To develop an automated machine-learning-based method for the discovery of rapid and quantitative chemical exchange saturation transfer (CEST) MR fingerprinting acquisition and reconstruction protocols.
Methods: An MR physics governed AI system was trained to generate optimized acquisition schedules and the corresponding quantitative reconstruction neural-network. The system (termed AutoCEST) is composed of a CEST saturation block, a spin dynamics module, and a deep reconstruction network, all differentiable and jointly connected. The method was validated using a variety of chemical exchange phantoms and an in-vivo mouse brain at 9.4T.
Results: The acquisition times for AutoCEST optimized schedules ranged from 35-71s, with a quantitative image reconstruction time of only 29 ms. The resulting exchangeable proton concentration maps for the phantoms were in good agreement with the known solute concentrations for AutoCEST sequences (mean absolute error = 2.42 mM; Pearson's r=0.992 , p$<$0.0001), but not for an unoptimized sequence (mean absolute error = 65.19 mM; Pearson's r=-0.161, p=0.522). Similarly, improved exchange rate agreement was observed between AutoCEST and quantification of exchange using saturation power (QUESP) methods (mean absolute error: 35.8 Hz, Pearson's r=0.971, p$<$0.0001) compared to an unoptimized schedule and QUESP (mean absolute error = 58.2 Hz; Pearson's r=0.959, p$<$0.0001). The AutoCEST in-vivo mouse brain semi-solid proton volume-fractions were lower in the cortex (12.21$\pm$1.37%) compared to the white-matter (19.73 $\pm$ 3.30%), as expected, and the amide proton volume-fraction and exchange rates agreed with previous reports.
Conclusion: AutoCEST can automatically generate optimized CEST/MT acquisition protocols that can be rapidly reconstructed into quantitative exchange parameter maps.
△ Less
Submitted 9 July, 2021;
originally announced July 2021.
-
Two-Orders-of-Magnitude Improvement in the Total Spin Angular Momentum of 131Xe Nuclei Using Spin Exchange Optical Pumping
Authors:
Michael J. Molway,
Liana Bales-Shaffer,
Kaili Ranta,
Dustin Basler,
Megan Murphy,
Bryce E. Kidd,
Abdulbasit Tobi Gafar,
Justin Porter,
Kierstyn Albin,
Boyd M. Goodson,
Eduard Y. Chekmenev,
Matthew S. Rosen,
W. Michael Snow,
James Ball,
Eleanor Sparling,
Mia Prince,
Daniel Cocking,
Michael J. Barlow
Abstract:
We report on hyperpolarization of quadrupolar (I=3/2) 131Xe via spin-exchange optical pumping. Observations of the 131Xe polarization dynamics show that the effective alkali-metal/131Xe spin-exchange cross-sections are large enough to compete with 131Xe spin relaxation. 131Xe polarization up to 7.6 p/m 1.5 percent was achieved in ca. 8.5EE20 spins--a ca. 100-fold improvement in the total spin angu…
▽ More
We report on hyperpolarization of quadrupolar (I=3/2) 131Xe via spin-exchange optical pumping. Observations of the 131Xe polarization dynamics show that the effective alkali-metal/131Xe spin-exchange cross-sections are large enough to compete with 131Xe spin relaxation. 131Xe polarization up to 7.6 p/m 1.5 percent was achieved in ca. 8.5EE20 spins--a ca. 100-fold improvement in the total spin angular momentum--enabling applications including measurement of spin-dependent neutron-131Xe s-wave scattering and sensitive searches for time-reversal violation in neutron-131Xe interactions beyond the Standard Model.
△ Less
Submitted 7 May, 2021;
originally announced May 2021.
-
Homonuclear J-Coupling Spectroscopy at Low Magnetic Fields using Spin-Lock Induced Crossing
Authors:
Stephen J. DeVience,
Mason Greer,
Soumyajit Mandal,
Matthew S. Rosen
Abstract:
Nuclear magnetic resonance (NMR) spectroscopy usually requires high magnetic fields to create spectral resolution among different proton species. At low fields, chemical shift dispersion is insufficient to separate the species, and the spectrum exhibits just a single line. In this work, we demonstrate that spectra can nevertheless be acquired at low field using a novel pulse sequence called spin-l…
▽ More
Nuclear magnetic resonance (NMR) spectroscopy usually requires high magnetic fields to create spectral resolution among different proton species. At low fields, chemical shift dispersion is insufficient to separate the species, and the spectrum exhibits just a single line. In this work, we demonstrate that spectra can nevertheless be acquired at low field using a novel pulse sequence called spin-lock induced crossing (SLIC). This probes energy level crossings induced by a weak spin-locking pulse and produces a unique J-coupling spectrum for most organic molecules. Unlike other forms of low-field J-coupling spectroscopy, our technique does not require the presence of heteronuclei and can be used for most compounds in their native state. We performed SLIC spectroscopy on a number of small molecules at 276 kHz and 20.8 MHZ, and we show that SLIC spectra can be simulated in good agreement with measurements.
△ Less
Submitted 1 March, 2021;
originally announced March 2021.
-
Micron-scale SABRE-enhanced NV-NMR Spectroscopy
Authors:
Nithya Arunkumar,
Dominik B. Bucher,
Matthew J. Turner,
Patrick TomHon,
David Glenn,
Soren Lehmkuhl,
Mikhail D. Lukin,
Hongkun Park,
Matthew S. Rosen,
Thomas Theis,
Ronald L. Walsworth
Abstract:
Optically-probed nitrogen-vacancy (NV) quantum defects in diamond can detect nuclear magnetic resonance (NMR) signals with high-spectral resolution from micron-scale sample volumes of about 10 picoliters. However, a key challenge for NV-NMR is detecting samples at millimolar concentrations. Here, we demonstrate an improvement in NV-NMR proton concentration sensitivity of about $10^5$ over thermal…
▽ More
Optically-probed nitrogen-vacancy (NV) quantum defects in diamond can detect nuclear magnetic resonance (NMR) signals with high-spectral resolution from micron-scale sample volumes of about 10 picoliters. However, a key challenge for NV-NMR is detecting samples at millimolar concentrations. Here, we demonstrate an improvement in NV-NMR proton concentration sensitivity of about $10^5$ over thermal polarization by hyperpolarizing sample proton spins through signal amplification by reversible exchange (SABRE), enabling micron-scale NMR of small molecule sample concentrations as low as 1 millimolar in picoliter volumes. The SABRE-enhanced NV-NMR technique may enable detection and chemical analysis of low concentration molecules and their dynamics in complex micron-scale systems such as single-cells.
△ Less
Submitted 17 June, 2020; v1 submitted 6 June, 2020;
originally announced June 2020.
-
A Portable Brain MRI Scanner for Underserved Settings and Point-Of-Care Imaging
Authors:
Clarissa Z. Cooley,
Patrick C. McDaniel,
Jason P. Stockmann,
Sai Abitha Srinivas,
Stephen Cauley,
Monika Sliwiak,
Charlotte R. Sappo,
Christopher F. Vaughn,
Bastien Guerin,
Matthew S. Rosen,
Michael H. Lev,
Lawrence L. Wald
Abstract:
Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design pr…
▽ More
Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design presented here aims to extend the reach of MRI by substantially reducing these limitations. Our goal is to shift the cost-benefit calculation for MRI toward more frequent and varied use, including improved accessibility worldwide and point of care operation. Here, we describe a portable brain MRI scanner using a compact, lightweight permanent magnet, with a built-in readout field gradient. Our low-field (80 mT) Halbach cylinder design of rare-earth permanent magnets results in a 122 kg magnet with minimal stray-field, requiring neither cryogenics nor external power. The built-in magnetic field gradient reduces reliance on high-power gradient drivers, which not only lowers overall system power and cooling requirements, but also reduces acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique, that uses prior characterization of the field patterns. Our system was validated using T1, T2 and proton density weighted in vivo brain images with a spatial resolution of 2.2 x 1.3 x 6.8 mm$^3$.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
CEST MR-Fingerprinting: practical considerations and insights for acquisition schedule design and improved reconstruction
Authors:
Or Perlman,
Kai Herz,
Moritz Zaiss,
Ouri Cohen,
Matthew S. Rosen,
Christian T. Farrar
Abstract:
Purpose: To understand the influence of various acquisition parameters on the ability of CEST MR-Fingerprinting (MRF) to discriminate different chemical exchange parameters and to provide tools for optimal acquisition schedule design and parameter map reconstruction. Methods: Numerical simulations were conducted using a parallel-computing implementation of the Bloch-McConnell equations, examining…
▽ More
Purpose: To understand the influence of various acquisition parameters on the ability of CEST MR-Fingerprinting (MRF) to discriminate different chemical exchange parameters and to provide tools for optimal acquisition schedule design and parameter map reconstruction. Methods: Numerical simulations were conducted using a parallel-computing implementation of the Bloch-McConnell equations, examining the effect of TR, TE, flip-angle, water T$_{1}$ and T$_{2}$, saturation-pulse duration, power, and frequency on the discrimination ability of CEST-MRF. A modified Euclidean-distance matching metric was evaluated and compared to traditional dot-product matching. L-Arginine phantoms of various concentrations and pH were scanned at 4.7T and the results compared to numerical findings. Results: Simulations for dot-product matching demonstrated that the optimal flip-angle and saturation times are 30$^{\circ}$ and 1100 ms, respectively. The optimal maximal saturation power was 3.4 $μ$T for concentrated solutes with a slow exchange-rate, and 5.2 $μ$T for dilute solutes with medium-to-fast exchange-rates. Using the Euclidean-distance matching metric, much lower maximum saturation powers were required (1.6 and 2.4 $μ$T, respectively), with a slightly longer saturation time (1500 ms) and 90$^{\circ}$ flip-angle. For both matching metrics, the discrimination ability increased with the repetition time. The experimental results were in agreement with simulations, demonstrating that more than a 50% reduction in scan-time can be achieved by Euclidean-distance-based matching. Conclusion: Optimization of the CEST-MRF acquisition schedule is critical for obtaining the best exchange parameter accuracy. The use of Euclidean-distance-based matching of signal trajectories simultaneously improved the discrimination ability and reduced the scan time and maximal saturation power required.
△ Less
Submitted 22 April, 2019;
originally announced April 2019.
-
Rapid and Quantitative Chemical Exchange Saturation Transfer (CEST) Imaging with Magnetic Resonance Fingerprinting (MRF)
Authors:
Ouri Cohen,
Shuning Huang,
Michael T. McMahon,
Matthew S. Rosen,
Christian T. Farrar
Abstract:
Purpose: To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging.
Methods: We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the N$α$-amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms w…
▽ More
Purpose: To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging.
Methods: We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the N$α$-amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 $μ$T; in vivo: 0-4 $μ$T) with a total acquisition time of <=2 minutes. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T1 and T2* relaxation times.
Results: The chemical exchange rates of the N$α$-amine protons of L-Arg were significantly (p<0.0001) correlated with the rates measured with the Quantitation of Exchange using Saturation Power method. Similarly, the L-Arg concentrations determined using MRF were significantly (p<0.0001) correlated with the known concentrations. The pH dependence of the exchange rate was well fit (R2=0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (36.3+-12.9 Hz) was in good agreement with that measured previously with the Water Exchange spectroscopy method (28.6+-7.4 Hz). The semi-solid proton volume fraction was elevated in white (11.2+-1.7%) compared to gray (7.6+-1.8%) matter brain regions in agreement with previous magnetization transfer studies.
Conclusion: CEST-MRF provides a method for fast, quantitative CEST imaging.
△ Less
Submitted 18 October, 2017; v1 submitted 16 October, 2017;
originally announced October 2017.
-
Probing Scalar Coupling Differences via Long-Lived Singlet States
Authors:
Stephen J. DeVience,
Ronald L. Walsworth,
Matthew S. Rosen
Abstract:
We probe small scalar coupling differences via the coherent interactions between two nuclear spin singlet states in organic molecules. We show that the spin-lock induced crossing (SLIC) technique enables the coherent transfer of singlet order between one spin pair and another. The transfer is mediated by the difference in cis and trans vicinal J couplings among the spins. By measuring the transfer…
▽ More
We probe small scalar coupling differences via the coherent interactions between two nuclear spin singlet states in organic molecules. We show that the spin-lock induced crossing (SLIC) technique enables the coherent transfer of singlet order between one spin pair and another. The transfer is mediated by the difference in cis and trans vicinal J couplings among the spins. By measuring the transfer rate, we calculate a J coupling difference of $8 \pm 2$ mHz in phenylalanine-glycine-glycine and $2.57 \pm 0.04$ Hz in glutamate. We also characterize a coherence between two singlet states in glutamate, which may enable the creation of a long-lived quantum memory.
△ Less
Submitted 7 September, 2015;
originally announced September 2015.
-
Preparation of Nuclear Spin Singlet States using Spin-Lock Induced Crossing
Authors:
Stephen J. DeVience,
Ronald L. Walsworth,
Matthew S. Rosen
Abstract:
We introduce a broadly applicable technique to create nuclear spin singlet states in organic molecules and other many-atom systems. We employ a novel pulse sequence to produce a spin-lock induced crossing (SLIC) of the spin singlet and triplet energy levels, which enables triplet/singlet polarization transfer and singlet state preparation. We demonstrate the utility of the SLIC method by producing…
▽ More
We introduce a broadly applicable technique to create nuclear spin singlet states in organic molecules and other many-atom systems. We employ a novel pulse sequence to produce a spin-lock induced crossing (SLIC) of the spin singlet and triplet energy levels, which enables triplet/singlet polarization transfer and singlet state preparation. We demonstrate the utility of the SLIC method by producing a long-lived nuclear spin singlet state on two strongly-coupled proton pairs in the tripeptide molecule phenylalanine-glycine-glycine dissolved in D2O, and by using SLIC to measure the J-couplings, chemical shift differences, and singlet lifetimes of the proton pairs. We show that SLIC is more efficient at creating nearly-equivalent nuclear spin singlet states than previous pulse sequence techniques, especially when triplet/singlet polarization transfer occurs on the same timescale as spin-lattice relaxation.
△ Less
Submitted 2 July, 2013;
originally announced July 2013.
-
Dependence of nuclear spin singlet lifetimes on RF spin-locking power
Authors:
Stephen J. DeVience,
Ronald L. Walsworth,
Matthew S. Rosen
Abstract:
We measure the lifetime of long-lived nuclear spin singlet states as a function of the strength of the RF spin-locking field and present a simple theoretical model that agrees well with our measurements, including the low-RF-power regime. We also measure the lifetime of a long-lived coherence between singlet and triplet states that does not require a spin-locking field for preservation. Our result…
▽ More
We measure the lifetime of long-lived nuclear spin singlet states as a function of the strength of the RF spin-locking field and present a simple theoretical model that agrees well with our measurements, including the low-RF-power regime. We also measure the lifetime of a long-lived coherence between singlet and triplet states that does not require a spin-locking field for preservation. Our results indicate that for many molecules, singlet states can be created using weak RF spin-locking fields: more than two orders of magnitude lower RF power than in previous studies. Our findings suggest that in many biomolecules, singlets and related states with enhanced lifetimes might be achievable in vivo with safe levels of RF power.
△ Less
Submitted 6 January, 2012;
originally announced January 2012.
-
Posture-Dependent Human 3He Lung Imaging in an Open Access MRI System: Initial Results
Authors:
L. L. Tsai,
R. W. Mair,
C. -H. Li,
M. S. Rosen,
S. Patz,
R. L. Walsworth
Abstract:
The human lung and its functions are extremely sensitive to orientation and posture, and debate continues as to the role of gravity and the surrounding anatomy in determining lung function and heterogeneity of perfusion and ventilation. However, study of these effects is difficult. The conventional high-field magnets used for most hyperpolarized 3He MRI of the human lung, and most other common r…
▽ More
The human lung and its functions are extremely sensitive to orientation and posture, and debate continues as to the role of gravity and the surrounding anatomy in determining lung function and heterogeneity of perfusion and ventilation. However, study of these effects is difficult. The conventional high-field magnets used for most hyperpolarized 3He MRI of the human lung, and most other common radiological imaging modalities including PET and CT, restrict subjects to lying horizontally, minimizing most gravitational effects. In this paper, we briefly review the motivation for posture-dependent studies of human lung function, and present initial imaging results of human lungs in the supine and vertical body orientations using inhaled hyperpolarized 3He gas and an open-access MRI instrument. The open geometry of this MRI system features a "walk-in" capability that permits subjects to be imaged in vertical and horizontal positions, and potentially allows for complete rotation of the orientation of the imaging subject in a two-dimensional plane. Initial results include two-dimensional lung images acquired with ~ 4 mm in-plane resolution and three-dimensional images with ~ 1.5 cm slice thickness. Effects of posture variation are observed.
△ Less
Submitted 23 July, 2007;
originally announced July 2007.
-
3He Lung Imaging in an Open Access, Very-Low-Field Human MRI System
Authors:
R. W. Mair,
M. I. Hrovat,
S. Patz,
M. S. Rosen,
I. C. Ruset,
G. P. Topulos,
L. L. Tsai,
J. P. Butler,
F. W. Hersman,
R. L. Walsworth
Abstract:
The human lung and its functions are extremely sensitive to gravity, however the conventional high-field magnets used for most laser-polarized 3He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized 3He gas is demonstrated in an open-access very-low-magnetic-field (< 5 mT) MRI instrument. This prototype device employs a simple, low-…
▽ More
The human lung and its functions are extremely sensitive to gravity, however the conventional high-field magnets used for most laser-polarized 3He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized 3He gas is demonstrated in an open-access very-low-magnetic-field (< 5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4 mm in-plane resolution from a subject in two orientations: lying supine, and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation.
△ Less
Submitted 16 December, 2004; v1 submitted 18 March, 2004;
originally announced March 2004.
-
Bound on Lorentz- and CPT-Violating Boost Effects for the Neutron
Authors:
F. Canè,
D. Bear,
D. F. Phillips,
M. S. Rosen,
C. L. Smallwood,
R. E. Stoner,
R. L. Walsworth,
V. Alan Kostelecký
Abstract:
A search for an annual variation of a daily sidereal modulation of the frequency difference between co-located ${}^{129}$Xe and ${}^{3}$He Zeeman masers sets a stringent limit on boost-dependent Lorentz and CPT violation involving the neutron, consistent with no effect at the level of 150 nHz. In the framework of the general Standard-Model Extension, the present result provides the first clean t…
▽ More
A search for an annual variation of a daily sidereal modulation of the frequency difference between co-located ${}^{129}$Xe and ${}^{3}$He Zeeman masers sets a stringent limit on boost-dependent Lorentz and CPT violation involving the neutron, consistent with no effect at the level of 150 nHz. In the framework of the general Standard-Model Extension, the present result provides the first clean test for the fermion sector of the symmetry of spacetime under boost transformations at a level of $10^{-27}$ GeV.
△ Less
Submitted 28 October, 2004; v1 submitted 15 September, 2003;
originally announced September 2003.