-
Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors
Authors:
C. L. Chang,
Y. -Y. Chang,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
P. K. Patel,
B. Penning,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
I. Rydstrom,
R. K. Romani,
B. Sadoulet,
B. Serfass,
P. Sorensen,
B. Suerfu,
V. Velan,
G. Wang
, et al. (3 additional authors not shown)
Abstract:
Solid state phonon detectors used in the search for dark matter or coherent neutrino nucleus interactions (CE$ν$NS) require excellent energy resolution (eV-scale or below) and low backgrounds to meet their science objectives. Unfortunately, an unknown source of phonon bursts (the low energy excess, or ``LEE'') both dominates all other above threshold background sources and produces shot noise from…
▽ More
Solid state phonon detectors used in the search for dark matter or coherent neutrino nucleus interactions (CE$ν$NS) require excellent energy resolution (eV-scale or below) and low backgrounds to meet their science objectives. Unfortunately, an unknown source of phonon bursts (the low energy excess, or ``LEE'') both dominates all other above threshold background sources and produces shot noise from sub-threshold bursts which greatly exceeds all fundamental noise sources. In this paper, we measure these phonon bursts for 12 days after cool down in two nearly identical multi-phonon sensor channel 1cm$^2$ silicon detectors which differ only in the thickness of their substrate (1 mm vs 4 mm thick). We find that both the correlated shot noise and near threshold shared LEE relax with time since cooldown. Additionally, we show that both shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise we estimate that $\varepsilon = \frac{<E^2>}{<E>}$ for sub-threshold noise events is $0.68 \pm 0.38$ meV. In our final dataset, we report a world-leading energy resolution of 258.5$\pm$0.4 meV in the 1mm thick detector. Simple calculations suggest that these Si substrate phonon bursts are likely the dominant source of quasi-particle poisoning in superconducting qubits and sensors that are operated in well shielded and vibration free environments.
△ Less
Submitted 22 May, 2025; v1 submitted 21 May, 2025;
originally announced May 2025.
-
Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors
Authors:
Daniel Baxter,
Rouven Essig,
Yonit Hochberg,
Margarita Kaznacheeva,
Belina von Krosigk,
Florian Reindl,
Roger K. Romani,
Felix Wagner
Abstract:
Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others…
▽ More
Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids. Their understanding is essential for interpreting particle interactions at and below the eV-scale.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration
Authors:
C. L. Chang,
Y. -Y. Chang,
L. Chaplinsky,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
V. Novati,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani,
B. Sadoulet,
B. Serfass
, et al. (23 additional authors not shown)
Abstract:
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g…
▽ More
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.
△ Less
Submitted 28 March, 2025; v1 submitted 5 March, 2025;
originally announced March 2025.
-
Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter
Authors:
Robin Anthony-Petersen,
Clarence L. Chang,
Yen-Yung Chang,
Luke Chaplinsky,
Caleb W. Fink,
Maurice Garcia-Sciveres,
Wei Guo,
Scott A. Hertel,
Xinran Li,
Junsong Lin,
Marharyta Lisovenko,
Rupak Mahapatra,
William Matava,
Daniel N. McKinsey,
David Z. Osterman,
Pratyush K. Patel,
Bjoern Penning,
Mark Platt,
Matt Pyle,
Yinghe Qi,
Maggie Reed,
Ivar Rydstrom,
Roger K. Romani,
Bernard Sadoulet,
Bruno Serfass
, et al. (7 additional authors not shown)
Abstract:
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal p…
▽ More
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.
△ Less
Submitted 4 April, 2025; v1 submitted 21 October, 2024;
originally announced October 2024.
-
Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors
Authors:
L. Chaplinsky,
S. Fiorucci,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
J. K. Wuko,
X. Li,
J. Lin,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
D. Z. Osterman,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani,
P. Sorensen,
V. Velan,
G. Wang,
Y. Wang
, et al. (2 additional authors not shown)
Abstract:
We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoener…
▽ More
We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoenergetic spectrum using a feature in the neutron cross section of scandium. In this approach, unmoderated high-energy neutrons form a challenging background, along with gammas from neutron capture in the moderator materials. We describe the optimization of the moderator+filter and shielding geometry, and find a geometry that in simulation achieves both the target neutron flux at 2 keV and subdominant rates of background interactions. Lastly, we describe a future path to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons.
△ Less
Submitted 14 October, 2024;
originally announced October 2024.
-
A Transition Edge Sensor Operated in Coincidence with a High Sensitivity Athermal Phonon Sensor for Photon Coupled Rare Event Searches
Authors:
Roger K. Romani,
Yen-Yung Chang,
Rupak Mahapatra,
Mark Platt,
Maggie Reed,
Ivar Rydstrom,
Bernard Sadoulet,
Bruno Serfass,
Matt Pyle
Abstract:
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a Transition Edge Sensor (TES) with a photon energy resolution $σ_γ= 368.4 \pm 0.4$ meV, is colocated on the same substrate as a l…
▽ More
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a Transition Edge Sensor (TES) with a photon energy resolution $σ_γ= 368.4 \pm 0.4$ meV, is colocated on the same substrate as a large high sensitivity athermal phonon sensor (APS) with a phonon energy resolution $σ_\mathrm{phonon} = 701 \pm 2$ meV. We show that single 3.061 eV photons absorbed in the photon-sensing TES deposit $\sim$35\% of their energy in the electronic system of the TES, while $\sim$26\% of the photon energy leaks out of the photon-sensing TES during the downconversion process and becomes absorbed by the APS. Backgrounds, which we associate with the broadly observed ``low energy excess'' (LEE), are observed to be largely coupled to either the TES (``singles'' LEE), or phonon system, (``shared'' LEE). At high energies, these backgrounds can be efficiently discriminated from TES photon absorption events, while at low energies, their misidentification as photon events is well modeled. With significant sensitivity improvements to both the TES and APS, this coincidence technique could be used to suppress backgrounds in bosonic dark matter searches down to energies near the superconducting bandgap of the sensor.
△ Less
Submitted 28 May, 2025; v1 submitted 20 August, 2024;
originally announced August 2024.
-
Aluminum Relaxation as the Source of Excess Low Energy Events in Low Threshold Calorimeters
Authors:
Roger K. Romani
Abstract:
A previously unexplained background called the Low Energy Excess (LEE) has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminium films as mediated by the motion of dislocations may account for these observations.
A previously unexplained background called the Low Energy Excess (LEE) has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminium films as mediated by the motion of dislocations may account for these observations.
△ Less
Submitted 26 September, 2024; v1 submitted 21 May, 2024;
originally announced June 2024.
-
First Demonstration of the HeRALD Superfluid Helium Detector Concept
Authors:
R. Anthony-Petersen,
A. Biekert,
C. L. Chang,
Y. Chang,
L. Chaplinsky,
A. Dushkin,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
D. Z. Osterman,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani
, et al. (11 additional authors not shown)
Abstract:
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to th…
▽ More
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of 0.15 $\pm$ 0.01, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5 sigma, which would be sensitive to dark matter masses down to 220 MeV/c$^2$.
△ Less
Submitted 4 November, 2024; v1 submitted 21 July, 2023;
originally announced July 2023.
-
A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter
Authors:
A. Biekert,
C. Chang,
L. Chaplinsky,
C. W. Fink,
W. D. Frey,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
D. N. McKinsey,
S. Mehrotra,
N. Mirabolfathi,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Reed,
R. K. Romani,
B. Sadoulet,
R. J. Smith,
P. Sorensen,
B. Suerfu,
A. Suzuki
, et al. (5 additional authors not shown)
Abstract:
A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutr…
▽ More
A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.
△ Less
Submitted 7 February, 2023;
originally announced February 2023.
-
A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning
Authors:
Robin Anthony-Petersen,
Andreas Biekert,
Raymond Bunker,
Clarence L. Chang,
Yen-Yung Chang,
Luke Chaplinsky,
Eleanor Fascione,
Caleb W. Fink,
Maurice Garcia-Sciveres,
Richard Germond,
Wei Guo,
Scott A. Hertel,
Ziqing Hong,
Noah Kurinsky,
Xinran Li,
Junsong Lin,
Marharyta Lisovenko,
Rupak Mahapatra,
Adam Mayer,
Daniel N. McKinsey,
Siddhant Mehrotra,
Nader Mirabolfathi,
Brian Neblosky,
William A. Page,
Pratyush K. Patel
, et al. (21 additional authors not shown)
Abstract:
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show…
▽ More
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.
△ Less
Submitted 14 August, 2024; v1 submitted 4 August, 2022;
originally announced August 2022.
-
A backing detector for order-keV neutrons
Authors:
A. Biekert,
L. Chaplinsky,
C. W. Fink,
M. Garcia-Sciveres,
W. C. Gillis,
W. Guo,
S. A. Hertel,
G. Heuermann,
X. Li,
J. Lin,
R. Mahapatra,
D. N. McKinsey,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
R. K. Romani,
A. Serafin,
R. J. Smith,
B. Suerfu,
V. Velan,
G. Wang,
Y. Wang,
S. L. Watkins
, et al. (1 additional authors not shown)
Abstract:
We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scatte…
▽ More
We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$ν$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of $\sim$25\% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of $\sim$17$~μ$s. The prototype was characterized using a \ce{^{252}Cf} neutron source and agreement with the simulation was observed within a few percent level.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
Scintillation yield from electronic and nuclear recoils in superfluid $^4$He
Authors:
SPICE/HeRALD Collaboration,
:,
A. Biekert,
C. Chang,
C. W. Fink,
M. Garcia-Sciveres,
E. C. Glazer,
W. Guo,
S. A. Hertel,
S. Kravitz,
J. Lin,
M. Lisovenko,
R. Mahapatra,
D. N. McKinsey,
J. S. Nguyen,
V. Novosad,
W. Page,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Pyle,
R. K. Romani,
A. S. Seilnacht,
A. Serafin,
R. J. Smith
, et al. (9 additional authors not shown)
Abstract:
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~c…
▽ More
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.
△ Less
Submitted 14 May, 2022; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Nuclear Recoil Scintillation Linearity of a High Pressure $^4$He Gas Detector
Authors:
A. Biekert,
S. A. Hertel,
E. Huebler,
J. Lin,
H. D. Pinckney,
R. K. Romani,
A. Serafin,
V. Velan,
D. N. McKinsey
Abstract:
We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Mo…
▽ More
We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. We demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.
△ Less
Submitted 10 October, 2019; v1 submitted 9 July, 2019;
originally announced July 2019.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Thermal detection of single e-h pairs in a biased silicon crystal detector
Authors:
R. K. Romani,
P. L. Brink,
B. Cabrera,
M. Cherry,
T. Howarth,
N. Kurinsky,
R. A. Moffatt,
R. Partridge,
F. Ponce,
M. Pyle,
A. Tomada,
S. Yellin,
J. J. Yen,
B. A. Young
Abstract:
We demonstrate that individual electron-hole pairs are resolved in a 1 cm$^2$ by 4 mm thick silicon crystal (0.93 g) operated at $\sim$35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays held near ground potential. The other side contains a bias grid with 20\% coverage. Bias potentials up to $\pm$ 160 V were…
▽ More
We demonstrate that individual electron-hole pairs are resolved in a 1 cm$^2$ by 4 mm thick silicon crystal (0.93 g) operated at $\sim$35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays held near ground potential. The other side contains a bias grid with 20\% coverage. Bias potentials up to $\pm$ 160 V were used in the work reported here. A fiber optic provides 650~nm (1.9 eV) photons that each produce an electron-hole ($e^{-} h^{+}$) pair in the crystal near the grid. The energy of the drifting charges is measured with a phonon sensor noise $σ$ $\sim$0.09 $e^{-} h^{+}$ pair. The observed charge quantization is nearly identical for $h^+$'s or $e^-$'s transported across the crystal.
△ Less
Submitted 15 December, 2017; v1 submitted 25 October, 2017;
originally announced October 2017.